MES Fuji Configuration

From 42Q
Revision as of 01:46, 21 May 2019 by Helena wang (talk | contribs)
Jump to navigation Jump to search

42Q Home > Shop Floor Control > Configuration > MES Fuju Configuration

Background

Per manufacturing industry best practice, a typical production line in 42Q’s MES consists of an  SFDC (Shop Floor Data Collector) station and a PTS (Parts Traceability System) workstation configured for advanced traceability. Together, the tools allow the operator to enable board scanning after the screen printer but before the SMT (Surface Mount Technology) machine. By combining the robust technology of Fuji’s Pick and Place machine (NXT/Aimex) with Fujitrax vendor software, component placement can be accomplished. However, this solution presents unique challenges. Currently, the Fuji line profiler does not read each board’s serials in Printed Circuit Boards (PCBs) containing multiple panels. The reader can only identify the first serial detected; the remaining serials are then autogenerated by Fujitrax (vendor software). Additionally, the automatically generated serials do not match consistently with the actual board serials. To track each board’s serials using Fujitrax, Fuji must request to link the panel, and each board within the panel, in order to avoid duplicated board scanning and linking efforts. When Fujitrax is integrated with 42Q’s intuitive Manufacturing Execution System, the above tasks can be accomplished efficiently. By associating the panel with each child board, Fuji MES is able to submit each board’s serials to SFDC (Shop Floor Data Collector) and PTS (Parts Traceability System) simultaneously.

 

Figure 1: Fuji Production Line Sample:
RTENOTITLE

 

 

 Solution and Working Process

 

When Fujitrax is integrated with 42Q’s intuitive Manufacturing Execution System, the above tasks can be accomplished efficiently. By associating the panel with each child board, Fuji MES is able to submit each board’s serials to SFDC (Shop Floor Data Collector) and PTS (Parts Traceability System) simultaneously.

Configuration Requirements

Before users can perform panel scanning, they must ensure the system is configured correctly.

System configuration includes: PTS configuration (web service URL), PTS location mapping, SFDC configuration (PC Setting), panel configuration,and Fuji-PTS line mapping. (See Figure 2)

Figure 2: Working Process

2 Working Process.png

1.2 Configure/Setting

 

1.2.1 PTS Configuration (PTS Web Service URL)

 

  1. To accessPTS Configuration, navigate toShop Floor Control > Configuration > MES-Fuji Configuration > PTS Configuration. See figure 3.

Figure 3: PTS Configuration

3 PTS Configuration.png

  1. PTS Web Service URL: The address of the PTS WebService. EnterPTS Web Service URL: http://yourserver_ip:port .Change “yourserver_ip" and “portto a valid IP and port.
  2. Enter the Employee ID and Employee Password.
  3. EnterthePTS User Name.
  4. Online Check BOM:Tick or untick the Online Check BOM. The default value is selected.
  5. Check ECN P/N:Tick or untick the Check ECN P/N. The default value is selected.
  6. Time Zone: Set the time zone for the PTS Production Line.
  7. Other items filled automatically.
  8. Select Update to save the configuration.
  9. Select Reset to clear the web service URL.

NOTE: The PTS Web service setting is used when scanning boards into the PTS system.

1.3 PTS Location Mapping

 

  1. Go to Shop Floor Control > Production Control > Production Setup(PTS) .
  2. Select the Production line name, and right click on the Workstation Name to open the sub-menu.
  3. Select Location Mapping.

Figure 4: PTS Location Mapping

4 PTS Location Mapping.png

  1. Define mapping details from the Location Mapping page of PTS. (See Figure 5, below.)

Figure 5: PTS Location Mapping

5 PTS Location Mapping.png

  1. Set the Production Line to “on-line.”

NOTE: In Workstation Setup, for the WS (Work Station) used for Mapping, ensure that the field defined as Scan from Scan Board/Panel is set to Scan Board. This is defined this way because it is a board that has a panel layout, therefore the board is the Parent. The details for the children will be captured in Fuji Trax.

1.4 SFDC PC Configuration

 

SFDC PC Configuration allows users to configure SFDC PC information. Users can add a new SFDC PC or modify an existing SFDC PC. This configuration is used when scanned boards information are saved into the SFDC.

  1. To access SFDC PC Configuration, navigate toShop Floor Control > Configuration > MES-Fuji Configuration > SFDC PC Configuration. (See Figure 6,7)

Figure 6: SFDC PC Config-AutoSFDC

6 SFDC PC Config-AutoSFDC.png

Figure 7: SFDC PC Config- Conduit

7 SFDC PC Config- Conduit.png

Users must select a Service Type. Choices include AutoSFDC or Conduit.

AutoSFDC Service Type

  • SFDC ID, SFDC Server, and Port are mandatory fields.
  • Add an SFDC ID. SFDC IDs cannot have the same name as other SFDC IDs only be used one time .
  • Select Edit to modify the SFDC ID. Edit the SFDC ID configuration by selecting Edit.
  • TheSFDC ID=MDS User ID which is used in PTS Location Mapping.

Conduit Service Type

  • Client ID, Conduit Server, Port are mandatory fields.
  • Add a Client ID, Note: Client IDs already in use cannot be used again. but cannot add a duplicate Client ID name.
  • Select Edit to modify the Client ID, Conduit Server, Port configuration

NOTE

Users can set the scan regulation within SFDC.

When scanning a panel with FujiTrax integration, users will not be able to scan at SFDC for the route step.

1.5 Panel Configuration

 

  1. To access Panel Configuration, navigate toShop Floor Control > Configuration > MES-Fuji Configuration > Panel Configuration.

1.5.1 Add Panel Configuration

 

  1. To add a scan side, select Add from the Panel Configuration main page.
  2. The Add Scan Side form displays:

Figure 8: Add Scan Side

8 Add Scan Side.png

  1. Enter the Part Number.
  2. Select the Rows, Columns, Panel Barcode, Use PTS, Use SFDC, Use FUJI, Board Side,2nd Side Mirror,Child Board(No SN), and FLP AutoScan. The default values are:
    • Rows- 1
    • Columns- 1
    • Use PTS- Checked
    • Use SFDC-Checked
    • Use FUJI- Checked
    • Board Side- 1st side=T, 2nd side=B
    • 2nd Side Mirror- no
    • FLP AutoScan- Checked
      1. Users can set the Scan Side to “B” (Bottom) or “T” (Top) by selecting the B or T icon.
      2. Select Submit to save.

NOTE: If the Part Number is incorrect, an error message will display liking “Part Number is incorrect, please re-enter.”

For time saving and efficiency, Uses can select an existing panel configuration then click the Copy Button and edit/modify some items to add a new panel configuration.

1.5.2 Edit Panel (Mix Board) Configuration

 

  1. Input the Part Number name at the Part Number text field and click the Search Icon. Then, select one Part Number from the search results.
  2. To edit a Scan Side, select Edit from the Panel Configuration main page.
  3. The Edit Scan Side form displays:

Figure 9: Edit Scan Side

9 Edit Scan Side.png

  • All fields are available to edit, except for the Part Number.
  • Edit the FLP AutoScan by checking the FLP AutoScan check mark for using FLP AutoScan, or leave it unchecked to deactivate FLP AutoScan feature.The new added panel configuration is in checked status.
  • Edit the Use PTS/Use SFDC/Use FUJI by activating the checkmark next to the fields. Once selected, users may scan boards into the PTS/SFDC/FUJI system. If the checkmark is not activated, the system will not send scanned board data into the open (skipped) system (i.e. PTS, SFDC, or FUJI) or leaving it open for not write the scan board information into PTS/SFDC/FUJI(skipped).
  • Edit the Board side 2nd side=T,1st side=B, or 1st side=T,2nd side=B. Note: Users may also set the Scan Side to “B” or “T” by selecting the B or T icon.
  • Edit the 2nd Side Mirror Yes or No.
  • Edit the number of the Child Boards (NO SN).
  • Select Submit to save.

1.6 Fuji-PTS Line Mapping

 

  1. To access Fuji-PTS Line Mapping, navigate toShop Floor Control > Configuration > MES-Fuji Configuration > Fuji-PTS Line Mapping. (See Figure 10)

Figure 10: Fuji-PTS line mapping

10 Fuji-PTS line mapping.png

  1. To add a Fuji-PTS line mapping, select Add from the Fuji PTS-Line Mapping main page.
  2. The Add form displays. (See Figure 11)

Figure 11: Add Fuji-PTS Line Mapping

11 Add Fuji-PTS Line Mapping.png

  • FUJITrax Line Name: Enter/Select a valid FujiTrax production Line.
  • PTS Line Name: Enter/Select a valid PTS production Line.
  • SMT Program Name: Enter the SMT Program Name.
  • PTS Workstation: Enter the PTS Workstation Name.
  • Online Check Bom: default is checked.
    1. Select Save to save the mapping information into the database, otherwise, select Cancel to cancel the action.

NOTE:

  • PTS Line Name,PTS WorkStation,FujiTrax Line Name are mandatory fields.
  • Duplicated mappings between the PTS Line and the Fujitrax Line are not permitted. If created, an error message will display “Duplicated record.”
  • The created mapping’s status is Not Started. The PGChange (Program change) module allows users to update the status from running to completed, then from not started to preparing, and then to running.
  • To edit a Fuji-PTS line mapping, select Edit from the Fuji-PTS Line Mapping main page. The Edit Fuji-PTS Line Mapping form displays. Only the FujiTrax Line Name cannot be edited.

1.7 Production line setting

 

  1. To access Production Line setting, navigate toShop Floor Control > Configuration > MES-Fuji Configuration > Production Line setting. (See Figure 12)

Figure 12: Production Line Setting

12 Production Line Setting.png

  1. To add a Production line setting, select Add from the Production Line Setting main page.
  2. The Add form displays. (See Figure 13)

Figure 13: Production Line Setting-add

13 Production Line Setting-add.png

  • FUJI Line Name: Enter/Select a valid FujiTrax production Line.
  • Fuji Machine Name: Enter a valid FuJi Machine Name.
  • PTS Line Name: Enter/Select a valid PTS production Line.
  • Lane No: Enter/Select the No for the Lane.
  • Testing Mode: Select Testing Mode or not, means check bom or not.
  • Online Check Bom: Check with Bom to verify the material.
  • Device ID: Enter the Device ID.
  • Next Location Name(T): Enter the next SFDC Location for Top side. If has more than one locations, please separate them by comme.
  • Next Location Name(B):Enter the next SFDC Location for Bottom side. If has more than one locations, please separate them by comme.
  •  
  • Auto Make ID: Select the Auto Make ID Check Button. if the check button is checked, please enter/select the items to set the barcode regulation.
  • Loading Material Verify: Has 5 check buttons,Material ON Hold, Material Not in Aml, Material Expired, Aml Expired,MSD Control. If the button is checked, the system will check the material status when loading material.
  • Click Save to submit the settings.
  • To edit a Production line setting, select Edit from the Production Line Setting main page.

Figure 14: Production Line Setting- Edit

14 Production Line Setting- Edit.png

Note:

If the PTS Line Name is null for the Production Line Setting, user must set the Fuji Line and PTS line mapping at the Fuji-PTS Line Mapping page(See 1.6).

Revision History

 

Date Author Title Version Change Reference Approved By
5/7/19 Helena Wang Technical Writer A Initial draft.  
5/7/19 Martha Jordan Technical Writer A English/format edit.