SOP-5-I-MES0040-C RA1 Batch Process

Batch Process described here is a module in Cirrus that provides a web page interface for performing Batch Processing operations. The functions that are available in the portlet are Create Batch, Split Batch, Merge Batch, Remove Unit, Add Component, and Add Sub-Attribute.


SOP-5-I-MES0041-C RA1 100 Traceability

This 100% Traceability module described here allows the operator to utilize hand placement and Fujitrax Rework.


SOP-5-I-MES0042-C RA1 Data Collector

Data Collector module described here is a tool implemented on the shop floor that displays uploaded work instruction documents, deviations, CAD views of devices, and recorded and repaired defect codes, all based on unit serial scanning.


SOP-5-I-MES0043-C RA1 Production Documentation

The Production Documentation module described here is where the user can search and list work instruction documents without having to perform SFDC scanning.


SOP-5-I-MES0044-C RA1 PTS Glossary

There are many technical terms and acronyms that are applied throughout the PTS flow. This Glossary serves as a tool to assist the user with the PTS work instructions for the Cirrus Portal


SOP-5-I-MES0045-C RA1 Labor Tracking

The Labor Tracking module described here contains functions that allow users to register labor records, and to add and edit labor hours.


SOP-5-I-MES0046-C RA1 Label Engine

The Label Engine module described here is responsible for label creation. Using LE Labels, the operator can create labels using the MES system without the IT development team.


SOP-5-I-MES0047-C RA1 PTS Moisture Sensitive Device

The control of MSD’s (Moisture-Sensitive Device) prior to SMT (Surface Mount Tech) reflow is a critical assembly issue that has a direct impact on final product reliability and customer satisfaction, as well as manufacturing costs. This function monitors all MSD components’ floor life statuses. The production operator is alerted if the MSD component’s floor life is expired.


SOP-5-I-MES0048-C RA1 PTS Production Part Traceability

The Parts Traceability System (PTS) is one of the applications within the MES suite of tools. It was developed to meet the demands of customers to provide component level traceability as well as required quality controls. The production traceability plays a very important role in automating the production lines and raising productivity as well as enforcing rigorous product quality control. This module contains information on load/prepare materials, special workstation, load SMT tools, scan board, and rework handling.


SOP-5-I-MES0049-C RA1 PTS SMT Part Traceability

The SMT Part Traceability module described here contains the EZpicklist, Show BOM, Feeder Registry, and Jig Registry. EZPicklist is a web-based interface to collect and manipulate SMT placement programs into PTS for material verification against the BOM (Bill of Materials). Show BOM allows user to view BOM, disable BOM or enable BOM. Feeder Registry is a feeding tool for material reels. It becomes a bridge between the material component and SMT machine. Each component must be loaded to one SMT machine at one particular station. This is only one of the essential elements for traceability. In order to distinguish each feeder, a unique printed barcode on each feeder is required and maintained in PTSWEB.


SOP-5-I-MES0050-C RA1 PTS Tool Set Part Traceability

The PTS Tool Set Part Traceability module is responsible for tool set creation. Using Tool Set Part Traceability, the operator can create or repair the label pallet and request inspection.


SOP-5-I-MDS0076-C CMMS Work Order & Preventive Maintenance

The main purpose of the CMMS - Work Order portlet is to create a work order containing as much data as necessary to perform tasks. CMMS Preventive Maintenance allows users to create regularly scheduled maintenance to help prevent negative events and to ensure the equipment on the shop floor is in satisfactory operating condition. Refer to the User Guide for further information.