SOP-5-I-42Q-MES0106-C 42Q APK

From 42Q
Revision as of 07:41, 13 October 2020 by Helena wang (talk | contribs)
Jump to navigation Jump to search

42Q Home > Tools > Cirrus APK
RTENOTITLE

 

 

 

Tools
42Q APK
Version MES15 Portal 1.0
Work Instruction

 

This Work Instruction is 42Q's corporate standard.
This document is under revision control. The latest revision is located on Intranet.
Once printed it is an uncontrolled copy. All alterations to this work instruction require approval.
Contact the IT Global Education and Training Department to submit suggested alterations and or updates.

This edition applies to MES 15 Portal 1.0 and all subsequent releases and modifications until otherwise indicated in new revisions.
Legacy documentation for Cirrus APK can be found here

Introduction

42Q provides three solutions to manage tablet use on the factory floor:

  • AppGarden (Installed on every tablet): Allows installation and updates on Android mobile devices
  • APK (Android Package Maintenance):  (MES Portal): Serves as a repository for Android tablet applications
  • Android Device Maintenance (MES Portal): Manages the tablets

Used together, the tools serve two important purposes:

  1. Control permissions for tablet users.
  2. Stream updates and configure installation to tablet applications.

NOTE: Prior to release, the tablets must be configured by an administrator. For more information on how to configure the tablet’s Host, Station ID, or Unit ID, please refer to the Administrator Pre-Configuration section of this document.

 


Hardware and Software Requirements

Supported Android OS    Android OS version : 
Android 4.2.2 above

Suggest Android OS version is OS 7 above

Bundled package:
AppGarden
42Q APK


Administrator Pre-Configuration

Before a user may begin using the application, the Administrator must set up the device by entering the administrator password and setting the Host and Station ID. Once completed, the device is ready for data collection.

1.     On the initial landing page, select the Configure Station ID button to display the Administrator password prompt.

Figure 1: Initial Landing Screen

RTENOTITLE
 

Figure 2: Administrator Password Prompt

RTENOTITLE
 

2.     Enter the Administrator password and select OK.

3.     To proceed with setup, enter a Host in the entry field and select the Reload Station ID button.

Figure 3: Host and Station ID Selection

RTENOTITLE
 

Once a successful connection has been made, the Station ID may be selected and the appropriate Unit IDs will be populated.

4.Select the language from theChoose Language dropdown menu. Support English and Chinese from Version V2.23.


NOTE: The 42Q APK uses a built-in keyboard for ease of use, however for some Android versions, it may be helpful to disable the default keyboard to avoid conflict.

Access

Once the Administrator has launched the 42Q PSI application and entered the Host and Station ID, the user can select a default view mode and Unit ID.

The following View Modes are available to the user:

  • Data Collector
  • PCB Work Order
  • Work Instruction
  • Scan Activity
  • Unit History

 

NOTE: The View Mode selection dictates the default view upon logging in. All other view modes are available (unless PCB Work Order is selected) in tabs from the Data Collector screen.

 

1. To log into the mobile Data Collector, select a View Mode from the drop down list provided.

 

Figure 4: View Mode Selection

VewModeDropdown.png

 

2. Select a Unit ID from the list provided.(The Unit ID list is created from the Device Maintenance portlet in 42Q.)

 

Figure 5: Unit ID Selection

UnitID.png

 

3. Select the checkmark to log in to the mobile Data Collector.

 

Figure 6: Log In

LogIn.png

 

4. The initial log in screen prompts the user for an Employee Number.

 

Figure 7: Initial Log In Screen

04APK.png

 

5. Once an Employee Number is entered/scanned, the default view mode will display.

 

Data Collector Mode

After selecting the Data Collector view mode and entering an Employee Number, the device is ready to begin data collection.

 

Figure 8: Data Collector Default View Mode

05APK.png

 

If it is necessary to change view modes, they can be accessed by tapping the top of the screen, as shown in Figure 9.

 

Figure 9: Additional Tabs

06APK.png

 

Work Instruction Mode

If Work Instruction was selected as the default view mode, the screen will either display the default deviation, or the last uploaded document for the Part Number at that Process.

 

Figure 10: Work Instruction

Doc Display.png

The following navigational controls are provided on the left of the screen:

Buttons.png

 

 

If multiple documents are uploaded for the serial ’

s Part Number and Process, they can be accessed by closing the current document, then selecting the document icon in the input field at the bottom of the screen. All documents mapped to the scanned part number and process will display in a list for selection.

 

Figure 11: Multiple Document View

08APK.png

 

Activity Log

If Scan Activity was selected as the default view mode, the following screen will display after entering an Employee Number:

 

Figure 12: Scan Activity View

09APK.png

 

Unit History

If Unit History was selected as the default view mode, the following screen will display after entering an Employee Number:

 

Figure 13: Default Unit History View

10APK.png

 

NOTE: Currently, local and custom commands can be executed in the mobile data collector. Any action executed will display in the Unit History report tab.

 

Figure 14: Command Execution in the Unit History Tab

11APKv2.png

 

PCB Mode

The PCB Work Order mode is a customer specific tool that allows for non-serialized batch processing by interfacing with INPLAN-ERP. For more information, please refer to the MES for PCB documentation.

 

 


Document Revision History

Date Author Title Version Change Reference
07/17/17 Lucas Hopkins Technical Writer v 2.0 This is the first version of Revision A2