SOP-42Q-MES0004 Data Collector Maintenance

From 42Q
Revision as of 14:37, 9 February 2024 by Afra Banu (talk | contribs)
Jump to navigation Jump to search

42Q Home > Shop Floor Control > Configuration > Data Collector Maintenance
 

 

 

 

Shop Floor Control
Configuration
Data Collector Maintenance
Version MES15.79
Revision F1
 

 

 

 


​Introduction

42Q’s powerful data collection system collects critical information from a plant’s shop floor, utilizing a shop floor data collector, an intuitive tool developed by 42Q’s experienced manufacturing team. The aggregate information is stored in a cloud database, and available to MESWeb, where quality reports are generated. The 42Q system uses manual and automated barcode scanning to collect data for a product line or plant. Thus, 42Q plays an important role in maintaining unit histories and directing product movement on the manufacturing floor. The current version of 42Q includes configuration capabilities, which provide access to all sub-module pages and their functionalities (view, add, edit, print/generate output files).


Data Collector Maintenance

Data Collector Maintenance provides definitions in the SFDC database to associate a Device Number to a Data Collection Location name.

 To access the Data Collector maintenance, navigate to Shop Floor Control>Configuration>Shop Floor Configuration>Data Collector

 

Figure 1: MES Data Collector Maintenance

SFC MESDataCollectorMaintenance.png


Note: A user only has access to the modules assigned to his/her profile.

 

List Data Collectors

Based on the actual Shop Floor Configuration, a list is displayed with all Data Collectors.

 

Figure 2: Data Collectors List

SFC DataCollectorsList.png

 

The Data Collector List displays Device #, Location, and Shop Floor ID. The user is able to deactivate a Data Collector by checking the Inactive checkbox. The user is also able to Add, Edit, Delete, and Search in Multi-Pass by selecting the Multi-Pass Location option.

In accordance with the associated Location status, the line in the Data Collector list is displayed in the colors below:

  • Status = 20 with process name:green
  • Status = 20 without process name: orange
  • Status = 28 with process name: dark green
  • Status = 28 without process name: dark orange
  • Status = 25: red
  • Status = 29: dark red
  • Status = 30: blue
  • Other Status: black

Note: The colors are based on the configuration in the Location Maintenance module.


Data Collector definitions in the SFDC database associate a Device Number to a Data Collection Location name.

Device Number refers to an actual Data Collector number. Data Collector Device Numbers range from 1-ZZZ (i.e., 28,743) using base 34. Base 34 operates such that, after 999, additional machine numbers take on the nomenclature 00A (i.e., 1000), 00B (i.e.,1001), 00C (i.e., 1002), etc. This nomenclature follows the formula [0-Z] * [0-Z] * [A-Z]. Note that the characters I and O are not used due to their close resemblance to 1 and 0, respectively.

  • CS9400 Data Collectors and PCC port addressing is limited to a range from 1-320 (each PCC has 5 communication ports with up to 32 Devices per port totaling 320 devices).
  • NetDC Device Numbers are limited to a range from 321-999.
  • Emulators can access any Device Number from 1-999.


Table.png

 


Filter Data Collectors

This functionality enables the user to perform searches. There are four available filter fields:

  • Device #
  • Shop Floor ID
  • Location
  • Status: All, Inactive and/or Active

 

Figure 3: Filter Data Collector

SFC FilterDataCollector.png

Enter desired filter criteria and select Filter to display results. Select Clear to clear filter fields.

 


Add Data Collectors

This functionality enables the user to add Data Collectors to the database.

To add Data Collectors, select Add from the Data Collector Maintenance main screen.

 

Figure 4: Add Data Collectors – Data Collector Form

SFC AddDataCollectors.png

 

The Data Collector form is displayed. Populate mandatory fields (indicated in Red) and select Save.

Fields description:

1. Device #: Refers to an actual Data Collector number. Data Collector Device Numbers range from 1-999. CS9400 Data Collectors and PCC port addressing are limited to a range from 1-320 (each PCC has 5 communication ports with up to 32 Devices per port totaling 320 devices when using two PCC's). NetDC Device Numbers are limited to a range from 321-999. Emulators can access any Device Number from 1-999.

2. Shop Floor ''''ID: Existing Shop Floor IDs within the database. Each Location record is attached to a Shop Floor ID. The Shop Floor ID is defined in Miscellaneous Configuration Maintenance.

3. Location Name: Select an Sxxx location from the drop-down list, where xxx is the Device Number. This is the location associating the Device Number to the Sxxx Location name. The Location name should exist prior to associating in the Data Collector Table.

Note: As a general rule, Device # 1 is assigned Location S001, Device # 2 is assigned to Location S002, etc. Also, Data Collector Locations S001 through S999 are only used to define Device Numbers, are not used in routes, and are never associated with a Process Name.

4. Inactive: To inactivate the Data Collector inactive, check the checkbox.

Note: The user must populate all mandatory fields (indicated in Blue) when adding new Data Collectors. If the mandatory fields are not populated, an error message is displayed.

 


Edit Data Collector

This functionality enables the user to edit the selected Data Collector.

To edit a Data Collector, select an existing Device # then select Edit. The Data Collector Form is displayed:

 

Figure 5: Data Collector List - Edit

SFC EditDataCollectorList.png

 

1. Updating a Device Number: Highlight the Device Number field and enter the desired change;

2. Shop Floor ID: Select the desired Shop Floor ID by clicking on the drop-down menu;

3. Location: If the first 4 characters of the Location Name are known, highlight the Location field and enter the desired change. If the Location Name is not known, click the drop-down menu.

Select Save to commit changes, or Cancel to exit.

 


Delete Data Collector

This functionality enables the user to delete the selected Data Collector.

To delete a Data Collector, select an existing Device #, then select Delete. A confirmation message is displayed:


Figure 6: Data Collector List - Delete

SFC DeleteDataCollector List.png

Select Yes to confirm, or No to cancel the action

 


Data Collector Search in Multi-Pass

This functionality enables the user to associate multiple Locations with a Data Collector. The purpose is to replace the Multi-Pass configuration setup from Setup Data Editor with a tablet interface and enforce a unique Location to Device configuration.

To associate multiple Locations with a Data Collector, select an existing Device #, then select Multi Pass Location.

 

Figure 7: Multi-Pass Location

SFC MultiPassLocation.png

The Associate Location(s) screen is displayed:


Figure 8: Associate Location

SFC AssociateLocation.png

 

1. Double-click on the Available/Associated Locations to move to the Associated Location(s) and vice versa.

2. To add all Locations, click on Select All.

3. Select Save to confirm, Reset to clear all fields, or Cancel to exit.

 


Print/Export Line Data Collector

This functionality prints and exports the selected Line Data Collector configuration. The report results include the Shop Floor ID, Device Number, Line, and Location Name of each Data Collector. The report prints to the default printer for the workstation.

1. To print/export Line Data Collectors, select Print/Export Line Data Collectors in the menu.


Figure 9: Print Shop Floor ID' Data Collector'

SFC PrintShopFloorIDDataCollector'.png

 

The "Choose a Shop Floor ID" window is displayed.

2. Choose the Shop Floor ID.

3. A report is generated and the user can save or print the file.

 



Print/Export Filtered Data Collectors

This functionality prints and exports the Data Collectors filtered and displayed in the list. The report results include the Shop Floor ID, Device Number, Line, and Location Name of each Data Collector. The report prints to the default printer for the workstation.

To print/export Data Collectors, select Print/Export Data Collectors in the menu.

 

Figure 10: Print/export Filtered Data Collector

SFC PrintexportFilteredDataCollector.png

 

A report is generated and the user is able to save the file or print it.

 

 

Note

Unit Status definitions Deprecated from Assembly Maintenance, Attribute Maintenance, MFG Hold, MFG Line, Location Maintenance, Data Collector Maintenance they are used/assigned by the system for internal purposes.

  • In Container (36)
  • In Transit (37)
  • Temporary Ship Status (45)
  • CRM Received (46)
  • CRM Released (47)
  • CRM RESERVED (48)
  • CRM Finished (49)
  • Killed (51)
  • Killed RBF (52)
  • Killed (56)
  • Batch Old ID (63)
  • Not DB of Record (70)

For more information please visit the  42Q-MES0160-C Unit Status Definition Work Instruction