SOP-42Q-MES0070 Statistical Process Control TV

From 42Q
Jump to navigation Jump to search

42Q Home > Quality > Statistical Process Control TV

 

 

 

 

Quality
Statistical Process Control TV
Version MES15 Portal 1.0
Work Instruction
Revision A1

 

This Work Instruction is 42Q's corporate standard.
This document is under revision control. The latest revision is located on Intranet.
Once printed it is an uncontrolled copy. All alterations to this work instruction require approval.
Contact the IT Global Education and Training Department to submit suggested alterations and or updates.

This edition applies to MES15 Portal 1.0 Application and all subsequent releases and modifications until otherwise indicated in new revisions.

 

SPC TV Portlet

Like the SPC portlet, SPC TV portlet is another component of the SPC system. SPC TV enables users to view SPC control charts in any combination in one page through some simple configuration so that users can learn the latest status of any line or location in real time.

Add SPC TV Portlet

After the SPC portlet is installed, click the SPC TV sub-menu on the left side, move the cursor over the Add selection menu on the top left corner, and choose More from the drop down menu.

RTENOTITLE

 

From the MES menu tree, select SPC, then select TV from the SPC menu tree. Select Add. An SPC TV portlet will be added onto the page.

RTENOTITLE

 

Note: By default, there is only one SPC TV page on the left navigation menu, and only one SPC TV portlet added in the page. Users do not have the permissions to add an SPC TV page or SPC TV portlet. If  a user wants to make such an addition, they must submit a Work Request and have MES Support team to make the addition.


Set Page Layout

Move the cursor over the Manage selection menu, and select Page Layout sub-menu from the drop down list.

RTENOTITLE

In the float panel, 11 layout templates are available, users can select one, and click the Save button to apply the layout to the users' page. By default, the 2 Columns (30/70) layout template is selected.

RTENOTITLE

 

Configure Preferences

Users must configure preferences before the SPC TV portlet shows the SPC control charts properly. Click the RTENOTITLE icon from the SPC TV portlet controls bar, and select Preferences from the drop down menu.

RTENOTITLE

Select an available server, monitor, and chart from each drop-down selection box. Complete the remaining parameters and click Save.

RTENOTITLE

Some of the fields are explained as follows:

Monitor Group: Currently the SPC monitors are grouped into two categories according to the data source: MES and SPI. Users can select a monitor group name here.

Monitor: The monitor that was created under the selected monitor group in the SPC portlet.

Note: By default, users can only select the monitors that had data in the past few hours.The monitors that had no data in the past several hours will be hidden. Users can define the hours at the SPC System Paramper page Hide on TV and dashboard if monitor with no data since (hours) option.

Users can also input the hidden monitors manually, at that support fuzzy search, when users input the first 3 letters, the monitor will list out automatically.

Chart: The control charts that were configured in the selected monitor. Please note that the Pareto chart and Yield chart will not be displayed in this field even if they were configured in the SPC monitor.

Number of point: The maximum points that will show on the selected chart.

Refresh(min): Every xx minutes, SPC TV will refresh for new data.

Display counter: Preference as to whether the countdown timer on the SPC TV portlet (on top right corner) is displayed.

Size: The size of SPC TV portlet, users can either select a fixed size or define their own size.


Tip:

For details about how to get the best display effect under different screen resolutions, users can refer to SPC TV Configuration Guide

 

Exceptional Icons

  • If there is no setting for the SPC TV portlet, it will display a gear icon.

RTENOTITLE

 

 

  • If there is no data, the SPC TV portlet will display an exclamation mark icon.

RTENOTITLE

 

 

  • If the monitor is deleted, SPC TV porlet displays cross delete icon.

delete icon

 

  •   If the monitor is disabled, SPC TV portlet displays  minus icon.

minus icon

  • If there is an exception error, SPC TV portlet displays a question mark icon.

  RTENOTITLE

Roles & Permissions

Roles→
Permissions↓
SPC_Corp_Support SPC_Plant_Admin SPC_Plant_Manager SPC_Plant_User *SPC_Plant_Operator
SPC          
Add/Edit/Delete Monitor
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Start/Stop Monitor
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Disable/Enable Monitor
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Add/Edit/Delete Monitor Group
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Input/Edit Data
Tick-icon.png
Tick-icon.png
Tick-icon.png
 
Tick-icon.png
Add/Edit/Delete Email
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Delete Log
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Edit OCAP
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Disable/Enable Data
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Add/Edit/Delete Location Family
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Disable/Enable Location Family
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
Edit System Configuration/Global System Configuration
Tick-icon.png
Tick-icon.png
     
Unlock
Tick-icon.png
Tick-icon.png
Tick-icon.png
   
View
Tick-icon.png
Tick-icon.png
Tick-icon.png
Tick-icon.png
Tick-icon.png
Add to Page
Tick-icon.png
       
Configuration
Tick-icon.png
       
SPC Server Information          
Add/Edit/Delete Server
Tick-icon.png
Tick-icon.png
     
View
Tick-icon.png
Tick-icon.png
Tick-icon.png
Tick-icon.png
Tick-icon.png
Add to Page
Tick-icon.png
       
Configuration
Tick-icon.png
       

 

Notification:

  • ‘SPC_Plant_Operator’ is for plant E68 only.

Glossary

1. MFG hold: MFG hold is short for manufacturing hold. SPC sends an MFG hold to MES or SFDC to stop manufacturing line. It is another action SPC can take when point is out of control limit.

2. MES: Short for Manufacturing Execution System.

3. SFDC: The SFDC (Shop Floor Data Collection) System is the main software/hardware system used by 42Q for production control and the collection of manufacturing data.

4. Exception: SPC considers some out-of-control a valid a group, meaning that the group poses as exception based on the rules users selected when configuring monitor parameters.

5. Valid group: It means the data that is in the normal scope. On SPC control charts, a valid group of data points are plotted between the UCL and LCL.

6. DPMO: Short for Defects Per Million of Opportunities.

7. OCAP: Short for Out of Control Action Plan.

8. Ext JS: Ext JS JavaScript Framework. Ext JS is a pure JavaScript application framework for building interactive web applications using techniques such as Ajax, DHTML and DOM scripting.