SOP-42Q-MES0150 QCP Configuration Portlet

From 42Q
Jump to navigation Jump to search

42Q Home > Shop Floor Control > Configuration > QCP Configuration Portlet

RTENOTITLE


 

Shop Floor Control

QCP Configuration

MES15 Version1.0 

Work Instruction


 

This Work Instruction is 42Q’s corporate standard.

This document is under revision control. The latest revision is located at Intranet.

Once printed it is an uncontrolled copy. All alterations to this work instruction require approval.

Contact the IT Global Education and Training Department to submit suggested alterations and or updates

 

Introduction 

The QCP Configuration Portlet provides users with administrators profiles, the ability to create checklists with pre-configured questions for specific stations.

To access QCP Configuration Portlet, from the 42-Q portal, navigate to Shop Floor Control >Configuration Control>QCP Configuration.

 

Figure 1: QCP Configuration

RTENOTITLE

The next sections provide details on how the QCP Configuration works:

 

QCP Configuration

At the top of the QCP Configuration landing page, the header displays the following menu: SFDC ID List, QCP List, and New QCP.

 

SFDC ID List 

In the SFDC ID List section, administrators using QCP for the first time must select an SFDC ID to see or to enter the configuration and create a New QCP.

Note: This the configuration will be saved and it won’t be necessary to do it on the next login. 

Figure 2: Instance: SFDC ID

QCP 2InstanceSFDCID.png

 

The QCP Configuration page is displayed:

 

Figure 3: QCP Menu

QCP 3QCPMenu.png

 


QCP List


The QCP List displays the state and configurations of the already created checklists; by using the Name field, the user is able to search for a specific checklist; this option also allows the user to modify the checklist, Edit, Copy and Delete once the user selects the checkbox. RTENOTITLE

Figure 4: QCP List

4List.png

The + More button allows the user to choose from a dropdown list for more specific search options such as Restore Defaults, Location, Part Number, Process, or the Approved checklists.

 

Figure 5: QCP +More Options

QCP 5MoreOptions.png

 


New QCP

To create a New QCP checklist for a specific location, select the New QCP option. Enter the QCP checklist Name followed by the Context and Frequency described below:

 

Figure 6: Create New QCP

QCP 6CreateNewQCP.png

 

Context

Once the user selects Context, a menu displays showing the available options:  Station or  Process.

Figure 7: Station and Process

QCP 7Station Process.png

 

Station

 

Inside the Station, the administrator can select where the QCP checklist is available either by Station or Process.

Once Station is selected, the following options are available: Part Number and Part Number Mask (not mandatory), these options allow the user to customize and optimize their checklist;  the option By User, is shown at the end of the list, and it can be enabled only if the administrator wants the checklist to be displayed and answered by every user that uses that Station or Process; the QCP checklist will be displayed in the specific Station or Process when the user logs in the selected  Station or Process.

Note: If the administrator selects the option By User, the QCP must be filled every time the checklist expires based on the frequency configured.
 

Figure 8: Context, Station

QCP 8Context, Station.png

 

 Process

If Process is selected instead of Station the option Location in Process will be enabled. This option allows the user to display the QCP (checklist) in ALL the Locations that belong to a specific Process.

Figure 9: Process: Location in Process

QCP 9ProcessLocationandProcess.png

 

Frequency

Frequency indicates the time and how often the administrator wants the checklist to be visible for the user, the Frequency can be adjusted according to the administrador needs:  Every Minute, Every Time, and By Shift. 

Figure 10: Frequency

QCP 10Frequency.png

If the Frequency is set to Every Minute, the checklist will display every minute after the checklist is answered,  if the user selects the option Every Time it is necessary to enter the exact hour, e.g. 7:00, 8:00, 9:00  and will be able to set more than one hour apart from the minutes.

Note: If both values Every Minute and Every Time are configured, the checklist will be displayed when the next one expires (the closest).

If the user chooses the option By Shift, the established time will appear at the beginning of every shift that has been previously configured in the SFDC Configuration module. The Early Submit Allowance can only be enabled if the option By Shift is selected and this allows the user to set minutes previous to the established time so the user can have a time advantage. 

 

Figure 11: Every Minute, Every Time, By Shift 

QCP 11Every Minute, Every Time, By Shift .png

Note: The three options Every Minute, Every Time, and By Shift can be all selected at the same time or just one at the time.

 


Description

From the Description field the user can generate and customize the QCP questions; the Type option allows to choose from three different types of data to set the questionnaire answers: Multiple Choices, Text or Number, the QCP checklist can also be set to be required, or to keep showing or not by choosing the option On.

 

Figure 12: Description and Type

QCP 12DescriptionandType.png

 


 Data Type

Multiple Choices allows the user to customize the questions by adding the necessary values to their questionnaire e.g Option 1 Option 2 Option 3.

 

Figure 13: Data Type:  Multiple Choice

QCP 13DataTypeMultipleChoice.png

The user answering is able to see these options as checkboxes on the questionnaire, only if the option Allow Multiple is selected but if it’s not selected the options will show as radio buttons, which only allow the user to select one option at a time.

The Text option allows the administrator to leave the question answers open for the user to complete by writing.

  • Note: The mask feature will be available in the next QCP phase.*

 

Figure 14: Data Type: Text

QCP 14DataTypeText.png

Note: The options Edit and Delete are available for each type, located in the bottom right corner.

 

The Number option includes several validations such as Greater than, Less than, and Allow Decimals allowing the administrator to customize the checklist. 

  • Note: These functionalities will be available in the next QCP phase.*

Figure 15: Data Type: Number

QCP 15DataTypeNumber.png

The user can add as many questions as required by clicking the  RTENOTITLE button, located in the bottom right corner, once the checklists are completed the user and select Save.

 

Figure 16: Add and Save

QCP 16Addandsave.png

The QCP checklist also has a drag and drop functionality and arrows in each checklist section that allows it to move from question to question in the order that the administrator wants.

 

Figure 17: Drag and Drop

QCP 17DragandDrop.png

 

After saving the QCP, if the administrator wants this checklist to be displayed in the Production Workbench application, it needs to select the Approved option.

 

Note: This function is exclusive for Supervisors.

 


Supervisor Authentication

The Supervisor Authentification must be completed with Employee Number and Password, it also displays the option Expire Previous Answers, this allows the Supervisor to stop the already answered questionnaire in a specific location and shift to be answered again.

 

Figure 18: Supervisor Authentification

QCP 18SupervisorAuthentification.png

As soon as the Supervisor Authentification is completed, the user must select Done,  the option (On version 1) is visible and active in the bottom right corner of the page;  this option can be deactivated only if the user doesn’t want the QCP checklist to be answered again.
 

Figure 19: On (Version)

QCP 19OnVersion .png

 

Note: Approval is needed to deactivate this option.

'P'lease refer to the Production Workbench documentation for more information. 


 

 

Revision History

Date Author Title Version Change Reference Approved by
4/01/2020 Marisol Vargas Technical Writer A1 Inicial version QCP SOP  
4/21/2020 Elaine Fonaro Technical Writer A2 Reviewed topics and structure  
4/22/2020 Elizabeth Armenta BSA A3 First Revision, Added Notes  
4/24/2020 Jaime Alvarez Developer A4 General Review  
4/24/2020 Fernanda Castilho Developer  A5 General Review, Added Notes  
4/30/2020   BSA A6   Elizabeth Armenta