42Q-MES0085-C Conduit Command Appendix

From 42Q
Revision as of 13:45, 14 October 2024 by Afra Banu (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

42Q Home > Conduit > Conduit Command Appendix
 

 

Conduit
Conduit Command Appendix
Version MES 15.82
Revision L1
 
 
 

 

Contents

Command Appendix Registry

The commands defined within the Conduit Command Registry represent the core functionality of the Conduit system. Unlike with legacy systems, Conduit commands are full words, generally Pascal case (though technically command names are case insensitive.)

In addition to the more extensive names, Conduit Commands tend to be more focused on a single concept. Most Conduit commands expect all of their data to be provided upfront, leaving the work of gathering that data to the various client implementations in conjunction with the CCRS.

The commands referencing Assembly or Defined components and attributes respectively are designed for use with the Scanning Template mechanism in Conduit. The basic concept is that the actual command to use (tracked, unique, non tracked, etc.) will be provided by Conduit. Individual clients only need to prompt for the appropriate piece of data to satisfy the scan template then construct a Client Command from the Scan Template + user input.

The full list of commands and a short explanation of each are given below:

 

 

A

AddAttribute

Description: Adds an attribute to the scanned unit. This command will produce an error if the attribute already exists, no replacement will occur.

Parameters: ParametersFields that can be passed to Add Attribute calls. 

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Attribute Name?

attr_name* Attribute Value? attr_data*

Mask?

mask

 

 

AddAttributeTo

Description: Adds an attribute to the specified unit serial number. This command will produce an error if the attribute already exists, no replacement will occur.

Parameters: ParametersFields that can be passed to Add Attribute To calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Attribute Name? attr_name* Attribute Value? attr_data* Mask? mask

 

 

AddAttributeToUnits

Description: Adds an attribute to the specified unit serial number(s). This command will produce an error if the attribute already exists, no replacement will occur.

Parameters: ParametersFields that can be passed to Add Attribute To Units calls.  

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Attribute Name? attr_name* Attribute Value? attr_data* Mask? mask

 

 

AddComment

Description: Adds a comment checked against an optional mask to the scanned unit.

Parameters: ParametersFields that can be passed to Add Comment calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered

Comment Text?

comment_text*

Mask?

mask

 

 

AddCommentTo

Description: Adds a comment checked against an optional mask to the specified unit.

Parameters: ParametersFields that can be passed to Add Comment To calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Unit Part Number? unit_part_number Comment Text? comment_text* Mask? mask

 

 

AddConsumableBatchComponent

Description: ParametersFields that can be passed to Add Consumable Batch Component calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

Reference Designator?

ref_designator* Batch Serial Number? primary_batch_number* Batch Quantity? component_quantity* Component Id Mask? comp_id_mask Component Part Number?

   

 

AddConsumableNon-TrackedComponent

Description: ParametersFields that can be passed to Add Consumable Non-Tracked Component calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Reference Designator?

ref_designator* Batch Serial Number? component_id* Batch Quantity? component_quantity* Component Id Mask? comp_id_mask Component Part Number? comp_part_mask

 

 

AddCustomerReportTimeStamp

Description: Creates a timestamp to have serial info sent to the customer.

Parameters: ParametersFields that can be passed to Add Customer Report TimeStamp calls.

Prompt 

Value to be entered

Customer?

customer*

 

 

AddDefect

Description: Records a defect against the scanned unit. More streamlined input requirements than RecordDefect.

Parameters: ParametersFields that can be passed to Add Defect calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Defect Code?

defect_code* Ref Designator or N/A? ref_designator

Repair Code YES/NO/NFF/Code?

repair_code


 

AddDefinedAttribute

Description: Add Defined Attribute is equivalent to ATTADD in SFDC. Unlike SFDC it is designed to be used with the Conduit “Scanning Template” construct for units that have active/unreconciled Assembly / Attr_Def entries. AddMeasurementKey Add Measurement Key is equivalent to MEASKEY in SFDC.

 

AddMeasurementKey

Description: Adds a measurement key to the scanned unit.

 

AddMeasurementKeyTo

Description: Adds a measurement key to the specified unit.

Parameters: ParametersFields that can be passed to Add Measurement Key To calls.

Prompt

Value to be entered

Unit Serial Number?

unit_serial_number*

 

 

AddNon-SerializedToContainer

Description: Adds provided Non-Serialized to the scanned container serial.

Parameters: ParametersFields that can be passed to Add Non-Serialized To Container calls.

 

AddNon-TrackedAssemblyComponent

Description: Add Nontracked Assembly Component is a “Scanning Template” specific command for adding a non-tracked component based on an unreconciled assembly record for a unit. It is equivalent to ADCMP

 

AddNontrackedComponent

Description: Adds a non-tracked component to the scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.

Parameters: ParametersFields that can be passed to Add Non-Tracked Component calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Reference Designator?

ref_designator* Component Part Number? component_part_number Component Id? component_id* Component Id Mask? comp_id_mask

 

 

 

AddNon-TrackedComponentTo

Description: Adds a non-tracked component to the specified unit. Unlike Add Non-Tracked Component this does not require a scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.

Parameters: ParametersFields that can be passed to Add Non-Tracked Component To calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Reference Designator? ref_designator* Component Part Number? component_part_number Component Id? component_id* Component Id Mask? comp_id_mask

Warning: Using either of these AddNontrackedComponent/To commands multiple times for a given serial and ref_designator can result in multiple active components with the same ref_designator. In order to remove and replace an existing component for a serial/ref_designator, so that only one is active, you must use the ReplaceNontrackedComponent/To the version of these commands. 

 

 

AddPtsIDAssemblyComponent

Description: Adds a PTS ID component to the scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component is replaced.

 

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

Reference designator?

Enter the location of the component on the board Component ID? Component ID PTS ID Part Mask? If using a mask define it as not a mandatory value Component ID Mask?

 

AddToContainer

Description: Adds scanned unit serial number to the specified container serial.

Parameters: ParametersFields that can be passed to Add To Container calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Container Serial Number?

container_serial_number*

Container Part Number?

container_part_number

 

 

AddToLot

Description: Adds the scanned unit serial number to the specified lot.

Parameters: ParametersFields that can be passed to Add To Lot calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Lot Serial Number?

lot_serial_number*

Lot Part Number?

lot_part_number

 

 

 

AddToShopOrder

Description: Assign the scanned unit to a shop order.

Parameters: ParametersFields that can be passed to Add to Shop Order calls.

'Note:If the Shop Order is in status C (Closed) the following option needs to be enabled in the setup data editor 'CONDUIT_OPTIONS ALLOW_CHANGES_ON_CLOSED_WO=YES

Prompt

Value to be entered

New Shop Order Number?

new_shop_order_number*

   

AddTrackedAssemblyComponent

Description: Add Tracked Assembly Component is the tracked version of the Scanning Template enabled ADCMP command in SFDC.

 

AddTrackedComponent

Description: Adds a tracked or standard component to the scanned unit. This command will not replace an existing unremoved component with a matching <component id> but it will mark a previously removed component as replaced.

Parameters: ParametersFields that can be passed to Add Tracked Component calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Reference Designator?

ref_designator* Component Id? component_id* Component Workstation? workstation Component Part Number? component_part_number Component Id Mask? comp_id_mask

 

 

AddTrackedComponentTo

Description: Adds a tracked or standard component to the specified unit. This command will not replace an existing unremoved component with a matching <component id> but it will mark a previously removed component as replaced.

Parameters: ParametersFields that can be passed to Add Tracked Component To calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number* Reference Designator? ref_designator*

Component Id?

component_id*
Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered
Component Workstation? workstation Component Part Number? component_part_number Component Id Mask? comp_id_mask


Warning: Using either of these AddTrackedComponent/To commands multiple times for a given serial and ref_designator can result in multiple active components with the same ref_designator. In order to remove and replace an existing component for a serial/ref_designator, so that only one is active, you must use theReplaceTrackedComponent/To the version of these commands. 

 

AddUniqueAssemblyComponent

Description: Add Unique Assembly Component is the unique component version of the Scanning Template enabled ADCMP command in SFDC. AddUniqueComponent Add Unique Component has no corollary in SFDC today. It is designed to add a unique component without a predefined assembly record just like ADCMP2 (non-tracked) or ADCMP3 (tracked). AddUnitToContainer Add Unit To Container has no equivalent command in SFDC. SFDC Containerization essentially does the same thing via complicated mini-sessions executed after NEWCNTNR / OPENCNTNR.

 

 

AddUniqueComponent

Description: Creates and adds a unique component to the scanned unit. This command will not replace an existing unremoved component with a matching <component id> but it will mark a previously removed component as replaced.

Parameters: ParametersFields that can be passed to Add Unique Component calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Reference Designator?

ref_designator* Component Id? component_id* Component part number? component_part_number Component Id Mask? comp_id_mask

 

AddUnitsToShopOrder

Description: Attaches a unit to a shop order. The shop order must have room for the unit. 

Parameters: The serial number is changed to part/rev of the shop order following are the parameters or prompts.

Prompt 

Value to be entered Prompt Value to be entered

Unit Serial Number?

serial_number New Shop Order Number? shop_order_number

 

AddUnitToContainer

Description: Adds provided unit serial number to the scanned container serial.

Parameters: ParametersFields that can be passed to Add Unit To Container calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number*

Unit Part Number?

unit_part_number

 

 

AddUnitToLot

Description: Adds the provided unit serial number to the scanned lot.

Parameters: ParametersFields that can be passed to Add Unit To Lot calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number*

Unit Part Number?

unit_part_number

   

 

AdvancedShopOrderUnits

Description: Ends up to <unit limit> units for the supplied shop order number at the provided workstation. Units are chosen in FIFO order for the specified workstation. This command can be executed without a transaction unit.

Parameters: ParametersFields that can be passed to Advance Shop Order Units calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Shop Order Number?

shop_order_number* Workstation? workstation*

Unit Limit?

unit_limit

 

 

AppendMeasurement

Description: Find the most recent measurement key for the scanning process or add a new one if none exists and then record a measurement against it.

Parameters: ParametersFields that can be passed to Append Measurement calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Group?

groups_2* Step Name? steps_2*

Measurement?

values_2*

 

 

ApplyAlgorithmToUnit

Description: Change the provided unit serial number by applying the specified algorithm number to it.

Parameters: ParametersFields that can be passed to Apply Algorithm To Unit calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number*

Unit Part Number?

unit_part_number

 

 

ApplyMeo

Description: Applying Meo is equivalent to ADMEO.

 

ApplyMfgEngineeringOrder

Description: Adds a Manufacturing Engineering Order number to the scanned unit.

Parameters: ParametersFields that can be passed to Apply Mfg Engineering Order calls.

Prompt

Value to be entered

MEO Number?

meo_number*

 

 

AssertAttribute

Description: AssertAtribute validates that the attribute exists.

Parameters: The parameters to execute are:

  • Attribute Name: This is the name of the defined attribute to be compared.
  • No Op If Missing: This validates whether the attribute exists in the scanned serial number or not.

Note: If the attribute does not exist Conduit will send an error message.

  • Expression Operator:  Logic Expressions can be:
    • EQ  Equals to the expected value.
    • NE No equal to the expected value.
    • GT Greater than the low limit.
    • LT  Less than the high limit.
    • GE Greater than or equal to the low limit.
    • LE Less than or equal to the high limit.
    • GTLT Greater than the low limit and less than the high limit.
    • GELE Greater than or equal to the low limit and less than or equal to the high limit.
    • GTLE Greater than the low limit and less than or equal to the high limit.
    • GELT Greater than or equal to the low limit and less than the high limit.
    • LTGT  Less than the low limit and greater than the high limit.
    • LEGE Less than or equal to the low limit and greater than or equal to the high limit.
    • LTGE  Less than the low limit and greater than or equal to the high limit.
    • LEGT Less than or equal to the low limit and greater than the high limit.
    • CONTAINS Check if the tested value is within the expected item list.
  • First Comparator: The first value to compare with the current value.
  • Remaining Comparators: The list of the other values to be compared with the current value.
  • Error Message: The message that returns when the comparison between the value and the first comparator is not true.

Note: This command should not be used directly in Production Workbench, to execute this command, a Macro and an AutoCommand must be created previously at the Command Register.

The Figure below shows the AssertAttribute Macro calling the AutoCommand.

Figure 1: AssertAttribute Macro calling the AutoCommand

CCA AssertAttribute Macro calling the AutoCommand .png

  

 

AssertScanningUnit

Description: Helper operation to confirm the scanned serial number matches the checked serial number, typically a box label.

Parameters: ParametersFields that can be passed to Assert Scanning Unit calls.

Prompt

Value to be entered

Checked Serial Number?

unit_serial_number*

 

   

AssertStationUnitCount

Description: Counts the units at a specific location (Use packing stations to limit units to avoid mixing labels).

Conduit implementation of'VERQTY

Parameters: ParametersFields that can be passed to Assert Station Unit Count calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Check Location?

stationToCheck*

Unit Count Limit?

countLimit*

 

 

AssertValue

Description: Assert Value compares set values.

Parameters: The parameters to execute are:

  • Value: The current value to be compared.
  • Expression Operator: Logic Expressions can be:
    • EQ  Equals to the expected value.
    • NE No equal to the expected value.
    • GT Greater than the low limit.
    • LT  Less than the high limit.
    • GE Greater than or equal to the low limit.
    • LE Less than or equal to the high limit.
    • GTLT Greater than the low limit and less than the high limit.
    • GELE Greater than or equal to the low limit and less than or equal to the high limit.
    • GTLE Greater than the low limit and less than or equal to the high limit.
    • GELT Greater than or equal to the low limit and less than the high limit.
    • LTGT  Less than the low limit and greater than the high limit.
    • LEGE Less than or equal to the low limit and greater than or equal to the high limit.
    • LTGE  Less than the low limit and greater than or equal to the high limit.
    • LEGT Less than or equal to the low limit and greater than the high limit.
    • CONTAINS Check if the tested value is within the expected item list.
  • First Comparator: The first value to compare with the current value.
  • Remaining Comparators: The list of the other values to be compared with the current value. 
  • Error Message: The message that returns when the comparison between the value and the first comparator is not true.

Note: This command should not be used directly in Production Workbench, to execute this command, a Macro and an AutoCommand must be created previously at the Command Register.

The following Figures show how this attribute works in Command Register.

 Figure 2: Create a Macro

CCA Create a Macro.png

Figure 3: Create an Auto Command in a Prepend to call the previously created Macro (Figure 1)

CCA Create an Auto Command in a Prepend to call the previously created Macro (Figure 1).png

 

 

AssignDistinctNon-TrackedComponent

Description: Generate a component id from a specified algorithm number and add it as a non tracked component with a specified ref designator.

Parameters: ParametersFields that can be passed to Assign Distinct Nontracked Component calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Algorithm Number?

algo_number*

Reference Designator?

ref_des*


 

AssignIPV4MacAddress

Description: Generate IPV4 MAC address from specified algorithm number and add as non tracked component with specified ref designator.

Parameters: ParametersFields that can be passed to Assign IPV4 Mac Address calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Algorithm Number?

algo_number*

Reference Designator?

ref_des*

 


AssignMacAddresses

Description: Generate one or more MAC addresses using the specified algorithm number and add them as nontracked components on the scanned unit.

Parameters: ParametersFields that can be passed to Assign Mac Addresses calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Algorithm Number?

algorithm_number*

Count?

count*


 

AssignUnitsToNextShopOrder

Description: Assign the specified set of unit serial numbers to the oldest eligible shop orders.

Parameters: ParametersFields that can be passed to Assign Units To Next Shop Order calls.

Prompt

Value to be entered

Serial Number?

unit_serial_numbers*

 


B

BackgroundPrintLabel

Description: Schedules background printing of the specified label name for the scanned unit serial number to the specified print queue.

Parameters: ParametersFields that can be passed to Background Print Label calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Label Name?

label_name*

Print Queue?

print_queue*


 

C

ChangeContainerPartNumberAndAddAttributeOrComment

Description: Changes the part number of a container and adds an attribute or comment.

Parameters: ParametersFields that can be passed to Change Container Part Number And Add Attribute Or Comment calls.

 

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Container Serial Number?

container_serial_number* Route action: PRE, NEW, or CLR?

pre*

new*

clr*

New Part Number? new_part_number*

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Attribute Name?

attr_name* Attribute Value? attr_data* Comment Text? comment_text*

  

 

ChangePartNumber

Description: Changes the part number of the scanned unit.

Parameters: ParametersFields that can be passed to Change Part Number calls.

Prompt

Value to be entered

New Part Number?

new_part_number*


 

ChangeRevision

Description: Changes the revision for the scanned unit.

Parameters: ParametersFields that can be passed to Change Revision calls.

Prompt

Value to be entered

New Revision?

new_revision

 

 

ChangeSerialAlgorithm

Description: Generates a new unit id with the specified algorithm and changes the serial number of the scanned unit.

Parameters: ParametersFields that can be passed to Change Serial Algorithm calls.

Prompt

Value to be entered

Algorithm Number?

algorithm_number*

 

 

ChangeSerialNumber

Description: Changes the serial number of the scanned unit.

Parameters: ParametersFields that can be passed to Change Serial Number calls.

Prompt

Value to be entered

New Serial Number?

new_serial_number*

   

 

 

ChangeSerialToComponentId

Description: Conduit implementation of CHGIDREF

Verifies one component matching a specified reference designator is assigned to a serial number and runs a duplicate check on the component. If there is a component error, the command records a specified component error defect code against the component. 

If there is no component error then the serial number is changed to the component id found at the specified reference designator.

Parameters: ParametersFields that can be passed to Change Serial To Component Id calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Component Reference Designator?

refDesignatorToCheck*

Error Defect Code?

errorDefectCode*


 

 

ChangeUnit(s)ShopOrder

Description: Moves units at a specified location from one shop order to another. The command places a skeleton serial number as a placeholder in the original shop in order to keep counts correct.

Parameters: N/A

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number* New Shop Order Number? new_shop_order_number*

Source Unit Status?

source_unit_status_key*
Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered
Move To Location? destination* Source Workstation? source_workstation Force Common Shop Order Part Number? flag

 

Note:  If the option is set to true the command will allow entering a shop order with the same part number.

Warning: For a single unit use the command below,  for multiple units use the command above.

 

ChangeUnitShopOrder

Description: Removes the non-wip unit from its existing shop order and adds it to the specified shop order.

Parameters: ParametersFields that can be passed to Change Unit Shop Order calls.

Note: If the Shop Order is in status C (Closed) the following option needs to be enabled in the setup data editor CONDUIT_OPTIONS ALLOW_CHANGES_ON_CLOSED_WO=YES

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number* New Shop Order Number? new_shop_order_number*

Source Unit Status?

source_unit_status_key*
Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered
Move To Location? destination* Source Workstation? source_workstation Force Common Shop Order Part Number? flag

 

 

CheckAlgorithmOrderPoint

Description: Check if the order point threshold for the specified algorithm number has been achieved and initiate notification email(s) if necessary.

Parameters: ParametersFields that can be passed to Check Algorithm Order Point calls.

Prompt

Value to be entered

Algorithm Number?

algorithm_number*


 

CheckDefectBoardLocCount

Description: Records a defect and moves the unit if the specified board location has more than the provided limit/count defect(s).

Parameters: ParametersFields that can be passed to Check Defect Board Loc Count calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Fail Limit?

fail_limit* Board Location? board_loc* Move To Location? destination* Defect Code? defect_code*

 

 

CheckComponentCount

Description: Conduit implementation of CHKCMPQT.

Counts the number of components assigned to a serial number and compares that count to a specified count parameter. If the values do not match, the command passes the unit to a specified Fail location and records a W999 defect against the unit, else returns END to pass the unit to the next station.

Parameters: ParametersFields that can be passed to Check Component Count calls. 

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Expected Component Quantity?

expectedCount* Move Location? moveLoc*

Failure Defect Code?

failureDefectCode*


 

 

CheckDefectCount

Description: Count the number of defects matching the specified defect code and move to the Move To Location if the count matches or exceeds the specified max quantity.

Parameters: ParametersFields that can be passed to Check Defect Count calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Defect Code? defect_code* Max Qty? max_qty* Count NFF? (Y/N)


 

CheckFailureCount

Description: Count the number of failures and move to the Move To Location if the count matches or exceeds the specified max quantity.

Parameters: ParametersFields that can be passed to Check Failure Count calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Max Qty?

max_qty*

Move To Location?

move_to_loc*


 

CheckFromLocation

Description: Conduit implementation of CHECKFROM. Verifies the last location movement activity of the scanned serial number matches the specified check location.

Parameters: ParametersFields that can be passed to Check From Location calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Check Location?

stationToCheck*

Defect Code?

defectCode*

 

 

CheckIn

Description: Moves the units to the specified workstation. The move to the workstation can be supplied in shorter style (e.g., COMP) or long formats (e.g., COMP Complete).

Parameters: ParametersFields that can be passed to Check Incalls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Workstation?

workstation* Move Password? move_password

Unit Serial Number?

unit_serial_number

 

 

CheckOut

Description: Moves the units to the previous workstation, before check-in.

Parameters: ParametersFields that can be passed to Check Outcalls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Move Password?

move_password

Unit Serial Number?

unit_serial_number*


 

CheckProcessExits

Description: Conduit implementation of CHKPROCQ. Checks the quantity of pass/fail activities at all locations for a group of processes. The command requires a string specifying the processes to be checked. If the quantity of pass and fail activities equals or is greater than the value specified by the moveqty parameter, the unit is moved to the location specified by the moveloc parameter.

Parameters: ParametersFields that can be passed to Check Process Exits calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Threshold Reached Move Location?

moveLoc* Process To Check? processToCheck*

Pass/Fail Limit?

passFailLimit*

 

 

CheckShopOrderLocationIfExpired

Description: If there is no activity for that unit at the specific process/location or expired based on the duration refuse to add to the container.

Parameters: ParametersFields that can be passed to Check Shop Order Location If Expired calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Check Location?

workstation*

Delay Period?

duration*

 

 

CheckStationCycles

Description: Check the specified station for the number of trips through that station and compare it to the specific max and move it to the specified move to location when the value is exceeded.

Parameters: ParametersFields that can be passed to Check Station Cycles calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Check Location?

workstation* Move To Location? move_to_loc*

Max Qty?

max_qty


 

ClearMatchingAttributes

Description: Removes attributes that match the provided name/pattern from the scanned unit.

Parameters: ParametersFields that can be passed to Clear Matching Attributes calls.

Prompt

Value to be entered

Attribute Name?

attr_name*


 

ClearNon-MatchingAttributes

Description: Removes any attributes not matching the provided name/pattern from the scanned unit.

Parameters: ParametersFields that can be passed to Clear Non-Matching Attributes calls.

Prompt

Value to be entered

Attribute Name?

attr_name*


 

CloseContainer

Description: Changes the status of the scanned container serial number to Closed. Roughly equivalent to CLOSECNTNR.

Parameters: ParametersFields that can be passed to Close Container calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Container Serial Number?

container_serial_number*

Container Part Number?

container_part_number


 

CloseLot

Description:  Changes the status of the scanned lot serial to Closed.

Parameters: ParametersFields that can be passed to Close Lot calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Lot Serial Number?

lot_serial_number

Lot Part Number?

lot_part_number

 

ConditionalContainerization

Description: Check process activity and optionally verify the presence of the specified reference designator.

Parameters: ParametersFields that can be passed to Conditional Containerization calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Check Reference Designator(s)?

value Component Missing Defect Code? value_1 Process Missing Defect Code? value_2* Processes To Check? value_3*

 

 

ConsumeAlgorithm

Description: Invokes the specified algorithm number and returns the generated value.

Parameters: ParametersFields that can be passed to Consume Algorithm calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Algorithm Number?

algorithm_number*

Product Number?

unit_part_number

 

 

ConsumeNon-SerializedBatch

Parameters: ParametersFields that can be passed to ConsumeNonSerializedBatch calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Batch Serial Number?

primary_batch_number* Base Reference Designator? ref_designator*

Batch Quantity?

batch_quantity

 

ConsumeSitBatch

Description: Consume the specified quantity from the provided Sit Batch serial and add a non-tracked component matching the sit batch serial number to the scanned unit at the specified reference designator.

Parameters: ParametersFields that can be passed to Consume Sit Batch calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Reference Designator?

ref_designator* Batch Serial Number? primary_batch_number*

Consume Quantity?

consume_quantity*

 

 

CreateBatchSerial

Description: Creates a Batch Serial number with the provided serial number, batch quantity, and shop order number. Can be executed in place of a transaction unit.

Parameters: ParametersFields that can be passed to Create Batch Serial calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Shop Order Number?

shop_order_number* Batch Quantity? batch_quantity* Batch Serial Number? unit_serial_number* Revision? new_revision

 

 

CreateContainer

Description: Create a container with the provided serial number using supplied the c_level and part definition. This command can be supplied in place of a transaction unit.

Parameters: ParametersFields that can be passed to Create Container calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Container Level?

c_level* Container Part Number? container_part_number Container Serial Number? container_serial_number Project Id? proj_id

 


CreateGeneratedBatchSerial

Description: Creates a batch serial using the supplied quantity and shop order number. The actual batch serial number will be generated using provided algorithm. Can be executed in place of a transaction unit.

Parameters: ParametersFields that can be passed to Create Generated Batch Serial calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

Shop Order Number?

shop_order_number* Batch Quantity? batch_quantity* Algorithm Number? algorithm_number* Revision? new_revision Execute as Unit

 


CreateLot

Description: Create a lot with the provided serial number using supplied the c_level and part definition. This command can be supplied in place of a transaction unit.

Parameters: ParametersFields that can be passed to Create Lot calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Lot Part Number?

lot_part_number Lot Serial Number? lot_serial_number

Project Id?

proj_id


 

CreateUnit

Description: Creates and scans a unit serial number using the specified serial number generation algorithm.

Parameters: ParametersFields that can be passed to Create Unit calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Algorithm Number?

algorithm_number* Unit Part Number? unit_part_number*

Revision?

new_revision

 


D

 

DeallocateStationMaterial

Description: Deallocate any material for the specified part number at the specified location or the scanning location.

 

DeferUnitPrompts

Description: Answer NEXT to all assembly and attribute prompts relevant to the scanned unit at the scanning station/process.

 

E

 

END

Description: END is effectively identical to END in SFDC.

 

 

F

FindActiveShopOrder

Description: Identify the active shop order for the mfg line associated with the location.

 

FindAttribute

Description: Find an attribute matching the specified name for the scanned unit. By default not finding the attribute is an ERROR condition but that can be overridden via parameter.

Parameters: ParametersFields that can be passed to Find Attribute calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Attribute Name?

attr_name*

No Op If Missing?

no_op_if_missing


 

FindClientStations

Description: Finds client stations.

 

FindNextStationUnit 

Description: Finds the oldest unit at a station matching an optional part number and shop order number. The most recent unit at a station can be returned if LIFO (Last in, First out) is specified for the final parameter. 

 

FindParent

Description: Finds the immediate parent of the provided component serial number.

Parameters: ParametersFields that can be passed to Find Parent calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Component Serial Number?

component_serial_number

Error If Not Found?

error_if_not_found

 

 

FindPrinters

Description: Identify the printers currently available to the label engine.

 

FindUnitActivity

Description: Attempts to find the unit activity for the provided serial number and optional part number.

 

FindUnitAttribute

Description: Find an attribute matching the specified name for the scanned unit. By default not finding the attribute is an ERROR condition but that can be overridden via parameter

 

FindUnitStation

Description: Finds the workstation at which the specified unit resides (if any.)

Prompt

Value to be entered

Unit Serial Number?

unit_serial_number*

 

H

 

hpeftpComponentsExtractionOperation

Description: Extract the components in two different orders displayed into the generated file.

Parameters: ParametersFields that can be passed to hpeftp Components Extraction Operation calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Levels Deep?

levels_deep*

Order Display?

order_display*

 

I

 

IncreaseNon-SerializedBatchQuantity

Description: Increase quantity of a non serialized batch.

Parameters: ParametersFields that can be passed to Increase Non-Serialized Batch Quantity calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

Unit Serial Number?

unit_serial_number* Unit Part Number? part_number Employee Number? employee* New Quantity? new_quantity* Execute as Unit


 

IncrementaNumericalRevision

Description: Increment a numerical revision for the scanned unit.

Parameters: ParametersFields that can be passed to Increment numerical Revision calls. 

Prompt

Value to be entered

New Revision?

new_revision


 

InitializeMeasurementKey

Description: Find the most recent measurement key for the scanning process or add a new one if none exists.  

 

InitializePrinter

Description: Initializes printer graphics for all labels of the specified label type.

Parameters: ParametersFields that can be passed to Initialize Printer calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Label Type?

label_type*

Print Queue?

print_queue*


 

InitiateMaterialNon-Conformance

Description: Creates a non-conforming material against the specified material part number and optional serial number defect.

Parameters: ParametersFields that can be passed to Initiate Material Non Conformance calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Material Part Number?

material_part_number* Material Identifier? material_id

Defect Serial Number?

unit_serial_number
Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered
Defect Sequence? unit_defect_seq Parent Serial Number? parent_serial_number External Reference Number? external_reference_number

 

 

InsuletPrintLabel

Description: Print Label from Label Engine Print History if any it was already printed based on the LOT#, if not then print label getting values from Target Maintenance.

Parameters: ParametersFields that can be passed to Insulet Print Label calls. 

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Lot Number?

lot_number* Flex Field? flex_field*

Print Queue?

print_queue*

 

 

K
 

KillIfDuplicated

Description: Move the unit into the specified kill location if the first <match_size> characters of the scanned unit id match any existing or archived serial numbers.

Parameters: ParametersFields that can be passed to Kill If Duplicated calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Kill Location?

workstation*

Match Size?

match_size


 

L

 

LinkDefect

Description: Associates or links a defect from the specified serial number to another defect on the same or alternate serial number if the link does not already exist.

Parameters: ParametersFields that can be passed to Link Defect calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

From Serial Number?

from_serial_number* From Defect Sequence? from_defect_seq* To Serial Number? to_serial_number To Defect Sequence? to_defect_seq*


 

LinkMedia

Description: Links a media reference identifier to an existing activity for a serial number.

 

M

 

MergeBatchSerial

Description: Merge the provided batch serial number into the scanned batch unit.

Parameters: ParametersFields that can be passed to Merge Batch Serial calls.

Prompt

Value to be entered

Merge Serial Number?

merge_serial_number*

 

 

MOVE

Description: Moves the scanned unit to the specified workstation. The move to the workstation can be supplied in shorter style (e.g., COMP) or long formats (e.g., COMP Complete).

Parameters: ParametersFields that can be passed to Move calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Workstation?

workstation*

Move Password?

move_password

 

 

MoveFromHold

Description: Conduit implementation of MOVEFROMHOLD.

Parameters: ParametersFields that can be passed to Move From Hold calls.

Prompt

Value to be entered

Serials To Move?

serialsToMove*


 

MoveIfAttributeData

Description: Conduit implementation of MOVEIFATT.

Parameters: ParametersFields that can be passed to Move If Attribute Data calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Attribute Name To Check?

checkAttrName* Expected Attribute Value? checkAttrData*

Move Location?

moveLoc*


 

MoveIfComponentAt

Description: Moves the scanned unit to the specified destination when the specified reference designator exists as a component.

Parameters: ParametersFields that can be passed to Move If Component At calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Reference Designator?

ref_designator*

Destination Workstation?

destination*


 

MoveIfMissingComponent

Description: Conduit implementation of MOVEIFNOREF.

If the command does not find an active component with ref_designator matching ref param, then it moves the unit to the location specified in moveloc param.

Parameters: ParametersFields that can be passed to Move If Missing Component calls. 

Prompt  Value to be entered

       Prompt       

Value to be entered

Reference Designator To Check?

refDesignatorToCheck*

Move Location?

moveLoc*


 

MoveIfRef

Description: Conduit implementation of MOVEIFREF.

Parameters: ParametersFields that can be passed to Move If Ref calls. 

Prompt  Value to be entered

       Prompt       

Value to be entered

Ref Designator To Check?

refDesignatorToCheck*

Move Location?

moveLoc*


 

MoveUnitTo

Description: Moves the units to the specified workstation. The move to the workstation can be supplied in shorter style (e.g., COMP) or long formats (e.g., COMP Complete).

Parameters: ParametersFields that can be passed to Move Unit To calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Workstation?

workstation* Move Password? move_password

Unit Serial Number?

unit_serial_number*

 

O

 

OpenContainer

Description: Change the status of the scanned container serial number to Open.

Parameters: ParametersFields that can be passed to Open Container calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Container Serial Number?

container_serial_number*

Container Part Number?

container_part_number

   

OpenLot

Description: Changes the status of a lot to Open. Do not initiate lot serial scanning like OPEN LOT.

 

 

P

PCBRJCT

Description: Designate a quantity that wants to record a defect. It records a comment but no activity and records the data in the serdef record for the Quality Collection Plan (QCP).  It stays at the current location without ending.

Enter the requested information such as defect_code, charge dept,  quantity, comment and disposition.

Defect Code

Dxxx

Charge Dept

Text

Quantity

Numeric

Disposition

“Rework” / “None”

Acc

Numeric

Rej

Numeric

Serial# (Dnote)

Alphanumeric

NCMR Comment

Alphanumeric

Fail Workstation/Rework Operation

Alphanumeric

 

 

PCBRWRK 

Description: This command will send the units to Rework locations (out of the standard route) and will also allow us to move units with not flow control through the route. It creates a comment record but no activity, and records the data in the serdef record.  If the disposition is SCRAP or the fail workstation is RJCT, the unit stays at current location without ending, else is moved to the fail workstation.

Enter the requested information such as defect_code, charge dept,  quantity, disposition, comment and fail workstation.

Defect Code

Dxxx

Charge Dept

Text

Quantity

Numeric

Disposition

“Rework” / “None”

Acc

Numeric

Rej

Numeric

Serial# (Dnote)

Alphanumeric

NCMR Comment

Alphanumeric

Fail Workstation/Rework Operation

Alphanumeric

 

 

PCBSCRP

Description: This command will designate a quantity that wants to record a B defect for, along with some relevant information to be stored with the defect data.  If the quantity is less than the current NS sub batch, it splits off the requested quantity and then records the data in the serdef record (for the QCP).  The NS batch is then moved to SCRP location. It also supports recording multiple defects for the scrap operation. 

Enter the requested information such as defect_code, charge dept and defect quantity.

Defect Quantity?

Numeric

Defect Code

Bxxx

Charge Dept

Text

 

PlaceHold

Description: Adds hold according to the rules specified.

Parameters: ParametersFields that can be passed to Place Hold calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Employee Number?

employee* Unit Serial Number? hold_serial_number Unit Part Number? hold_part_number Shop Order Number? hold_shop_order

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Workstation?

hold_location Process Name? hold_process_name User Defined? user_defined Comment Text? comment_text

 

 

PrepareContainerMultilevel

Parameters: ParametersFields that can be passed to Prepare Container Multilevel calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

Container or Unit Serial Number?

container_serial_number Container Level? c_level Project Id? proj_id Container Part Number? container_part_number Execute as Unit


 

PrepareUnitContainer

Description: Depending on the type of unit provided either create a container and add the specified unit to it or open the container in preparation for adding more units. This command can be supplied in place of a transaction unit.

Parameters: ParametersFields that can be passed to Prepare Unit Container calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

Container or Unit Serial Number?

container_serial_number Container Level? c_level Project Id? proj_id Container Part Number? container_part_number Execute as Unit

 

 

PrintAlgorithmUnits

Description: Generate and print the <count> units using the specified algorithm, label name, and print queue.

Parameters: ParametersFields that can be passed to Print Algorithm Units calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

Algorithm Part Number?

algorithm_part_number* Algorithm Number? algorithm_number* Label Name? label_name* Print Queue?

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt

print_queue*

Quantity? new_quantity Max Qty? max_qty Calibration? calibration

 

 

PrintCaseLabel

Description: Unified label printing command for both label engine and legacy labels based on the provided label_name (or label_type). Operates either on the scanned unit or specified unit serial number(s).

Parameters: ParametersFields that can be passed to Print Label calls. 

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Label Name?

label_name* Print Queue? print_queue*

Algorithm Number?

algorithm_number*


 

PrintDemoLabel

Description:  Print a demo label name for the currently scanned unit serial number to the specified print queue.

 

PrintLabel

Description: Unified label printing command for both label engine and legacy labels based on the provided label_name (or label_type). Operates either on the scanned unit or specified unit serial number(s).

Parameters: ParametersFields that can be passed to Print Label calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Label Name (or Type)?

label_name* Print Queue? print_queue* Test Print? test_print Unit Serial Number(s)? unit_serial_numbers


 

Print Legacy Label

Description: Print the specified legacy label type for the currently scanned unit serial number to the specified print queue.

Parameters: ParametersFields that can be passed to Print Legacy Label calls.

Prompt  Value to be entered

       Prompt       

Value to be entered

Label Type?

label_type*

Print Queue?

print_queue*


 

 

 

 

 

R

 

ReadLastStandardOrderBOM

Description: Identify the last standard order the unit was assigned and attempt to read the specified reference designator(s).

Parameters: ParametersFields that can be passed to ReadLastStandardOrderBOM calls.

Prompt

Value to be entered

Reference Designator(s)?

value


 

ReconcileAssemblyComponent

Description: Validate assembly specified component and reference designator along with custom flags.

Parameters: ParametersFields that can be passed to Reconcile Assembly Component calls. 

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Accept Same Component?

value* Replace Existing Component? value_1* Component Id To Check? value_2* Component Reference Designator? value_3*

 

 

ReconcileComponentMFGHolds

Description: Traverses the entire component tree and checks to see if a component serial is on hold. RecordDefect Records a defect against a unit. Equivalent to RCDFC in SFDC.

 

 

RecordDefect

Description: Records a defect against the scanned unit.

Parameters: ParametersFields that can be passed to Record Defect calls.

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Defect Code?

defect_code* Defect Quantity? defect_quantity Ref Designator or N/A? ref_designator Pin 1? pin1

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Pin 2?

pin2 Surface? surface Defective Part or N/A? defective_part_number Manufacturer? manufacturer

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Manufacturer Lot Code?

manufacturer_lot_code Repair Code YES/NO/NFF/Code? repair_code Tracked Component Position? component_position Linked Defect Repair Code? linked_repair_code


 

RecordDefectTo

Description: Records a defect against the specified unit serial number.

Parameters: ParametersFields that can be passed to Record Defect To calls. 

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Defect Code? defect_code* Defect Quantity? defect_quantity Ref Designator or N/A? ref_designator

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Pin 1?

pin1 Pin2? pin2 Surface? surface Defective Part or N/A? defective_part_number

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered    

Manufacturer?

manufacturer Manufacturer Lot Code? manufacturer_lot_code Repair Code YES/NO/NFF/Code? repair_code    


 

RecordMedia

Description: Records a media activity against the scanned unit with the specified media reference identifier.

Parameters: ParametersFields that can be passed to Record Media calls. 

Prompt

Value to be entered

Media Identifier(s)?

media_identifier*

 

 

RecordMonitoredMeasurement

Description: Record the measurement and notify SPC of the measurement.

Parameters: ParametersFields that can be passed to Record Monitored Measurement calls.  

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

SPC Monitor Name?

monitorName* Attribute Name? attributeName* Attribute Value?

Prompt 

Value to be entered Prompt  Value to be entered Prompt 

attributeValue*

Lot Number? lotNumber Note(s)? note

 

 

RecordValidatedDefects

Description: Record one or more defects with the specified defect code and reference designator(s).

Parameters: ParametersFields that can be passed to Record Validated Defects calls. 

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Defect Code?

defectCodeToRecord* Defect Quantity? defect_quantity Reference Designator(s)? designatorText Pin 1? pin1

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Pin 2?

pin2 Surface? surface Manufacturer? manufacturer Manufacturer Lot Code? manufacturer_lot_code

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered    

Repair Code YES/NO/NFF/Code?

repair_code Tracked Component Position? component_position Linked Defect Repair Code? linked_repair_code    

 

 

RegexMatch

Description: Applies the provided regular expression to the specified value returning OK if it matches and either or NO-OP as specified.

 

RegexReplace

Description: Replaces substrings that match the regular expression with the replacement string.

 

RejectIfDefective

Description: Moves scanned unit to the relevant failure location if any unrepaired defects exist on that unit at all, otherwise, do nothing. 

 

RejectDefectiveUnit

Description: Reject if the unit has any defect not repaired.  

 

RejectIfDefective

Description: Move the scanned unit to the relevant failure location if any unrepaired defects exist on that unit at all, otherwise do nothing.  

 

RejectIfDuplicateComponent

Description: Record the specified defect and End the unit if there is no component at the specified reference designator or that designator exists on another unit.

Parameters: ParametersFields that can be passed to Reject If Duplicate Component calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Reference Designator?

ref_designator

Defect Code?

defect_code


 

RejectIfHasAnAttribute

Description: Reject if has an attribute.

Parameters: ParametersFields that can be passed to Reject if has an attribute calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Attribute Name?

attr_name*

Attribute Value?

attr_data

 

 

RejectIfMissingAttribute

Description: Records a defect and performs an End or Move To the provided reject location if the attribute definition for the scanned unit with the provided attribute name is unresolved.

Parameters: ParametersFields that can be passed to Reject If Missing Attribute calls. 

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Attribute Name?

attr_name* Reject Location? reject_location

Defect Code?

defect_code

 

 

RejectIfMissingAttributes

Description: Record a defect and either End or Move To the provided reject location if any attribute definitions for the scanned unit are unresolved.

Parameters: ParametersFields that can be passed to Reject If Missing Attributes calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Reject Location?

reject_location

Defect Code?

defect_code


 

RejectIfMissingComponent

Description: Conditionally fails the unit if the specified reference designator and component id are not present on the scanned unit.

Parameters: ParametersFields that can be passed to Reject If Missing Component calls. 

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Defect Code?

defect_code* Reference Designator? ref_designator* Component Id? component_id Maximum Tries? max_tries

 

 

RejectIfMissingComponents

Description: Records a defect and performs an End or Move To the provided reject location if the scanned unit has any unresolved assembly definitions.

Parameters: ParametersFields that can be passed to Reject If Missing Components calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Reject Location?

reject_location

Defect Code?

defect_code


 

RejectIfMissingProcessAttributes

Description: Records a defect and performs an End or Move To the provided reject location if any attribute definitions for the scanned unit at the supplied process name are unresolved.

Parameters: ParametersFields that can be passed to Reject If Missing Process Attributes calls. 

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Process Name?

prompted_process_name* Reject Location? reject_location

Defect Code?

defect_code

 

 

RejectIfMissingTreeComponentAt

Description: Records a defect using the specified defect code and advances the scanned unit when the specified reference designator does not exist as a component anywhere in the unit's component hierarchy.

Parameters: ParametersFields that can be passed to Reject If Missing Tree Component At calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Defect Code?

defect_code* Component Id? component_id*

Reference Designator?

ref_designator*

 

 

RejectIfNoShopOrder

Description: Records a defect and fails the scanned unit if it is not assigned to a shop order.

Parameters: ParametersFields that can be passed to Reject If No Shop Order calls.

Prompt

Value to be entered

Defect Code?

defect_code*

 

 

RejectIfTimeExpired

Description: Record the specified defect and optionally Move the unit to the move to a location if there is no activity for that unit at the specified process/location.

Parameters: ParametersFields that can be passed to Reject If Time Expired calls. 

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Check Location/Process?

workstation* Defect Code? defect_code* Duration (minutes)? minute_duration* Move To Location? move_to_loc

 

 

RemoveAllComponents

Description: Removes all components from a unit. Equivalent to RMCMPALL.

 

RemoveAllElementsFromContainer

Description: Removes All Elements from the provided container serial.

Parameters: ParametersFields that can be passed to Remove All Elements From Container calls.

Prompt

Value to be entered

Container Serial Number?

container_serial_number*

 

 

RemoveAttribute

Description: Removes the specified attribute from the scanned unit. Similar to ATTREMOVE but only operates on a single attribute.

Parameters: ParametersFields that can be passed to Remove Attribute calls.

Prompt

Value to be entered

Attribute Name?

attr_name*

 

 

RemoveAttributes

Description: Removes a component of any type matching the provided <component id> from the scanned unit.

Parameters: ParametersFields that can be passed to Remove Component calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number*

Attribute Name?

attr_name*

  

 

RemoveComponent

Description: Removes a component of any type matching the provided <component id> from the scanned unit.

Parameters: ParametersFields that can be passed to Remove Component calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Component Id?

component_id*

Destination?

destination

 

 

RemoveComponentAt

Description: Removes a single existing component with a matching <reference designator> if one exists.

Parameters: ParametersFields that can be passed to Remove Component At calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Reference Designator?

ref_designator*

Destination?

destination


 

RemoveComponentFrom

Description: Removes a component of any type matching the provided <component id> from the specified unit.

Parameters: ParametersFields that can be passed to Remove Component From calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number* Component Id? component_id*

Destination?

destination

 

 

RemoveComponentsAt

Description: Removes all components with a matching <reference designator> if any exist.

Parameters: ParametersFields that can be passed to Remove Components At calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Reference Designator?

ref_designator*

Destination?

destination


 

RemoveDefectiveComponent

Description: Remove a tracked component from the scanned unit and record a defect against it.

Parameters: ParametersFields that can be passed to Remove Defective Component calls. 

Prompt 

Value to be entered Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Bad Component Id?

component_id_1* Destination? destination_4 Defect Code? defectCodeToRecord_6* Defect Quantity? defect_quantity_6
Prompt Value to be entered Prompt Value to be entered Prompt Value to be entered

Prompt

Value to be entered

Reference Designator(s)?

designatorText_6 Pin 1? pin1_6 Pin 2? pin2_6 Surface? surface_6
Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Manufacturer?

manufacturer_6 Manufacturer Lot Code? manufacturer_lot_code_6 Repair Code YES/NO/NFF/Code? repair_code_6 Tracked Component Position? component_position_6

Prompt

Value to be entered            

Linked Defect Repair Code?

linked_repair_code_6            


 

RemoveFromLot

Description: Removes the scanned unit from any lot it may be assigned to.  

 

 

RemoveFromShopOrder

Description:  Removes a scanned serial number from the current shop order, no parameters required.

Note: If the Shop Order is in status C (Closed) the following option needs to be enabled in the setup data editor CONDUIT_OPTIONS ALLOW_CHANGES_ON_CLOSED_WO=YES

Prompt 

Value to be entered

       Prompt       

Value to be entered

N/A

serial_number

N/A

N/A

   

 

RemoveNon-SerializedFromContainer

Description: Remove non-serialized from the scanned container serial.

Parameters: ParametersFields that can be passed to Remove Non-Serialized From Container calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered

Unit Part Number?

unit_part_number*

Quantity?

unit_quantity*

   

 

RemoveProcessAttributes

Description: Removes any attributes defined for addition at the provided process from the scanned unit.

Parameters: ParametersFields that can be passed to Remove Process Attributes calls.

Prompt

Value to be entered

Process Name?

prompted_process_name*

 

 

RemoveProcessComponents

Description: Removes any components defined for addition at the provided process from the scanned unit.

Parameters: ParametersFields that can be passed to Remove Process Components calls. 

Prompt

Value to be entered

Process Name?

prompted_process_name*

 

 

RemoveUnitFromContainer

Description: Removes provided unit serial number from the scanned container serial.

Parameters: ParametersFields that can be passed to Remove Unit From Container calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number*

Unit Part Number?

unit_part_number

 

 

RemoveUnitFromLot

Description: Removes the provided unit serial number from the scanned lot serial.

Parameters: ParametersFields that can be passed to Remove Unit From Lot calls.

 

RemoveUnitFromReworkShopOrder

Description: Rework rules are not the same as standard shop orders.  

 

 

RemoveUnitFromTree

Description: Removes tracked component matching the provided Component Serial Number and reference designator from its immediate parent placing it in the provided destination location. The command also adds a comment to the top-level parent in the component hierarchy.

Parameters: ParametersFields that can be passed to Remove Unit From Tree calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Component Serial Number?

unit_serial_number* Reference Designator? ref_designator*

Destination?

destination

 

RemoveUnitsFromShopOrder

Description: Removes a  unit from a shop order, and a skeleton serial record (status 64) is created in the shop order. The command will keep prompting for the next unit serial number until the shop order is empty(done) or the end is scanned?

Parameters: N/A

Prompt 

Value to be entered Prompt Value to be entered

Serial Number?

serial_number Shop Order Number? shop_order_number

RenderLabel

Description:  Signal the label engine service to render a printable label and download it to a local temporary file. Note: the downloaded file is only guaranteed to exist for the duration of the request session.

 

RepairAllDefects

Description: Repairs all defects with the provided repair code against the scanned unit.

Parameters: ParametersFields that can be passed to Repair All Defects calls.

Prompt

Value to be entered

Repair Code YES/NO/NFF/Code?

repair_code*


 

 

RepairDefect

Description: Repairs the provided defect sequence against the scanned unit.

Parameters: ParametersFields that can be passed to Repair Defect calls.

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Defect Sequence to Repair?

repair_defect_seq* Repair Code/YES/NFF? repair_code Repair Quantity? repair_quantity Linked Defect Repair Code? linked_repair_code

 

 

RepairDefectCode

Description: Repairs all defects matching the provided defect code against the scanned unit.

Parameters: ParametersFields that can be passed to Repair Defect Code calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Defect Code to Repair?

defect_code* Repair Code/YES/NFF? repair_code*

Repair Quantity?

repair_quantity

 

 

ReplaceAttribute

Description: Replaces an attribute (if one exists) and adds one to the scanned unit.

Parameters: ParametersFields that can be passed to Replace Attribute calls. 

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Old Attribute Name?

old_attr_name* Attribute Name? attr_name* Attribute Value? attr_data* Mask? mask

 

 

ReplaceAttributeOn

Description: Replaces an attribute (if one exists) and adds one to the specified unit serial number.

Parameters: ParametersFields that can be passed to Replace Attribute On calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Unit Serial Number?

unit_serial_number* Old Attribute Name? old_attr_name*

Attribute Name?

 

 

ReplaceComponent

Description: Replaces a component at the provided <component id> on the scanned unit with a new component.

Parameters: ParametersFields that can be passed to Replace Component calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Old Component Id?

old_component_id

Component Id?

component_id*

 

 

ReplaceComponentAt

Description: Replaces a component at the provided <reference designator> on the scanned unit with a new component.

Parameters: ParametersFields that can be passed to Replace Component At calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Reference Designator?

ref_designator*

Component Id?

component_id*


 

ReplaceConsumedNon-SerializedBatch

Parameters: ParametersFields that can be passed to ReplaceConsumedNonSerializedBatch calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered

Batch Serial Number?

primary_batch_number*

Reference Designator?

ref_designator*

 

 

ReplaceNon-TrackedAssemblyComponent

Description: Replace a previously existing “Scanning Template” non-tracked component with a new one.

 

 

ReplaceNon-TrackedComponent

Description: Replaces an existing non-tracked component with a matching <component id> (if one exists) and adds a new non-tracked component.

Parameters: ParametersFields that can be passed to Replace Non-Tracked Component calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Old Component Id?

old_component_id Reference Designator? ref_designator*

Component Id?

Prompt 

Value to be entered Prompt  Value to be entered Prompt 

component_id

Component Part Number? component_part_number Component Id Mask? comp_id_mask

 

 

ReplaceNon-TrackedComponentAt

Description: Replaces an existing non-tracked component with a matching <reference designator> (if one exists) and adds a new non-tracked component.

Parameters: ParametersFields that can be passed to Replace Non-Tracked Component At calls.

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Reference Designator?

ref_designator* Component Id? component_id* Component Part Number? component_part_number Component Id Mask? comp_id_mask

 


ReplaceNon-TrackedComponentOn

Description: Replaces an existing non-tracked component on the specified unit serial number with a matching <component id> (if one exists) and adds a new non-tracked component.

Parameters: ParametersFields that can be passed to Replace Non-Tracked Components On calls.

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Value to be entered

Unit Serial Number?

unit_serial_number* Old Component Id? old_component_id

Reference Designator?

ref_designator*

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Component Id?

component_id Component Part Number? component_part_number Component Id Mask? comp_id_mask

 

 

ReplaceOnBoardPTSComponent

Description: Replace an onboard PTS component that includes in its information fields: Site Id, Component Id, Reference Designator, and Remark to send it as an API call to PTS through Production Workbench.

 

 

ReplaceTimeSeriesAttribute

Description: Replaces a time series attribute (if one exists) and adds one to the scanned unit.

Parameters: ParametersFields that can be passed to Replace Time Series Attribute calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Mask?

mask

Data ID(s)?

data_id*


 

ReplaceTrackedAssemblyComponent

Description: Replace a preexisting “Scanning Template” tracked component with a new one.

 

ReplaceTrackedComponent

Description: Replaces an existing tracked component with a matching <component id> (if one exists) and adds a new tracked component.

Parameters: ParametersFields that can be passed to Replace Tracked Component calls.  

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Reference Designator?

ref_designator* Component Workstation? workstation Component Id? component_id*

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Component Part Number?

component_part_number Old Component Id? old_component_id Component Id Mask? comp_id_mask

 

 

ReplaceTrackedComponentAt

Description: Replaces an existing tracked component with a matching <reference designator> (if one exists) and adds a new tracked component.

Parameters: ParametersFields that can be passed to Replace Tracked Component At calls.  

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Reference Designator?

ref_designator* Component Workstation? workstation

Component Id?

Prompt

Value to be entered Prompt Value to be entered Prompt

component_id*

Component Part Number? component_part_number Component Id Mask? comp_id_mask


 

ReplaceTreeComponent 

Description: Replace a tree component starting from the scan serial number/ subassembly, this applies to any level of hierarchy.

 

ReplaceUniqueComponent

Description: Replaces an existing unique component with a matching <component id> (if one exists) and adds a new unique component. Because these are unique components the associated component serials will be deleted/created during this operation.

Parameters: ParametersFields that can be passed to Replace Unique Component calls. 

Prompt 

Value to be entered Prompt Value to be entered

       Prompt       

Old Component Id?

old_component_id Reference Designator? ref_designator*

Component Id?

Prompt

Value to be entered Prompt Value to be entered Prompt

component_id*

Component Part Number? component_part_number Component Id Mask? comp_id_mask


 

ReplaceUniqueComponentAt

Description: Replaces an existing unique component with a matching <reference designator> (if one exists) and adds a new unique component. Because these are unique components the associated serial records will be deleted/created during this operation.

Parameters: ParametersFields that can be passed to Replace Unique Component At calls.  

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Reference Designator?

ref_designator* Component Id? component_id* Component Part Number? component_part_number Component Id Mask? comp_id_mask


 

ReplaceUnitComponent

Description: Replaces a component at the provided <component id> on the specified unit with a new component.

Parameters: ParametersFields that can be passed to Replace Unit Component calls. 

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Old Component Id? old_component_id Component Id? component_id*


 

ReplaceUnitTreeComponent

Description: Replace a tree component starting from the specified top-level unit serial number, this applies to any level of hierarchy.

 

ReprintLabel

Description: Unified label (re)printing command for both label engine and legacy labels based on the provided label_name (or label_type). Operates either on the scanned unit or specified unit serial number(s).

Parameters: ParametersFields that can be passed to Reprint Label calls. 

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Label Name?

Label_name*

Print Queue? print_queue* Test Print? test_print

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number(s)?

unit_serial_numbers Approver? approver* Reprint Notes? notes*

Prompt

Value to be entered Prompt Value to be entered    

Reason Code?

reason_code* Reprint Password? reprint_password    

 

 

ReprintLegacyLabel

Description: Reprint the specified legacy label type for the specified unit serial number to the specified print queue.

Parameters: ParametersFields that can be passed to Reprint Legacy Label calls. 

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Label Type? label_type* Print Queue? print_queue* Reprint Password? reprint_password

 

 

RESCAN

Description: Conduit implementation of RESCAN.

 

 

RestoreLegacyArchiveUnit

Restores serial numbers that have been archived.

 

RestoreUnit

Description: Restores a Killed or Scrapped unit at the specified source workstation to the specified destination workstation.

Parameters: ParametersFields that can be passed to Restore Unit calls.  

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Unit Serial Number?

unit_serial_number* Source Workstation? source_workstation* Destination Workstation? destination_workstation* Unit Part Number? unit_part_number


 

ReturnUnitFromHold

Description: Conduit implementation of MOVEFROMHOLD

Parameters: ParametersFields that can be passed to Return Unit From Hold calls. 

Prompt

Value to be entered

Unit(s) to Return?

serialsToMove*

 

 

ReturnUnitToPrevious

Description: Returns the unit to the location it was moved to prior to its arrival at the current station.

Parameters: ParametersFields that can be passed to Return Unit To Previous calls.

Prompt

Value to be entered

Unit(s) to Return?

serialsToMove*


 

ReturnUnitToWIP

Description: Conduit implementation of BACK2WIP2.

Parameters: ParametersFields that can be passed to Return Unit To WIP calls. 

Prompt

Value to be entered

Unit(s) to Return To WIP?

serialsToMove*

 

 

S

 

SampleUnit

Description: Samples a unit based upon a configured sample master/plan. The unit will either be moved to the sample location if eligible or Ended (passed/failed) to the next location in the route.

Parameters: ParametersFields that can be passed to Sample Unit calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered

Skip End On NO-OP?

skip_end_on_no_op

Master Name?

master_name

 

 

ShippedContainer

Description: Mark all of the units in a container as having a shipped unit status.

Parameters: ParametersFields that can be passed to Shipped Container calls.  

Prompt

Value to be entered

Container Serial Number?

container_serial_number*

 

 

SignalSPCMonitor

Description: Schedule consumption of the continuous data monitor endpoint in SPC.

Parameters: ParametersFields that can be passed to Signal SPC Monitor calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt

SPC Monitor Name?

monitorName*

Attribute Name?

attributeName* Attribute Value?

Prompt

  Prompt    Prompt 

attributeValue*

Lot Number? lotNumber Note(s)? note

 

 

SplitBatchSerial

Description: Splits the provided quantity number of components from the scanned batch unit. The split batch will be created using the supplied serial number.

Parameters: ParametersFields that can be passed to Split Batch Serial calls.  

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt Value to be entered

Split To Serial Number?

split_to_serial_number*

Split Quantity?

new_quantity* Source Unit Strategy? source_unit_strategy*

 

 

SplitEntirePanel

Description: Splits the scanned unit (panel) using the provided array of serial numbers. If the count of the serial number(s) provided does not match the panel quantity the command will fail.

Parameters: ParametersFields that can be passed to Split Entire Panel calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered

Split To Serial Numbers?

split_to_serial_number

Panel Positions?

panel_position

 

 

SplitGeneratedBatchSerial

Description: Splits the provided quantity number of components from the scanned batch unit. The split batch will be created using a serial number generated from the supplied algorithm.

Parameters: ParametersFields that can be passed to Split Generated Batch Serial calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt Value to be entered

Algorithm Number?

algorithm_number*

Split Quantity?

new_quantity* Source Unit Strategy? source_unit_strategy*

 

 

SplitPanel

Description:  Splits the scanned unit (panel) using the provided serial number and quantity.

Parameters: ParametersFields that can be passed to Split Panel calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered

Split To Serial Numbers?

split_to_serial_number

Panel Position?

panel_position

 

 

SplitPanelAlgorithm

Description: Splits the scanned unit (panel) using the provided algorithm to generate up to count serial numbers.

Parameters: ParametersFields that can be passed to Split Panel Algorithm calls. 

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt

Algorithm Number?

algorithm_number*

Count?

count Label Name?

Prompt 

Value to be entered Prompt  Value to be entered Prompt 

label_name

Print Queue? print_queue Panel Positions? panel_position

 

 

StoreMedia

Description: Uploads the contents of the specified media file or parameter to the media service for long-term storage.

 

 

T

 

Touch Units

Description: Conduit implementation of TOUCH_UNIT

Marks a group of units so they will NOT be cleaned up by the clean-up-wip process. The command prompts for serial numbers. If the unit is Work-In-Process, a comment is created in the unit history and the record is updated with the current date and time.

Parameters: ParametersFields that can be passed to Touch Units calls. 

Prompt

Value to be entered

Unit(s) To Touch?

unitsToTouch*


 

U

 

UnitActivity

Description: Returns the unit history for the scanned unit.

Parameters: ParametersFields that can be passed to Unit Activity calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered

Process Name(s)?

processes

Action Code(s)?

action_codes

 

 

UnlinkDefect

Description: Removes the link between the specified defects if a link exists.

Parameters: ParametersFields that can be passed to Unlink Defect calls. 

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

From Serial Number?

from_serial_number* From Defect Sequence? from_defect_seq* To Serial Number? to_serial_number To Defect Sequence? to_defect_seq*

 

 

UnpackContainerUnits

Description: Removes all units from the container serial and adds an optional defect a configurable comment per unit and moves the unit to the specified workstation.

Parameters: ParametersFields that can be passed to Unpack Container Units calls.  

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt Value to be entered

Move To Location?

workstation*

Defect Code?

defect_code Comment Text? comment_text

 

 

V

ValidateDate

Description: Validate the specified date is within the specified date range.

Parameters: ParametersFields that can be passed to Validate Date calls.   

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt Value to be entered

Min Value?

min_value

Value?

value Max Value? max_value

 

 

ValidateTimeStamp

Description: Validate the specified timestamp is within the specified date range.

Parameters: ParametersFields that can be passed to Validate Timestamp calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt Value to be entered

Min Value?

min_value

Value?

value Max Value? max_value

 

 

ValidateUnitData

Description: Conduit implementation of VALPARTFLD. Validate Part Number Fields.

Parameters: ParametersFields that can be passed to Validate Unit Data calls. 

  Value to be entered

       Prompt       

Value to be entered

Check Field?

checkField*

Expected Value?

checkValue*

 

 

ValidateUnitLabel

Description: Conduit implementation of CHECKSN.

Parameters: ParametersFields that can be passed to Validate Unit Label calls.

Prompt 

Value to be entered

       Prompt       

Value to be entered Prompt Value to be entered

Unit Text Positions ([Start, Length])?

unitSerialPositions

Label Text Positions ([Start, Length])?

labelSerialPositions Label Serial Number? labelSerialNumber

 

 

VERCMPSTR

Description: Conduit implementation of VERCMPSTR.

Parameters: ParametersFields that can be passed to VERCMPSTR calls.

Prompt Value to be entered

Prompt

Value to be entered Prompt Value to be entered Prompt Value to be entered

Component Id Text Positions ([Start, Length])?

componentIdPositions Ref Designator To Check? refDesignatorToCheck* Label Barcode? labelTextToCheck* Defect Code? defectCodeToRecord*

 

 

ViewComponents

Description: SFDC data collector formatted components for the scanned unit.

 

ViewDefects

Description: SFDC data collector formatted unrepaired defects for the scanned unit.

 

ViewHistory

Description: SFDC data collector formatted unit history for the scanned unit.

 

 

Conduit Command Listing

Every command currently available can be found at the following URL:

https://42qconduit1.42-q.com:18006/ccr