Difference between revisions of "SOP-42Q-MES0009 Mfg Line Maintenance"

From 42Q
Jump to navigation Jump to search
Line 223: Line 223:
 
the username is the siteminder username (or a partial string)
 
the username is the siteminder username (or a partial string)
  
==Document Revision History==
+
== Document Revision History ==
 
 
{|border="2" cellspacing="0" cellpadding="4" width="100%"
 
|align = "center" bgcolor = "#00FFFF"|<font color="#FFFFFF">Date</font>
 
|align = "center" bgcolor = "#00FFFF"|<font color="#FFFFFF">Author</font>
 
|align = "center" bgcolor = "#00FFFF"|<font color="#FFFFFF">Title</font>
 
|align = "center" bgcolor = "#00FFFF"|<font color="#FFFFFF">Version</font>
 
|align = "center" bgcolor = "#00FFFF"|<font color="#FFFFFF">Change Reference</font>
 
  
 +
{| width="100%" cellspacing="0" cellpadding="4" border="2"
 +
|-
 +
| bgcolor="#00FFFF" align="center" | <font color="#FFFFFF">Date</font>
 +
| bgcolor="#00FFFF" align="center" | <font color="#FFFFFF">Author</font>
 +
| bgcolor="#00FFFF" align="center" | <font color="#FFFFFF">Title</font>
 +
| bgcolor="#00FFFF" align="center" | <font color="#FFFFFF">Version</font>
 +
| bgcolor="#00FFFF" align="center" | <font color="#FFFFFF">Change Reference</font>
 
|-
 
|-
|08/16/13
+
| 08/16/13  
|Elaine Fonaro  
+
| Elaine Fonaro  
|Technical Writer
+
| Technical Writer  
|v 1.0  
+
| v 1.0  
|This is the first revision of MDS User<nowiki>’</nowiki>s Guide
+
| This is the first revision of MDS User<nowiki>’</nowiki>s Guide
 
 
 
|-
 
|-
|02/10/14
+
| 02/10/14  
|Ashley Martin
+
| Dane Parker
|Technical Writer
+
| Technical Writer  
|v 1.0
+
| v 1.0  
|Grammar and images review
+
| Grammar and images review
 
 
 
|-
 
|-
|02/12/14
+
| 02/12/14  
|Elaine Fonaro
+
| Elaine Fonaro  
|Technical Writer
+
| Technical Writer  
|v 1.0
+
| v 1.0  
|Formatting
+
| Formatting
 
 
 
|}
 
|}
  
[[category:uncategorized]]
+
[[Category:Uncategorized]]

Revision as of 21:46, 17 February 2014

Sanmina logo.png


SFDC Configuration
Mfg Line Maintenance
Version MES15 Portal 1.0
Work Instruction


This Work Instruction is Sanmina's corporate standard.
This document is under revision control. The latest revision is located on SanminaNet.
Once printed it is an uncontrolled copy. All alterations to this work instruction require approval.
Contact the IT Global Education and Training Department to submit suggested alterations and or updates.

This edition applies to MES15 Portal 1.0 Application and all subsequent releases and modifications until otherwise indicated in new revisions.


SFDC Configuration

The Shop Floor Data Collection System (SFDC) communicates interactively with the Customer Order Processing System (COPS), and Statistical Process Control/Statistical Quality Control (SPC/SQC). The Manufacturing Data System (MDS) makes the communication between these systems possible.

SFDC provides real-time information used by SPC/SQC and MESWeb to create quality control reports. The data configuration for SFDC PC is handled within the Manufacturing Data System (MDS), which is a complete factory automation system. The SFDC System uses barcode scanning, both manual and automated, to monitor and control a single product line or an entire plant. SFDC Configuration collects data, provides analysis, maintains unit histories, and controls product movement on the manufacturing floor.

The system provides Access Control between the modules of the application, including the portlets of each screen. The current version has an SFDC Configuration page which provides access to all sub modules pages and its functions (view, add, edit, delete, print and generate output file.

Set up SFDC Configuration

1. To access the SFDC Configuration, select SFDC Configuration in the menu. The main SFDC Configuration and sub modules page is displayed:


Figure 1: MDS Portal – SFDC Configuration Sub modules

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 01.jpg

NOTE: A user only has access to the modules assigned to his/her profile.

Mfg Line Maintenance

This portlet enables the user to assign data collector locations to a manufacturing line for use with the SOMS system.

Add Mfg Lines

This portlet enables the user to add manufacturing line configurations to the database.

1. To add manufacturing lines, click the Add icon. The Mfg Line Form is displayed.

Figure 2: Mfg Line Form

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 02.jpg

To add or edit a manufacturing line,

1. Enter the Name and the Site ID in the respective fields. If it is a WIP Location Line, at least one location must be assigned. Otherwise, the Pixel X and the Pixel Y, and at least one scanner must be assigned.

The name must be created according the following rules:

  • 2 chars for Level or Modules (areas of interests) - Ex: L1; M2
  • 2 chars to group Process Lines - Ex: L110; M250
  • 1 char with "_" + Process Name + 1 char with "_" - Ex: L110_SMT_; M250_PTH_
  • Line name - Ex: L110_SMT_Line1; M250_PTH_Line2.

NOTE: If the manufacturing line is WIP location line, the name must end with "WIP".

NOTE: The Site ID can be changed if all Site ID references were updated in the SFDC Miscellaneous Configuration sub-module. If it is a WIP location line, it is not possible to create an escalation for this manufacturing line.

Man Power, Work Hour, Min Sample Size, fields are going to be enabled only after the user selects enters the mandatory Mfg Line Form fields.

NOTE: The Man Power and Work Hour fields will be used in the MES Web reports.

Adding Escalation E-mails:

Add Escalation e-mails by

1. Entering an email address and selecting the Add icon. The escalation emails allow adding four levels of emails. Level 2, Level 3, and Level 4 tabs become available only when the information in the previous tab has an email addressed assigned to it.

Figure 3: Escalation

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 03.jpg

Using the available filters:

Scanners can be filtered by Shop Floor ID, Device Number, or Location Name using the Available Scanners field under the Associated Scanners tab:

  • To filter by location, enter the Location name. (e.g., S076).
  • To filter by Shop Floor ID, enter the shop floor ID (e.g., p99dcuat1).
  • To filter by Device, enter the Device number (e.g., 76).

Adding or Removing scanners:

Figure 4: Add/Remove Scanners

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 04.jpg

To add a scanner,

1. Select it from Available Scanners in the drop-down list.

To remove a specific one,

1. Select the desired scanner, select Remove Selected Item.

To remove all items,

1. Select Remove All Items.

2. Select Ok to save, or Cancel to cancel the operation.

NOTE: The Location Tab allows the setup of manufacturing lines by locations, instead of scanners.

Edit Mfg Lines

This portlet enables the user to edit manufacturing line configurations. The steps for editing manufacturing lines are the same as those for adding. For further information, see the Add Mfg Line section above.

To edit manufacturing lines,

1. Select the desired line and select Edit.

Figure 5: Mfg Line List – Edit

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 05.jpg

2. Update the information in the Mfg Line Form as needed.

3. Select Ok to confirm, or select No to cancel the update action.

Delete Mfg Lines

This portlet enables the user to delete an existing manufacturing line configuration. It is only possible to delete a manufacturing line if it does not have any Data Collector locations assigned to it. The user must first remove all assigned Data Collector locations from the manufacturing line configuration prior to deleting.

To delete a manufacturing line,

1. Select the desired manufacturing line, then select Delete. A confirmation message is displayed.

Figure 6: Mfg Line List - Delete

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 06.jpg

2. Select Yes to confirm, or No to cancel the action.

Print/Export Filtered Mfg Lines

This portlet enables the user to print/export filtered manufacturing lines.

To print filtered Mfg Lines,

1. Select Print/Export Filtered Mfg Lines. A report is generated and the user is able to save the file or print it.

Figure 7: Print/Export Filtered Mfg Line

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 07.jpg

Figure 8: Print/Export Filtered Mfg Lines Result

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 08.jpg

Import Escalation Data

To import escalation data, select Import Escalation Data.

Figure 9: Import Escalation Data

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 09.jpg

Choose the CVS file and save it.

The CVS file has the following format:

SITE (String), LINE (Mfg Line name defined on precondition 2), x (Always empty), y (Always empty), x Pixels (Integer), y Pixels (Integer), Escalation 1, Escalation 2, Escalation 3 and Escalation 4 - see example below (figure 11):

E43_HO,M110_SMT_Line_1,,,100,200,e-mail;email;-1-3-30,e-mail;-4-5-30,e-mail;-6-10-30,e-mail;-10-15-30

E43_HO,M200_ICT_Line_1,,,100,200,e-mail;email;-1-3-30,e-mail;-4-5-30,e-mail;-6-10-30,e-mail;-10-15-30

NOTE: CSV file format is the same currently in use by plants to maintaining SOMS Escalation and map coordinates.

Export Escalation Data

This portlet will export all escalation Data and save it in a ZIP file.

1. Choose the local directory and select Save. The ZIP file with the CSV file will be saved locally.

Figure 10: Export Escalation Data

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 10.jpg

Figure 11: CSV File Generated.

SOP-5-I-MDS0037-C RA1 MDS Mfg Line Maintenance 11.jpg

Appendix

Glossary

Access Control

it is a module that will set the permissions for users and external customers of Sanmina

administrator

the System Administration has full access - all plants, all reports, all users.

component

A component is a specific piece of data that appears on a label, for example: bar code, part numbers, graphic images, line or text. Hence, label components are broken down into several different types: text, graphic images, MDS database values, or a combination of text and database values.

framework

In software development, a framework is a defined support structure in which another software project can be organized and developed. A framework may include support programs, code libraries, a scripting language, or other software to help develop and glue together the different components of a software project.

SFDC Configuration

The rules used to define how SFDC collects data, provides analysis, controls processing and maintains unit histories

Site Minder

Universal login of Sanmina

username

the username is the siteminder username (or a partial string)

Document Revision History

Date Author Title Version Change Reference
08/16/13 Elaine Fonaro Technical Writer v 1.0 This is the first revision of MDS User’s Guide
02/10/14 Dane Parker Technical Writer v 1.0 Grammar and images review
02/12/14 Elaine Fonaro Technical Writer v 1.0 Formatting