SOP-42Q-MES0047 PTS Moisture Sensitive Device
42Q Home > Production > PTS Moisture Sensitive Device
This edition applies to MES 15 Portal1.0 and all subsequent releases and modifications until otherwise indicated in new revisions.
Contents
- 1 Production
- 2 MSD (Moisture Sensitive Device)
- 2.1 Check MSD Status
- 2.2 Unfinished MSD Handling
- 2.3 Uncompleted MSD Report
- 2.4 Customized Bake Time
- 2.5 Manual Input
- 2.6 Expired Board Report
- 2.7 Board Handling
- 2.8 Unexpired Board Report
- 2.9 Uncompleted MSD Report
- 2.10 MSD Process for Loading Material
- 2.11 MSD Process for Unloading Material
- 2.12 MSD Process for Scanning Board
- 3 Document Revision History
Production
The Parts Traceability System (PTS) is one of the applications within the MES suite of tools. It was developed to meet the demands of customers to provide component level traceability as well as to provide quality controls. This system plays a very important role in automating the production lines and raising productivity as well as enforcing rigorous product quality control. It has been implemented to many plants across the globe. This application and the features it provides continue to evolve, as the changing technologies used for the SMT process equipment tools become more detailed and rich in functionality. There is and will continue to be a requirement to support the older technology tools. We strive to provide the flexibility to support each of the line types and provide the different and many levels of traceability required for the business.
MSD (Moisture Sensitive Device)
General Notes
This Work Instruction is a basic general training guide and is not meant to teach the process flow for individual plant or department functionality. Individual Sanmina sites may have minor or specific process changes that will be documented at the site level.
Online help is available in PTS.
Pre-Requisites
- PTS login account
- Access to intranet
- Process flow of MSD Control
- Finished the PTS MSD Control Work Instruction
Overview
The control of moisture-sensitive devices (MSDs) prior to SMT reflow is a critical assembly issue that has a direct impact on final product reliability and customer satisfaction as well as manufacturing costs. The guidelines for storage and handling of MSDs are clearly defined in the joint IPC/JEDEC standard J-STD-033.
MSD General Flow Chart
Below is a MSD general flow chart.
Figure 1: MSD General Flow Chart
Below is flow chart about scanning board process.
Figure 2: MSD Scanning Board Process
Check MSD Status
1. To access the Check MSD Status page, navigate to Production > MSD (Moisture Sensitive Device) > Check MSD Status.
2. Enter the material barcode.
3. If the material is valid MSD material, the detailed information will display.
Figure 3: Check MSD Status
- If the operator enters a non-existent material barcode, the system will display the following message: "Material barcode not found".
- If the operator enters a non-MSD material barcode, the system will display the following message: "This material isn’t MSD material".
- The operator can enter any MSD material which is in any status and related items. For example MSD level, floor life, current status and process time etc. can be all displayed.
- The pie chart located on the right displays the MSD expose time and the MSD remain time. It is a very easy and clear way for users to understand current material MSD status.
Unfinished MSD Handling
This module is used to handle pending/unfinished MSD material, which is in pending status or already expired.
Key in material barcode, system will check for MSD spend time.
1. To access the Unfinished MSD Handling page, navigate to Production > MSD (Moisture Sensitive Device) > Unfinished MSD Handling.
2. Enter a MSD material barcode into the Material Barcode text box.
3. After entering the Material Barcode, click anywhere on the web page.
Figure 4: Pending MSD Handling
4. MSD material information will be shown in the MSD Information box.
5. Select handling method from Process Status. Currently, provided the following four methods:
- Dry bags: to handle the MSD material which still not expired or in pending status
- Dry cabinet at 5%RH or Dry cabinet at 10%RH: it can dry unexpired or pending MSD material. It can also be used for large MSD material.
- Bake: used to bake the expired MSD material.
- Select an action and select Send to handle this MSD material.
NOTE: For any expired material, the user must select Bake Action.
Figure 5: Pending MSD Handling- Bake
If the user selects Bake material, the following options will be available:
- Bake Duration (hours): how long the MSD Material will be baked. (It can be changed.)
- Bake Time (h: m): system default current time. (It cannot change.)
- Customize Bake Information: only for special plants to customize the temperature and humidity.
NOTE: For details about how to customize bake information, please review Customize Bake Time function.
- Standard Bake Information: if no special temperature and humidity, select the standard one from this box as stated.
- Select Send to Bake the MSD material.
NOTES:
- If the operator enters a non-existent material barcode, the system will display the following warning message: "Material barcode not found".
- If the operator enters a non-MSD material barcode the system will display the following warning message: "This material isn’t MSD material".
- If the operator enters a MSD material and chooses process status Dry Bags then selects Send,the current MSD material will be put into dry bags for PTS.
- If the operator enters a MSD material and chooses process status Dry cabinet 5%RH or Dry cabinet 10%RH and selects Send, the current MSD material will be put into dry cabinet for PTS.
- If a MSD material is in loading status for scanning, then the MSD material cannot be processed by this function.
- If a MSD material is already terminated in MSD control, then it cannot be processed by this function.
Uncompleted MSD Report
1. To access the Uncompleted MSD Report page, navigate to Production > MSD (Moisture Sensitive Device > Uncompleted MSD Report.
In this report, the system provides four statuses for MSD: Material Baking, Dry Bag, Cabinet and Pending. The user can review the MSD material’s basic information and search MSD material by MSD Material Barcode, Status', or42Q' P/N.
Figure 6: Uncompleted MSD Report
2. Select Material barcode field.
3. One sub-page will be entered.
NOTE: If the MSD material has history records, the records will show when selecting Cabinet or Bake.
Figure 7: Pending MSD Report- Detailed
Customized Bake Time
This module allows the user to customize the bake time for special plant requirements so that the baking time is specific for each plant.
1. To access the Customized Bake Time page, navigate to Production > MSD (Moisture Sensitive Device) > Customized Bake Time.
Figure 8: Customized Bake Time
2. Select Add to add new baking time.
Figure 9: Add Customized Bake Time
3. Enter Temperature. (Plant Temperature)
4. Enter Humidity. (Plant Humidity)
5. Enter Bake Temperature.
6. Select Send.
7. Select Cancel.
Change Baking Time
1. Double click on an existing Bake Temperature / Temperature / Humidity from the Customized Bake Time
main page.
2. Modify the appropriate information.
3. Select Change to save the new information.
4. Select Delete to delete the current record.
5. Select Cancel to cancel the operation.
Delete Baking Time
1. Check the box to the left of the Bake Temperature/ Temperature/ Humidity to be deleted.
2. Select Delete.
Figure 10: Delete Customized Bake Time
3. Select OK to delete the bake time.
Manual Input
This module allows the user to manually open, check, handle or terminate MSD materials.
1. To access the Manual Input page, navigate to Production > MSD (Moisture Sensitive Device > Manual Input.
Figure 11: Manual Input
Here provide four functions to manually open, check, handle, or complete MSD material.
Open MSD Package
1. Enter the Material Barcode
2. Select Open MSD Package.
NOTE: This function will not open running or pending MSD material.
3. Select Send. The system will begin to calculate the floor life of the MSD material automatically and the successful message will display.
Figure 12: Manual Input- Open MSD Package
Check MSD Status
1. Enter the Material Barcode.
NOTE: Entry should be opened MSD material.
2. Select Check MSD Status.
3. Select Send.
Figure 13: Manual Input- Check MSD Status
Pending MSD Handling
1. Enter the MSD Material Barcode.
2. Select Pending MSD Handling.
3. Select the process from Process Status.
4. Select Send.
Figure 14: Manual Input- Pending MSD Handling
Terminate MSD Control (By Reel)
If the entire package of MSD components completes and passes the final reflow, then the repair technician can scan the material barcode and select the Terminate MSD Control (By Reel) option.
1. Enter the MSD Material Barcode.
2. Select Terminate MSD Control (By Reel).
3. Select Send. The system will stop calculating the floor life of this MSD material.
Figure 15: Manual Input- Terminate MSD Control
NOTES:
- When the operator enters a MSD material barcode and chooses Open MSD Package and selects Send,the system will start to calculate current material MSD exposed time.
- When the operator enters a MSD material barcode and chooses Check MSD Status and selects Send, the system will link to the function Check MSD Status.
- When the operator enters a MSD material barcode and chooses Pending MSD Handling and selects Send, the system will link to the function Pending MSD Handling.
- When the operator enters a MSD material barcode and chooses the Terminate MSD Control and selects Send, the system will stop current material and any MSD process and at the same time change its status to MSD terminated.
Expired Board Report
This report displays all the selected production line’s detailed information and expired board’s information.
1. To access the Expired Board Report page, navigate to Production > MSD (Moisture Sensitive Device) > Expired Board Report.
Figure 16: Expired Board Report
Board Handling
Once the desired board has been handled, it can be reused again. At this point, the MSD shield will be refreshed and the baking record will be recorded.
1. To access the Board Handling page, navigate to Production > MSD (Moisture Sensitive Device) > Board Handling.
Figure 17: Board Handling
2. Enter the Board Barcode.
3. Click anywhere on the page and the Bake Oven box will become available.
4. Select temperature and humidity.
5. Enter Bake Duration (in hours).
6. Select Bake Time and Bake Date.
7. Select Send.
8. The operation will be recorded.
Unexpired Board Report
This report will show all the detailed information and production line’s WIP board information.
1. To access the Unexpired Board Report page, navigate to Production > MSD ( Moisture Sensitive Device) > Unexpired Board Report.
Figure 18: WIP Board Report
Uncompleted MSD Report
This report will show the selected production line’s detailed information and the "In-Use" MSD information.
Figure 19: In-Use MSD Report
MSD Process for Loading Material
- If a new MSD material is loaded for the first time, then it will be treated as if the operator were opening the package immediately. The MSD level (user defined when printing label) and humidity (user defined in system setting) and temperature (user defined in system setting) must match at least one MSD floor life policy data record.
- If a MSD material is in baking status and the bake time is not completed, then the current material will not be allowed to load.
- If a MSD material is expired, then the material will not be allowed to load.
- If a MSD material is in baking status then its MSD start time will be modified to the current time.
- If a MSD material is in dry bag or dry cabinet, then its exposed time should not include time of dry bag or time of dry cabinet.
MSD Process for Unloading Material
- If a MSD material is unloaded, then its MSD status will be changed from open package to pending.
- If a MSD material is unloaded and its remaining quantity is zero, then its MSD status will be changed to a special status which stands for "quantity of current material is zero."
MSD Process for Scanning Board
- If one of all MSD materials for current workstation is MSD expired, then the current workstation scanning board is not allowed and corresponding error message is displayed.
- If current board is already MSD expired, then the current scanning board is not allowed and corresponding error message is displayed.
Document Revision History
Date | Author | Title | Version | Change Reference |
08/01/13 | Helena Wang | Technical Writer | 1.0 | Initial SO Work Instruction |
02/17/14 | Ashley Martin | Technical Writer | 1.0 | Review and Format |
02/28/14 | Elaine Fonaro | Technical Writer | 1.0 | Format for WIKI |
12/12/16 | M. Jordan | Technical Writer | 1.0 | Format for 42Q |