42Q-MES0112-C Configuration Publish

From 42Q
Revision as of 21:10, 12 June 2024 by Karen Barajas (talk | contribs)
Jump to navigation Jump to search

42Q Home > Shop Floor Control > Configuration > Configuration Publish
 

 


 

 

Shop Floor Configuration
Configuration
Configuration Publish
Version MES 15.75
Revision C1
 

 

 

Introduction

The Configuration Publish Portlet is used to publish configuration changes for use with Conduit and has the ability to automatically or manually publish these configurations within the portlet.

To access the Configuration Publish page, navigate to Shop Floor Control > Configuration > Configuration Publish.
 

Figure 1: Configuration Publish Access

CP ConfigurationPublishaccess.png

This portlet displays a top panel with two grids underneath: To Publish and Published. The top panel displays the number of pending configurations to publish.

Note: If there are pending configurations that need to be manually published, the Publish All button will display.  Pending configurations appear in the To Publish list, while changes already published are viewable in the Published list.  

 

Auto Publish

Configuration Publish will automatically publish configuration changes when the auto-configuration generic attribute is active.

To use auto-publish, 

  1. Navigate to Administration > Generic Attribute Maintenance
  2. Select the Add button.
  3. Add the generic attribute “auto_configuration_publish” and set it to “yes”. For more information on setting generic attributes, see Generic Attribute Maintenance.


Note: If the attribute is already added, the systems won’t allow the user that option.

 

Figure 2: Auto Configuration Publish

 

 

Once this is done, changes saved in SFDC Configuration will be automatically published.

 

 

 

 

 

Manually Publish

When changes need to be published andAuto Publish is not configured, users can manually publish the configurations.

Pending changes to publish will display in the To Publish grid. 


Figure 3: To Publish List

 

 

 

  1. Select the Publish All button to publish all pending configurations. 

 

 Once the publishing process has been completed, the published configurations will be removed from the To Publish list and appear in the Published list. 

 

Figure 4: Published List

 

 

 

To view detail about the pending or published configurations,  

  1. Double click the desired configuration from the corresponding list to open the Details pop-up window.

The Details pop-up window displays the following fields  

  • Origin - The area where the configuration was made. 
  • Event - Tells whether the change was new (INSERT), an UPDATE, or DELETE.
  • Qty - Quantity


Figure 5: Details pop-up window

 

 

 

 

Export 

Both, To Publish and Published can be exported to several different file types.

To export a grid list, select the Export button for the desired grid, then select the desired file type.

Supported file types:  

  • CSV
  • HTML
  • PDF
  • XLS
  • Custom

 

Note: The Custom option is used to export only selected fields.

 

Figure 6: Export

 

 

Due to reducing the retrieving data time to export, the application provides an option to export data for the last 3 months instead of all data since the first day.

Select the option  CP logo1.png  and select Export to get the report with the last 3 months.