Difference between revisions of "SOP-42Q-MES0049 SMT Part Traceability"
Helena wang (talk | contribs) |
Helena wang (talk | contribs) |
||
Line 525: | Line 525: | ||
| | ||
− | |||
− | This section is going to | + | === <span class="mw-headline" id="Feeder_Registry"><span class="mw-headline" id="Feeder_Registry"><span class="mw-headline" id="Feeder_Registry"><span class="mw-headline" id="Feeder_Registry"><span class="mw-headline" id="Feeder_Registry"><span class="mw-headline" id="Feeder_Registry"><span class="mw-headline" id="Feeder_Registry">Feeder Registry</span></span></span></span></span></span></span> === |
+ | |||
+ | This section is going to introduce: | ||
*How to add feeder record | *How to add feeder record | ||
Line 533: | Line 534: | ||
*How to maintain a feeder name | *How to maintain a feeder name | ||
− | # To access the Feeder Registry page, navigate to '''Production | + | # To access the Feeder Registry page, navigate to '''Production > 100% Traceability > SMT Machine Part Traceability > Feeder Registry'''. |
− | |||
<br/> '''Figure 23: Feeder Registry''' | <br/> '''Figure 23: Feeder Registry''' | ||
Line 546: | Line 546: | ||
| | ||
− | ==== <span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder">Create feeder</span></span></span></span></span> ==== | + | ==== <span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder"><span class="mw-headline" id="Create_feeder">Create feeder</span></span></span></span></span></span></span> ==== |
1. Select '''Create Feeder'''. A new sub-page will display. | 1. Select '''Create Feeder'''. A new sub-page will display. | ||
Line 577: | Line 577: | ||
| | ||
− | ==== <span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry">Change Feeder/Feeder Registry</span></span></span></span></span> ==== | + | ==== <span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry"><span class="mw-headline" id="Change_Feeder.2FFeeder_Registry">Change Feeder/Feeder Registry</span></span></span></span></span></span></span> ==== |
1. Select a feeder by checking the box to the left of the Feeder Barcode. | 1. Select a feeder by checking the box to the left of the Feeder Barcode. | ||
Line 593: | Line 593: | ||
5. Enter the Feeder name if needed. | 5. Enter the Feeder name if needed. | ||
− | 6. To set maintenance dates automatically, select '''AUTO'''. | + | 6. To set the maintenance dates automatically, select '''AUTO'''. |
7. To disable feeder maintenance, select '''Unlimit'''. | 7. To disable feeder maintenance, select '''Unlimit'''. | ||
Line 605: | Line 605: | ||
| | ||
− | ==== <span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder">Delete feeder</span></span></span></span></span> ==== | + | ==== <span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder"><span class="mw-headline" id="Delete_feeder">Delete feeder</span></span></span></span></span></span></span> ==== |
1. Select a feeder by checking the box to the left of the Feeder Barcode. | 1. Select a feeder by checking the box to the left of the Feeder Barcode. | ||
Line 621: | Line 621: | ||
| | ||
− | ==== <span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework">Feeder Rework</span></span></span></span></span> ==== | + | ==== <span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework"><span class="mw-headline" id="Feeder_Rework">Feeder Rework</span></span></span></span></span></span></span> ==== |
It is very important to maintain feeders as schedule or usage due to the fact that every feeder has a particular lifespan. Traceability WEB provides two options for scheduling purposes; Maximum Usage Times and Maintenance Periods. | It is very important to maintain feeders as schedule or usage due to the fact that every feeder has a particular lifespan. Traceability WEB provides two options for scheduling purposes; Maximum Usage Times and Maintenance Periods. | ||
Line 647: | Line 647: | ||
5. Change the '''Min alarm Usage''' and '''Min alarm Maintenance Period'''. | 5. Change the '''Min alarm Usage''' and '''Min alarm Maintenance Period'''. | ||
− | 6. Service Description: Select | + | 6. Service Description: Select the service description from the drop-down list. The description log can be added when the user reworks or maintains the function. |
7. The user can select '''Add''' to add the new service description. | 7. The user can select '''Add''' to add the new service description. | ||
Line 653: | Line 653: | ||
8. Select '''Send''' to update the system. | 8. Select '''Send''' to update the system. | ||
− | + | <u>'''Note'''</u>: An "in-use" feeder cannot edited/deleted/reworked. | |
| |
Revision as of 01:06, 18 May 2021
42Q Home > Production > SMT Part Traceability
This edition applies to MES 15.69 Application and all subsequent releases and modifications until otherwise indicated in new revisions.
Contents
Production
The Parts Traceability System (Traceability) is one of the applications within the MES suite of tools. It was developed to meet the demands of customers to provide component level traceability as well as quality controls. This system plays a very important role in automating the production lines and raising productivity as well as enforcing rigorous product quality control. It has been implemented to many plants across the globe. This application and the features it provides continue to evolve, as the changing technologies used for the SMT process equipment tools become more detailed and rich in functionality.
SMT Machine Part Traceability
General Notes
1. This Work Instruction is a basic general training guide and is not meant to teach the process flow for individual plant or department functionality. Individual 42Q sites may have minor or specific process changes that will be documented at the site level.
2. Online help is available in Traceability.
Pre-Requisites
1. Completed SOP-5-I-MES0028-C_RA1_PTS_Incoming_Material_Labeling
2. Read SOP-5-I-MES0044-C_RA1_PTS_Glossary
3. Java Runtime Environment 1.5 or above installed.
4. Microsoft Excel 2000 or above installed.
Overview
EZ-Picklist is a web-based interface to collect and manipulate SMT placement programs into Traceability for material verification against the BOM. It is compatible with different brands of SMT machine models as listed follow. Please consult with Traceability Regional Support for full listing of machine type and compatible models.
Machine Type | Model | Software Name & Version | File Name Extension |
Universal | GSM | UPS +
2.5.2 |
ci2 |
Universal | HSP4796 | UCT-53 | ncz |
Universal | HSP4797 | UCT-53 | pca |
Panasonic | CM402 | PT200 | txt |
Panasonic | DT401 | PT200 | txt |
Fuji | CP643 | Unicam 6.2 | pgo/db |
Fuji | CP642 | Unicam 6.2 | pgo/db |
Fuji | FCP6 | Unicam 6.2 | pgo/db |
Fuji | FIP2 | Unicam 6.2 | pgo/db |
Fuji | FIP3 | Unicam 6.2 | pgo/db |
Fuji | QP242 | Unicam 6.2 | pgo/db |
Fuji | QP341/QP351 | Unicam 6.2 | pgo/db |
Fuji | NP133/NP153 | Unicam 6.2 | pgo/db |
Fuji | CP643 | FujiFlexa2.4.0.7 | pgo/xml |
Fuji | CP642 | FujiFlexa2.4.0.7 | pgo/xml |
Fuji | FCP6 | FujiFlexa2.4.0.7 | pgo/xml |
Fuji | FIP2 | FujiFlexa2.4.0.7 | pgo/xml |
Fuji | FIP3 | FujiFlexa2.4.0.7 | pgo/xml |
Fuji | QP242 | FujiFlexa2.4.0.7 | pgo/xml |
Fuji | QP341/QP351 | FujiFlexa2.4.0.7 | pgo/xml |
Fuji | NP133/NP153 | FujiFlexa2.4.0.7 | pgo/xml |
EZ Picklist
1. To access the EZ Picklist page, navigate to Production > 100% Traceability > SMT Machine Part Traceability > EZpicklist.
Figure 1 : EZ Picklist Main Page
- Select the Machine Models from the dropdown list, then select select Picklist to locate the desired material placement file.
Figure 2 : Select the Picklist File
- Select Select Files to select the SMT program file name. Please refer to SMT job profile prepared by SMT Engineer for the file name for each SMT machine.
- The EZpicklist Name will auto-complete with the same as the file name, user can modify the EZpicklist name.
- Select Upload . Details of the picklist will display.
Figure 3 : Picklist Details Window
Figure 3- Picklist Details Window.png
All 42Q P/N, Station, Feeder, Count, and Designator are encoded in the SMT placement program prepared by the SMT Engineer.
- Select the 1st production side and/or 2nd production side (as per picklist setup for production environment).
- Select the High Value option and the Lead Free option checkbox associated with each individual material part number if required.
Note: For the Lead Free option, there is a setting named Lead Free PN Prefix at the System Setting page to identify if the material is lead free or not.
The ‘Lead Free PN Prefix’ option at the function ‘System Setting’ (default value is ‘LF’). For example, if users change its value to ‘LF, PF’ then those part numbers starting with 'LF' or ‘PF’ will be identified to ‘Lead Free’.
Figure 3a: Lead System Setting
Figure 3b: EZpicklist Auto check Leadfree
EZPicklist Auto check Leadfree.png
- Select Send Picklist to send the picklist to the Traceability server.
- After the picklist is submitted to the server, message prompt.
- Select OK to confirm it.
Figure 4: Picklist Created Succeed
Figure 4- Picklist Created succeed.png
- Select Loading List to send the picklist to the local driver(by default).
- The loading list file will show or not show the Nozzle according to the Loading List Nozzle Template value at the System Setting. When Loading List Nozzle Template is ‘Yes’, the loading list file with Nozzle field, see Figure 5, if loading list Nozzle Template is ‘No’, the loading list file without Nozzle field, see Figure 6.
Note: The default path for Loading List report is customizable. The local plant can contact the MES Support team to do the customization.
Figure 5 : Picklist Loading List with Nozzle
4 Loading list with Nozzle.png
Figure 6 : Picklist Loading List without Nozzle
5 Loading list without Nozzle.png
Note: The Surface Mount Devices (SMD) Loading List cannot be used as a control document without stamp/sign by authorized personnel defined by the plant such as the SMT production line supervisor/team leader. This is designed to be used for materials loading reference only.
Hand-load Picklist
The users can download the Picklist template file for the Hand-Load machine Model.
- Select Download to download the handload picklist template file.
Figure 7: Download Handload Picklist Template File
Figure- Download handload picklist template.png
- Edit the handload picklist template file with production data.
- Select HANDLOAD from the Machine Models dropdown menu,
- Select Select Picklist to open the prepared handload picklist file.
- Select Upload to show the detailed information.
Figure 8 : Handload Picklist Detailed information
Figure-Upload Handload picklist.png
- Select Send Picklist to save the handload pick to the system.
Workstation Type
With this module, the user is allowed to add/delete/change a workstation type.
1. To access the Workstation Type page, navigate to Production > 100% Traceability > SMT Machine Part Traceability > Workstation Type.
Figure 9: Workstation Type
2. Select Add Workstation Type. Thiswill add a new line in the list.
Figure 10 : Add Workstation Type
3. Enter the Workstation Type Name, Max Station, and Max Table, and then select Update to add a new workstation type.
4. Double click on the existing Workstation Type Name. The information will display and is available to edit. Change the desired information, and then select Update to change a workstation type.
5. Click the red cross on the right to confirm the deletion of a workstation type.
Figure 11: Delete Workstation Type
Show BOM
This module allows the user to view BOM, disable BOM, or enable BOM.
1. To access the Show BOM page, navigate to Production > 100% Traceability > SMT Machine Part Traceability > Show BOM.
Figure 12: Show BOM
All BOM P/N (ECN) in the system will list out in pages. The user can search a BOM by BOM P/N or BOM ECN, and/or by Active or Disabled.
2. When the user selects the left checkbox to select an item, Enable, Disable, and Show will become available.
Enable/Disable BOM
1. Search the BOM by Enable/Disable and select Go. All Enabled/Disabled BOM will be displayed.
2. Select the left Checkbox on target BOM and then select the button Disable/Enable.
Figure 13: Disable BOM
Show BOM
This function allows the user to view all existing items under the selected BOM.
1. Search the BOM.
2. Select the left checkbox on the target BOM and then select Show.
Figure 14: Show BOM
Note: Before MES 15.69, the system used PrintQ Interface(sent BOM data to MDS database) for the general rule for all Oracle standard BOM printed to Traceability,If there is any BOM already being used in production then we can't print the same BOM again with the same ECN. Please refer to this PrintQ Interface to see general rule for all Oracle standard BOM printed to Traceability,If there is any BOM already being used in production then we can't print the same BOM again reference with the same ECN
From 15.69 there is one new option for users to transfer MDS Work order BOM data to PTS Database directly.
Note: Please contact the local support team to help set the central DB configuration (Module=PTS_MESR) to transfer MDS Work order BOM to PTS Database directly. This is a Prerequisites that the plant has to use the Oracle-MES101 Work Order interface.
Figure 14a: Central DB Configuration
Compare BOM and Picklist
This module is designed to verify that the designators in the BOM are consistent with the ones in the SMT program. It also lists the differences between the two.
1. To access the Compare BOM and Picklist page, navigate to Production > 100% Traceability > SMT Machine Part Traceability > Compare BOM and Picklist.
Figure 15: Compare BOM and Picklist
Search by Line Name
1. Enter the Line Name.
2. Enter the BOM number into the BOM textbox.
3. Select the correct BOM ECN from the BOM ECN drop-down list.
4. Select Search. The results will be shown on the right.
5. If BOM does not match the Picklist, the following screen will display. (See Figure 16)
Figure 16: Compare by Line- No Match
Search By Picklist Name
1. Select or enter the Picklist Name.
2. Enter the BOM number in the BOM textbox.
3. Select a correct BOM ECN from the drop-down list.
4. Select Search. The result shown on the right will be slightly different with this option checked or unchecked. (See figure 17).
Figure 17: Compare by Picklist Name- No Match
P/N Extra Info
This module allows the user to flag the high value material and define whether or not to track and show an orientation picture for a particular material during the process of material loading.
1. To access the P/N Extra Info page, navigate to Production > 100% Traceability > SMT Machine Part Traceability > P/N Extra Info.
Figure 18: P/N Extra Info
2. The user can perform a search by entering the target part number and/or defining parameters, such as Orientation, Track, and High Value.
3. The user can change the information by selecting an item and double clicking on its part number (see figure 19).
Figure 19: P/N Extra Info- Update
- Part Number: The part number selected by the user. Display only.
- Description: Description of the item selected by the user. Display only.
- Orientation: Whether or not to show the orientation picture when loading this material. select Yes or No.(Note: This option will be disabled only when " Show Orientation Picture=Yes" under the System Setting page.
- Track: Whether or not to track the material. Select Yes or No.
- High Value: Define whether or not the selected item is a high-value item. Select Yes or No.(Note: This option will be disabled only when "High-Value Mark=Yes" under the System Setting page.
- High Value: Define whether or not to control the MPN information when jointing this material in the material queue function. Select Yes or No.
- Lot code Control: Define whether or not to control the lot code information when jointing this material in the material queue function. Select Yes or No.
- Traceability level: Define the traceability level. Select Single Scan or Scan Point or 100% traceability.
- Update: Select this button to save the configuration.
- Cancel: Select this button to go back to the previous window without saving.
Feeder Type Registry
This module is used to add or maintain the feeder type. The following instructions introduce the user to a sample to teach how to operate the function.
1. To access the Feeder Type Registry page, navigate to Production > 100% Traceability > SMT Machine Part Traceability > Feeder Type Registry.
Figure 20: Feeder Type Registry
Add Feeder Type
This section will instruct the user on how feeder type can be added.
1. Select Add feeder Type. A new line will be added.
Figure 21: Add Feeder Type
- Select the Machine Type Name.
- Enter the Feeder Type name
- Select Update. The feeder type will be created.
Note: A warning message "This feeder type:(TEST) has already existed!" will display if the feeder name already exists. A feeder type must be matched with the SMT program.
Search Feeder Type
1. Enter the Feeder Type in the search box, and then select GO.
2. The related feeder type will be displayed.
Feeder Type Maintenance
This section will instruct the user on how to maintain an existing feeder type.
Figure 22: Feeder Type Maintenance
1. Double click on the feeder type under the Feeder Type column.
2. Enter the feeder regulation which applies to the associated feeder type.
3. Enter the feeder maximum usage into the Max Usage field and the maintenance period into the Maint Period field.
4. Enter the minimum usage times into Minimum Alarm Usage. When the usage times are the same as the defined minimum usage times, the feeder name will be marked with yellow at the load material module.
5. Enter the minimum usage days into the Minimum Alarm Maintenance Period. When the usage days are equal to the defined minimum usage days, the feeder name will be marked with yellow at the Load Material module.
6. Select Update to update all associated feeder type records.
7. By selecting History, the user can review the change information for this feeder type.
Feeder Registry
This section is going to introduce:
- How to add feeder record
- How to lookup the feeder maintenance record
- How to maintain a feeder name
- To access the Feeder Registry page, navigate to Production > 100% Traceability > SMT Machine Part Traceability > Feeder Registry.
Figure 23: Feeder Registry
2. All feeder information will display.
3. Expired feeder rows will be highlighted in red.
Create feeder
1. Select Create Feeder. A new sub-page will display.
Figure 24: Create New Feeder
2. Enter/Select the Feeder Type.
3. Enter the Feeder Barcode.
4. Enter the number of feeders to be generated using the newly provided feeder barcode. The default value is 1.
For example:
Select Feeder Type: BFE-32 +
Input Feeder Barcode: 10001Number of Feeder: 3
I.e. Three sequence order feeder records will be created (10001, 10002, and 10003)
5. Select Create.
Change Feeder/Feeder Registry
1. Select a feeder by checking the box to the left of the Feeder Barcode.
2. Select Feeder Registry.
Figure 25: Feeder Registry
5. Enter the Feeder name if needed.
6. To set the maintenance dates automatically, select AUTO.
7. To disable feeder maintenance, select Unlimit.
8. Enter a specific maintenance date.
9. Select the Change the button to update the feeder name and maintenance date.
10. Select the Cancel button to return to the feeder registry report page.
Delete feeder
1. Select a feeder by checking the box to the left of the Feeder Barcode.
2. Select Delete Feeder.
Figure 26: Delete Feeder
3. Select OK to confirm the deletion of the selected feeder.
Feeder Rework
It is very important to maintain feeders as schedule or usage due to the fact that every feeder has a particular lifespan. Traceability WEB provides two options for scheduling purposes; Maximum Usage Times and Maintenance Periods.
1. Select a feeder by checking the box to the left of the Feeder Barcode.
2. Select Feeder Rework.
Figure 27: Feeder Registry- Feeder Rework
Figure 28: Feeder Rework- Main
3. Enter the feeder name.
4. Change the Maximum Usage and Maintenance Period as defined in the feeder registry schedule ruled by SMT engineers.
5. Change the Min alarm Usage and Min alarm Maintenance Period.
6. Service Description: Select the service description from the drop-down list. The description log can be added when the user reworks or maintains the function.
7. The user can select Add to add the new service description.
8. Select Send to update the system.
Note: An "in-use" feeder cannot edited/deleted/reworked.
JIG Registry
Prerequisites
- Set production offline.
- This function only works on request.
- Please set "Jig Control = Yes" in the System Setting page before using this function.
Overview
- This function which supports tooling has been installed in the SMT machine correctly and is for a specific product.
- The following is an example, which shows the user how to operate this function:
NOTE: To begin to use the Jig function, the user needs to set the Jig in this module first.
1. To access the Jig Registry page, navigate to Production >
SMT Machine Part Traceability >
JIG Registry.
NOTE: The enabled and disabled jigs have different colors in the status field.
Figure 29: JIG Registry
Add JIG
1. Select Add JIG located above the JIG Barcode list.
Figure 30: Add JIG
2. Input the JIG barcode, JIG name, and the description and select Update to add a new JIG.
NOTE: The status will be enabled by default.
Update JIG
1. Double click on the jig barcode to enable editing.
Figure 31: Update JIG Information
NOTE: The jig barcode is read-only.
2. Input the JIG Name, Description, and Status.
3. Select Update.
NOTE: The JIG status can change from either enabled to disabled, or disabled to enabled.
NOTE: An "In Use" JIG cannot be changed.
Define JIG mapping
1. If the JIG barcode is in enabled status, select Define to maintenance the mapping.
2. Select Create to add a new mapping for the Jig.
Figure 32: JIG Registry- Mapping
Update JIG Mapping
1. Double-click on the existing mapping to update it.
Figure 33: Update JIG Mapping
2. Change the Picklist Name, Side, Workstation Type, BOM P/N, and Status.
3. Click the button Update to change the mapping.
4. Click the button Cancel to cancel.
Machine Registry
This module is intended to instruct users on how to manage the machines.
1. To access the Machine Registry page, navigate to Production >
SMT Machine Part Traceability >
Machine Registry.
Figure 34: Machine Registry
Create a New Machine
1. Select Create located above the Machine No. list to create a new line.
2. Enter the Machine No, Machine Barcode, Machine Owner, and Description, and select one Machine type, then select Update.
3. The new machine status is active by default.
Figure 35: Machine Registry- Add
Search a Machine
1. SelectMachine Barcode or Machine type in the Search By drop-down box. Enter the necessary content, and select the status, then select the search ICON on the right of the main screen. The results will display in the list below.
2. Select Fuzzy. The search results will be the machines with barcode names that contain the search contents.
Update a Machine
1. Double click the line to be edited.
2. Change the appropriate information, and then select Update to update the Machine.
3. The machine status can change from either active to inactive or inactive to active.
Figure 36: Machine Registry-Update
Document Revision History
Date | Author | Title | Version | Change Reference | Approved by |
---|---|---|---|---|---|
08/01/13 | Helena Wang | Technical Writer | 1.0 | Initial SO Work Instruction | |
02/17/14 | Ashley Martin | Technical Writer | 1.0 | Review and Format | |
02/28/14 | Elaine Fonaro | Technical Writer | 1.0 | Format for WIKI | |
07/21/20 | Elaine Fonaro | Technical Writer | 1.0 | Updated occurrences of PTS to Traceability | |
09/03/20 | Helena Wang | Technical Writer | 2.0 | Updated EZpicklist section adding the download handload picklist template file. | |
11/01/2021 | Helena Wang | Technicial Writer | 2.0 | Update EZpicklist section add Autocheck PF to Lead Free. |