Difference between revisions of "42Q-MES0085-C Conduit Command Appendix"
(Created page with "<small>Cirrus > Conduit > Conduit Command Appendix</small> <br> 130px|Sanmina logo.png <br> <center>'''Conduit''' </center>...") |
|||
Line 1: | Line 1: | ||
− | + | [[Image:42Q logo.png|130px|Sanmina logo.png]] | |
<br> | <br> | ||
Line 7: | Line 7: | ||
''This edition applies to MES15 Portal 1.0 and all subsequent releases and modifications until otherwise indicated in new revisions.'' | ''This edition applies to MES15 Portal 1.0 and all subsequent releases and modifications until otherwise indicated in new revisions.'' | ||
− | <br> | + | <br> __TOC__ <br> |
= Command Appendix Registry = | = Command Appendix Registry = | ||
Line 19: | Line 19: | ||
The full list of commands and a short explanation of each are given below: | The full list of commands and a short explanation of each are given below: | ||
+ | <br> | ||
− | + | == A == | |
− | == A == | ||
=== AddAttribute === | === AddAttribute === | ||
Line 47: | Line 47: | ||
Add Tracked Component is equivalent to ADCMP3 in SFDC. | Add Tracked Component is equivalent to ADCMP3 in SFDC. | ||
− | === AddUniqueAssemblyComponent === | + | === AddUniqueAssemblyComponent === |
− | Add Unique Assembly Component is the unique component version of the Scanning Template enabled ADCMP command in SFDC. AddUniqueComponent Add Unique Component has no corollary in SFDC today. It is designed to add a unique component without a predefined assembly record just like ADCMP2 (non-tracked) or ADCMP3 (tracked). AddUnitToContainer Add Unit To Container has no equivalent command in SFDC. SFDC Containerization essentially does the same thing via complicated mini-sessions executed after NEWCNTNR / OPENCNTNR. | + | Add Unique Assembly Component is the unique component version of the Scanning Template enabled ADCMP command in SFDC. AddUniqueComponent Add Unique Component has no corollary in SFDC today. It is designed to add a unique component without a predefined assembly record just like ADCMP2 (non-tracked) or ADCMP3 (tracked). AddUnitToContainer Add Unit To Container has no equivalent command in SFDC. SFDC Containerization essentially does the same thing via complicated mini-sessions executed after NEWCNTNR / OPENCNTNR. |
=== AddUnitToLot === | === AddUnitToLot === | ||
Line 59: | Line 59: | ||
Apply Meo is equivalent to ADMEO. | Apply Meo is equivalent to ADMEO. | ||
− | == B == | + | == B == |
− | |||
− | |||
− | == C == | + | == C == |
=== ChangePartNumber === | === ChangePartNumber === | ||
Line 97: | Line 95: | ||
Create Lot creates a lot serial number. Unlike NEWLOT it does not initiate prompting for lot units. It only creates a lot. | Create Lot creates a lot serial number. Unlike NEWLOT it does not initiate prompting for lot units. It only creates a lot. | ||
− | == D == | + | == D == |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | == | + | == E == |
+ | === END === | ||
+ | End is effectively identical to END in SFDC. | ||
− | == | + | == F == |
+ | == G == | ||
+ | == H == | ||
− | == | + | == I == |
+ | == J == | ||
+ | == K == | ||
− | + | == L == | |
− | |||
− | == L == | ||
=== LegacyCustomCommand === | === LegacyCustomCommand === | ||
Line 135: | Line 121: | ||
Should never be executed directly, Conduit understands !!1 and !!2 commands natively and uses this command to structure the executable call. | Should never be executed directly, Conduit understands !!1 and !!2 commands natively and uses this command to structure the executable call. | ||
− | == M == | + | == M == |
=== MOVE === | === MOVE === | ||
Line 141: | Line 127: | ||
Effectively identical to MOVE in SFDC. | Effectively identical to MOVE in SFDC. | ||
− | == N == | + | == N == |
− | + | == O == | |
− | |||
− | == O == | ||
=== OpenContainer === | === OpenContainer === | ||
Line 155: | Line 139: | ||
Changes the status of a lot to Open. Does not initiate lot serial scanning like OPENLOT. | Changes the status of a lot to Open. Does not initiate lot serial scanning like OPENLOT. | ||
− | == P == | + | == P == |
+ | == Q == | ||
− | + | == R == | |
− | |||
− | |||
− | |||
− | |||
− | == R == | ||
=== ReconcileComponentMFGHolds === | === ReconcileComponentMFGHolds === | ||
Line 233: | Line 213: | ||
Replace a preexisting unique component. SplitPanel Effectively equivalent to SPLTP. ViewComponents Equivalent to VWCMP. ViewDefects Effectively equivalent to VWDFC. ViewHistory Effectively equivalent to VWHST. | Replace a preexisting unique component. SplitPanel Effectively equivalent to SPLTP. ViewComponents Equivalent to VWCMP. ViewDefects Effectively equivalent to VWDFC. ViewHistory Effectively equivalent to VWHST. | ||
− | == S | + | == S == |
− | |||
− | |||
− | |||
− | |||
+ | == T == | ||
+ | == U == | ||
− | == | + | == V == |
+ | == W == | ||
+ | == X == | ||
− | == | + | == Y == |
+ | == Z == | ||
− | |||
− | + | == Conduit Command Listing == | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
Every command currently available can be found at the following URL: | Every command currently available can be found at the following URL: | ||
− | [http://p88conduit1:18005/ccr http://p88conduit1:18005/ccr] | + | [http://p88conduit1:18005/ccr http://p88conduit1:18005/ccr] |
− | |||
+ | <br> | ||
Definitions for specific commands can be found at the following URL: | Definitions for specific commands can be found at the following URL: | ||
[http://p88conduit1:18005/ccr/AddComment http://p88conduit1:18005/ccr/AddComment] | [http://p88conduit1:18005/ccr/AddComment http://p88conduit1:18005/ccr/AddComment] |
Revision as of 19:42, 26 January 2017
This edition applies to MES15 Portal 1.0 and all subsequent releases and modifications until otherwise indicated in new revisions.
Contents
- 1 Command Appendix Registry
- 1.1 A
- 1.2 B
- 1.3 C
- 1.4 D
- 1.5 E
- 1.6 F
- 1.7 G
- 1.8 H
- 1.9 I
- 1.10 J
- 1.11 K
- 1.12 L
- 1.13 M
- 1.14 N
- 1.15 O
- 1.16 P
- 1.17 Q
- 1.18 R
- 1.18.1 ReconcileComponentMFGHolds
- 1.18.2 RejectIfMissingAttribute
- 1.18.3 RejectIfMissingAttributes
- 1.18.4 RejectIfMissingProcessAttributes
- 1.18.5 RejectIfMissingComponents
- 1.18.6 RemoveAllComponents
- 1.18.7 RemoveAttribute
- 1.18.8 RemoveComponent
- 1.18.9 RemoveUnitFromContainer
- 1.18.10 RemoveUnitFromLot
- 1.18.11 RepairDefect
- 1.18.12 ReplaceAttribute
- 1.18.13 ReplaceNontrackedAssemblyComponent
- 1.18.14 ReplaceNontrackedComponent
- 1.18.15 ReplaceTrackedAssemblyComponent
- 1.18.16 ReplaceTrackedComponent
- 1.18.17 ReplaceUniqueComponent
- 1.19 S
- 1.20 T
- 1.21 U
- 1.22 V
- 1.23 W
- 1.24 X
- 1.25 Y
- 1.26 Z
- 1.27 Conduit Command Listing
Command Appendix Registry
The commands defined within the Conduit Command Registry represent the core functionality of the Conduit system. Unlike with legacy systems, Conduit commands are full words, generally Pascal case (though technically command names are case insensitive.)
In addition to the more extensive names, Conduit Commands tend to be more focused toward a single concept. Most Conduit commands expect all of their data to be provided up front, leaving the work of gathering that data to the various client implementations in conjunction with the CCRS.
The commands referencing Assembly or Defined components and attribute respectively are designed for use with the Scanning Template mechanism in Conduit. The basic concept is that the actual command to use (tracked, unique, nontracked, etc.) will be provided by Conduit. Individual clients only need to prompt for the appropriate piece of data to satisfy the scan template then construct a Client Command from the Scan Template + user input.
The full list of commands and a short explanation of each are given below:
A
AddAttribute
Add Attribute does not have an equivalent in SFDC. It is effectively the equivalent of ADCMP2 but for an attribute. It allows adding an attribute for which a definition did not already exist.
AddComment
Add Comment is equivalent to ADCOMMENT in SFDC.
AddDefinedAttribute
Add Defined Attribute is equivalent to ATTADD in SFDC. Unlike SFDC it is designed to be used with the Conduit “Scanning Template” construct for units that have active / unreconciled Assembly / Attr_Def entries. AddMeasurementKey Add Measurement Key is equivalent to MEASKEY in SFDC.
AddNontrackedAssemblyComponent
Add Nontracked Assembly Component is a “Scanning Template” specific command for adding a non-tracked component based on an unreconciled assembly record for a unit. It is equivalent to ADCMP
AddNontrackedComponent
Add Nontracked Component is effectively identical to ADCMP2 AddTrackedAssemblyComponent Add Tracked Assembly Component is the tracked version of the Scanning Template enabled ADCMP command in SFDC.
AddTrackedComponent
Add Tracked Component is equivalent to ADCMP3 in SFDC.
AddUniqueAssemblyComponent
Add Unique Assembly Component is the unique component version of the Scanning Template enabled ADCMP command in SFDC. AddUniqueComponent Add Unique Component has no corollary in SFDC today. It is designed to add a unique component without a predefined assembly record just like ADCMP2 (non-tracked) or ADCMP3 (tracked). AddUnitToContainer Add Unit To Container has no equivalent command in SFDC. SFDC Containerization essentially does the same thing via complicated mini-sessions executed after NEWCNTNR / OPENCNTNR.
AddUnitToLot
Add Unit To Lot has no equivalent command in SFDC. SFDC “Lotization” is handled via cumbersome sessions within NEWLOT / OPENLOT.
ApplyMeo
Apply Meo is equivalent to ADMEO.
B
C
ChangePartNumber
Change Part Number is equivalent to CHGPN.
ChangeRevision
Change Revision is equivalent to CHGREV.
ChangeSerialNumber
Change Serial Number is equivalent to CHGID.
ClearMatchingAttributes
Clear Matching Attributes is designed to remove attributes that match a particular input. It is equivalent to CLRATT.L.
ClearNonmatchingAttributes
Clear Non-Matching Attributes is designed to remove attributes that do NOT match a particular input. It is equivalent to CLARATT.R.
CloseContainer
Close Container is equivalent to CLOSECNTNR. CloseLot Close Lot is equivalent to CLOSELOT.
CreateContainer
Create Container creates a container serial number. Unlike NEWCNTNR it does not immediately initiate prompting for container units. It only creates a container.
CreateLot
Create Lot creates a lot serial number. Unlike NEWLOT it does not initiate prompting for lot units. It only creates a lot.
D
E
END
End is effectively identical to END in SFDC.
F
G
H
I
J
K
L
LegacyCustomCommand
Should never be executed directly, Conduit understands !!1 and !!2 commands natively and uses this command to structure the executable call.
M
MOVE
Effectively identical to MOVE in SFDC.
N
O
OpenContainer
Changes the status of a container to Open. Does not initiate container serial scanning like OPENCNTR.
OpenLot
Changes the status of a lot to Open. Does not initiate lot serial scanning like OPENLOT.
P
Q
R
ReconcileComponentMFGHolds
Traverses the entire component tree and checks to see if a component serial is on hold. RecordDefect Records a defect against a unit. Equivalent to RCDFC in SFDC.
RejectIfMissingAttribute
Fails a unit that is missing the provided attribute. Equivalent to VERATT.LIST.
RejectIfMissingAttributes
Fails a unit that is missing any configured attributes. Equivalent to VERATT.ALL.
RejectIfMissingProcessAttributes
Fails a unit that is missing any attributes matching the current scanning location’s process. Effectively equivalent to VERATT.PROC.
RejectIfMissingComponents
Fails a unit that is missing any assembly components. Unlike VERCMP this command has to be provided with a failure location just like Reject if Missing Attribute[s] (VERATT).
RemoveAllComponents
Removes all components from a unit. Equivalent to RMCMPALL.
RemoveAttribute
Removes an attribute. Similar to ATTREMOVE but the specific attribute must be provided.
RemoveComponent
Removes a component. Similar to RMCMP2.
RemoveUnitFromContainer
Removes a unit from a container. Equivalent to RMVFRMCNTNR.
RemoveUnitFromLot
Removes a unit from a lot. Equivalent to RMVFRMLOT.
RepairDefect
Repair a defect on a unit. Similar to RCRPR but the defect sequence to be repaired must be provided.
ReplaceAttribute
Replace an existing attribute with a new attribute.
ReplaceNontrackedAssemblyComponent
Replace a previously existing “Scanning Template” non-tracked component with a new one.
ReplaceNontrackedComponent
Replace a previously existing non-tracked component; equivalent to RPCMP2.
ReplaceTrackedAssemblyComponent
Replace a preexisting “Scanning Template” tracked component with a new one.
ReplaceTrackedComponent
Replace a previously existing tracked component, effectively equivalent to RPCMP2.
ReplaceUniqueComponent
Replace a preexisting unique component. SplitPanel Effectively equivalent to SPLTP. ViewComponents Equivalent to VWCMP. ViewDefects Effectively equivalent to VWDFC. ViewHistory Effectively equivalent to VWHST.
S
T
U
V
W
X
Y
Z
Conduit Command Listing
Every command currently available can be found at the following URL:
Definitions for specific commands can be found at the following URL: