Difference between revisions of "MES Fuji Configuration"

From 42Q
Jump to navigation Jump to search
Line 4: Line 4:
 
 
 
 
 
<center>'''Shop Floor Control'''</center> <center>'''Configuration'''</center> <center>'''MES Fuji Configuration&nbsp;'''</center> <center>'''Version MES 15.71'''</center> <center>'''Revision B1'''</center> <p style="text-align: center;">&nbsp;</p> <p style="text-align: center;">&nbsp;</p> <p style="text-align: center;">&nbsp;</p>  
 
<center>'''Shop Floor Control'''</center> <center>'''Configuration'''</center> <center>'''MES Fuji Configuration&nbsp;'''</center> <center>'''Version MES 15.71'''</center> <center>'''Revision B1'''</center> <p style="text-align: center;">&nbsp;</p> <p style="text-align: center;">&nbsp;</p> <p style="text-align: center;">&nbsp;</p>  
= <span class="mw-headline" id="Background"><span class="mw-headline" id="Background"><span class="mw-headline" id="Background">Background</span></span></span> =
+
= <span class="mw-headline" id="Background"><span class="mw-headline" id="Background"><span class="mw-headline" id="Background"><span class="mw-headline" id="Background">Background</span></span></span></span> =
  
Per manufacturing industry best practice, a typical production line in 42Q’s MES consists of an &nbsp;SFDC (Shop Floor Data Collector) station and a PTS (Parts Traceability System) workstation configured for advanced traceability. Together, the tools allow the operator to enable board scanning after the screen printer but before the SMT (Surface Mount Technology) machine. By combining the robust technology of Fuji’s Pick and Place machine (NXT/Aimex) with Fujitrax vendor software, component placement can be accomplished. However, this solution presents unique challenges. Currently, the Fuji line profiler does not read each board’s serials in Printed Circuit Boards (PCBs) containing multiple panels. The reader can only identify the first serial detected; the remaining serials are then autogenerated by Fujitrax (vendor software). Additionally, the automatically generated serials do not match consistently with the actual board serials. To track each board’s serials using Fujitrax, Fuji must request to link the panel, and each board within the panel, in order to avoid duplicated board scanning and linking efforts. When Fujitrax is integrated with 42Q’s intuitive Manufacturing Execution System, the above tasks can be accomplished efficiently. By associating the panel with each child board, Fuji MES is able to submit each board’s serials to SFDC (Shop Floor Data Collector) and PTS (Parts Traceability System) simultaneously.
+
Per manufacturing industry best practice, a typical production line in 42Q’s MES consists of a Shop Floor Data Collector&nbsp;station and a Part&nbsp;Traceability System&nbsp;workstation configured for advanced traceability. Together, the tools allow the operator to enable board scanning after the screen printer but before the SMT (Surface Mount Technology) machine. By combining the robust technology of Fuji’s Pick and Place machine (NXT/Aimex) with Fujitrax vendor software, component placement can be accomplished. However, this solution presents unique challenges. Currently, the Fuji line profiler does not read each board’s serials in Printed Circuit Boards (PCBs) containing multiple panels. The reader can only identify the first serial detected; the remaining serials are then autogenerated by Fujitrax (vendor software). Additionally, the automatically generated serials do not match consistently with the actual board serials. To track each board’s serials using Fujitrax, Fuji must request to link the panel, and each board within the panel, in order to avoid duplicated board scanning and linking efforts. When Fujitrax is integrated with 42Q’s intuitive Manufacturing Execution System, the above tasks can be accomplished efficiently. By associating the panel with each child board, Fuji MES is able to submit each board’s serials to SFDC (Shop Floor Data Collector) and PTS (Parts Traceability System) simultaneously.
  
 
&nbsp;
 
&nbsp;
Line 16: Line 16:
 
&nbsp;
 
&nbsp;
  
= <span class="mw-headline" id="_Solution_and_Working_Process"><span class="mw-headline" id="_Solution_and_Working_Process"><span class="mw-headline" id="_Solution_and_Working_Process">&nbsp;Solution and Working Process</span></span></span> =
+
= <span class="mw-headline" id="_Solution_and_Working_Process"><span class="mw-headline" id="_Solution_and_Working_Process"><span class="mw-headline" id="_Solution_and_Working_Process"><span class="mw-headline" id="_Solution_and_Working_Process">&nbsp;Solution and Working Process</span></span></span></span> =
  
 
&nbsp;
 
&nbsp;
Line 24: Line 24:
 
'''Configuration Requirements'''
 
'''Configuration Requirements'''
  
Before users&nbsp; perform panel scanning, they must ensure the system is configured correctly.
+
Before users perform panel scanning, they must ensure the system is configured correctly.
  
System configuration includes: PTS configuration (web service URL), PTS location mapping, SFDC configuration (PC Setting), panel configuration,and Fuji-PTS line mapping. (See '''Figure 2''')
+
System configuration includes: PTS configuration (web service URL), PTS location mapping, SFDC configuration (PC Setting), panel configuration, and Fuji-PTS line mapping. (See '''Figure 2''')
  
 
&nbsp;
 
&nbsp;
Line 34: Line 34:
 
[[File:2 Working Process.png|800px|2 Working Process.png]]
 
[[File:2 Working Process.png|800px|2 Working Process.png]]
  
== <span class="mw-headline" id="Configure.2FSetting"><span class="mw-headline" id="Configure.2FSetting"><span class="mw-headline" id="Configure.2FSetting">Configure/Setting</span></span></span> ==
+
== <span class="mw-headline" id="Configure.2FSetting"><span class="mw-headline" id="Configure.2FSetting"><span class="mw-headline" id="Configure.2FSetting"><span class="mw-headline" id="Configure.2FSetting">Configure/Setting</span></span></span></span> ==
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="_Traceability_Configuration_.28PTS_Web_Service_URL.29"><span class="mw-headline" id="_PTS_Configuration_.28PTS_Web_Service_URL.29"><span class="mw-headline" id="_PTS_Configuration_.28PTS_Web_Service_URL.29">&nbsp;Traceability&nbsp;Configuration (PTS Web Service URL)</span></span></span> ===
+
=== <span class="mw-headline" id="_Traceability_Configuration_.28PTS_Web_Service_URL.29"><span class="mw-headline" id="_Traceability_Configuration_.28PTS_Web_Service_URL.29"><span class="mw-headline" id="_PTS_Configuration_.28PTS_Web_Service_URL.29"><span class="mw-headline" id="_PTS_Configuration_.28PTS_Web_Service_URL.29">&nbsp;Traceability&nbsp;Configuration (PTS Web Service URL)</span></span></span></span> ===
  
 
&nbsp;
 
&nbsp;
  
#To access&nbsp;'''Traceability Configuration''', navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Traceability&nbsp;Configuration'''. See figure 3.  
+
#To access&nbsp;'''Traceability Configuration''', navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Traceability&nbsp;Configuration'''.  
 +
 
 +
See figure 3.
  
 
&nbsp;
 
&nbsp;
Line 55: Line 57:
 
<li>Enter the '''Employee ID '''and '''Employee Password'''.</li>
 
<li>Enter the '''Employee ID '''and '''Employee Password'''.</li>
 
<li>Enter&nbsp;the'''&nbsp;PTS User Name'''''<b>.</b>''</li>
 
<li>Enter&nbsp;the'''&nbsp;PTS User Name'''''<b>.</b>''</li>
<li>'''Online Check BOM''':Tick or untick the Online Check BOM'''. '''The default value is selected.</li>
+
<li>'''Online Check BOM''': Tick or untick the Online Check BOM'''. '''The default value is selected.</li>
<li>'''Check ECN P/N''':Tick or untick the '''Check ECN P/N'''. The default value is selected.</li>
+
<li>'''Check ECN P/N''': Tick or untick the '''Check ECN P/N'''. The default value is selected.</li>
 
<li>'''Time Zone''': Set the time zone for the PTS Production Line.</li>
 
<li>'''Time Zone''': Set the time zone for the PTS Production Line.</li>
<li>Other items filled automatically.</li>
+
<li>Other items are filled in automatically.</li>
 
<li>Select '''Update''' to save the configuration.</li>
 
<li>Select '''Update''' to save the configuration.</li>
 
<li>Select '''Reset '''to clear the web service URL.</li>
 
<li>Select '''Reset '''to clear the web service URL.</li>
Line 67: Line 69:
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="PTS_Location_Mapping"><span class="mw-headline" id="PTS_Location_Mapping"><span class="mw-headline" id="PTS_Location_Mapping">Traceability Location Mapping</span></span></span> ==
+
== <span class="mw-headline" id="Traceability_Location_Mapping"><span class="mw-headline" id="PTS_Location_Mapping"><span class="mw-headline" id="PTS_Location_Mapping"><span class="mw-headline" id="PTS_Location_Mapping">Traceability Location Mapping</span></span></span></span> ==
  
 
&nbsp;
 
&nbsp;
  
 
#Go to '''Shop Floor Control > Production Control''' > '''Production Setup'''.  
 
#Go to '''Shop Floor Control > Production Control''' > '''Production Setup'''.  
#Select the Production line name, and right click on the Workstation Name to open the sub-menu.  
+
#Select the Production line name, and right-click on the Workstation Name to open the sub-menu.  
 
#Select '''Location Mapping'''.  
 
#Select '''Location Mapping'''.  
  
Line 97: Line 99:
 
</ol>
 
</ol>
  
'''<span style="text-decoration:underline;">NOTE</span>''': In Workstation Setup, for the WS (Work Station) used for Mapping, ensure that the field defined as Scan from Scan Board/Panel is set to Scan Board. This is defined this way because it is a board that has a panel layout, therefore the board is the Parent. The details for the children will be captured in Fuji Trax.
+
'''<span style="text-decoration:underline;">Note</span>''': In Workstation Setup, for the WS (Work Station) used for Mapping, ensure that the field defined as Scan from Scan Board/Panel is set to Scan Board. This is defined this way because it is a board that has a panel layout, therefore the board is the Parent. The details for the children will be captured in Fuji Trax.
 +
 
 +
&nbsp;
  
== <span class="mw-headline" id="_SFDC_PC_Configuration"><span class="mw-headline" id="_SFDC_PC_Configuration"><span class="mw-headline" id="_SFDC_PC_Configuration">&nbsp;Traceability Shop Floor&nbsp;Configuration</span></span></span> ==
+
== <span class="mw-headline" id="_Traceability_Shop_Floor_Configuration"><span class="mw-headline" id="_SFDC_PC_Configuration"><span class="mw-headline" id="_SFDC_PC_Configuration"><span class="mw-headline" id="_SFDC_PC_Configuration">&nbsp;Traceability Shop Floor&nbsp;Configuration</span></span></span></span> ==
  
Traceability Shop Floor Configuration allows users to configure SFDC PC information. Users can add a new SFDC PC or modify an existing SFDC PC. This configuration is used when scanned boards information are saved into the SFDC.
+
Traceability Shop Floor Configuration allows users to configure SFDC PC information. Users can add a new SFDC PC or modify an existing SFDC PC. This configuration is used when scanned boards information is saved into the SFDC.
  
#To access Traceabilty Shop Floor'''&nbsp;Configuration,''' navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Traceabilty Shop Floor Configuration'''. (See '''Figure 6,7''')  
+
#To access Traceability Shop Floor'''&nbsp;Configuration,''' navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Traceability Shop Floor Configuration'''. (See '''Figure 6,7''')  
  
 
&nbsp;
 
&nbsp;
Line 126: Line 130:
  
 
*'''SFDC ID''', '''SFDC Server,''' and '''Port''' are mandatory fields.  
 
*'''SFDC ID''', '''SFDC Server,''' and '''Port''' are mandatory fields.  
*Add an SFDC ID. SFDC IDs cannot have the same name as other SFDC IDs only be used one time .  
+
*Add an SFDC ID. SFDC IDs cannot have the same name as other SFDC IDs only be used one time.  
 
*Select Edit to modify the SFDC ID. Edit the SFDC ID configuration  
 
*Select Edit to modify the SFDC ID. Edit the SFDC ID configuration  
*The&nbsp;'''SFDC ID=MDS User ID''' which is used in PTS Location Mapping.  
+
*The&nbsp;'''SFDC ID=MDS User ID'''&nbsp;is used in PTS Location Mapping.  
  
 
'''Conduit Service Type'''
 
'''Conduit Service Type'''
Line 142: Line 146:
 
When scanning a panel with FujiTrax integration, users will not be able to scan at SFDC for the route step.
 
When scanning a panel with FujiTrax integration, users will not be able to scan at SFDC for the route step.
  
== <span class="mw-headline" id="_Panel_Configuration"><span class="mw-headline" id="_Panel_Configuration"><span class="mw-headline" id="_Panel_Configuration">&nbsp;Panel Configuration</span></span></span> ==
+
== <span class="mw-headline" id="_Panel_Configuration"><span class="mw-headline" id="_Panel_Configuration"><span class="mw-headline" id="_Panel_Configuration"><span class="mw-headline" id="_Panel_Configuration">&nbsp;Panel Configuration</span></span></span></span> ==
  
 
#To access '''Panel Configuration, '''navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Panel Configuration.'''  
 
#To access '''Panel Configuration, '''navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Panel Configuration.'''  
Line 148: Line 152:
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="_Add_Panel_Configuration"><span class="mw-headline" id="_Add_Panel_Configuration"><span class="mw-headline" id="_Add_Panel_Configuration">&nbsp;Add Panel Configuration</span></span></span> ===
+
=== <span class="mw-headline" id="_Add_Panel_Configuration"><span class="mw-headline" id="_Add_Panel_Configuration"><span class="mw-headline" id="_Add_Panel_Configuration"><span class="mw-headline" id="_Add_Panel_Configuration">&nbsp;Add Panel Configuration</span></span></span></span> ===
  
 
&nbsp;
 
&nbsp;
  
#To add a scan side, select '''Add '''from the '''Panel Configuration '''main page.  
+
#To add a scanning side, select '''Add '''from the '''Panel Configuration '''main page.  
 
#The '''Add Scan Side '''form displays:  
 
#The '''Add Scan Side '''form displays:  
  
Line 164: Line 168:
 
<ol start="3">
 
<ol start="3">
 
<li>Enter the '''Part Number'''.</li>
 
<li>Enter the '''Part Number'''.</li>
<li>Select the '''Rows''', '''Columns''', '''Panel Barcode''', '''Use PTS''', '''Use SFDC''', '''Use FUJI''', '''Board Side''','''2nd Side Mirror''','''Child Board(No SN)''', and '''FLP AutoScan'''. The default values are:</li>
+
<li>Select the '''Rows''', '''Columns''', '''Panel Barcode''', '''Use PTS''', '''Use SFDC''', '''Use FUJI''', '''Board Side''','''2nd Side Mirror''',&nbsp;'''Child Board(No SN)''', and '''FLP AutoScan'''. The default values are:</li>
 
</ol>
 
</ol>
 
<ul style="margin-left: 40px;">
 
<ul style="margin-left: 40px;">
Line 182: Line 186:
 
</ol>
 
</ol>
  
'''<span style="text-decoration:underline;">NOTE</span>''': If the Part Number is incorrect, an error message will display . &nbsp;
+
'''<span style="text-decoration:underline;">NOTE</span>''': If the Part Number is incorrect, an error message will display. &nbsp;
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Edit_Panel_.28Mix_Board.29_Configuration"><span class="mw-headline" id="Edit_Panel_.28Mix_Board.29_Configuration"><span class="mw-headline" id="Edit_Panel_.28Mix_Board.29_Configuration">Edit Panel (Mix Board) Configuration</span></span></span> ===
+
=== <span class="mw-headline" id="Edit_Panel_.28Mix_Board.29_Configuration"><span class="mw-headline" id="Edit_Panel_.28Mix_Board.29_Configuration"><span class="mw-headline" id="Edit_Panel_.28Mix_Board.29_Configuration"><span class="mw-headline" id="Edit_Panel_.28Mix_Board.29_Configuration">Edit Panel (Mix Board) Configuration</span></span></span></span> ===
  
 
&nbsp;
 
&nbsp;
Line 203: Line 207:
 
<ul style="margin-left: 40px;">
 
<ul style="margin-left: 40px;">
 
<li>All fields are available to edit, except for the Part Number.</li>
 
<li>All fields are available to edit, except for the Part Number.</li>
<li>Edit the FLP AutoScan by checking the '''FLP AutoScan '''check mark for using FLP AutoScan, or leave it unchecked to deactivate FLP AutoScan feature.The new added panel configuration is in checked status.</li>
+
<li>Edit the FLP AutoScan by checking the '''FLP AutoScan '''checkmark for using FLP AutoScan, or leave it unchecked to deactivate the FLP AutoScan feature. The newly added panel configuration is in checked status.</li>
<li>Edit the '''Use PTS/Use SFDC/Use FUJI''' by activating the checkmark next to the fields. Once selected, users may scan boards into the PTS/SFDC/FUJI system. If the checkmark is not activated, the system will not send scanned board data into the open (skipped) system (i.e. PTS, SFDC, or FUJI) or leaving it open for not write the scan board information into PTS/SFDC/FUJI(skipped).</li>
+
<li>Edit the '''Use PTS/Use SFDC/Use FUJI''' by activating the checkmark next to the fields. Once selected, users may scan boards into the PTS/SFDC/FUJI system. If the checkmark is not activated, the system will not send scanned board data into the open (skipped) system (i.e. PTS, SFDC, or FUJI) or leave it open for not writing the scan board information into PTS/SFDC/FUJI(skipped).</li>
 
<li>Edit the Board side '''2nd side=T,1st side=B''', or '''1st side=T,2nd side=B'''. '''Note''': Users may also set the Scan Side to “B” or “T” by selecting the '''B '''or '''T '''icon.</li>
 
<li>Edit the Board side '''2nd side=T,1st side=B''', or '''1st side=T,2nd side=B'''. '''Note''': Users may also set the Scan Side to “B” or “T” by selecting the '''B '''or '''T '''icon.</li>
 
<li>Edit the '''2nd Side Mirror''' Yes or No.</li>
 
<li>Edit the '''2nd Side Mirror''' Yes or No.</li>
Line 215: Line 219:
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="_Fuji-PTS_Line_Mapping"><span class="mw-headline" id="_Fuji-PTS_Line_Mapping"><span class="mw-headline" id="_Fuji-PTS_Line_Mapping">&nbsp;MES-Fuji&nbsp;Line Mapping</span></span></span> ==
+
== <span class="mw-headline" id="_MES-Fuji_Line_Mapping"><span class="mw-headline" id="_Fuji-PTS_Line_Mapping"><span class="mw-headline" id="_Fuji-PTS_Line_Mapping"><span class="mw-headline" id="_Fuji-PTS_Line_Mapping">&nbsp;MES-Fuji&nbsp;Line Mapping</span></span></span></span> ==
  
 
&nbsp;
 
&nbsp;
Line 251: Line 255:
 
</ol>
 
</ol>
  
'''<span style="text-decoration:underline;">NOTE</span>''':
+
'''<span style="text-decoration:underline;">Note</span>''':
  
*'''PTS Line Name''','''PTS''' '''WorkStation''','''FujiTrax Line Name''' are mandatory fields.  
+
*'''PTS Line Name''',&nbsp;'''PTS''' '''WorkStation''',&nbsp;'''FujiTrax Line Name''' are mandatory fields.  
 
*Duplicated mappings between the PTS Line and the Fujitrax Line are not permitted. If created, an error message will display “Duplicated record.”  
 
*Duplicated mappings between the PTS Line and the Fujitrax Line are not permitted. If created, an error message will display “Duplicated record.”  
*The created mapping’s status is '''Not Started'''. The '''PGChange '''(Program change) module allows users to update the status from running to completed, then from not started to preparing, and then to running.  
+
*The created mapping’s status is '''Not Started'''. The '''PGChange '''(Program change) module allows users to update the status from running to complete, then from not started to preparing, and then to running.  
 
*To edit a Fuji-PTS line mapping, select '''Edit '''from the '''Fuji-PTS Line Mapping '''main page. The '''Edit Fuji-PTS Line Mapping '''form displays. Only the '''FujiTrax Line Name''' cannot be edited.  
 
*To edit a Fuji-PTS line mapping, select '''Edit '''from the '''Fuji-PTS Line Mapping '''main page. The '''Edit Fuji-PTS Line Mapping '''form displays. Only the '''FujiTrax Line Name''' cannot be edited.  
  
Line 262: Line 266:
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="_Production_line_setting"><span class="mw-headline" id="_Production_line_setting"><span class="mw-headline" id="_Production_line_setting">&nbsp;Production line setting</span></span></span> ==
+
== <span class="mw-headline" id="_Production_line_setting"><span class="mw-headline" id="_Production_line_setting"><span class="mw-headline" id="_Production_line_setting"><span class="mw-headline" id="_Production_line_setting">&nbsp;Production line setting</span></span></span></span> ==
  
 
&nbsp;
 
&nbsp;
  
#To access '''Production Line setting, '''navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Production Line setting. '''(See '''Figure 12''')  
+
#To access the&nbsp;'''Production Line setting, '''navigate to&nbsp;'''Shop Floor Control > Configuration > MES-Fuji Configuration > Production Line setting. '''(See '''Figure 12''')  
  
 
&nbsp;
 
&nbsp;
Line 276: Line 280:
 
&nbsp;
 
&nbsp;
 
<ol start="2">
 
<ol start="2">
<li>To add a Production line setting, select '''Add '''from the '''Production Line Setting '''main page.</li>
+
<li>To add a Production line setting, select '''Add '''from the '''Production Line Setting the&nbsp;'''main page.</li>
 
<li>The '''Add '''form displays. (See '''Figure 13''')</li>
 
<li>The '''Add '''form displays. (See '''Figure 13''')</li>
 
</ol>
 
</ol>
Line 292: Line 296:
 
<li>'''PTS Line Name: '''Enter/Select a valid PTS production Line.</li>
 
<li>'''PTS Line Name: '''Enter/Select a valid PTS production Line.</li>
 
<li>'''Lane No''': Enter/Select the No for the Lane.</li>
 
<li>'''Lane No''': Enter/Select the No for the Lane.</li>
<li>'''Testing''' '''Mode''': Select Testing Mode or not, means check bom or not.</li>
+
<li>'''Testing''' '''Mode''': Select Testing Mode or not, which means check BOM or not.</li>
 
<li>'''Online Check Bom''': Check with Bom to verify the material.</li>
 
<li>'''Online Check Bom''': Check with Bom to verify the material.</li>
 
<li>'''Device ID: '''Enter the Device ID.</li>
 
<li>'''Device ID: '''Enter the Device ID.</li>
<li>'''Next Location Name(T): '''Enter the next SFDC Location for Top side. If has more than one locations, please separate them by comme.</li>
+
<li>'''Next Location Name(T): '''Enter the next SFDC Location for Topside. It has more than one location, please separate them by a comma.</li>
<li>'''Next Location Name(B):'''Enter the next SFDC Location for Bottom side. If has more than one locations, please separate them by comme.</li>
+
<li>'''Next Location Name(B):&nbsp;'''Enter the next SFDC Location for the Bottom side. It has more than one location, please separate them by a comma.</li>
 
<li>'''Auto Make ID: '''Select the Auto Make ID Check Button. if the check button is checked, please enter/select the items to set the barcode regulation.</li>
 
<li>'''Auto Make ID: '''Select the Auto Make ID Check Button. if the check button is checked, please enter/select the items to set the barcode regulation.</li>
<li>'''Loading Material Verify: '''Has 5 check buttons,'''Material ON Hold, Material Not in Aml, Material Expired, Aml Expired,MSD Control. If the button is checked, the system will check the material status when loading material.'''</li>
+
<li>'''Loading Material Verify: '''Has 5 check buttons,&nbsp;'''Material ON Hold, Material Not in Aml, Material Expired, Aml Expired, MSD Control. If the button is checked, the system will check the material status when loading the material.'''</li>
 
</ul>
 
</ul>
 
<ol start="3" style="margin-left: 40px;">
 
<ol start="3" style="margin-left: 40px;">
 
<li>Click '''Save''' to submit the settings.</li>
 
<li>Click '''Save''' to submit the settings.</li>
<li>To edit a Production line setting, select '''Edit '''from the '''Production Line Setting '''main page.</li>
+
<li>To edit a Production line setting, select '''Edit '''from the '''Production Line Setting the&nbsp;'''main page.</li>
 
</ol>
 
</ol>
  
Line 313: Line 317:
 
&nbsp;
 
&nbsp;
  
'''<span style="text-decoration:underline;">Note</span>''':If the PTS Line Name is null for the Production Line Setting, user must set the Fuji Line and PTS line mapping at the Fuji-PTS Line Mapping page.
+
'''<span style="text-decoration:underline;">Note</span>''': If the PTS Line Name is null for the Production Line Setting, the user must set the Fuji Line and PTS line mapping at the Fuji-PTS Line Mapping page.
  
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="FujiTrax_Profiling_Setting"><span class="mw-headline" id="FujiTrax_Profiling_Setting"><span class="mw-headline" id="FujiTrax_Profiling_Setting">FujiTrax Profiling Setting</span></span></span> ==
+
== <span class="mw-headline" id="FujiTrax_Profiling_Setting"><span class="mw-headline" id="FujiTrax_Profiling_Setting"><span class="mw-headline" id="FujiTrax_Profiling_Setting"><span class="mw-headline" id="FujiTrax_Profiling_Setting">FujiTrax Profiling Setting</span></span></span></span> ==
  
 
&nbsp;
 
&nbsp;
Line 335: Line 339:
 
&nbsp;
 
&nbsp;
 
<ol start="2">
 
<ol start="2">
<li>At the Profiling setting page, set the Traget, Coneyor, Camera, and Panel ID.</li>
+
<li>At the Profiling setting page, set the Target, Conveyor, Camera, and Panel ID.</li>
 
</ol>
 
</ol>
  
Line 354: Line 358:
  
 
&nbsp;
 
&nbsp;
 +
 +
----
  
 
&nbsp;
 
&nbsp;

Revision as of 17:55, 22 November 2021

42Q Home > Shop Floor Control > Configuration > MES Fuji Configuration

 

Shop Floor Control
Configuration
MES Fuji Configuration 
Version MES 15.71
Revision B1

 

 

 

Background

Per manufacturing industry best practice, a typical production line in 42Q’s MES consists of a Shop Floor Data Collector station and a Part Traceability System workstation configured for advanced traceability. Together, the tools allow the operator to enable board scanning after the screen printer but before the SMT (Surface Mount Technology) machine. By combining the robust technology of Fuji’s Pick and Place machine (NXT/Aimex) with Fujitrax vendor software, component placement can be accomplished. However, this solution presents unique challenges. Currently, the Fuji line profiler does not read each board’s serials in Printed Circuit Boards (PCBs) containing multiple panels. The reader can only identify the first serial detected; the remaining serials are then autogenerated by Fujitrax (vendor software). Additionally, the automatically generated serials do not match consistently with the actual board serials. To track each board’s serials using Fujitrax, Fuji must request to link the panel, and each board within the panel, in order to avoid duplicated board scanning and linking efforts. When Fujitrax is integrated with 42Q’s intuitive Manufacturing Execution System, the above tasks can be accomplished efficiently. By associating the panel with each child board, Fuji MES is able to submit each board’s serials to SFDC (Shop Floor Data Collector) and PTS (Parts Traceability System) simultaneously.

 

Figure 1: Fuji Production Line Sample:
RTENOTITLE

 

 

 Solution and Working Process

 

When Fujitrax is integrated with 42Q’s intuitive Manufacturing Execution System, the above tasks can be accomplished efficiently. By associating the panel with each child board, Fuji MES is able to submit each board’s serials to SFDC (Shop Floor Data Collector) and PTS (Parts Traceability System) simultaneously.

Configuration Requirements

Before users perform panel scanning, they must ensure the system is configured correctly.

System configuration includes: PTS configuration (web service URL), PTS location mapping, SFDC configuration (PC Setting), panel configuration, and Fuji-PTS line mapping. (See Figure 2)

 

Figure 2: Working Process

2 Working Process.png

Configure/Setting

 

 Traceability Configuration (PTS Web Service URL)

 

  1. To access Traceability Configuration, navigate to Shop Floor Control > Configuration > MES-Fuji Configuration > Traceability Configuration.

See figure 3.

 

Figure 3: Traceability Configuration

3 PTS Configuration.png

 

  1. PTS Web Service URL: The address of the PTS WebService. Enter PTS Web Service URL: http://yourserver_ip:port .Change “yourserver_ip" and “port” to a valid IP and port.
  2. Enter the Employee ID and Employee Password.
  3. Enter the PTS User Name.
  4. Online Check BOM: Tick or untick the Online Check BOM. The default value is selected.
  5. Check ECN P/N: Tick or untick the Check ECN P/N. The default value is selected.
  6. Time Zone: Set the time zone for the PTS Production Line.
  7. Other items are filled in automatically.
  8. Select Update to save the configuration.
  9. Select Reset to clear the web service URL.

Note: The PTS Web service setting is used when scanning boards into the PTS system.

 

Traceability Location Mapping

 

  1. Go to Shop Floor Control > Production Control > Production Setup.
  2. Select the Production line name, and right-click on the Workstation Name to open the sub-menu.
  3. Select Location Mapping.

 

Figure 4: Traceability Location Mapping

4 PTS Location Mapping.png

 

  1. Define mapping details from the Location Mapping page of PTS. (See Figure 5, below.)

 

Figure 5: Traceability Location Mapping

5 PTS Location Mapping.png

 

  1. Set the Production Line to “on-line.”

Note: In Workstation Setup, for the WS (Work Station) used for Mapping, ensure that the field defined as Scan from Scan Board/Panel is set to Scan Board. This is defined this way because it is a board that has a panel layout, therefore the board is the Parent. The details for the children will be captured in Fuji Trax.

 

 Traceability Shop Floor Configuration

Traceability Shop Floor Configuration allows users to configure SFDC PC information. Users can add a new SFDC PC or modify an existing SFDC PC. This configuration is used when scanned boards information is saved into the SFDC.

  1. To access Traceability Shop Floor Configuration, navigate to Shop Floor Control > Configuration > MES-Fuji Configuration > Traceability Shop Floor Configuration. (See Figure 6,7)

 

Figure 6: SFDC PC Config-AutoSFDC

6 SFDC PC Config-AutoSFDC.png

 

 

Figure 7: SFDC PC Config- Conduit

7 SFDC PC Config- Conduit.png

 

Users must select a Service Type. Choices include AutoSFDC or Conduit.

AutoSFDC Service Type

  • SFDC ID, SFDC Server, and Port are mandatory fields.
  • Add an SFDC ID. SFDC IDs cannot have the same name as other SFDC IDs only be used one time.
  • Select Edit to modify the SFDC ID. Edit the SFDC ID configuration
  • The SFDC ID=MDS User ID is used in PTS Location Mapping.

Conduit Service Type

  • Client ID, Conduit Server, Port are mandatory fields.
  • Add a Client ID, Note: Client IDs already in use cannot be used again. but cannot add a duplicate Client ID name.
  • Select Edit to modify the Client ID, Conduit Server, Port configuration

NOTE

Users can set the scan regulation within SFDC.

When scanning a panel with FujiTrax integration, users will not be able to scan at SFDC for the route step.

 Panel Configuration

  1. To access Panel Configuration, navigate to Shop Floor Control > Configuration > MES-Fuji Configuration > Panel Configuration.

 

 Add Panel Configuration

 

  1. To add a scanning side, select Add from the Panel Configuration main page.
  2. The Add Scan Side form displays:

 

Figure 8: Add Scan Side

8 Add Scan Side.png

 

  1. Enter the Part Number.
  2. Select the Rows, Columns, Panel Barcode, Use PTS, Use SFDC, Use FUJI, Board Side,2nd Side MirrorChild Board(No SN), and FLP AutoScan. The default values are:
  • Rows- 1
  • Columns- 1
  • Use PTS- Checked
  • Use SFDC-Checked
  • Use FUJI- Checked
  • Board Side- 1st side=T, 2nd side=B
  • 2nd Side Mirror- no
  • FLP AutoScan- Checked
  1. Users can set the Scan Side to “B” (Bottom) or “T” (Top) by selecting the B or T icon.
  2. Select Submit to save.
  3. For time saving and efficiency, Uses can select an existing panel configuration then click the Copy Button and edit/modify some items to add a new panel configuration.

NOTE: If the Part Number is incorrect, an error message will display.  

 

Edit Panel (Mix Board) Configuration

 

  1. Input the Part Number name at the Part Number text field and click the Search Icon. Then, select one Part Number from the search results.
  2. Select Edit from the Panel Configuration main page.
  3. The Edit Scan Side form displays:

 

Figure 9: Edit Scan Side

9 Edit Scan Side.png

 

  • All fields are available to edit, except for the Part Number.
  • Edit the FLP AutoScan by checking the FLP AutoScan checkmark for using FLP AutoScan, or leave it unchecked to deactivate the FLP AutoScan feature. The newly added panel configuration is in checked status.
  • Edit the Use PTS/Use SFDC/Use FUJI by activating the checkmark next to the fields. Once selected, users may scan boards into the PTS/SFDC/FUJI system. If the checkmark is not activated, the system will not send scanned board data into the open (skipped) system (i.e. PTS, SFDC, or FUJI) or leave it open for not writing the scan board information into PTS/SFDC/FUJI(skipped).
  • Edit the Board side 2nd side=T,1st side=B, or 1st side=T,2nd side=B. Note: Users may also set the Scan Side to “B” or “T” by selecting the B or T icon.
  • Edit the 2nd Side Mirror Yes or No.
  • Edit the number of the Child Boards (NO SN).
  1. Select Submit to save.

 

 MES-Fuji Line Mapping

 

  1. To access MES-Fuji Line Mapping, navigate to Shop Floor Control > Configuration > MES-Fuji Configuration > MES-Fuji Line Mapping. (See Figure 10)

 

Figure 10: MES-Fuji line mapping

10 Fuji-PTS line mapping.png

 

  1. Select Add from the MES-Fuji Line Mapping main page.
  2. The Add form displays. (See Figure 11)

 

Figure 11: Add Fuji-PTS Line Mapping

11 Add Fuji-PTS Line Mapping.png

 

  • FUJITrax Line Name: Enter/Select a valid FujiTrax production Line.
  • PTS Line Name: Enter/Select a valid PTS production Line.
  • SMT Program Name: Enter the SMT Program Name.
  • PTS Workstation: Enter the PTS Workstation Name.
  • Online Check Bom: default is checked.
  1. Select Save to save the mapping information into the database, otherwise, select Cancel to cancel the action.

Note:

  • PTS Line NamePTS WorkStationFujiTrax Line Name are mandatory fields.
  • Duplicated mappings between the PTS Line and the Fujitrax Line are not permitted. If created, an error message will display “Duplicated record.”
  • The created mapping’s status is Not Started. The PGChange (Program change) module allows users to update the status from running to complete, then from not started to preparing, and then to running.
  • To edit a Fuji-PTS line mapping, select Edit from the Fuji-PTS Line Mapping main page. The Edit Fuji-PTS Line Mapping form displays. Only the FujiTrax Line Name cannot be edited.

 

 

 Production line setting

 

  1. To access the Production Line setting, navigate to Shop Floor Control > Configuration > MES-Fuji Configuration > Production Line setting. (See Figure 12)

 

Figure 12: Production Line Setting

12 Production Line Setting.png

 

  1. To add a Production line setting, select Add from the Production Line Setting the main page.
  2. The Add form displays. (See Figure 13)

 

Figure 13: Production Line Setting-add

13 Production Line Setting-add.png

 

  • FUJI Line Name: Enter/Select a valid FujiTrax production Line.
  • Fuji Machine Name: Enter a valid FuJi Machine Name.
  • PTS Line Name: Enter/Select a valid PTS production Line.
  • Lane No: Enter/Select the No for the Lane.
  • Testing Mode: Select Testing Mode or not, which means check BOM or not.
  • Online Check Bom: Check with Bom to verify the material.
  • Device ID: Enter the Device ID.
  • Next Location Name(T): Enter the next SFDC Location for Topside. It has more than one location, please separate them by a comma.
  • Next Location Name(B): Enter the next SFDC Location for the Bottom side. It has more than one location, please separate them by a comma.
  • Auto Make ID: Select the Auto Make ID Check Button. if the check button is checked, please enter/select the items to set the barcode regulation.
  • Loading Material Verify: Has 5 check buttons, Material ON Hold, Material Not in Aml, Material Expired, Aml Expired, MSD Control. If the button is checked, the system will check the material status when loading the material.
  1. Click Save to submit the settings.
  2. To edit a Production line setting, select Edit from the Production Line Setting the main page.

 

Figure 14: Production Line Setting- Edit

14 Production Line Setting- Edit.png

 

Note: If the PTS Line Name is null for the Production Line Setting, the user must set the Fuji Line and PTS line mapping at the Fuji-PTS Line Mapping page.

 

FujiTrax Profiling Setting

 

The FujiTrax Profiling Setting/ configuration is for All In One manual scan. Integrate with SFDC and PTS.

  1. Log in the FujiTrax, open the main page, then select Profiling Setting.

 

Figure 15: Profiling Setting page

Figure 15- Profiling Setting page.png

 

 

  1. At the Profiling setting page, set the Target, Conveyor, Camera, and Panel ID.

 

Figure 16: Profiling Setting -Set Target

Figure 16- Profiling Setting -Set Traget.png

 

  1. Select the Profiling Setting dialog window, select Manual Handy Scan Mode.

Figure 17: Profiling Setting - Set Manual Handy Scan Mode

Figure 17- Profiling Setting - Set Manual Handy Scan Mode.png