SOP-42Q-MES0025 Serialized Item Tracker
42Q Home > Shop Floor Control > Production Control > Serialized Item Tracker
Contents
Serialized Item Tracker
The Serialized Item Tracker (SIT) is a 42Q module designed for effectively creating and importing large numbers of serialized components to be used in the manufacturing process. It eliminates much of the overhead of creating serial numbers one at a time. The serialized components can be created based on a starting serial number and algorithm or from a list of serial numbers scanned or copied from a text file.
SIT can receive, return, and make obsolete a range of serialized items. Serialized Item Ranges will be stored in a new SIT_Range table in the database. Each item in the range is exploded into the serial table as tracked components. The assignment of these items to units will be done with standard Shop Floor Control technology. There are reports and EDI extracts that will be written to support SIT. These reports and extracts are not been defined in this document as they will most likely be written outside MDS.
SIT also manages and sends e-mail alerts of the serialized items consumption by low and very low watermarks.
To access Serialized Item Tracker, navigate to Shop Floor Control > Production Control > Serialized Item Tracker
Figure 1: Serialized Item Tracker
To access Serialized Items, click on Serialized Items icon.
The Serialized Items page shows a list of locations that are based on the actual Shop Floor Control Configuration, the SIT Range List.
Users are able to perform the following actions:
- Filter and search
- Receive
- Receive (PTS)
- Edit
- Disposition
- Resend
- Additional Info
- SIT Batch Traveler
- Print/Export
- Print/Export Filtered Ranges
Figure 2: Functionalities at Serialized Items
Serialized Items List functionalities.png
Filter and Search
Users can search using the filters located at the top of the SIT Range List. There are four available searches:
- SIT Status
- Type
- Filter By
- Value
Figure 3: Filter options
Search by SIT Status or Type
To search a serial item, filter by SIT Status:
- Select one or more filters (SIT Status, Type).
- Then, select Filter to proceed or Clear to start a new search.
There are four SIT statuses that can be filtered:
- Damaged: Serial item damaged
- Obsolete: Serial item that will not be used anymore, but still exists. No longer in use or valid
- Received: Serial number created (SFDC status is the same as the location where the serial was created)
- Returned: Returns a range of serials, a specific serial, or all serials
Search by Type
There are four available types that can be filtered to display serial number ranges that are already created for all statuses (damage, obsolete, receive, return):
- COA label
- EUI-48-Intel-MAC
- Manually Entered
- Non-SN Batch
Search by Filter by
There are six available options to Filter by:
- Create User
- PO (Purchase Order of the range being received)
- PO Line (Line Number of the Purchase Order above)
- Packaging List (The shipping number of the range being received)
- Part Number
- Serial Number
To search using the "Filter by" field:
- Select one of the available options from the dropdown list.
- Enter the information into the Value field accordingly.
- Select Filter to proceed, or Clear to start a new search.
Receive
This portlet allows a user to receive (create) a range of serialized items. The user specifies the beginning and ending serial number, part number, and other miscellaneous attribute data. The range is stored in the SIT_Range table as “received” SIT status and has the same status as the location where it was created (see Location x SIT Type). Individual items are created in the database as tracked components. A serial number algorithm for the part number needs to be created and released to support generating serial numbers for the defined range.
Note: SIT works with two algorithm types:
- Shop Order Algorithm (created using the Algorithm Tool).
- Algorithm manually encoded.
The algorithm is updated with the last serial number received.
To start the receiving process:
- Select the Receive button. The SIT Range Form displays
- Select a Type from the dropdown list
- Input the required information for mandatory fields (Quantity, Starting Serial, and Ending Serial)
- Click Save to proceed, Reset to clear all fields, or Close to quit
Figure 4: Range Form - Receive
Note: After entering the mandatory fields, the Print Label pop-up for receive units is displayed. The user can fill in the mandatory fields to print the label or cancel to proceed with the receive task.
Manually Entered
When this option is selected, the following fields will be disabled:
- Quantity
- Starting Serial
- Ending Serial
A multi-line text box appears to be filled with the serials.
Input one or more serial numbers in the text box, one per line. The quantity field will be automatically updated with the serial numbers in the text box.
These serial numbers will be used instead of calculating serial numbers from an algorithm.
A new generic attribute (project:receive_sit_range_default_optional_attributes) will control which attributes will be prompted when receiving a serial number range.
- Part Number: The user selects one part number from the drop-down list, depending on the selected type.
- Batch Quantity: Calculated if the starting and ending serial fields are populated. If the Starting serial and a specific quantity are entered, the system calculates the ending serial. If the starting serial and ending serial are populated, the quantity field is disabled.
- PO: The Purchase Order of the range is being received.
- PO Line: The Line Number of the Purchase Order above.
- Packing List: The shipping number of the range being received.
- After all the fields are populated, a confirmation message is displayed.
- Click on Yes to confirm the range creation or No to cancel. The created range is displayed in the SIT list.
Non-SN Batch
Always create a batch serial number. The batch serial number quantity is determined by the received quantity.
If the part number is assigned to an algorithm, the serial number will be validated accordingly; otherwise, no validation will occur.
The default attributes are LOT Code, Date Code, and MPN. These attributes can be:
- Added: Select the Add Attribute button, enter data, and select Update to commit.
Figure 5: SIT Range Form - Add Attribute
SIT RangeForm AddAttribute.png
- Removed: Select the attribute, then select the Remove Attribute button. Finally, click on Yes to confirm.
- Edited with new attribute values: Double-click on the attribute name. Write down the new value. Default attribute values will be comma separated items, allowing for multiple default attributes to be configured.
Serial Numbers Tab
Users can visualize, export, or print serial numbers from the Serial Numbers Tab.
Figure 6: Range Form - Serial Numbers Tab
SIT RangeForm Serial Numbers Tab .png
Receive PTS
This functionality is used by plants that need traceability. This is controlled using a new set of screens and portlets in profile management, so only users with access to this screen can see or use it. Conversely, if the existing screen should not be shown in a specific project, it should not be assigned to any profile.
Receive PTS Steps:
- Check Receive (PTS) on the SIT Range List page. The Receive PTS Component pop-up displays
- Enter a PTS ID
Figure 7: Receive PTS Component
- Select Continue
- SIT calls PTS’s API
- PTS sends real-time data for the PN associated with the PTS ID (SN) according to the following attributes
Receive Fields
- Range Type is always Manually Entered. Because of this, the drop-down menu is disabled.
- Part Number: This number cannot be changed. It represents the PN associated with the PTS ID.
- Serial Numbers: Add Serial Numbers to associate with the PTS attributes.
- SN Quantity automatically populates based upon SNs added to the Serial Number field (above).
- Starting Serial: The first SN is entered into the Serial Number field. This number is automatically populated based on data added to the Serial Number text box.
- Ending Serial: The last SN is entered into the Serial Number field. This number is automatically generated based on data added to the Serial Number text box.
- Modify the PO, PO Line, and Packing List information if desired.
Note: The Part Number, Date Code, Lot Code, and MPN will contain the imported PTS information and is disabled for editing.
- If the generic attribute update_pts_data is defined as “Yes,” the Date Code, Lot Code, and MPN information will be available for editing as well.
- Select Save. This action (Save) adds the attribute information to the serial numbers specified.
Attribute Fields
- Receipt Date: Current date and timestamp
- Date Code:
- LOT Code:
- MPN: Manufacturing PN associated with the PTS SN
Figure 8: Range Form - Attribute
Edit
The Edit portlet can be used to make changes or update the PO, PO Line, and Packing List information.
- To edit, select the serial number.
- Select the Edit button. The SIT Range Form displays.
- Select the Info tab.
- Enter new values for PO, PO Line, and Packaging list.
- Select Save. The updates are saved, and the list is refreshed.
Figure 9: SIT Range Form - Edit
Resend
This functionality allows users to create an attribute for an SIT Range. This triggers another process to send an EDI file to the vendor.
Figure 10: Serialized Item Tracker List - Resend
Serialized Item Tracker List - Resend.png
- To resend a serial range, check the box of a range and select Resend. A confirmation message is displayed
- Select Yes to complete the action, (or No to cancel). A confirmation message displays and the serialized items have been resent.
Additional Information
The Info tab is divided into two sections, Receive and Attribute, where the user will be able to edit the basic information of a selected range.
Figure 11: Range Info - Info tab
In the Serial Number tab, the user will be able to do specific searches using the filter tools on the top, to search by Serial Number, Status, or Location.
Figure 12: Range Info - Serial Numbers tab
Range Info - Serial Numbers tab.png
This section allows users to Export in different formats such as CSV, HTML, PDF, XLS, and a Custom format.
Once the user selects the Custom option;
1. Select Export at the bottom of the screen
2. Select Custom option. This opens the Export Configuration window.
3. Select the file Type to which to Export the file.
The Export Configuration window will pop up and show two sections: Type' and Page Orientation.
The Type column will allow the user to choose from different document formats and the page orientation will show two options Portrait or Landscape.
4. Select Page Orientation from the drop-down.
5. Select the fields to be included in the exported file. Only the fields selected will be displayed in the exported files.
The Type column will allow the user to choose from different document formats and the page orientation will show two options Portrait or Landscape.
Figure 13: Custom Export -Type options
'SIT CustomExport TypeOptions.png'
The column in the middle will allows the user to Select the fields to be exported from one side to the other and even in order or relevance for the user.
Figure 14: Fields selection to be exported
Fields selection to be exported.png
Select Print/Export Serial Numbers to display the page that allows users to select the status desired. The Print Label option is available.
SIT Batch Traveler
This section instructs users about the SIT Batch Traveler portlet. This portlet prints all the serial numbers that make up a selected range.
Figure 15: SIT Batch Traveler
- To use the SIT batch traveler, select SIT Batch Traveler from the SIT Range List main page. This generates a PDF batch report that the user may save or print.
Print/Export or Print/Export Filtered
This section covers the print/export portlet on the main SIT Range List page. This portlet is used to Print or Export a selected range or a single serial number.
Figure 17: Serialized Items List – Print/Export
SIT Print Export Fitered Ranges.png
- SelectPrint/Export orPrint/Export Filtered Ranges in the Serialized Items Tracker list. A PDF report is generated that the user may print or save. Exporting can also be performed with multiple file formats, CSV, HTML, PDF, and XLS.
To perform this action
- Select Export at the bottom of the SIT Range List menu
- Select the format into that which you want to export the file. The file is exported and downloaded to the system in the format selected.
Similarly, the Custom function can export the information into multiple file formats.
Note: The arrow and chevron icons are used to select the fields to be included in the report and also allow the user to determine the order in which the fields will appear in the same report.
Attribute Field
- Receipt Date: Current date and timestamp
- Date Code:
- LOT Code:
- MPN: Manufacturing PN associated with the PTS SN
Figure 25: SIT Range Form
Receive Field
- Range Type is always Manually Entered. Because of this, the drop-down menu is disabled.
- Part Number: This number cannot be changed. It represents the PN associated with the PTS ID.
- Serial Numbers: Add Serial Numbers to associate with the PTS attributes.
- SN Quantity automatically populates based upon SNs added to the Serial Number field (above).
- Starting Serial: The first SN entered into the Serial Number field. This number is automatically populated based upon data added to the Serial Number text box.
- Ending Serial: The last SN entered into the Serial Number field. This number is automatically generated based upon data added to the Serial Number text box.
- Modify the PO, PO Line, and Packing List information if desired.
- NOTE: The Part Number, Date Code, Lot Code, and MPN will contain the imported PTS information and is disabled for editing.
- NOTE: If the generic attribute update_pts_data is defined as “Yes,” the Date Code, Lot Code, and MPN information will be available for editing as well.
- Select Save. This action (Save) adds the attribute information to the serial numbers specified.
Part x Sit Type
This section covers how a part number can be assigned or unassigned to an SIT type. To access the Part x Sit Type module navigate to the Serialized Item Tracker main page (Shop Floor Control > Production Control >
Serialized Item Tracker) and select Part x Sit Type.
Figure 25: Part SIT Type
The SIT Type List page displays:
Figure 26: SIT Type List
1. To edit a SIT type, check the box of a SIT type from the list and click Edit. The Part x Type list is displayed.
Figure 27: Add Part x SIT Type
2. To add an association, click on Add Part x SIT Type in the Tasks panel.
Figure 28: Add Part x SIT Type
3. Select a part number to be associated and click on Save. The selected part number will disappear from this list and will be displayed in the SIT type list, for the previously selected type. To cancel this action, select Cancel.
Editing a SIT Type:
The rules for editing SIT Types are the same for COA, MAC or Manually Entered:
1. Select Edit to edit a MAC Address or COA Label Type. The Edit page is displayed.
Figure 29: Part x Type List – Edit Part SIT Type
Figure 30: Part x SIT Type Form
NOTE: Unless the user checks the check box "Do you want to manage the LVM and VLVM?" this page will not be available for editing.
- Low Water Mark: This is a value set by the user to trigger an alert when the available SN quantity for that part number is low and needs attention. This is defined when the user intends to manage the available quantity of SN. When the LWM is reached, e-mail alerts are sent for the registered addresses.
- Very Low Watermark: This is a value set by the user to trigger an alert when the available SN quantity is very low and has become a critical situation. When the VLWM is reached, e-mail alerts are sent for the registered addresses.
2. After checking the "Do you want manage the LVM and VLVM?" box, the data can be edited.
3. The N&E Rule ID field allows users to configure a specific rule in the Notification & Escalation regarding sending e-mails. If there is a previous configured rule in the N&E, just type the rule name in this field and it will be executed. In the other hand, if there is no configured rule on N&E, the Default Rule already configured will be executed.
4. Type a user name and click on add icon for the LWM and VLWM CC E-mail. The e-mail list box is populated with the e-mail from the CC E-mail textbox. The user may also select Remove (All Items or Selected Items) for the LWM and VLWM CC E-mail. This removes the selected e-mail from the e-mail list.
Notes:
- Selected users will receive e-mails frequently unless they are removed from the list.
- ACRON job must be configured to send the emails.
Figure 31: Part x Type List - Disassociating Part Numbers
1. To delete a part x SIT type, select a part number to delete and click Delete.
NOTE: This selected part number will not be deleted from database per se; it will just be unassigned from the selected SIT type.
2. Select Yes to confirm, or No to cancel.
Location x Sit Type
This section covers how a location can be assigned or unassigned to a SIT type.
To access the Location x SIT Type module, navigate to Shop Floor Control > Production Control >
Serialized Item Tracker and select Location x SIT Type from the SIT main page
Figure 32: Location x SIT Type
1. To edit the Location, check the box of an SIT type in the list and select Edit.
Figure 33: SIT Type List
2. Edit the location and select Save to confirm the updates, or Cancel to abort.
Figure 34: SIT Type Form
Note: If the SIT Type already has received SIT Range, it will not be possible to change its location (see the image above).
Appendix A
Acronyms
Acronyms are abbreviations, such as LDAP, MES, and SFDC, written as the initial letter or letters of words, and pronounced on the basis of this abbreviated written form. By developing these acronyms, it is not necessary to write the complete name all the time in the guide.
COA
Certificate of Authenticity |
Appendix B
Glossary
This glossary is a list of terms with definitions for them.
Administrator
The System Administration has full access - all plants, all reports, all users.
Component
A component is a specific piece of data that appears on a label, for example: bar code, part numbers, graphic images, line or text. Hence, label components are broken down into several different types: text, graphic images, MES database values, or a combination of text and database values.
Framework
In software development, a framework is a defined support structure in which another software project can be organized and developed. A framework may include support programs, code libraries, a scripting language, or other software to help develop and glue together the different components of a software project.
LVM
Low watermark – this is a value set by the user to alert when the available SN for that part number is low and it needs attention. It ’ s defined when the user intends to manage the available quantity of SN. Always when the LWM is reached, e-mail alerts are sent for the registered addresses. Packing List Packing List is the shipping number of the range being received PO PO is the Purchase Order of the range being received PO Line PO Line is the Line Number of the Purchase Order above SFDC Configuration The rules used to define how SFDC collects data provides analysis, controls the processing, and maintains unit histories
Site Minder
Universal login of 42Q
Username
The username is the site minder username (or a partial string)
VLVM
Very low watermark - this is a value set by the user to alert when the available SN are very low and this is a critical situation.