The main function of the Revision Change module is that it enables the user to change a unit revision. The module also provides the following portlets: User-Defined, User Revision, Add a Comment and add MEO (Manufacturing Engineering Order, i.e. ECO or Deviation number).
 
The main function of the Revision Change module is that it enables the user to change a unit revision. The module also provides the following portlets: User-Defined, User Revision, Add a Comment and add MEO (Manufacturing Engineering Order, i.e. ECO or Deviation number).
 +
 +
&nbsp;
  
 
The user defines the unit serial numbers to be updated by selecting from three different Rule Options:
 
The user defines the unit serial numbers to be updated by selecting from three different Rule Options:
Line 23: Line 26:
 
*'''Serial Number''' – Updates unit serial numbers by Serial Number  
 
*'''Serial Number''' – Updates unit serial numbers by Serial Number  
 
*'''Shop Order''' – Updates unit serial numbers by Shop Order  
 
*'''Shop Order''' – Updates unit serial numbers by Shop Order  
 +
 +
&nbsp;
  
 
The Revision Change portlet can be used with any rules; however, the user cannot add the same part number, serial number or shop order more than once. Users may add a shop order rule and then add the part number to the previously added shop order; this also applies to serial numbers. Revision Change will merge the part and serial numbers in order to avoid duplications.
 
The Revision Change portlet can be used with any rules; however, the user cannot add the same part number, serial number or shop order more than once. Users may add a shop order rule and then add the part number to the previously added shop order; this also applies to serial numbers. Revision Change will merge the part and serial numbers in order to avoid duplications.
 +
 +
&nbsp;
  
 
<u>'''Note'''</u>: This portlet has the following limitations:
 
<u>'''Note'''</u>: This portlet has the following limitations:
Line 37: Line 44:
 
&nbsp;
 
&nbsp;
  
'''Figure 1: MES Revision Change'''
+
<u>'''Note'''</u>: A user only has access to the modules assigned to his/her profile.
  
[[File:MES Revision Change.png|700px|MES Revision Change]]
+
&nbsp;
  
<u>'''Note'''</u>: A user only has access to the modules assigned to his/her profile.
+
= Revision Change&nbsp; =
  
&nbsp;
+
The main Revision Change page is display:
  
==== <span class="mw-headline" id="Revision_Change_Main_Page"><span class="mw-headline" id="Revision_Change_Main_Page"><span class="mw-headline" id="Revision_Change_Main_Page">Revision Change Main Page</span></span></span> ====
+
'''Figure 1: Revision Change Main Page'''
  
'''Figure 2: Revision Change Main Page'''
+
&nbsp;
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 02.jpg|700px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 02.jpg]]
+
&nbsp;
  
==== <span class="mw-headline" id="Adding_Rules"><span class="mw-headline" id="Adding_Rules"><span class="mw-headline" id="Adding_Rules">Adding Rules</span></span></span> ====
+
== <span class="mw-headline" id="Adding_Rules"><span class="mw-headline" id="Adding_Rules"><span class="mw-headline" id="Adding_Rules"><span class="mw-headline" id="Adding_Rules">Adding Rules</span></span></span></span> ==
  
 
1. Select the desired rule option from the '''Options''' drop-down box:
 
1. Select the desired rule option from the '''Options''' drop-down box:
Line 67: Line 74:
 
'''Figure 3: Part Number Browser'''
 
'''Figure 3: Part Number Browser'''
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 03.jpg|400px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 03.jpg]]
+
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 03.jpg|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 03.jpg]]
  
 
2. Enter the desired part number. Or, enter at least three characters to enable the shop order search.
 
2. Enter the desired part number. Or, enter at least three characters to enable the shop order search.
Line 79: Line 86:
 
'''Figure 4: Shop Floor Revision Change –Add Rules'''
 
'''Figure 4: Shop Floor Revision Change –Add Rules'''
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 04.jpg|700px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 04.jpg]]
+
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 04.jpg|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 04.jpg]]
  
 
4. The Option is added to the '''Rules''' section for easy verification.
 
4. The Option is added to the '''Rules''' section for easy verification.
Line 87: Line 94:
 
&nbsp;
 
&nbsp;
  
==== <span class="mw-headline" id="Removing_a_Rule"><span class="mw-headline" id="Removing_a_Rule"><span class="mw-headline" id="Removing_a_Rule">Removing a Rule</span></span></span> ====
+
==== <span class="mw-headline" id="Removing_a_Rule"><span class="mw-headline" id="Removing_a_Rule"><span class="mw-headline" id="Removing_a_Rule"><span class="mw-headline" id="Removing_a_Rule">Removing a Rule</span></span></span></span> ====
  
 
1. To remove a rule, select the desired Rule and select the '''Remove Rule''' button.
 
1. To remove a rule, select the desired Rule and select the '''Remove Rule''' button.
Line 93: Line 100:
 
'''Figure 5: Remove Rule'''
 
'''Figure 5: Remove Rule'''
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 05.jpg|700px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 05.jpg]]
+
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 05.jpg|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 05.jpg]]
  
 
2. A confirmation message is displayed, click '''Yes''' to confirm, or '''No''' to cancel.
 
2. A confirmation message is displayed, click '''Yes''' to confirm, or '''No''' to cancel.
Line 99: Line 106:
 
3. The rule is removed from the list.
 
3. The rule is removed from the list.
  
==== <span class="mw-headline" id="Current_User_Defined.2FRevision"><span class="mw-headline" id="Current_User_Defined.2FRevision"><span class="mw-headline" id="Current_User_Defined.2FRevision">Current User Defined/Revision</span></span></span> ====
+
==== <span class="mw-headline" id="Current_User_Defined.2FRevision"><span class="mw-headline" id="Current_User_Defined.2FRevision"><span class="mw-headline" id="Current_User_Defined.2FRevision"><span class="mw-headline" id="Current_User_Defined.2FRevision">Current User Defined/Revision</span></span></span></span> ====
  
 
'''Current User-Defined '''and&nbsp;'''Current User Revision '''(''optional'')''':''' These fields are used to enter record search criteria (filter and view values). The default ALL value indicates all values. A blank value is valid for the undefined field in the serial record.
 
'''Current User-Defined '''and&nbsp;'''Current User Revision '''(''optional'')''':''' These fields are used to enter record search criteria (filter and view values). The default ALL value indicates all values. A blank value is valid for the undefined field in the serial record.
Line 109: Line 116:
 
'''Figure 6: Current User Defined/Revision'''
 
'''Figure 6: Current User Defined/Revision'''
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 06.jpg|300px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 06.jpg]]
+
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 06.jpg|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 06.jpg]]
  
 
*'''Current User-Defined: ''' When the user selects '''Update''', the User-Defined field is updated with a new user-defined value of up to 20 characters.  
 
*'''Current User-Defined: ''' When the user selects '''Update''', the User-Defined field is updated with a new user-defined value of up to 20 characters.  
 
*'''Current User-Revision: ''' When the user selects '''Update''', the User-Revision field is updated with a new revision value of up to 10 characters.  
 
*'''Current User-Revision: ''' When the user selects '''Update''', the User-Revision field is updated with a new revision value of up to 10 characters.  
  
==== <span class="mw-headline" id="Summary_.E2.80.93_Viewing_and_Removing_Serial_Numbers_Affected_by_Rules"><span class="mw-headline" id="Summary_.E2.80.93_Viewing_and_Removing_Serial_Numbers_Affected_by_Rules"><span class="mw-headline" id="Summary_.E2.80.93_Viewing_and_Removing_Serial_Numbers_Affected_by_Rules">Summary – Viewing and Removing Serial Numbers Affected by Rules</span></span></span> ====
+
==== <span class="mw-headline" id="Summary_.E2.80.93_Viewing_and_Removing_Serial_Numbers_Affected_by_Rules"><span class="mw-headline" id="Summary_.E2.80.93_Viewing_and_Removing_Serial_Numbers_Affected_by_Rules"><span class="mw-headline" id="Summary_.E2.80.93_Viewing_and_Removing_Serial_Numbers_Affected_by_Rules"><span class="mw-headline" id="Summary_.E2.80.93_Viewing_and_Removing_Serial_Numbers_Affected_by_Rules">Summary – Viewing and Removing Serial Numbers Affected by Rules</span></span></span></span> ====
  
 
After rules have been added, it is possible to view serial numbers affected by the rules and to remove them.
 
After rules have been added, it is possible to view serial numbers affected by the rules and to remove them.
Line 130: Line 137:
 
'''Figure 8: View Serial Numbers'''
 
'''Figure 8: View Serial Numbers'''
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 08.jpg|700px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 08.jpg]]
+
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 08.jpg|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 08.jpg]]
  
 
&nbsp;
 
&nbsp;
Line 140: Line 147:
 
'''Figure 9: Remove Serial'''
 
'''Figure 9: Remove Serial'''
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 09.jpg|700px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 09.jpg]]
+
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 09.jpg|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 09.jpg]]
  
 
&nbsp;
 
&nbsp;
Line 148: Line 155:
 
3. The selected serial numbers will be removed from the Revision Change upon final Update.
 
3. The selected serial numbers will be removed from the Revision Change upon final Update.
  
==== <span class="mw-headline" id="New_.E2.80.93_User_Defined.2FRevision.2FComment.2FMEO.23"><span class="mw-headline" id="New_.E2.80.93_User_Defined.2FRevision.2FComment.2FMEO.23"><span class="mw-headline" id="New_.E2.80.93_User_Defined.2FRevision.2FComment.2FMEO.23">New – User Defined/Revision/Comment/MEO#</span></span></span> ====
+
==== <span class="mw-headline" id="New_.E2.80.93_User_Defined.2FRevision.2FComment.2FMEO.23"><span class="mw-headline" id="New_.E2.80.93_User_Defined.2FRevision.2FComment.2FMEO.23"><span class="mw-headline" id="New_.E2.80.93_User_Defined.2FRevision.2FComment.2FMEO.23"><span class="mw-headline" id="New_.E2.80.93_User_Defined.2FRevision.2FComment.2FMEO.23">New – User Defined/Revision/Comment/MEO#</span></span></span></span> ====
  
 
This section defines the new updates that will be performed to the serial numbers affected by the rules added in the previous sections.
 
This section defines the new updates that will be performed to the serial numbers affected by the rules added in the previous sections.
Line 156: Line 163:
 
'''Figure 10: New User Defined/Revision/Comment/MEO#'''
 
'''Figure 10: New User Defined/Revision/Comment/MEO#'''
  
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 10.jpg|350px|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 10.jpg]]
+
[[File:SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 10.jpg|SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 10.jpg]]
  
 
<u>'''Note'''</u>: Either the User Defined or User Revision update is required, yet both can be updated if desired. If the boxes for both User Defined and User Revision are checked, the '''Update''' button is disabled.
 
<u>'''Note'''</u>: Either the User Defined or User Revision update is required, yet both can be updated if desired. If the boxes for both User Defined and User Revision are checked, the '''Update''' button is disabled.
Line 177: Line 184:
  
 
&nbsp;
 
&nbsp;
 +
  [[Category:Pages with broken file links]]
  
 
= <span class="mw-headline" id="Appendix_A"><span class="mw-headline" id="Appendix_A"><span class="mw-headline" id="Appendix_A">Appendix A</span></span></span> =
 
= <span class="mw-headline" id="Appendix_A"><span class="mw-headline" id="Appendix_A"><span class="mw-headline" id="Appendix_A">Appendix A</span></span></span> =

Revision as of 23:01, 11 January 2024

42Q Home > Shop Floor Control > Configuration > Revision Change Maintenance
 

 

 

 

Shop Floor Control
Configuration
Revision Change Maintenance
Version MES15.79
Revision D1
 

 

 

 


Introduction 

The main function of the Revision Change module is that it enables the user to change a unit revision. The module also provides the following portlets: User-Defined, User Revision, Add a Comment and add MEO (Manufacturing Engineering Order, i.e. ECO or Deviation number).

 

The user defines the unit serial numbers to be updated by selecting from three different Rule Options:

  • Part Number – Updates unit serial numbers by Part Number
  • Serial Number – Updates unit serial numbers by Serial Number
  • Shop Order – Updates unit serial numbers by Shop Order

 

The Revision Change portlet can be used with any rules; however, the user cannot add the same part number, serial number or shop order more than once. Users may add a shop order rule and then add the part number to the previously added shop order; this also applies to serial numbers. Revision Change will merge the part and serial numbers in order to avoid duplications.

 

Note: This portlet has the following limitations:

  • Revision changes are not allowed for ERP-Interface Shop Orders or for unit serial numbers tied to them.
  • Revision changes are not allowed for WIP units with a finished status.

 

To access the Revision Change Maintenance, navigate to Shop Floor Control > Configuration > Shop Floor Configuration > Revision Change.

 

Note: A user only has access to the modules assigned to his/her profile.

 

Revision Change 

The main Revision Change page is display:

Figure 1: Revision Change Main Page

 

 

Adding Rules

1. Select the desired rule option from the Options drop-down box:

  • Part Number: After selecting the Part Number Option, the Browse button is enabled.

Enter at least 3 characters to enable the part number search.

  • Serial Number: Enter a valid WIP serial number in the space provided.
  • Shop Order Number: After selecting the Shop Order Option, the Browse button is enabled.

Select the Browse button to select the desired Shop Order number.

Figure 3: Part Number Browser

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 03.jpg

2. Enter the desired part number. Or, enter at least three characters to enable the shop order search.

Note: If invalid information is provided in any of the above rules, an error message is displayed.

3. After selecting the desired Rule Option(s), click the Add Rule button

 

Figure 4: Shop Floor Revision Change –Add Rules

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 04.jpg

4. The Option is added to the Rules section for easy verification.

5. The user may add as many Rules as desired, as long as they do not conflict with the limitations defined in this guide.

 

Removing a Rule

1. To remove a rule, select the desired Rule and select the Remove Rule button.

Figure 5: Remove Rule

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 05.jpg

2. A confirmation message is displayed, click Yes to confirm, or No to cancel.

3. The rule is removed from the list.

Current User Defined/Revision

Current User-Defined and Current User Revision (optional): These fields are used to enter record search criteria (filter and view values). The default ALL value indicates all values. A blank value is valid for the undefined field in the serial record.

After adding the desired rules, the serial numbers can be filtered in the Current form. Filter the serial numbers by User Defined or by User Revision fields or choose the option All to update all serial numbers selected.

 

Figure 6: Current User Defined/Revision

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 06.jpg

  • Current User-Defined: When the user selects Update, the User-Defined field is updated with a new user-defined value of up to 20 characters.
  • Current User-Revision: When the user selects Update, the User-Revision field is updated with a new revision value of up to 10 characters.

Summary – Viewing and Removing Serial Numbers Affected by Rules

After rules have been added, it is possible to view serial numbers affected by the rules and to remove them.

1. To view serial numbers affected by the Rules, Select Print/Export. A report is generated listing the serial numbers.

 

Figure 7: Serial Numbers Summary

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 07.jpg

 

Figure 8: View Serial Numbers

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 08.jpg

 

1. To remove a Serial Number from the Selected Serial Numbers section, double-click it to move it to the Removed Items section.

 

Figure 9: Remove Serial

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 09.jpg

 

2. When the desired serial number(s) have been selected, click on Ok to confirm (or Cancel to abort).

3. The selected serial numbers will be removed from the Revision Change upon final Update.

New – User Defined/Revision/Comment/MEO#

This section defines the new updates that will be performed to the serial numbers affected by the rules added in the previous sections.

1. Define New updates to be performed:

Figure 10: New User Defined/Revision/Comment/MEO#

SOP-5-I-MDS0042-C RA1 MDS MDS Revision Change 10.jpg

Note: Either the User Defined or User Revision update is required, yet both can be updated if desired. If the boxes for both User Defined and User Revision are checked, the Update button is disabled.

  • User Defined: Data to replace the current data for the affected serial numbers. 20 character limit.
  • N/A: Check only if update to the User Defined field is not desired.
  • User Revision: Enter the desired Revision, or double-click the field to select the desired value for Revision Controlled Part Numbers.
  • N/A: Check only if update to the User Revision field is not desired.
  • Comment: The comment entered will be attached to all serial numbers affected by the Rules.
  • MEO#: Manufacturing Engineering Order (ADMEO) activity records will be added to the serial numbers affected by the rules.

As a general rule, any/all Revision changes performed are to be defined in an ECO, ECN, Deviation, or other traceable document. The document number should be included in the MEO# field as to add the activity records to the serial number for tracking the serial numbers affected by the documented change.

  • Print: Check to print the affected serial numbers.

 

 

Appendix A

Acronyms

MDS (Manufacturing Data System (JAVA Technology))

GLAD (Global Administration)

LDAP (Lightweight Directory Access Protocol)

MFG (Manufacturing Data Systems)

MES (Manufacturing Execution System)

PRAC (Process Access)

SPC (Statistical Process Control)

 

Appendix B

Glossary

Access Control

A module that will set the permissions for users and external customers of 42Q

Administrator

The System Administrator has full access - all plants, all reports, all users.

Component

A component is a specific piece of data that appears on a label, for example: bar code, part numbers, graphic images, lines, or text. Hence, label components are broken down into several different types: text, graphic images, MES database values, or a combination of text and database values.

Framework

In software development, a framework is a defined support structure in which another software project can be organized and developed. A framework may include support programs, code libraries, a scripting language, or other software to help develop and glue together the different components of a software project.

Shop Floor Configuration

The rules used to define how Shop Floor collects data provides analysis, controls the processing, and maintains unit histories

Username

The username is the SiteMinder username (or a partial string)