How to integrate Conduit-PTS Scanning

From 42Q
Revision as of 22:39, 21 January 2022 by Marisol vargas (talk | contribs)
Jump to navigation Jump to search

 

Conduit-PTS Scanning Integration


 

Introduction

This guide shows you how to configure and activate Conduit-PTS functions.

Conduit Admin and PTS Admin are required to complete the configuration on both systems.

Required to verify (upgrade if needed) the correct version before implementing Conduit-PTS Integration.

Configuration

To activate the function, setup needs to be done in Shop Floor ID and PTS.

 

 

Shop Floor Configuration

  • Click the Data Editor under the Shop Floor Control -> Configuration -> Shop Floor Configuration menu.

 

Figure 1: Data Editor Menu

Figure 1- Data Editor Menu.png

 

  • Select one Shop Floor ID, then click the Edit button.

 

Figure 2: Select Shop Floor

  Figure 2- Select Shop Floor.png

 

  • Add this below line into the setup data editor.

OPTIONS URL_WEB_SERVICE NAME=PTS VALUE=http://pts-uat.sanmina.com:8080/pts

Figure 3: Data Editor Options Example

  Figure 3- Data Editor Options Example.png

 

#Conduit -PTS Service (For example)

OPTIONS URL_WEB_SERVICE NAME=PTS VALUE=http://pts-uat.sanmina.com:8080/pts

Note: Please replace http://pts-uat.sanmina.com:8080/pts with your Conduit-PTS service URL.

Save the changes before exit.

Server information Configuration

Make sure you have Conduit_shopFloorID & Conduit program configured from Administration-->Server information

  • Click Server information under the Administration menu
  • Add the Server information for the Conduit_ShopFloorID and Conduit program.

Figure 4: Add Server Information

 

Figure 4- Add Server Information.png  

 

Figure 5: Server Information List

 Figure 5- Server Information List.png

 

 

PTS Configuration

There are 2 places that need to set up in PTS portlets

- Add MDS Net User in PTS Administrator(System setting)

- Location Mapping in Workstation Setup(PTS)

 

Add MDS Net User

Raise P3 Service Request to the MES Support team to request add MDS Net User in Traceability Administrator ->System setting.

Please include the below details in your TT

For Example:

Plant Name: E83 Penang

MES Portal Server:143.116.xxx.xxx

NetUser ID: P99LDC1H,P99LDC168, P99TESTDC1

Support team to add the MDS Net User refer to the picture as follows.

Note: The MDS Net Users are separated by commas.

Figure 6: MDS Net User

  Figure 6- MDS Net User.png

 

Workstation Setup (PTS)

  1. Login to MES15 and from the pull-down menu(Shop Floor Control->Production Control->Traceability Setup.
  1. Select “Production Line” and “Workstation
  2. Right, Click on “Workstation” to show the right menu then click on “Location Mapping” as below screenshot.

Figure 7: Location Mapping Menu

 Figure 7- Location Mapping Menu.png

 

Location mapping page prompt up.

Click the Add button to add a mapping.

  • MDS User ID (Compulsory)

Figure 8: Location Mapping

Figure 8- Location Mapping.png

- This is referring to MDS Net User(Defined at system setting).

- All MDS NetUser IDs added in system settings will appear in the pull-down menu.

- Select the correct SFDC NetUser ID.

  • Location Name (Compulsory)

- Location name created in jMDS Location Maintenance (example S002 SMT Insp Bot or A002

SMT Insp Top or SMTT SMT Top)

- Value must be the first 4 characters from the location name (S002, A002, or SMTT)

 

  • Device ID

- Device ID that associate to location name in Data Collector Maintenance

    • - Example 1 or 401 or 508

 Click the Update button to save the configuration in PTS for the selected production line and workstation.

Once the mapping save in PTS, a list of location mapping show below

Figure 9: Location Mapping Example

  Figure 9- Location Mapping Example.png

 

Turn on the production line as usual and Conduit-PTS ready for action.

 

Conduit-Scanning Operation

By using NetDC or an emulator, users can scan serial numbers and update to both Conduit and PTS.

Conduit Commands

  • ScanPtsBoard
  • CheckPtsComponent
  • ptssplitpanel
  • UpdatePtsComponent
  • Validateboard
  • LoadPtsMaterial

 

 

 

Scan Scenario

Conduit-PTS call

Macro: LoadPtsMaterialMacro

Load the material to the slot

Figure 10: Load Material to Slot

  Figure 10- Load Material to Slot.png

 

 

Figure 11: Load the Material Successfully

  Figure 11- Load the Material Successfully.png

 

Tried to load the same material to the slot.

Figure 12:  Load the Duplicated Material Failed

  Figure 12- Load the Duplicated Material Failed.png

Conduit Macro: CheckPtsComponentMacro

Verified the material has been loaded

 

Figure 13: Check Material loaded

Figure 13- Check Material loaded 1.png

Figure 13- Check Material loaded.png

 

 

Note:

Before scanning, we need to make sure the location mapping to the workstation, otherwise, we will have the following error.

Figure 14: Location not Mapping

  Figure 14- Location not Mapping.png

 

 

Macro: ScanPtsBoardMacro

After loading the material we are able to scan the serial number

Scanned serial: PAKS02567, PAKS02568, PAKS02569

Figure 15: Scan PTS Board

  Figure 15- Scan PTS Board.png

 

 

The material runs out:

Figure 16: Check Material Runout

  Figure 16- Check Material Runout.png

 

 

Loaded the material After a material runout

Figure 17: Load More Material when Runout

  Figure 17- Load More Material when Runout.png

 Figure 17- Load More Material when Runout 1.png

 

Macro: UpdatePtsComponentMacro

Material splicing to the slot

Figure 18: Material Splicing to Slot

 Figure 18- Material Splicing to Slot.png  Figure 18- Material Splicing to Slot1.png  Figure 18- Material Splicing to Slot2.png

 

 

 

Conduit macro: validate board

Figure 19: Validate Board

  Figure 19- Validate Board.png

 

 

Reporting

PTS scan board in production

Figure 20: PTS scan board in production

  Figure 20- PTS scan board in production.png    

Board history report

Figure 21: Board History Report

  Figure 21- Board History Report.png  

 

Material onboard report:

Figure 22: Material on Board Report

  Figure 22- Material on Board Report.png

 

 

Note: For further assistance on Conduit-PTS Integration, please do not hesitate to contact the MES Support team.