Difference between revisions of "SOP-42Q-MES0069 Statistical Process Control"

From 42Q
Jump to navigation Jump to search
 
(337 intermediate revisions by 7 users not shown)
Line 3: Line 3:
  
 
 
 
 
 
[[File:42Q Logo.jpg|RTENOTITLE]]
 
  
 
 
 
 
  
 
 
 
 
<center>'''Quality'''</center> <center>'''Statistical Process Control'''</center> <center>'''Version MES15 Portal 1.0'''</center> <center>'''Work Instruction'''</center>
+
<center>'''Quality'''</center> <center>'''Statistical Process Control'''</center> <center>'''Version MES 15.82'''</center> <center>'''Revision O1'''</center> <center>&nbsp;</center>  
&nbsp;
 
<center>This Work Instruction is 42Q's corporate standard.</center> <center>&nbsp;This document is under revision control. The latest revision is located on Intranet.</center> <center>&nbsp;Once printed it is an uncontrolled copy. All alterations to this work instruction require approval.</center> <center>&nbsp;Contact the IT Global Education and Training Department to submit suggested alterations and or updates.</center>
 
''This edition applies to MES15 Portal 1.0 and all subsequent releases and modifications until otherwise indicated in new revisions.''
 
 
 
 
&nbsp;
 
&nbsp;
 
+
<center>&nbsp;</center> <center>&nbsp;</center>
 
&nbsp;
 
&nbsp;
  
 
&nbsp;
 
&nbsp;
  
= <span class="mw-headline" id="Notification"><span class="mw-headline" id="Notification"><span class="mw-headline" id="Notification"><span class="mw-headline" id="Notification"><span class="mw-headline" id="Notification">Notification</span></span></span></span></span> =
+
= <span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction">Introduction</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
 
 
CDC SPC team is dedicated to the development of new functions and bug fixes to provide our users with a more perfect SPC system. New versions will be periodically released.
 
 
 
This user manual is based on '''MES 15 Quality SPC 1.2.28'''&nbsp;This manual does not apply to older or newer versions of SPC.&nbsp;
 
  
 
&nbsp;
 
&nbsp;
  
= <span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction"><span class="mw-headline" id="Introduction">Introduction</span></span></span></span> =
+
'''Statistical Process Control (SPC)''' is an industry-standard methodology for measuring and controlling quality during the manufacturing process. It is a method used for monitoring, controlling, and, ideally, improving a process through statistical analysis.
 
 
SPC is an industry-standard methodology for measuring and controlling quality during the manufacturing process. It is a method for monitoring, controlling, and, ideally, improving a process through statistical analysis.
 
  
Based on statistical theories, SPC (Statistical Process Control) is applied to Sanmina’s manufacturing and production line for the purpose of quality control. SPC enables users to continuously monitor, analyze, and control the production process in real-time to reduce possible waste and improve process capability. Key tools used in SPC include control charts, monitor maintenance, email notifications, system configuration, line stoppage, etc. On the client-side, the SPC system includes two components: SPC portlet and SPC TV portlet.&nbsp;
+
Based on statistical theories, SPC (Statistical Process Control) is applied to manufacturing and production lines for the purpose of quality control. SPC enables users to continuously monitor, analyze, and control the production process in real-time to reduce possible waste and improve process capability. Key tools used in SPC include control charts, monitor maintenance, email notifications, system configuration, line stoppage, etc. On the client side, the SPC system includes three components: '''SPC Portlet, SPC TV Portlet, and SPC Dashboard Portlet.&nbsp;'''
  
 
Using the SPC, the Company can Dramatically reduce variability and scrap, statistically improve productivity, reduce costs, uncover hidden process characteristics, instantly react to process changes, and make real-time decisions on the shop floor.
 
Using the SPC, the Company can Dramatically reduce variability and scrap, statistically improve productivity, reduce costs, uncover hidden process characteristics, instantly react to process changes, and make real-time decisions on the shop floor.
  
See below the main features for SPC:
+
See below the main features of SPC:
  
*Monitors can be easily “Stopped” & “Started”;
+
*Support BATCH units calculation for Yield and Pareto charts.
*Support BATCH units calculation for Yield and Pareto charts;
+
*Display Affected Serials for all charts displayed.
*Display Affected Serials for all charts displayed;
+
*Change chart background color for Out-of-Control conditions.
*Change chart background color for Out-of-Control condition;
+
*Email Notifications are sent to specific recipients for Out-of-Control conditions.
*E-mail Notification send to specified recipients for Out-of-Control condition;
+
*Ability to export DPMO reports.
*Ability to export DPMO report;
+
*Control on production process route (MFG hold) based on Pareto chart, P chart, NP chart, C chart, U chart, FPY chart, Xbar-R Chart, and I-MR Chart.
*Control on production process route (MFG hold) base on Pareto chart;&nbsp;
+
*SPC Dashboard displays multiple monitors on TV in real time.
*SPC Dashboard displays multiple monitors on TV in real-time;
+
*Support multiple data collection strategies: Automatic Collection data from MDS or MESWeb, Manual Collection data via SPC UI, and Automatic Collection data via SPC API.
  
 
&nbsp;
 
&nbsp;
  
SPC also provides some charts that help to see graphically some statistics:&nbsp;
+
&nbsp; SPC also provides some charts that help to see graphically some statistics:&nbsp;
 +
 
 +
#'''Attribute Control Charts '''– Process CONTROL (defects and defective units):
  
#'''Attribute Control Charts – Process CONTROL (defects and defective units)'''
+
*Monitors Grouping data by Piece: P and NP charts.
 +
*Monitors Grouping data by Defect Points: C and U charts.
 +
*Monitors by BATCH: Yield (pie) and Pareto charts.
 +
*Others: FPY and DPMO (DPMO, DPMO-P, DPMO-A, DPMO-T, DPMO-C) charts.
  
*Monitors Grouping data by Piece: P and NP charts
+
&nbsp;
*Monitors Grouping data by Defect Points: C and U charts
 
*Monitors by BATCH: Yield (pie) and Pareto charts
 
*Others: FPY and DPMO (DPMO, DPMO-P, DPMO-A, DPMO-T, DPMO-C) charts
 
 
<ol start="2">
 
<ol start="2">
<li>'''Variables Control Charts – Process CAPABILITY control (SFDC attribute values)'''</li>
+
<li>'''Variables Control Charts – '''Process CAPABILITY control (attribute values)</li>
 
</ol>
 
</ol>
  
If the combination of Monitor setup (Part Number + Process/Workstation) has attribute setup on SFDC (Attribute Maintenance) the attribute charts will be displayed on Monitor Maintenance screen with: X-Bar/R chart; I/MR chart; Cpk/Ppk
+
If the combination of Monitor setup (Part Number + Process/Workstation) has attribute setup on '''Shop Floor Configuration''' (Attribute Maintenance) the attribute charts will be displayed on the Monitor Maintenance screen with&nbsp;'''X-Bar/R chart; I/MR chart; Cpk/Ppk.'''
  
To get more information, see the next topics of this document.
+
To get more information, see the next topics of this document. &nbsp;
  
 
&nbsp;
 
&nbsp;
  
= <span class="mw-headline" id="Server_Information_Configuration"><span class="mw-headline" id="Server_Information_Configuration"><span class="mw-headline" id="Server_Information_Configuration"><span class="mw-headline" id="Server_Information_Configuration">Server Information Configuration</span></span></span></span> =
+
== <span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration"><span class="mw-headline" id="Pre_Configuration">Pre Configuration</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
 
 
After SPC deployed to your web server, you need to set up a server and configure the server information from the Server Information page.
 
  
To access the Server Information page in the MES Portal, navigate to '''Administration > Server Information'''.
+
=== <span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information"><span class="mw-headline" id="Server_Information">Server Information</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
'''Figure 1: Server Information Page'''
+
After SPC is deployed to the users' web server, users&nbsp;need to set up a server and configure the server information from the '''Server Information''' page.
  
[[File:SOP-5-I-MES0069-C Server Information Page.jpg|RTENOTITLE]]
+
To access the Server Information page in the MES Portal, navigate to:&nbsp;'''Administration > Server Information'''.
  
 
&nbsp;
 
&nbsp;
  
 +
==== <span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server">Create SPC Server&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
== <span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server"><span class="mw-headline" id="Create_SPC_Server">Create SPC Server</span></span></span></span></span></span></span> ==
+
To create an SPC server:
  
To create an SPC server :
+
#Select '''Add''' from the Server Information page.  
 
+
#Select '''SPC''' from the '''Program''' drop-down box.&nbsp;
#Select '''Add '''from the Server Information page.  
+
#Complete all the fields and select '''Add''' to save the configuration to the database.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 2: Add SPC&nbsp;Server'''
+
'''Figure 1: Add SPC Server'''
  
[[File:SOP-5-I-MES0069-C Add SPC Server.jpg|RTENOTITLE]]
+
[[File:SPC AddSPCServer.png|700px|SPC AddSPCServer.png]]
<ol start="2">
 
<li>&nbsp;In the Add Server Information page, select SPC from the '''Program '''drop-down box.</li>
 
<li>Complete all the fields and select '''Add '''to save the configuration to the database.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 3:Add Server Information'''
+
Fields, as seen in the above screenshot, are explained in the following:
 
 
[[File:Add Server Information Fields.png|Add Server Information Fields]]
 
 
 
<br/> Fields as seen in the above screenshot are explained in the following:
 
  
 
'''Name''': The&nbsp;name of the SPC server.
 
'''Name''': The&nbsp;name of the SPC server.
  
'''IP''': The SPC server IP address.
+
'''Host''': The SPC server IP address.
  
'''AppServer Port''': The port that SPC server deploys within&nbsp;Tomcat server.
+
'''AppServer Port''': The port that the SPC server deploys within the Tomcat server.
  
'''Context Path:''' The patch that SPC server deployed on Tomcat server. After the system is refactored, the system should have only one program that supports all sites/plants&nbsp;so the context path of server information for each site/plant should be /spc-server.
+
'''Context Path:''' The patch that the SPC server deployed on the Tomcat server. After the system is refactored, the system should have only one program that supports all sites/plants&nbsp;so the context path of server information for each site/plant should be /SPC-server.
  
'''Status''': After you have completed all the field above, select a status from this drop-down box, and click the check button to verify that the SPC server connection is working.
+
'''Token''': Safe Palindrome authentication to call the API. This is used to connect to the services for collecting data via SPC API.
  
&nbsp;
+
'''Key''': Safe Palindrome authentication to call the API. This is used to connect to the services for collecting data via SPC API.
  
 +
'''Status''': After you have completed all the fields above, select a status from this drop-down box, and click the check button to verify that the SPC server connection is working.
  
== <span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server">Edit SPC Server</span></span></span></span></span></span></span></span> ==
+
'''<u>Note:</u> '''This configuration can be Edited and or Deleted at any time.
  
To edit an existing server :
+
&nbsp;
  
#From the Server Information page, check the box of a server and click '''Edit.'''
+
&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 4:&nbsp;Edit Server Information'''
+
= <span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="SPC"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server"><span class="mw-headline" id="Edit_SPC_Server">SPC&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
  
[[File:SOP-5-I-MES0069-C Edit Server Information.jpg|RTENOTITLE]]
+
== <span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance">Monitor Group Maintenance</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
 +
 
 +
'''MES 15 Quality SPC&nbsp;'''uses the Monitor Group to maintain the SPC monitors that collect data from different sources. However, MES 15 Quality SPC does not actually collect data from SPI, it collects data from the SFDC archive as an associated database schema and support is not fully ready yet. The Dot Line Source was added in Monitor Group Maintenance to support the Dot Line chart, and the difference between the Dot Line chart and other charts is that the user transmits the data to the SPC through an API, and this data has been calculated, and the SPC directly uses the data for display.
  
 
&nbsp;
 
&nbsp;
<ol start="2">
 
<li>In the Edit Server Information page, update the values of any field as needed.</li>
 
<li>Select&nbsp;'''Save '''to save the updates to the database; otherwise, click the '''Cancel '''button if you want to quit the action without saving changes to the server.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 5: Edit Server Information Fields'''
 
  
[[File:SPC Figure5 EditServerInfoFields.png|700px|File:SPC Figure5 EditServerInfoFields.png]]
 
  
<span class="mw-headline" id=""><span class="mw-headline" id="">&nbsp;</span></span>
+
== <span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group">View Monitor Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
 +
To view&nbsp;existing'''&nbsp;'''monitor groups:
  
== <span class="mw-headline" id="Delete_SPC_Server"><span class="mw-headline" id="Delete_SPC_Server"><span class="mw-headline" id="Delete_SPC_Server"><span class="mw-headline" id="Delete_SPC_Server"><span class="mw-headline" id="Delete_SPC_Server">Delete SPC Server</span></span></span></span></span> ==
+
Navigate'''&nbsp;'''to''':''' '''Quality > SPC'''.&nbsp;
  
To delete an existing server :
+
Once an SPC engine has been selected, the existing monitor groups that were created under the selected SPC engine will be displayed on the Monitor Group List page.'''&nbsp;'''
 
 
#Select the server and click '''Delete '''in the toolbar.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 6: Delete Server'''
+
'''Figure 2: Monitor Group List'''
  
[[File:SOP-5-I-MES0069-C Delete Server.jpg|RTENOTITLE]]
+
[[File:SPC MonitorGroupListp.png|900px|SPC MonitorGroupListp.png]]
 
 
&nbsp;
 
  
== <span class="mw-headline" id="View_Existing_SPC_Server"><span class="mw-headline" id="View_Existing_SPC_Server"><span class="mw-headline" id="View_Existing_SPC_Server"><span class="mw-headline" id="View_Existing_SPC_Server">View Existing SPC Server</span></span></span></span> ==
 
  
On SPC portlet Server List page, you can view all existing SPC servers created in MES Portal Server Information portlet. In addition, users can choose a server and click Go to enter the server for further manipulation.
+
== <span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group">Create Monitor Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;
+
Every monitor is created under a monitor group. So before creating a monitor, a monitor group must be created first. To create a monitor group:
  
'''Figure 7:&nbsp;Existing Server List'''
+
From the SPC Monitor Group List page, select the [[File:Add-new-icon.png|RTENOTITLE]] button in the toolbar. SPC opens the Add Monitor Group page.
  
[[File:SOP-5-I-MES0069-C Existing Server List.jpg|RTENOTITLE]]
+
#Enter the monitor group name in the Name field.
 +
#Select '''MDS''', '''SPI''', or '''DotLine''' '''Source''' from the '''Data Source Type''' drop-down box.
 +
#If you need to send an '''MFG Hold''' to stop the production line, you can enable the '''Send MFG Hold request to the checkbox.'''
 +
#Enter a&nbsp;'''Shop Floor ID''', &nbsp;and '''Description'''.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
= <span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance"><span class="mw-headline" id="Monitor_Group_Maintenance">Monitor Group Maintenance</span></span></span></span></span></span> =
+
'''Figure 3: New Monitor Group Page-MDS'''
  
'''MES 15 Quality SPC 1.2.28 '''uses the Monitor Group to maintain SPC monitors that collect data from different sources, such as DotLine Source,&nbsp; SFDC Archive (MDS), and SPI. However, MES 15 Quality SPC does not actually collect data from SPI, it collects data from the SFDC archive as an associated database schema and support is not fully ready yet. The Dot Line Source was added in Monitor Group Maintenance to support the Dot Line chart and the difference between the Dot Line chart and other charts is that the user transmits the data to the SPC through an API and this data has been calculated, and the SPC directly uses the data for display.
+
'''[[File:SPC NewMonitorGroupPage-MDS.png|900px|SPC NewMonitorGroupPage-MDS.png]]'''
  
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group"><span class="mw-headline" id="View_Monitor_Group">View Monitor Group</span></span></span></span></span></span></span></span></span></span> ==
+
'''<u>Note:</u> '''The SPC program is deployed on the Amazon cloud server (in the USA). Users scan Serial Numbers on their local PC. So there will be a time zone difference between the SPC server and MDS if they are not in the same time zone.
  
To view existing monitor groups
+
SPC uses the value of this field to calculate the timezone of local MDS, compares it with the Amazon cloud server time zone, calculates the time offset, and determines the right time for the SPC monitor to retrieve data (create time + time offset) so that the scanned SNs data can display on monitor charts.&nbsp;
  
#In the MES portal, navigate to '''Quality > SPC'''. The SPC Welcome page is displayed.&nbsp;Select '''Enter'''.  
+
The&nbsp;'''time zone '''is defined in the '''Plant Maintenance '''module by the administrator.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 8: SPC Welcome Page'''
+
'''Figure 4: New Monitor Group Page - SPI'''
  
[[File:SPC Figure8 SPCWelcomePage.png|700px|SPC Figure8 SPCWelcomePage.png]]
+
[[File:SPC NewMonitorGroupPAge-SPI.png|900px|SPC NewMonitorGroupPAge-SPI.png]]
  
 
&nbsp;
 
&nbsp;
<ol start="2">
 
<li><span style="line-height: 1.5em;">In the Monitor Group List page, select an SPC engine from the drop-down box. By default, the first SPC engine will be selected.</span></li>
 
<li><span style="line-height: 1.5em;">Once an SPC engine has been selected, the existing monitor groups that were created under the selected SPC engine will be displayed on the Monitor Group List page.</span></li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 9: Monitor Group List'''
+
'''Figure 5: New Monitor Group Page - DotLine Source'''
  
[[File:MG list 1.1.png|700px|MG list 1.1.png]]
+
[[File:SPC NewMonitorGroupPage-DotLineSource.png|900px|SPC NewMonitorGroupPage-DotLineSource.png]]
  
&nbsp;
+
<u>'''Note:'''</u> Since some data is manually collected by users, and this kind of data could not be extracted from 42Q, this data has been calculated, and an API was provided to collect the data and present it to users in the&nbsp;'''Dot Line Chart.'''
  
&nbsp;
+
See below some rules to get the&nbsp;'''DotLine Chart:''' &nbsp;
  
=== <span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group"><span class="mw-headline" id="Create_Monitor_Group">Create Monitor Group</span></span></span></span></span></span></span></span></span></span></span></span> ===
+
#First users need to create a new monitor with the below info specified:
  
In '''MES 15 Quality SPC 1.2.28''', every monitor is created under a monitor group. So before creating a monitor, a monitor group must be created first.To create a monitor group:
+
&nbsp;Specify which process parts will be used for this monitor to collect data.
  
#From the SPC Monitor Group List page select the [[File:Add-new-icon.png|RTENOTITLE]] button in the toolbar.  
+
&nbsp;
 +
<ol start="2">
 +
<li>&nbsp;Select Chart Type: '''Dot Line.'''</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
  
'''Figure 10: Creating a New Monitor Group'''
+
When the Dot Line Chart is selected,&nbsp; the '''Application & Data Column''' is enabled to let users select which Application & Data Column will be used to display this chart.
  
[[File:SPC Creating a New Monitor Group.png|700px|SPC_Creating a New Monitor Group]]
+
*Group By: Disabled.
 +
*Interval: Disabled.
 +
*Rules & Actions: Enable.  
  
SPC opens the Add Monitor Group page.
+
&nbsp;
<ol start="2">
+
<ol start="3">
<li>Enter the monitor group name in the Name field</li>
+
<li>Select&nbsp;'''GO '''on the new monitor from the Monitor Group List.</li>
 
</ol>
 
</ol>
  
 
&nbsp;
 
&nbsp;
  
'''Figure 11: Add Monitor Group'''
+
'''Figure 6: Go to New Monitor Group List'''
  
[[File:SPC Add Monitor Group.png|700px|SPC_Add Monitor Group]]
+
'''[[File:SPC GotoNEwMonitorGroupList.png|900px|SPC GotoNEwMonitorGroupList.png]]'''
 
<ol start="3">
 
<ol start="3">
<li>Select MDS, SPI or DotLine Source from the '''Data Source Type''' drop-down box;</li>
+
<li>Select&nbsp;'''NEW'''</li>
<li>Enter a&nbsp;'''Shop Floor ID''', '''Shop Floor''' '''Time Zone''', and '''IP''' (MDS).&nbsp;</li>
+
<li>External Program will periodically pick data from '''Source Record''' by a certain frequency, and put it into SPC by publishing it;</li>
 
</ol>
 
</ol>
  
 
&nbsp;
 
&nbsp;
  
'''Figure 12: Selecting Data Source Type'''
+
&nbsp; '''API interface'''
 +
<ol start="6">
 +
<li>SPC TV will select Monitor to display.&nbsp;</li>
 +
<li>Draw Chart: just like the current u/p chart done in SPC.</li>
 +
</ol>
  
[[File:SPC Selecting Data Source Type.png|700px|SPC_Selecting Data Source Type]]
+
'''X-axis''': Time collected (Import Datetime), Format: MMDDmm
  
'''Figure 13:&nbsp;New Monitor Group Page - MDS'''
+
'''Y-axis:''' Data, UCL (Upper Control Limit), LCL( Lower Control Limit), Target
  
[[File:SPC New Monitor Group Page - MDS.png|700px|SPC_New Monitor Group Page - MDS]]
+
&nbsp;
 +
 
 +
'''Figure 7: New Monitor DotLine Chart Available Charts Tab'''
 +
 
 +
'''[[File:SPC AvailableChartsTab.png|700px|SPC AvailableChartsTab.png]]'''
  
 
&nbsp;
 
&nbsp;
<ol start="5">
 
<li>If you need to send '''MFG Hold '''to stop the production line, you can enable the Send MFG Hold request to the checkbox.</li>
 
</ol>
 
  
Some of the fields in the above figures are explained as follows:&nbsp;
+
'''Select Data i'''n the Drop Down List, and select both:&nbsp;'''Data1 and Data2 '''at the same time.
  
'''Shop Floor ID''': Defines which SFDC that SPC should collect data from.&nbsp;
+
'''<u>Note:</u>'''&nbsp;'''Data1''' or '''Data2''' can be understood as a group of data. Users can choose to display the two groups of data together in the dot line chart, or just display one group of data.
  
'''Shop Floor Time Zone''': The time zone of the selected SFDC PC.&nbsp;
+
And finally, users can select the following actions:
  
'''IP''': Text field for the user to input the SFDC IP address to which MFG hold sends.&nbsp;
+
*'''Send an alert email: '''This action sends an alert email to a specific person. Users can specify who would receive these alert emails in the Email Maintenance&nbsp;module.&nbsp;  
 +
*'''Change the background color to red: '''If the exception was triggered, the background of an associated data record in this monitor will turn red.
  
 
&nbsp;
 
&nbsp;
  
'''Note:''' Beginning with version 1.2.25, SPC program is deployed on the Amazon cloud server (in the USA). Users scan SNs on their local SFDC PC. So there will be a time zone difference between the SPC server and SFDC if they are not in the same time zone. SPC uses the value of this field to calculate the timezone of local SFDC, compares it with the Amazon cloud server time zone, calculates the time offset, and determines the right time for SPC monitor to retrieve data (create time + time offset) so that the scanned SNs data can display on monitor charts.&nbsp;
+
'''Figure 8: New Monitor DotLine Chart Actions Tab'''
  
'''Send MFG Hold request to:''' This checkbox is not selected by default. It is optional. Users wanting SPC to send MFG Hold to stop the manufacturing line must check the Send MFG Hold to request to box and select one of the two radio buttons: '''MDS,''' '''SFDC'''. If MDS is selected, the MFG hold will be sent to MDS and then MDS sends MFG hold to local SFDCs.&nbsp;
+
'''[[File:SPC ActionsTab.png|700px|SPC ActionsTab.png]]'''
  
Next, users will need to input the '''MDS URL''' which enables SPC to send the MFG hold to the right MDS service. Click the [[File:SPC test icon.png|SPC_test icon]] to test the web service connection.
+
== <span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group">Edit Monitor Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;
+
To edit a monitor group:
  
'''Figure 14: MDS URL Input'''
+
#From the '''Monitor Group List page''', check the box of a monitor group that users&nbsp;need to edit, and select '''Edit'''. The Edit Monitor Group page will&nbsp;display.
 +
#Edit any field as needed, and select '''Save''' to keep the change, or '''Cancel '''to abort.
  
[[File:SPC MDS URL Input.png|700px|SPC_MDS URL Input]]
+
'''Figure 9: Edit Monitor Group Fields'''
  
If MDS is selected, the SPC will directly send MFG hold to MDS. Also, users must enter the MDS web service URL in the text field.&nbsp;
+
[[File:SPC EditMonitorGroupFields .png|900px|SPC EditMonitorGroupFields .png]]
  
&nbsp;
+
== <span class="mw-headline" id="Filter_Monitor_Group"><span class="mw-headline" id="Filter_Monitor_Group"><span class="mw-headline" id="Filter_Monitor_Group"><span class="mw-headline" id="Filter_Monitor_Group">Filter Monitor Group</span></span></span></span> ==
  
'''Figure 15: SFDC Web Service Input'''
+
Users can easily find the desired monitor group in the Monitor Group List by adding a filter to the SPC Monitor Group List page.&nbsp;A monitor group can be filtered under three conditions. They are,
  
[[File:SPC SFDC Web Service Input.png|700px|SPC_SFDC Web Service Input]]
+
#Group Name
 +
#Data Source Type
 +
#Shop Floor ID
  
'''Figure 16:&nbsp;New Monitor Group Page - SPI'''
+
'''Figure 10: Filter Monitor Group'''
  
[[File:SPC New Monitor Group Page - SPI.png|700px|SPC_New Monitor Group Page - SPI]]
+
[[File:SPC FilterMonitorGroup.png|900px]]
  
&nbsp;
 
  
'''Figure 17: New Monitor Group Page - DotLine Source'''
+
== <span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group">Delete Monitor Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
[[File:SPC New Monitor Group Page - DotLine Source.png|700px|SPC_New Monitor Group Page - DotLine Source]]
+
To delete a monitor group:
  
'''Note''': Since some data are manually collected by users and these kinds of data could not be extracted from 42Q, these data have been calculated and an API was provided to collect the data and present it to users in the Dot Line Chart. Below see a sample Dot line chart. See below some rules to get the DotLine Chart:
+
#From the Monitor Group List page, check the box of the monitor group to be deleted, and click &nbsp;'''Del'''.  
  
 
&nbsp;
 
&nbsp;
  
#First users need to create a new monitor with the below info specified:  
+
'''Figure 11: Delete Monitor Group'''
 +
 
 +
[[File:SPC deletemonitorgrouplist.png|900px|SPC deletemonitorgrouplist.png]]
  
&nbsp;Specify which process, parts... will be used for this monitor to collect data.
+
<u>'''Note''': </u>It is not allowed to delete the monitor group which contains one or more SPC Monitor.
  
'''&nbsp;Select Chart Type''': Dot Line.
+
= <span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance">Monitor Maintenance</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
  
When Dot Line Chart is selected,&nbsp; Application & Data Column is enabled to let
+
'''SPC''' portlet provides users with plenty of parameters to maintain SPC monitors. An SPC monitor is a platform for the setup of such processes as object monitoring, data collection strategy, rules, control charts, and actions. With the monitor maintenance function, you can create a new monitor, edit the existing monitor, disable or enable the monitor, show monitor data or control charts, lock the monitor, and so on. So monitoring maintenance is a key function of SPC.
  
users select which Application & Data Column will be used to display this chart.
+
&nbsp;
  
*Group By: Disabled.
+
== <span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route">Preparation Work: Associate Part Number With a Route</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
*Interval: Disabled.
+
 
*Rules & Actions: Enable.
+
MES SPC retrieves data from MDS via database view. To make the part number data configured in MDS to be displayed on the SPC monitor creation page, the part number must be manually assigned to a route.
<ol start="2">
 
<li>External Program will periodically pick data from Source Record by certain frequency and put into SPC by published;&nbsp;</li>
 
</ol>
 
  
'''API interface'''.
+
&nbsp;
<ol start="3">
 
<li>SPC TV will select Monitor will display.&nbsp;</li>
 
<li>Draw Chart: just like u/p chart current done in SPC.&nbsp;</li>
 
</ol>
 
  
'''X axis''': time collected(Import Datetime), Format: MMDDmm
+
=== <span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="1._Create_Part_Number">Create Part Number</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
'''Y axis:''' Data, UCL (Upper Control Limit), LCL Lower Control Limit(), Target.
+
To create a part number:
  
See the sequence below:
+
#Navigate to:&nbsp;'''Shop Floor Control > Configuration >&nbsp;Shop Floor&nbsp;Configuration''', and select the '''Part Number''' module.
 +
#From the Part Number List page, select '''Add Part Number'''&nbsp;to proceed.
 +
#In the Part Number Form float window, input some parameters to create the part number, and click the '''Save''' button.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 18: New Monitor DotLine Chart Monitor Tab'''
+
'''Figure 11: Part Number Form'''
  
[[File:SPC New Monitor DotLine Chart Monitor Tab.png|700px|New Monitor DotLine Chart Monitor Tab]]
+
'''[[File:SPC PartNumberForm.png|900px|SPC PartNumberForm.png]]'''
  
 
&nbsp;
 
&nbsp;
  
'''Figure 19: Data Collection Strategy Tab'''
 
 
[[File:SPC Data Collection Strategy Tab.png|700px|SPC_Data Collection Strategy Tab]]
 
 
It is not allowed to update the '''Data Collection Strategy '''if the DotLine source type is selected because the Dot Line chart is not a control chart, so these rules cannot be applied to the Dot line chart. In order to achieve the feature of sending an alert e-mail or change the background color to red, a rule must be set.
 
  
A new rule according to the characteristics of the Dot line chart was added: Consecutive points above or lower than UCL or LCL.
+
=== <span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="Associate_part_number_with_a_route"><span class="mw-headline" id="2._Associate_part_number_with_a_route">Associate part number with a route</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
 
&nbsp;
 
&nbsp;
  
'''Figure 20: New Monitor DotLine Chart Standard Control Chart Tab'''
+
#From the Shop Floor Configuration portlet, select '''Product Route''' to proceed.
 +
#In the List Route window, select the [[File:Pn route icon.png|RTENOTITLE]] icon on the right of the menu bar.
 +
#In the Part x Route Assignment List undefined window, select '''Add'''.
 +
#In the Part x Route Assignment Form undefined float window, select a&nbsp;'''shop floor ID''', input the&nbsp;'''part number''', and select a '''route'''.
 +
#Select '''Save''' to define the Part and Route assignment.
  
[[File:SPC New Monitor DotLine Chart Standard Control Chart Tab.png|700px|New Monitor DotLine Chart Standard Control Chart Tab]]
+
'''&nbsp;'''For more information, please visit&nbsp;'''[https://42qrpt1.42-q.com/mes_wiki/index.php/SOP-42Q-MES0011_Part_Number_Maintenance Part Number Maintenance SOP].'''
  
 
&nbsp;
 
&nbsp;
  
'''Figure 21: New Monitor DotLine Chart Available Charts Tab'''
+
&nbsp;
 
 
[[File:SPC New Monitor DotLine Chart Available Charts Tab.png|700px|SPC_New Monitor DotLine Chart Available Charts Tab]]
 
 
 
'''Select Data '''in the Drop Down List low users to select bot data1 and data2 at the same time.
 
 
 
'''Data1 or Data2''' can be understood as a group of data. Users can choose to display the two groups of data together in the dot line chart, or just display one group of data.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 22: New Monitor DotLine Chart Actions Tab'''
 
  
[[File:SPC New Monitor DotLine Chart Actions Tab.png|700px|SPC_New Monitor DotLine Chart Actions Tab]]
 
  
And finally, users can select the following actions:
 
  
'''Send an alert email''': This action sends an alert email to a specified person. Users can specify who would receive these alert emails in the Email Maintenance&nbsp;module.<br/> '''Change the background '''color to red: If the exception was triggered, the background of an associated data record in this monitor will turn red.&nbsp;
+
== <span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor">Create a New Monitor</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;See below a sample of DotLine Chart generated:&nbsp;
+
SPC monitors should be created under an existing monitor group.&nbsp;
  
'''Figure 23: New Monitor Group Page - Sample of Dot Line Chart'''
+
Users are able to set up monitors one by one part number for different production lines for one location/process, so there are too many monitors to be maintained, causing a workload for them to maintain these monitors in 42Q SPC. From one&nbsp;plant estimate, there are about 30,000 monitors to be created to support 42Q SPCs rolling out to the whole plant.&nbsp;
  
[[File:SPC New Monitor Group Page - Sample of Dot Line Chart.png|700px|SPC_New Monitor Group Page - Sample of Dot Line Chart]]&nbsp;&nbsp;
+
To solve this workload, users are able to do the following operations:
  
== <span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group"><span class="mw-headline" id="Edit_Monitor_Group">Edit Monitor Group</span></span></span></span></span></span> ==
+
*'''Create&nbsp; Monitors in Batch'''
 
+
**Support creates multi-part numbers/Family ID with one location/process/location family or multi-location/process/location family with one part numbers/Family id.
To edit a monitor group
+
**Allow users to export all the related attributes when creating a monitor.
 
+
**If selected part numbers have attributes, the attribute selection box in the new monitor>Data Collection Strategy page will only allow&nbsp;the common attributes.
#From the Monitor Group List page, check the box of a monitor group that you need to edit and select '''Edit'''. The Edit Monitor Group page is displayed.
+
**To create monitors in batch, users should fill in a batch ID. This batch ID will help users to do the operation of search or edit monitors. 
#Edit any field as needed, and select '''Save''' to save the change, or '''Cancel '''to abort.
+
*'''Edit&nbsp; Monitors in Batch'''  
 +
*'''Delete&nbsp; Monitors in Batch'''  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 24: Edit Monitor Group'''
+
#&nbsp;From the Monitor Group List page, select the&nbsp;[[File:Go-button.png|new server icon]] icon for a monitor group.
 
 
[[File:SPC Edit Monitor Group.png|700px|SPC_Edit Monitor Group]]
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 25: Edit Monitor Group Fields'''
+
'''Figure 13: Monitor Group List Page:&nbsp;Go'''
  
[[File:Edit Monitor Group Fields.png|700px|Edit Monitor Group Fields.png]]
+
[[File:SPC MonitorGroupListGop.png|900px|SPC MonitorGroupListGop.png]]
  
 
&nbsp;
 
&nbsp;
 +
<ol start="2">
 +
<li>From the Function List page, select the Monitor Maintenance Icon</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group"><span class="mw-headline" id="Delete_Monitor_Group">Delete Monitor Group</span></span></span></span></span></span> ==
+
'''Figure 14: Monitor Group List'''
  
To delete a monitor group,
+
'''[[File:SPC MonitorGroupFunctionList.png|900px|SPC MonitorGroupFunctionList.png]]'''
 
 
#From the Monitor Group List page, check the box of the monitor group to be deleted and click &nbsp;'''Delete'''.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 26: Delete Monitor Group'''
+
== <span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2"><span class="mw-headline" id="Monitor_Maintenance_2">Monitor Maintenance&nbsp;[[File:SPC MonitorMaintenanceIcon.png]]</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
[[File:SPC Delete Monitor Group.png|700px|SPC_Delete Monitor Group]]
+
The user now enters the New Monitor form. This page provides all parameters to set up a customized '''single monitor''' or '''monitors in batch '''in SPC.
  
'''Note''': It is not allowed to delete the monitor group which contains one or more SPC Monitor.
+
#On the Monitor List&nbsp;page, select the [[File:Add-new-icon.png|new monitor icon]] icon.  
  
= <span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance"><span class="mw-headline" id="Monitor_Maintenance">Monitor Maintenance</span></span></span></span> =
+
The user needs to fill in the necessary information in the available tabs to create monitors. See&nbsp;step by step in the next topic.
  
  
 +
=== <span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor">Monitor</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
 +
The first section is the Monitor.
  
=== <span class="mw-headline" id="Brief_Introduction_and_Preparation_Work"><span class="mw-headline" id="Brief_Introduction_and_Preparation_Work"><span class="mw-headline" id="Brief_Introduction_and_Preparation_Work"><span class="mw-headline" id="Brief_Introduction_and_Preparation_Work"><span class="mw-headline" id="Brief_Introduction_and_Preparation_Work"><span class="mw-headline" id="Brief_Introduction_and_Preparation_Work"><span class="mw-headline" id="Brief_Introduction_and_Preparation_Work">Brief Introduction and Preparation Work</span></span></span></span></span></span></span> ===
+
&nbsp;
 +
 
 +
'''Figure 15: Monitor Section'''
  
SPC portlet provides users plenty of parameters to maintain SPC monitors. An SPC monitor is a platform for the setup of such processes as object monitoring, data collection strategy, rules, control charts, and actions. With monitor maintenance function, you can create a new monitor, edit the existing monitor, disable or enable monitor, show monitor data or control charts, lock monitor, and so on. So monitor maintenance is a key function to SPC.
+
'''[[File:SPC MonitorSection.png|700px|SPC MonitorSection.png]]'''
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route"><span class="mw-headline" id="Preparation_Work:_Associate_Part_Number_With_a_Route">Preparation Work: Associate Part Number With a Route</span></span></span></span></span></span></span> ===
+
*'''Collect Data From''': Enable SPC to collect data from Now or from a past date.&nbsp;
 +
 
 +
<u>'''Note''':</u> Historical data that contains exceptions could stop the present production line. If a previous date is selected here and the option '''Send MFG Hold request to''' was checked when creating the server, then a user attempting to save the monitor at this point will be prompted by a warning that asks the user to confirm the decision to save.
  
MES 15 SPC 1.2.25 retrieves data from MDS via database view rather than Archive SFDC. To make the part number data that configured in MDS to be displayed in SPC monitor creation page, part number must be manually assigned to a route. To do so, you can follow the steps below. Users may skip instructions 1 and 2 below if a part number has already been created and the part number has been assigned to a route.&nbsp;
+
*'''Batch ID''': The name of the monitor or batch of monitors. This field cannot be edited as it is automatically set after the&nbsp;'''Part Number''', '''Family ID,''' and '''Location''', &nbsp;'''Process,''' and '''Location Family'''. If monitor data is automatically collected from MDS, the monitor name consists of two parts separated by a hyphen: The first part is Part Number / Family ID, and the second part is Location / Process / Location Family. If monitor data is collected manually via SPC UI, the monitor name will also contain the third part: the attribute name.&nbsp;
 +
*'''Part Number''': The part number to be monitored by SPC. The part number is created and configured in MDS before being created in the SPC monitor. The Part Number option is selected by default. Users must enter a specific part number or select one from the associated drop-down box.&nbsp;  
  
#<span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="Create_Part_Number"><span class="mw-headline" id="1._Create_Part_Number">Create Part Number</span></span></span></span></span>
+
&nbsp;
  
To create a part number,
+
<u>'''[[File:Lightbulb icon.png|60px|Lightbulb icon.png]]TIP:'''</u>&nbsp;When users enter four characters into the field, the portlet will automatically begin searching and listing any part numbers that match the input. To date, the Part Number, Family ID, Location, Process, and Location Family fields support this search-as-you-type feature.&nbsp;
<ol style="margin-left: 40px;">
 
<li>1 Navigate to '''Shop Floor Control > SFDC Configuration''', and select the '''Part Number''' module.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 27: SFDC&nbsp;Configuration Part Number Module'''
+
*'''Family ID''': The Family ID is to be monitored by SPC. Family ID is created and configured in MDS before being created in the SPC monitor. Users must select the Family ID option manually and either enter the family ID or select one from the drop-down box.
 +
*'''Location''': The location is to be monitored by SPC. Location is created and configured in MDS before being created in the SPC monitor. The Location option is selected by default. Users must enter or choose a location from the associated drop-down box.&nbsp;  
  
[[File:SOP-5-I-MES0069-C SFDC Configuration Part Number Module.jpg|RTENOTITLE]]
+
<u>'''Note:'''</u> Attribute is associated with part number + location or part number + process.&nbsp; If a&nbsp; monitor is created with part number A + location B and part number A + process B, some attributes will be associated, then the user can create Continuous control charts. The associated attributes can be viewed in the '''Data Collection Strategy''' tab.
  
&nbsp;
+
*'''Process''': The process to be monitored by SPC. The process is created and configured in MDS before being created in the SPC monitor. Users must select the Process option manually and then enter or choose a process from the drop-down box.  
<ol start="2">
 
<li>From the Part Number List page, select '''Add Part Number'''&nbsp;to proceed.</li>
 
</ol>
 
  
&nbsp;
+
<u>'''Note''':</u> If the "Route by Process" option is enabled in SFDC when a new monitor is being created, the user may select either Part Number and Location or Part Number and Process.&nbsp; However, if the Mfg Hold submodule is to be used to perform a hold on a serial number for a certain part number, the respective monitor should be created by selecting Part Number and Process, not Part Number and Location.
  
'''Figure 28: Part Number Main Page'''
+
*'''Location Family''': The location family is to be monitored by SPC. Location Family is created and configured in MDS before being created in the SPC monitor. Users must select the Location Family option manually, and then enter by&nbsp;choosing a location family from the drop-down box.
  
[[File:New pn button.png|700px|New pn button.png]]
+
<u>'''Note'''</u>: Some plans have more part number records but don’t have a relation with the route. The system will create a monitor with Part Numbers that should be relative to shop orders. Part Number/Family ID needs to set up a relation with the shop order whose status is&nbsp;Release.
<ol start="3">
 
<li>In Part Number Form float window, input some parameters to create the part number, and click the Save button.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 29: Part Number Form'''
+
=== <span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy">Data Collection Strategy</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:New pn form.png|700px|New pn form.png]]
+
The second section is the '''Data collection strategy'''. According to the data chosen (Part Number and Location) at the Monitor tab, the user can create continuous control charts.
  
 
&nbsp;
 
&nbsp;
<ol start="3">
 
<li><span class="mw-headline" id="2._Associate_part_number_with_a_route">3 Associate part number with a route</span></li>
 
</ol>
 
  
&nbsp;
+
'''Figure 16:&nbsp;<font face="Times New Roman, serif"><font size="2">Data Collection Strategy</font></font>'''
  
#From the SFDC Configuration portlet, select '''Product Route''' to proceed.  
+
[[File:SPC DataCollectionStrategy .png|700px|SPC DataCollectionStrategy .png]]
  
 
&nbsp;
 
&nbsp;
  
'''Figure 30: SFDC&nbsp;Configuration Product Route Module'''
+
*'''Automatic Collection from Unit''': Allows SPC monitor to automatically collect data from MDS&nbsp;service. This option is selected&nbsp;by default.
 +
*'''Manual collection via SPC UI''':&nbsp; Allow end users to manualy collection continuous data vis SPC ui(Input feature in SPC).
 +
*'''Automatic Collection via SPC API''': With this option the users can create a monitor with Automatic Collection Via SPC API type and clients (such as PWB), which can push the data to SPC via its monitor API as long as the characteristics in the parameters of the API endpoint exist and match this monitor, the continuous data control charts (such as X bar-R chart, I-MR chart, and CPK/PPK report) will plot.
 +
*'''Subgrouping Method''': This field defines the rules of how data should be organized to form a series of points plotted on control charts. It consists of the following components: Unit Quantity, Time, Subgroup&nbsp;Size textbox (if Unit Quantity is selected), and Time Range drop-down box (if&nbsp;Time is selected).
 +
*'''Unit Quantity''': &nbsp;The data will be grouped by quantity. The quantity is defined in the Sample Size textbox. For example, if a data source contains 100 data items and the sample size value is 2, then this data source will be divided into 50 groups (100 / 2 = 50). This radio button is chosen by default.&nbsp;
 +
*'''Time''': The data will be grouped by time range. For example, if a sampling period is 60 minutes and the time range is 10 minutes, then this sample period will contain 6 groups of data (60 / 10 = 6). Users must manually select the By Time option.
  
[[File:SOP-5-I-MES0069-C SFDC Configuration Product Route Module.jpg|RTENOTITLE]]
+
&nbsp;
  
&nbsp;
+
The sampling rules are customized by the user. The sampling method is divided into '''by'''&nbsp;'''time period sampling''' and by '''quantity sampling'''. The time and quantity can be set in SPC&nbsp;(The default sampling is the first serial number).&nbsp;
<ol start="2">
 
<li>In the List Route window, select the [[File:Pn route icon.png|RTENOTITLE]] icon on the right of the menu bar.</li>
 
</ol>
 
  
&nbsp;
+
<u>'''Note:'''</u> If there is no data in this sampling range, no new points will be created in X bar - R chart).
  
'''Figure 31: Product Route Main Page with Icon Highlighted'''
+
'''<u>Note 2:</u> '''It is not allowed to update the Data Collection Strategy if the DotLine source type is selected because the Dot Line chart is not a control chart, so these rules cannot be applied to the Dot line chart. To achieve the feature of sending an alert email or changing the background color to red, a rule must be set.
  
[[File:Product Route Main Page with Icon Highlighted.png|Product Route Main Page with Icon Highlighted]]
+
&nbsp;A new rule according to the characteristics of the Dot line chart was added: Consecutive points above or lower than UCL or LCL.
  
&nbsp;
+
SPC supports Continuous data and Discrete data control charts in one monitor. Users can choose one of them or the two control charts.
<ol start="3">
 
<li>In the Part x Route Assignment List undefined window, select '''Add'''.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 32: Product x Route Assignment List'''
+
'''Figure 17: Data Collection Strategy&nbsp;- Continuous Data'''
 
 
[[File:Product x Route Assignment List.png|Product x Route Assignment List]]
 
  
&nbsp;
+
'''[[File:SPC DataCollectionStrategy ContinuousData.png|700px|SPC DataCollectionStrategy ContinuousData.png]]'''
<ol start="4">
 
<li>In the Part x Route Assignment Form undefined float window, select a shop floor ID, input the part number, and select a route.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 33: Part x Route Assignment Form'''
+
'''Figure 18: Data Collection Strategy for Discrete Control Charts - Discrete Data'''
  
[[File:Pr form.png|300px|Pr form.png]]
+
'''[[File:SPC Data Collection Strategy Discrete Data.png|700px|SPC Data Collection Strategy Discrete Data.png]]'''
  
 
&nbsp;
 
&nbsp;
Line 504: Line 467:
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor"><span class="mw-headline" id="Create_a_New_Monitor">Create a New Monitor</span></span></span></span> ==
+
==== <span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method"><span class="mw-headline" id="Sampling_Method">Sampling Method</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
In MES 15 Quality '''SPC 1.2.25''', SPC monitors should be created under an existing monitor group.&nbsp;
+
The sampling method belongs only to continuous charts. This field defines the rules on how data should be organized to form a series of points plotted on control charts. It consists of the following components:
  
Users are able to set up monitors one by one part number for different production lines for one
+
*'''Full''' (Full Inspection).&nbsp;
 +
*'''Every X Units''': Users can input the numbers of units. For example, 5, means the system will select one unit from every 5 units.
 +
*'''Every X Time''': Users can select the time from the drop-down list. Options: 10 minutes, 15 minutes, 20 minutes, 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours,8 hours, 12 hours, 24 hours.
  
location/process, so there are too many monitors to be maintained, causing workload for them to maintain
+
The original system defaulted to a FULL inspection, without configuration. For every Unit and Every time sampling, the system defaults to extract the first serial number of this time period/quantity for statistics.
  
these monitors in 42Q SPC. From E85 plant estimated, there are about 30,000 monitors to be created to support
+
Now with Attribute&nbsp;Maintenance Configuration, it is possible to check whether the attribute is in the same group.&nbsp;
  
42Q SPC’s rolling out to the whole plant.&nbsp;
+
The current SPC&nbsp; has an attribute grouping control logic. Only the same type of attribute can be monitored in a monitor, otherwise, it will prompt a warning message. To turn the SPC attribute grouping logic consistent with the actual SFDC attribute grouping rules, new rules were created for the attributes. According to the Attribute Maintenance Configuration, it is possible to check whether the attribute is in the same group.
  
To solve this workload, users are able to do the following operations:
+
'''<u>Note:</u> '''Only the attributes in the same attribute group can be monitored together in one monitor.
  
*'''Create&nbsp; Monitors in Batch'''
+
&nbsp;
**Support creates multi-part numbers/Family id with one location/process/location family or multi-location/process/location family with one part numbers/Family id&nbsp;;
 
**Allow users to export all the related attributes when creating a monitor;
 
**If selected part numbers that have attributes, the attribute selection box in the new monitor>Data Collection Strategy page only allows the common attributes.
 
**To create monitors in batch, users should fill a batch id. This batch id will help users to do the operation of search or edit monitors. 
 
*'''Edit&nbsp; Monitors in Batch'''
 
*'''Delete&nbsp; Monitors in Batch'''
 
 
 
#&nbsp;From the Monitor Group List page, select the&nbsp;[[File:Go-button.png|new server icon]] icon for a monitor group.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 34: Monitor Group List Page with Go Icon Highlighted'''
+
=== <span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart">Standard Control Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:Monitor Group List Page with Go.png|700px|Monitor Group List Page with Go.png]]
+
The following section is the&nbsp;Standard Control Chart, which contains two sub-sections: '''Interval''' and&nbsp;'''Rules'''.
  
 
&nbsp;
 
&nbsp;
  
The Functional List page is displayed:&nbsp;
+
'''Figure 19: Standard Control Chart'''
<ol start="2">
+
 
<li>From the Function List page, select&nbsp;[[File:Monitor-maintenance-icon.png|monitor maintenance icon]] (Monitor Maintenance).</li>
+
'''[[File:SPC StandardControlChart.png|700px|SPC StandardControlChart.png]]'''
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 35: SPC&nbsp;Function List Page'''
+
==== <span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval">Interval</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
[[File:SPC Function List Page.png|700px|SPC Function List Page.png]]
+
This subsection defines the frequency at that SPC recalculates the center line value of a control chart. Here valid groups are used as the frequency unit. It is allowed to use a new monitor with different grouping methods:
  
 
&nbsp;
 
&nbsp;
<ol start="3">
 
<li>On the Monitor List&nbsp;page, select the [[File:Add-new-icon.png|new monitor icon]] icon.</li>
 
</ol>
 
  
&nbsp;
+
'''Figure 20: Interval Section'''
 +
 
 +
[[File:SPC IntervalSection.png|900px|SPC IntervalSection.png]]
  
'''Figure 36: SPC Monitor List Page'''
+
#No grouping and without recalculating bar values
 +
#Allow the user to set the number of groups, and calculate the new BAR value used for the next data analysis
 +
#Allow user to set the number of groups, use the same BAR value used for the next data analysis
  
[[File:SPC Monitor List Page1.png|700px|SPC Monitor List Page]]
+
See below a sample of the chart:
  
 
&nbsp;
 
&nbsp;
  
'''Figure 37: New Monitor Form'''
+
'''Figure 21: Chart Sample for Valid Group'''
  
[[File:New Monitor Form1.png|700px|New Monitor Form]]
+
[[File:SPC Chart Sample for Valid Group.png|900px|Chart Sample for Valid Group]]
  
The user now enters the New Monitor&nbsp;page. This page provides all parameters for you to set up a customized monitor in SPC. These parameters are divided into multiple sections. These sections are clarified below:
+
&nbsp;
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor"><span class="mw-headline" id="Monitor">Monitor</span></span></span></span> ===
+
==== <span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules">Rules</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
The first section is the Monitor.
+
This sub-section lists all seven rules which are considered to be out-of-control exceptions. Users can select one or more rules in this checkbox group.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 38: Monitor Section'''
+
'''Figure 22: Rules Section'''
  
[[File:Monitor Section.png|700px|Monitor Section]]
+
[[File:SPC RulesSection.png|900px|SPC RulesSection.png]]
  
'''Batch ID''': The name of the monitor or batch of monitors. This field cannot be edited as it is automatically set after the&nbsp;'''Part Number''', '''Family ID,''' and '''Location''', &nbsp;'''Process,''' and '''Location Family'''. If monitor data is automatically collected from SFDC, the monitor name consists of two parts separated by a hyphen: The first part is Part Number / Family ID, the second part is Location / Process / Location Family. If monitor data is collected manually via SPC UI, the monitor name will also contain the third part: the attribute name.&nbsp;
+
Consecutive Points above or lower than UCL or LCL option will be available if&nbsp;the selected data source is '''DotLine Source'''.
  
 
&nbsp;
 
&nbsp;
  
'''Collect Data From''': Enable SPC to collect data from Now or from a past date.&nbsp;
+
'''Figure 23: New Monitor DotLine Chart Standard Control Chart Tab'''
  
'''Note''':&nbsp;Historical data that contains exceptions could stop the present production line. If a previous date is selected here and the option '''Send MFG Hold '''request to was checked when creating the server, then a user attempting to save the monitor at this point will be prompted by a warning that asks the user to confirm the decision to save.&nbsp;
+
[[File:SPC StandardControlChartUCL LCL.png|700px|SPC StandardControlChartUCL LCL.png]]
  
 
&nbsp;
 
&nbsp;
  
'''Part Number''': The part number to be monitored by SPC. The part number is created and configured in MDS before being created in the SPC monitor. The Part Number option is selected by default. Users must enter a specific part number or select one from the associated drop-down box.&nbsp;
+
&nbsp;
  
TIP:&nbsp;When users enter four characters into the field, the portlet will automatically begin searching and listing any part numbers that match the input. To date, the Part Number, Family ID, Location, Process, and Location Family fields support this search-as-you-type feature.&nbsp;
+
=== <span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts">Available charts</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
'''Family ID''': The Family ID to be monitored by SPC. Family ID is created and configured in MDS before being created in the SPC monitor. Users must select the Family ID option manually and either enter the family ID or select one from the drop-down box.
+
This tab displays all available control charts, DPMO, and Other Charts in the current context. The '''SPC Control Chart '''is generated based on the data source that is configured in the Monitor&nbsp;section so that different configurations in the Monitor&nbsp;section may have different available charts. Users can choose one or more control charts in this checkbox group.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 39: Family ID'''
+
'''Figure 24: Available Charts&nbsp;(non Continuous control charts)'''
  
[[File:SPC Family ID.png|Family ID]]
+
[[File:SPC AvailableCharts.png|700px|SPC AvailableCharts.png]]
  
'''Location''': The location to be monitored by SPC. Location is created and configured in MDS before being created in the SPC monitor. The Location option is selected by default. Users must enter or choose a location from the associated drop-down box.&nbsp;
+
<br/> The textbox on the right of the chart name is used for defining the centerline value of the control chart. For example, if a user chooses the C Chart checkbox, the C-Bar textbox becomes available. Users can then manually enter a number in the textbox, which becomes the centerline value of the chart.
  
NOTE: Attribute is associated with part number + location or part number + process.&nbsp; If a&nbsp; monitor is created with part number A + location B and part number A + process B some attributes will be associated, then the user can create Continuous control charts. The associated attributes can be viewed at the '''Data Collection Strategy''' tab.
+
'''Figure 25: C-Chart Field'''
  
&nbsp;
+
'''[[File:SPC C-Chart Field.png|900px|SPC C-Chart Field.png]]'''
  
'''Figure 40: Location'''
+
<br/> <u>'''Note''':</u> Be careful with the values entered in the textbox for control charts if the line stoppage function is enabled. If the Send MFG Hold Request to&nbsp;MDS checkbox was selected when creating an SPC server, SPC may stop the production line if a user defines unreasonable values for the control chart based on the rules&nbsp;selected.
  
[[File:SPC Location.png|Location]]
+
For '''FPY Chart''', selecting the '''Display'''&nbsp;checkbox enables SPC to display the FPY chart on the monitor. The '''Trigger&nbsp;'''checkbox enables an out-of-control warning.
  
'''Process''': The process to be monitored by SPC. The process is created and configured in MDS before being created in the SPC monitor. Users must select the Process option manually and then enter or choose a process from the drop-down box.
+
<br/> '''<u>Note:</u> '''The Current SPC allows users to choose a specific version to display FPY charts.
  
 
&nbsp;
 
&nbsp;
  
'''Note''': If the "Route by Process" option is enabled in SFDC when a new monitor is being created, the user may select either Part Number and Location or Part Number and Process.&nbsp; However, if the Mfg Hold submodule is to be used to perform a hold on a serial number for a certain part number, the respective monitor should be created by selecting Part Number and Process, not Part Number and Location.
+
==== <span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart"><span class="mw-headline" id="C-Chart">C-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
&nbsp;
+
C-chart is an attribute control chart used with data collected in subgroups that are the same size.&nbsp;
 +
 
 +
It shows how the process, measured by the number of nonconformities per item or group of items, changes over time. Nonconformities are defects or occurrences found in the sampled subgroup.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 41: Process'''
+
'''Figure 26: C Chart'''
 +
 
 +
[[File:SPC C Chart.png|900px|C Chart]] &nbsp;
 +
 
 +
&nbsp;
  
[[File:SPC Process.png|Process]]
+
==== <span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart"><span class="mw-headline" id="U-Chart">U-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
<br/> '''Location Family''': The location family to be monitored by SPC. Location Family is created and configured in MDS before being created in the SPC monitor. Users must select the Location Family option manually, and then enter of choosing a location family from the drop-down box.
+
U-chart is an attribute control chart used with data collected in subgroups of varying sizes. U-charts show how the process, measured by the number of nonconformities per item or group of items, changes over time.
  
&nbsp;
+
<br/> &nbsp;
  
'''Figure 42:Location Family'''
+
'''Figure 27: U Chart'''
  
[[File:Location Family1.png|Location Family]]
+
[[File:SPC U Chart.png|900px|U Chart]]
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
==== <span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart"><span class="mw-headline" id="NP-Chart">NP-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
 +
NP-chart is an attribute control chart used with data collected in subgroups that are the same size. NP-charts show how the process, measured by the number of nonconforming items it produces, changes over time.
  
=== <span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy"><span class="mw-headline" id="Data_Collection_Strategy">Data Collection Strategy</span></span></span></span></span></span> ===
+
'''Figure 28: NP Chart'''
  
The second section is the '''Data collection strategy'''. According to the data chosen (Part Number and Location) at the Monitor tab, the user can create continuous control charts.
+
[[File:SPC NP Chart.png|900px|NP Chart]]
  
 
&nbsp;
 
&nbsp;
  
'''Figure 43:&nbsp;<font face="Times New Roman, serif"><font size="2">Data Collection Strategy for&nbsp;</font></font>Non Continuous control charts'''
+
&nbsp;
  
[[File:SPC Data Collection Strategy1.png|Data Collection Strategy]]
+
==== <span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart"><span class="mw-headline" id="P-Chart">P-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
<br/> '''Auto collection from SFDC''': Allows SPC monitor to automatically collect data from SFDC service. This option is chosen by default.
+
P-chart is an attribute control chart used with data collected in subgroups of varying sizes. Because the subgroup size can vary, it shows a proportion on nonconforming items rather than the actual count. P-charts show how the process changes over time.
  
 
&nbsp;
 
&nbsp;
  
'''Manual collection via SPC UI''': This availability of these options is determined by the settings in the Monitor section.&nbsp;&nbsp;If the Monitor section contains attribute data, then the option is available; otherwise, this option is unavailable.
+
'''Figure 29: P Chart'''
 +
 
 +
[[File:SPC PChart.png|900px|SPC PChart.png]]
  
 
&nbsp;
 
&nbsp;
  
'''Group by''': This field defines the rules of how data should be organized to form a series of points plotted on control charts. It consists of the following components: By Unit Quantity, By Time, Sample Size textbox (if By Unit Quantity is selected), and Time Range drop-down box (if By Time is selected).
+
==== <span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart"><span class="mw-headline" id="FPY-Chart">FPY-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
*'''By Unit Quantity''': The data will be grouped by quantity. The quantity is defined in the Sample Size textbox. For example, if a data source contains 100 data items and the sample size value is 2, then this data source will be divided into 50 groups (100 / 2 = 50). This radio button is chosen by default.
+
FPY is a First Pass Yield:&nbsp;
  
*'''By Time''': The data will be grouped by time range. For example, if a sampling period is 60 minutes and the time range is 10 minutes, then this sample period will contain 6 groups of data (60 / 10 = 6). Users must manually select the By Time option.  
+
*Capable of plotting the First Pass Yield of a product at a particular process step over a period of time or number of boards.  
 +
*Capable of manual configuration the upper control limit and lower control limit.
 +
*Can displays the target (Goal) line.  
 +
*Capable to use the 7 Rule alarms for triggering.
 +
*Capable to trigger the alarm when FPY falls below the Target Line.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 44: Group By'''
+
'''Figure 30: FPY Chart'''
  
[[File:SPCGroup by time.png|700px|Group by time.png]]
+
[[File:SPC FPY Chart.png|900px|FPY Chart]]
  
 
&nbsp;
 
&nbsp;
  
The sampling rules are customized by the user. The sampling method is divided into '''by'''&nbsp;'''time period sampling''' and by '''quantity sampling'''. The time and quantity can be set in SPC. (Default sampling first serial number.&nbsp;
+
&nbsp;
  
NOTE: If there is no data in this sampling range, no new points will be created in X bar - R chart).
+
==== <span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO"><span class="mw-headline" id="DPMO">DPMO</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
&nbsp;
+
'''Figure 31: DPMO Chart Types'''
  
'''Figure 45: Data Collection Strategy for Continuous control charts'''
+
'''[[File:SPC DPMOChartTypes.png|900px|SPC DPMOChartTypes.png]]'''
  
[[File:SPC Data Collection Strategy for Continuous control charts.png|700px|Data Collection Strategy for Continuous control charts]]
+
&nbsp;
  
Sampling by: Sampling by belongs only to continuous charts. This field defines the rules on how data should be organized to form a series of points plotted on control charts. It consists of the following components:
+
*'''DPMO Chart''': This enables SPC to monitor a manufacturing line with a DPMO chart. '''Defect opportunity'''&nbsp;and '''UCL'''&nbsp;represent the two parameters used for defining DPMO charts.  
  
*'''By Unit Quantity''',&nbsp;
+
<u>'''Note''':</u> The other 4 charts are custom made by the company according to the specific defect code. For example:<br/> &nbsp;
*'''By Time''', Sample Size textbox (if By Unit Quantity is selected),&nbsp;
 
*'''Time Range''' drop-down box (if By Time is selected) and&nbsp;
 
*'''Full''' (Full Inspection).&nbsp;  
 
  
The original system defaulted to a FULL inspection, without configuration. Due to the requirements for random sampling of E85 plant, we have added '''By-Time Sampling '''and '''By-Unit Quantity Sampling'''. By time and By quantity sampling, the system defaults to extract the first serial number of this time period/quantity for statistics.
+
*'''DPMO-Placement Chart''': Placement is a defect code name. The chart is only for this defect code. The other 3 charts are the same
 +
*'''DPMO-Termination Chart: '''Termination is a defect code type. The chart is only for this defect code
 +
*'''DPMO-Assembly Chart: '''Assembly is a defect code type. The chart is only for this defect code
 +
*'''DPMO-Component Chart:''' Component is a defect code type. The chart is only for this defect code
  
Before'''SPC 1.2.25, '''only the attributes with the same prefix would be recognized as a group. Now, according to the Attribute Maintenance Configuration, it is possible to check whether the attribute is in the same group.&nbsp;
+
&nbsp;
  
The current SPC&nbsp; has an attribute grouping control logic. Only the same type of attribute can be monitored in a monitor, otherwise, it will prompt a warning message. To turn the SPC attribute grouping logic consistent with the actual SFDC attribute grouping rules, new rules were created for the attributes. According to the Attribute Maintenance Configuration, it is possible to check whether the attribute is in the same group.
+
==== <span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts"><span class="mw-headline" id="Other_Charts">Other Charts</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
'''Note: '''Only the attributes in the same attribute group can be monitored together in one monitor.
+
The Other Control Chart section, has the following components:
  
 
&nbsp;
 
&nbsp;
  
'''Figure 46: SFDC Configuration - Attribute Configuration'''
+
'''Figure 32: Other Chart'''
  
[[File:SPC SFDC Configuration - Attribute Configuration.png|700px|SFDC Configuration - Attribute Configuration]]
+
'''[[File:SPC OtherChart.png|900px|SPC OtherChart.png]]'''
  
 
&nbsp;
 
&nbsp;
  
'''Comparative Table:'''&nbsp;
+
===== <span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart"><span class="mw-headline" id="Yield_-Chart">Yield -Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span> =====
  
{| border="1" class="wikitable"
+
Enables SPC to monitor the manufacturing line with the Yield chart. The limit is a parameter used for defining the Yield chart.This chart shows the Yield value for a selected or retrieved process, one at a time, and a list of the N last products passed on this process.
|-
 
| &nbsp;
 
|
 
Before SPC 1.2.25
 
  
|
+
&nbsp;
SPC 1.2.25
 
  
|-
+
'''Figure 33: Yield Chart'''
|
 
Rule
 
  
|  
+
[[File:SPC Yield Chart.png|900px|Yield Chart]]
Only the attributes with the same prefix will be recognized as a group
 
  
|
+
&nbsp;
According to the configuration of SFDC configuration to distinguish whether a group
 
  
|-
+
&nbsp;
|
 
Attribute Name
 
  
|
+
&nbsp;
Temperature-01
 
  
Temperature-02
+
&nbsp;
  
Temperature-03
+
===== <span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart"><span class="mw-headline" id="Pareto_Chart">Pareto Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =====
  
Temperature-04
+
Enables SPC to monitor the manufacturing line with a Pareto chart. Users can define a Pareto chart exception rule by selecting the Create exception when checkbox and entering, for example, 3 Defect codes of the same type within 10 Minutes.
  
Temperature-05
+
The Pareto chart indicates which problem to tackle first by showing the proportion of the total problem that each of the
  
|
+
smaller problems comprises. It is a type of chart that contains both bars and a line graph, where individual values
AR7
 
  
C100
+
are represented in descending order by bars, and the cumulative total is represented by the line.
  
C108
+
&nbsp;
  
C109
+
'''Figure 34: Pareto Chart'''
  
C1091
+
[[File:SPC Pareto Chart.png|900px|Pareto Chart]]
  
C1-1
+
&nbsp;
  
C1139
+
For continuous control charts, users have to select Manual Collection and Multiple Units, Single Characteristics at the (Data collection strategy ) tab, then go to Available Charts, will get to see these options.
  
C117
+
&nbsp;
  
|-
+
'''Figure 35: Available Control Charts for Continuous Control Charts&nbsp;'''
|
 
Attribute Group
 
  
|  
+
'''[[File:Figure 48- Available Control Charts for Continuous control charts1.png|700px|Figure 48- Available Control Charts for Continuous control charts1.png]]'''
Temperature
 
  
|
+
===== <span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart"><span class="mw-headline" id="XBar-Chart">XBar-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =====
BOTTOM_STENCIL1
 
  
|}
+
X-bar and R (range) chart is a pair of control charts used with processes that have a subgroup size of two or more.&nbsp;
 +
 
 +
The standard chart for variables data, X-bar, and R charts help determine if a process is stable and predictable. The X-bar chart shows how the mean or average changes over time and the R chart shows how the range of the subgroups changes over time.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 47: Sampling By'''
+
'''Figure 36: XBar Chart'''
  
[[File:SPC Sampling By.png|700px|Sampling By]]
+
[[File:SPC XBar Chart.png|900px|XBar Chart]]
  
'''Figure 48: Export Attributes XLS'''
+
&nbsp;
  
[[File:SPC Export Attributes XLS.png|700px|Export Attributes XLS]]
 
  
&nbsp;
+
===== <span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart"><span class="mw-headline" id="R-Chart">R-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =====
  
=== <span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart"><span class="mw-headline" id="Standard_Control_Chart">Standard Control Chart</span></span></span></span> ===
+
The X-bar chart shows how the mean or average changes over time and the R chart shows how the range of the subgroups changes over time.
  
The following section is the&nbsp;Standard Control Chart, which contains three sub-sections: Interval, Rules, and Available charts.
+
<u>'''Note''':</u> LCL can’t be negative. Both S (Standard Deviation) and R (Range) can't be negative, due to their nature. All the points that the user scans are displayed on the chart and when expanding chart details, all the information in the chart page is collected such as SPC Collection time, Average, LCL, UCL, OCAP, attributes, etc. There are no negative numbers on the Y-axis.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 49: Standard Control Chart'''
+
'''Figure 37: R Chart'''
  
[[File:SPC Standard Control Chart.png|700px|Standard Control Chart]]
+
[[File:SPC R Chart.png|900px|R Chart]]
  
 
&nbsp;
 
&nbsp;
  
==== <span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval"><span class="mw-headline" id="Interval">Interval</span></span></span></span></span> ====
+
*'''I-MR''' Chart I-MR chart is a combination of two charts (Individual and Moving Range) is to track the process variability based on the samples taken from a process over the period of time. An Individual moving range (I-MR ) chart is used when data is continuous and not collected in subgroups.
  
This sub-section has a checkbox and a textbox that defines the frequency that SPC recalculates the center line value of a control chart. Here valid groups are used as the frequency unit.
+
&nbsp;
  
&nbsp;
 
  
'''Figure 50: Interval Section'''
+
===== <span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart"><span class="mw-headline" id="CPK.2FPPK-Chart">CPK/PPK-Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =====
  
[[File:SPC Interval Section.png|700px|Interval Section]]
+
Cpk is the potential of a process to meet a specification (short term) while Ppk is how the process actually did (long term).
  
#No grouping and without recalculate bar values
+
The&nbsp;'''Method of Std Dev(within)'''&nbsp;in the cpk/ppk chart has three available options:
#Allow user set the number of groups, calculate new BAR value used for the next data analysis
 
#Allow user to set the number of groups, use the same BAR value used for the next data analysis
 
  
See below a sample of the chart:
+
*'''Pool standard deviation'''
 +
*'''R Bar'''
 +
*'''Average moving range'''.
  
&nbsp;
+
The method used to&nbsp;'''Std Dev(within)''' depends on the subgroup size.
  
'''Figure 51: Chart Sample for Valid Group'''
+
When '''subgroup size > 1,''' SPC estimates '''Std Dev(within)''' using one of the following two methods: '''Pooled''' '''standard''' deviation and an average'''&nbsp;of subgroup ranges (Rbar),''' SPC selects&nbsp;'''Pooled standard deviation''' method by default.
  
[[File:SPC Chart Sample for Valid Group.png|700px|Chart Sample for Valid Group]]
+
When'''subgroup size = 1''', SPC estimates '''Std Dev(within)''' using the Average moving range method.
  
&nbsp;
+
See below the description and samples of the main available charts at SPC:
  
&nbsp;
+
CPK/PPK shows if the real process capability meets the specification
  
==== <span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules"><span class="mw-headline" id="Rules">Rules</span></span></span></span></span> ====
+
Definitions
  
This sub-section lists all seven rules which are considered to be out-of-control exceptions. Users can select one or more rules in this checkbox group.
+
*&nbsp;Cp= Process Capability. A simple and straightforward indicator of process capability.
 +
*&nbsp;Cpk= Process Capability Index. Adjustment of Cp for the effect of non-centered distribution.
 +
*&nbsp;Pp= Process Performance. A simple and straightforward indicator of process performance.
 +
*&nbsp;Ppk= Process Performance Index. Adjustment of Pp for the effect of non-centered distribution.  
 +
*Cpk is for the short term, and Ppk is for the long term.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 52: Rules Section'''
+
====== <span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk"><span class="mw-headline" id="Cp_and_Cpk">Cp and Cpk</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ======
  
[[File:SPC Rules Section.png|700px|Rules Section]]
+
It is common to express process capability in terms of:
  
Consecutive Points above or lower than UCL or LCL option will be available in the selected data source is '''DotLine Source'''.
+
*How well can we meet the customer’s specifications?
 +
*Voice of Customer / Voice of the process
 +
*It is a potential capability index - Cp is defined as:
  
&nbsp;
+
&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp; Cp = USL – LSL/6σst
  
==== <span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts"><span class="mw-headline" id="Available_charts">Available charts</span></span></span></span></span> ====
+
The minimum acceptable value for Cp is normally considered to be 1
  
This tab displays all available control charts, DPMO, and Other Charts in the current context. The '''SPC Control Chart '''is generated based on the data source that is configured in the Monitor&nbsp;section so that different configurations in the Monitor&nbsp;section may have different available charts. Users can choose one or more control charts in this checkbox group.
+
Cpk = Min (USL- x, x – LSL)/3σst
  
&nbsp;
+
When there is no shift or drift, Cpk and Cp are equal. As the process drifts, Cpk gets smaller.&nbsp;
 +
 
 +
&nbsp;
  
'''Figure 53: Available Charts&nbsp;(non Continuous control charts)'''
+
====== <span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart"><span class="mw-headline" id="Pp_and_Ppk_Chart">Pp and Ppk Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ======
  
[[File:SPC Available Charts.png|700px|Available Charts]]
+
Over time, the drift in the process will have the effect of ‘flattening out’ the distribution, and the standard deviation of the process will increase.&nbsp; To reflect this effect properly, we define two long term capability indices, Pp and Ppk.
  
<br/> The textbox on the right of the chart name is used for defining the centerline value of the control chart. For example, if a user chooses the C Chart checkbox, the C-Bar textbox becomes available. Users can then manually enter a number in the textbox, which becomes the centerline value of the chart.
+
These indices have the same formulas as their short term counterparts, but use the long term standard deviation in their denominators, σlt
 +
 
 +
Pp = USL – LSL/ 6σlt &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Ppk = Min (USL- x, x – LSL)/3σlt
  
 
&nbsp;
 
&nbsp;
  
'''Figure 54: C-Chart Fields'''
+
'''Figure 38: CPK/PPK Chart'''
  
[[File:Choose c-chart.png|500px|Choose c-chart.png]]
+
[[File:SPC CPKPPKchart.png|900px|SPC CPKPPKchart.png]]
  
<br/> '''Note''': Be careful with the values entered in the textbox for control charts if the line stoppage function is enabled. If the Send MFG Hold Request to SFDC / MDS checkbox was selected when creating an SPC server, SPC may stop the production line if a user defines unreasonable values for the control chart based on the rules&nbsp;selected.
 
  
For '''FPY Chart''', selecting the '''Display'''&nbsp;checkbox enables SPC to display FPY chart in the monitor. The '''Trigger&nbsp;'''checkbox enables an out-of-control warning.
+
=== <span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions">Actions&nbsp;&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
<br/> Before SPC 3.2, SPC Cpk / Ppk Chart data has only one revision that contains all data. This is inconvenient particularly when a user wants to generate a Cpk / Ppk Chart once a month for their clients. Beginning with SPC 3.2, Cpk / Ppk Chart adds a date range setting function enabling the user to set a date range for Cpk / Ppk chart data.&nbsp;
+
The fifth section is the&nbsp;'''Actions'''. This section defines what actions should be taken after the out-of-control exception is triggered.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 55: Choose Specific Version'''
+
'''Figure 39:&nbsp;Actions'''
  
[[File:Choose Specific Version.png|500px|Choose Specific Version.png]]
+
[[File:SPC Actions.png|700px|SPC Actions.png]]
  
 
&nbsp;
 
&nbsp;
  
'''Note''': The Current SPC allows the user to choose a specific version to display FPY chart.
+
*'''Send alert e-mail''': This action sends an alert email to a specific&nbsp;person. Users can specify who would receive these alert emails in the Email Maintenance&nbsp;module.
 +
*'''Change the background color to red''': If the exception was triggered, the background of the associated data record in this monitor will turn red.  
 +
*'''Send MFG hold request after n minutes''': This action is an '''SPC line stopper''' function. To enable this action, the following options must first be enabled:
  
&nbsp;
+
#'''Send MFG Hold request to&nbsp;MDS''' checkbox in Add/Edit Monitor group page.
 +
#'''Pareto Chart''' checkBox in Other Control Charts&nbsp;section.
 +
#'''Create an Exception when n1 defect code of the same type within n2 minutes''' checkbox in the Other Control Charts&nbsp;section.
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Other_Control_Chart"><span class="mw-headline" id="Other_Control_Chart"><span class="mw-headline" id="Other_Control_Chart"><span class="mw-headline" id="Other_Control_Chart"><span class="mw-headline" id="Other_Control_Chart"><span class="mw-headline" id="Other_Control_Chart"><span class="mw-headline" id="Other_Control_Chart"><span class="mw-headline" id="Other_Control_Chart">Other Control Chart</span></span></span></span></span></span></span></span> ===
+
If '''Send MFG hold request after n minutes''' checkbox is enabled and if n1 defect code of the same type is scanned via NetDC within n2 minutes, SPC will send an MFG hold request to SFDC / MDS after n minutes. If the input minutes is 0, SPC will send the MFG hold immediately.
  
The fourth section is the Other Control Chart. The components of this section are as follows:
+
<u>'''Note:'''</u>&nbsp;This checkbox is not selected by default.&nbsp;Line stopper in SPC supports hold by part number + Location/process based on monitor selection.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 56: Other Control Chart'''
+
Lastly, remember to click [[File:Save button.png|save button]]&nbsp;to save all the configurations before you leave the page, or click [[File:Cancel.button.png|cancel.button]] button if you want to give up the configuration and return to the Monitor List page.
  
[[File:SPC Other Control Chart.png|700px|Other Control Chart]]
+
&nbsp;
 +
 
 +
&nbsp;
  
'''DPMO Chart''': Enables SPC to monitor a manufacturing line with a DPMO chart. '''Defect opportunity'''&nbsp;and '''UCL'''&nbsp;represent the two parameters used for defining DPMO charts.
 
  
'''Note''': The other 4 charts are custom made by the company according to the specific defect code. For example:<br/> '''DPMO-Placement Chart''': Placement is a defect code name. The chart is only for this defect code. The other 3 charts are the same.
+
== <span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor">Search Monitor</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;
+
The Search Monitor&nbsp;portlet makes it very convenient to find a specific monitor from the monitor's list. You can find this function in the toolbar on the&nbsp;'''Monitor List'''&nbsp;page.
  
'''Figure 57: DPMO Chart Types'''
+
'''Figure 40: Search Monitor'''
  
[[File:DPMO Chart Types.png|700px|DPMO Chart Types.png]] &nbsp;
+
[[File:SPC searchmonitor.png|900px|SPC searchmonitor.png]]
  
'''Yield Chart''''': ''Enables SPC to monitor the manufacturing line with the Yield chart. The Limit''''&nbsp;'''is a parameter used for defining the Yield chart.
+
<br/> Users can search monitor by'''&nbsp;Monitor Name, Location, Process, Location By Family, Part Number Family ID, Batch ID, '''and '''Monitor''''''&nbsp;Status.&nbsp;'''
  
'''Pareto Chart''': Enables SPC to monitor the manufacturing line with a Pareto chart. Users can define a Pareto chart exception rule by selecting the '''Create exception when''' checkbox and entering, for example, 3 '''defect code of the same type within''' 10 '''minutes'''.&nbsp;
+
Once search criteria have been selected and entered, select '''Search''' to execute the search action.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 58:&nbsp;Create Exception When''' '''Fields'''
+
=== <span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors">Hide Inactive Monitors</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:Create Exception When.png|700px|Create Exception When.png]]
+
It allows the user to filter out those monitors that have no new data coming in during the past settable hours. The user can define the settable hours in the SPC System Parameter Maintenance&nbsp;module, and view active monitors on the Monitor List page.
 +
 
 +
It can turn off the filtering inactive monitors function. This option is at the bottom of the screen.
  
 
&nbsp;
 
&nbsp;
 
For Continuous control charts, the available control charts are described below:&nbsp;
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 59: Available Control Charts for Continuous control charts'''
+
==== <span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours">View Active Monitors by Default Hours</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
[[File:SPC Available Control Charts for Continuous control charts.png|Available Control Charts for Continuous control charts]]
+
In the&nbsp;'''Monitor List'''&nbsp;page, the checkbox '''Hide monitors with no data in chart in the past(hours)'''&nbsp;are selected by default along with a textbox displaying the hours defined in the SPC System Parameter Maintenance&nbsp;module. The SPC system filters out those inactive monitors that meet the condition.
  
The&nbsp;Calculation by&nbsp;field in the'''Cpk / Ppk '''chart settings has two available options:&nbsp;'''All Data '''and '''Month'''. By default,&nbsp;'''All Data''' is selected.&nbsp;
+
'''Figure 41: Hide monitors with no data&nbsp;'''
  
'''All Data:''' SPC generates only one revision with all Cpk / Ppk chart&nbsp;attribute data.&nbsp;&nbsp;
+
[[File:SPC hidemnitorswithnodata.png|900px|SPC hidemnitorswithnodata.png]]
  
'''Month: '''The Cpk / Ppk chart data collection duration for this monitor will be based on a natural full month.&nbsp;
+
'''<u>Note:</u> '''Users can Edit Settable Hours and also '''Disable Hide Inactive Monitors Function.&nbsp;'''
  
The '''Method''' '''of Std Dev(within)''' &nbsp;in the cpk/ppk chart has three available options:&nbsp;'''Pool standard deviation, Rbar, and Average moving range.'''
+
*Edit the hour’s textbox value and select '''Input''' to view corresponding monitors. The value allowed in this textbox is a positive integer between 1 to 168. Modification of the value here does not affect the value defined in&nbsp;the SPC&nbsp;System Parameter Maintenance&nbsp;module.&nbsp;  
 +
*Unchecking the'''Hide monitors with no data''' '''in the chart in the past(hours) '''box deactivates the monitor filtering function so that the SPC system shows all existing monitors.&nbsp;
  
The method used to&nbsp;'''Std Dev(within) '''depends on the subgroup size.
+
'''Edit Monitor&nbsp; (Edit Monitor in Batch)'''
  
When '''subgroup size > 1, '''SPC estimates '''Std Dev(within) using one of the following two methods: Pooled standard deviation and Average of subgroup ranges (Rbar), SPC select Pooled standard deviation method by default.'''
+
SPC allows users to modify the parameters of an existing monitor according to their needs. Users can modify sections including Interval, Rules, Available charts, Other control charts, and Actions. To edit monitors, they must be '''stopped'''.
  
'''When subgroup size = 1, SPC estimates Std Dev(within) using the Average moving range method.'''
+
#Select a monitor in the same batch from the monitor list on the '''‘Monitor List’ '''page, then hit the '''Edit''' icon in the toolbar.
  
'''Xbar-R Chart''': X-bar and R (range) chart is a pair of control charts used with processes that have a subgroup size of two or more.&nbsp;
+
'''Figure 42:&nbsp;Monitor List - Edit a Single Monitor'''
  
'''I-MR''' Chart I-MR chart is a combination of two charts (Individual and Moving Range) is to track the process variability based on the samples taken from a process over the period of time. An Individual moving range (I-MR ) chart is used when data is continuous and not collected in subgroups.
+
[[File:SPC editasinglemonitor.png|900px|SPC editasinglemonitor.png]]
 +
<ol start="2">
 +
<li>Modify the preferred available information.&nbsp;</li>
 +
</ol>
  
&nbsp;
+
Note that the '''Monitor''' tab is not allowed to be modified. Update the other tabs information accordingly.
  
See below description and samples of the main available charts at SPC:
+
'''Figure 43: Edit Monitor Page'''
  
&nbsp;
+
[[File:SPC EditMonitorPage.png|700px|SPC EditMonitorPage.png]]
  
'''Pareto Chart'''
+
'''Data Collection Strategy '''can also be edited.
  
Preto chart indicates which problem to tackle first by showing the proportion of the total problem that each of the
+
'''Figure 44: Edit Monitor Page - Data Collection Strategy'''
  
smaller problems comprises. It is a type of chart that contains both bars and a line graph, where individual values
+
[[File:SPC aDataCollectionStrategy.png|700px|SPC aDataCollectionStrategy.png]]
 +
<ol start="3">
 +
<li>Select '''Save'''&nbsp;to save all modifications before leaving the page.&nbsp;</li>
 +
</ol>
  
are represented in descending order by bars, and the cumulative total is represented by the line.
+
'''<u>Note:</u> '''If the Data Collection Strategy selected is Manual Collection via SPC UI, the user can also modify the '''Attributes'''&nbsp;values.
  
 
&nbsp;
 
&nbsp;
 
'''Figure 60: Pareto Chart'''
 
 
[[File:SPC Pareto Chart.png|700px|Pareto Chart]]
 
  
 
&nbsp;
 
&nbsp;
  
'''C-Chart'''
+
== <span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29">Edit Monitor (Edit Monitor in Batch)</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
C-chart is an attribute control chart used with data collected in subgroups that are the same size.&nbsp;
+
In the main menu, the user must choose&nbsp;'''Batch ID '''from the search engine and select the monitors in the batch to edit, and then click the '''Edit''' icon in the toolbar.
  
It shows how the process, measured by the number of nonconformities per item or group of items, changes over time. Nonconformities are defects or occurrences found in the sampled subgroup. They can be described as any characteristic that is present but should not be or any characteristic that is not.
+
'''Figure 42: Monitor List - Edit Monitors in Batch'''
  
&nbsp;
+
[[File:SPC editmonitorsinbatch.png|900px|SPC editmonitorsinbatch.png]]
  
'''Figure 61: C Chart'''
+
'''Figure 43: Edit Monitor Page'''
  
[[File:SPC C Chart.png|700px|C Chart]] &nbsp;
+
[[File:SPC editmonitorpage.png|900px|SPC editmonitorpage.png]]
 
+
<ol start="2">
'''P-Chart'''
+
<li>&nbsp;Modify the preferred available information. Note that the Monitor tab is not allowed to be modified. Update the other tabs information accordingly.&nbsp;</li>
 +
</ol>
  
P-chart is an attribute control chart used with data collected in subgroups of varying sizes. Because the subgroup size can vary, it shows a proportion on nonconforming items rather than the actual count. P-charts show how the process changes over time.
+
'''<u>Note:</u> '''If the Data Collection Strategy selected is Manual Collection via SPC UI, the user can also modify the Attributes&nbsp;values.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 62: P Chart'''
 
  
[[File:SPC P Chart.png|700px|P Chart]]
+
== <span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor_.2F_Delete_Monitor_in_Batch">Delete Monitor / Delete Monitor in Batch</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;
+
If users no longer need a monitor or monitor in batch and want to remove it, the monitor can be deleted.&nbsp;
  
'''NP-Chart'''
+
'''Note that once a monitor is deleted from SPC, it cannot be restored, and this is permanent.&nbsp;'''
  
NP-chart is an attribute control chart used with data collected in subgroups that are the same size. NP-charts show how the process, measured by the number of nonconforming items it produces, changes over time.
+
To delete a monitor:
  
'''Figure 63: NP Chart'''
+
#Check the box of the monitor to be deleted, and select '''Disable''' to disable the monitor first.
 +
#Once the monitor is disabled, locate the monitor in the disabled monitor list and check the box of the monitor to select it.
 +
#&nbsp;Click the '''DEL icon&nbsp;'''in the toolbar.
  
[[File:SPC NP Chart.png|700px|NP Chart]]
+
'''Figure 47: Function List - Delete'''
  
&nbsp;
+
[[File:SPC functionlistdelete.png|900px|SPC functionlistdelete.png]]
  
'''U-Chart'''
+
4. Choose '''Yes''' in the pop-up window.
  
U-chart is an attribute control chart used with data collected in subgroups of varying sizes. U-charts shows how the process, measured by the number of nonconformities per item or group of items, changes over time.
+
<u>To delete a monitor in batch:</u>
  
<br/> &nbsp;
+
#Search for the Batch ID and select the monitors in the batch to be deleted.
 +
#Check the box of the monitors to be deleted and select Disable to disable the monitors first.
 +
#Once the monitors are disabled, check the box of the monitors to select them.
 +
#Click the '''DEL icon'''&nbsp;in the toolbar.
 +
#Then choose '''Yes''' in the pop-up window
  
'''Figure 64: U Chart'''
+
&nbsp;
  
[[File:SPC U Chart.png|700px|U Chart]]
 
  
&nbsp;
+
== <span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Disable.2C_Enable.2C_Delete_Monitor">Disable, Enable, Delete Monitor</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
'''XBar-Chart'''
+
SPC supports automatic start monitors to simplify the application use process, this will greatly reduce maintenance costs
  
X-bar and R (range) chart is a pair of control charts used with processes that have a subgroup size of two or more.&nbsp;
+
Engineers only need to create monitors when they have a new product or disable/delete monitors after the product has been EOL. Even keeping a large number of Enabled monitors will not affect SPC performance.
 
 
The standard chart for variables data, X-bar, and R charts help determine if a process is stable and predictable. The X-bar chart shows how the mean or average changes over time and the R chart shows how the range of the subgroups changes over time.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 65: XBar Chart'''
+
'''Figure 48: Scenarios'''
  
[[File:SPC XBar Chart.png|700px|XBar Chart]]
+
[[File:Monitor m.png|700px|Monitor m]]
  
 
&nbsp;
 
&nbsp;
  
'''R-Chart'''
+
&nbsp;
  
The X-bar chart shows how the mean or average changes over time and the R chart shows how the range of the subgroups changes over time.
+
=== <span class="mw-headline" id="Enable_monitor"><span class="mw-headline" id="Enable_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor">Enable&nbsp;monitor&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
'''Note''': LCL can’t be negative. Both S (Standard Deviation) and R (Range) can't be negative, because by the nature. All the points that the user scans are displayed on the chart and when expanding chart details, all the information in the chart page is collected such as SPC Collection time, Average, LCL, UCL, OCAP, attributes, etc. and There are no negative numbers on Y-axis.
+
&nbsp; To enable a disabled monitor&nbsp;
  
&nbsp;
+
#Find the disabled monitor in the list and check the box for that monitor.&nbsp;
 +
#Click the Enable icon in the toolbar.&nbsp;  
  
'''Figure 66: R Chart'''
+
'''Figure 49: Function List - Enable'''
  
[[File:SPC R Chart.png|700px|R Chart]]
+
[[File:SPC funtionlistenable.png|900px|SPC funtionlistenable.png]]
  
'''Yield -Chart'''
+
Users can search enabled monitors using the search function by selecting Enabled from the monitor status drop-down list and clicking the&nbsp;'''Search icon.'''
  
This chart shows the Yield value for a selected or retrieved process, one at a time, and a list of the N last products passed on this process.
+
&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 67: Yield Chart'''
+
=== <span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor"><span class="mw-headline" id="Disable_Monitor">Disable Monitor&nbsp;&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:SPC Yield Chart.png|700px|Yield Chart]]
+
After a new monitor is created, its status is Started by default. The monitor's data is automatically collected from MDS.&nbsp;
  
&nbsp;
+
If a user does not need a monitor to operate, the user can disable the monitor.&nbsp;
 +
 
 +
#To disable a monitor, check the box of the monitor.&nbsp;
 +
#Select the '''Disable''' icon to disable the monitor.
  
'''FPY-Chart'''
+
'''Figure 50: Function List - Disable'''
  
FPY is a First Pass Yield:&nbsp;
+
[[File:SPC disablemonitor.png|900px|SPC disablemonitor.png]]
  
*Capable of plotting the First Pass Yield of a product at a particular process step over a period of time or number of boards.
+
Users can search for disabled monitors using the search function by selecting Disabled from the monitor status drop-down box and clicking the'''Search icon.&nbsp; &nbsp;'''
*Capable of manual configure the upper control limit and lower control limit.  
 
*Can displays the target (Goal) line
 
*Capable to use the 7 Rule alarms for triggering
 
*Capable to trigger the alarm when FPY falls below the Target Line
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 68: FPY Chart'''
 
  
[[File:SPC FPY Chart.png|700px|FPY Chart]]
+
== <span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History">View Monitor History&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;
+
&nbsp;To view the modification history of a monitor:
  
'''CPK/PPK-Chart'''
+
#Go to the Monitor List page, select a monitor, and click the '''REV icon.'''  
  
CPK/PPK is to show if the real process capability meets the specification
+
'''Figure 51: Monitor List - Rev Icon'''
  
Definitions
+
[[File:SPC monitorlistrevicon.png|900px|SPC monitorlistrevicon.png]]
  
&nbsp;Cp= Process Capability. A simple and straightforward indicator of process capability.
+
== <span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor">Manually Input Data to Monitor&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;Cpk= Process Capability Index. Adjustment of Cp for the effect of non-centered distribution.
+
To date, the SPC monitor supports three data collection strategies: '''Automic Collection From Unit Attributes''', '''Manual Collection via SPC UI''', and '''Automic Collection''' via '''SPC API''', which can be configured in the Data Collection Strategy&nbsp;section. If ‘manual collection via SPC UI’ is selected as a '''data collection strategy''', data must be manually entered after the monitor is created.&nbsp; &nbsp;
  
&nbsp;Pp= Process Performance. A simple and straightforward indicator of process performance.
+
&nbsp;
  
&nbsp;Ppk= Process Performance Index. Adjustment of Pp for the effect of non-centered distribution.
+
&nbsp;
  
Cpk is for the short term, Ppk is for the long term.
 
  
Cp and Cpk
+
=== <span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor">Input Data for Only One Monitor&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
It is common to express process capability in terms of:
+
To enter data for one monitor: From the Monitor List screen, select the monitor that needs to manually input data (the ‘Collection Type’ value of this monitor is ‘Manual’), and then click the&nbsp;'''Input icon.'''
  
*How well can we meet customer’s specification?
+
'''Figure 52: Monitor List - Input'''
*Voice of Customer / Voice of the process
 
*It is a potential capability index - Cp is defined as:
 
  
&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp; Cp = USL – LSL/6σst
+
[[File:SPC monitorlistInput.png|900px|SPC monitorlistInput.png]]
  
The minimum acceptable value for Cp is normally considered to be 1
+
In the '''Collect New Data '''page, input attributes data to correspondent fields.&nbsp;
  
Cpk = Min (USL- x, x – LSL)/3σst
+
'''Figure 53: Input - Collect New Data&nbsp;'''
  
When there is no shift or drift, Cpk and Cp are equal. As the process drifts, Cpk gets smaller.&nbsp;
+
'''[[File:SPC CollectNewData.png|900px|SPC CollectNewData.png]]'''
  
 
&nbsp;
 
&nbsp;
  
'''Pp and Ppk Chart'''
+
&nbsp;
  
Over time, the drift in the process will have the effect of ‘flattening out’ the distribution, and the standard deviation of the process will increase.&nbsp; To reflect this effect properly, we define two long term capability indices, Pp and Ppk.
+
&nbsp;
  
These indices have the same formulas as their short term counterparts, but use the long term standard deviation in their denominators, σlt
 
  
Pp = USL – LSL/ 6σlt &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Ppk = Min (USL- x, x – LSL)/3σlt
+
=== <span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once">Input Data for Multiple Monitors At Once</span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
'''Figure 69: CPK/PPK Chart'''
+
&nbsp; Users can select and input data to multiple monitors at once, as long as all of the selected monitors' Collection Type is Manual.
  
[[File:SPC Figure69 CPKPPKChart.png|700px|File:SPC Figure69 CPKPPKChart.png]]
+
'''Figure 54: Monitor List - Collection Type Column'''
  
&nbsp;
+
[[File:SPC collectiontype.png|900px|SPC collectiontype.png]]
  
=== <span class="mw-headline" id="Available_Charts_2"><span class="mw-headline" id="Available_Charts"><span class="mw-headline" id="Available_Charts_2"><span class="mw-headline" id="Available_Charts_2"><span class="mw-headline" id="Available_Charts_2">Available Charts</span></span></span></span></span> ===
+
'''<u>Note:</u> '''If users have selected monitors that contain at least one monitor whose Data Collection Type is not Manual, and click Input, users will be prompted by an alert window saying ''''You have selected at least one monitor that is not for manual data collecting. Please check and try again.' '''Close the alert window by clicking '''Ok'''.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
The following section is the&nbsp;AvailableCharts, which contains three sub-sections: Available Control Charts, DPMO, and Other charts.&nbsp;
+
==== <span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_the_Current_Monitor">Input Attributes for the Current Monitor&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
&nbsp;
+
On the Collect New Data page, users can enter attributes for multiple monitors at once. The Monitor drop-down list will display the currently selected monitor to input data. Users can view the Line, Monitor Name, and Location of the current monitor in the top left corner. Note that the allowed input of attributes is number only.
  
&nbsp;
+
<u>'''Note 1:'''</u> If users have input values in at least one of the fields and select Reset, an alert window will display with the warning message''', 'You are about to reset all values. This action will delete all values of the current monitor. Are you sure you want to proceed?'''' Selecting Yes resets all entries for the current monitor to the default value.&nbsp;
  
=== <span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions"><span class="mw-headline" id="Actions">Actions&nbsp;&nbsp;</span></span></span></span></span> ===
+
<br/> <u>'''Note 2:'''</u> If users have input values set to at least one of the fields, and select another monitor from the Monitor drop-down list, an alert window will display with the warning message, ''''The data for the current monitor has not been saved yet. Are you sure you want to go to another monitor?'''' Selecting Yes will redirect the user to another monitor without the current monitor's data stored in the SPC system.&nbsp;
  
The fifth section is the&nbsp;'''Actions'''. This section defines what actions should be taken after the out-of-control exception is triggered.
+
<br/> <u>'''Note 3:'''</u> If users have input values to at least one of the fields and select the '''New Record button''', an alert window displays with a warning message, ''''You are about to cancel the attribute data entering. The current monitor will have no attributes recorded. Are you sure you want to proceed?'''' Selecting Yes will move a user to the Monitor List page without the current monitor's data stored in the SPC system.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 70:&nbsp;Actions'''
+
==== <span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_the_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_current_monitor.27s_attributes_data">Save the current monitor's attributes data&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
[[File:Actions section.png|Actions section.png]]
+
In the '''Collect New Data '''page, if a user has finished inputting data to the current monitor, and selects Save, all the current monitor fields turn grey except the Monitor drop-down list and the user cannot edit any data. The current monitor name in the Monitor drop-down box changes to 'monitor_name (Saved)' where monitor_name is the name of the current monitor. Now the user can switch to another monitor to input attribute data to that monitor.&nbsp;
  
<br/> '''Send alert e-mail''': This action sends an alert email to a specified person. Users can specify who would receive these alert emails in the Email Maintenance&nbsp;module.
+
&nbsp;
  
<br/> '''Change the background color to red''': If the exception was triggered, the background of the associated data record in this monitor will turn to red.
+
==== <span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor">Switch to Another Monitor&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
<br/> '''Send MFG hold request after n minutes''': This action is an '''SPC line stopper''' function. To enable this action, the following options must first be enabled:
+
To switch to another monitor to input attributes, click the Monitor drop-down box and select another monitor from the list.&nbsp;
  
#'''Send MFG Hold request to SFDC / MDS''' checkbox in Add Server Information page.
+
== <span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API"><span class="mw-headline" id="Automatic_Collection_via_SPC_API">Automatic Collection via SPC API&nbsp;</span></span></span></span></span></span></span></span></span></span></span> ==
#'''Pareto Chart''' checkBox in Other Control Charts&nbsp;section.
 
#'''Create an Exception when n1 defect code of the same type within n2 minutes''' checkbox in the Other Control Charts&nbsp;section.
 
  
&nbsp;
+
The'''Automatic Collection via SPC API'''&nbsp;method allows the users to create a monitor with Automatic Collection Via SPC API type, the clients (such as PWB) or other third-party applications to push the data to SPC via its monitor API as long as the characteristics in the parameters of the API endpoint exist and match this monitor, the continuous data control charts (such as X bar-R chart, I-MR chart, and CPK/PPK report) will plot with SPC. &nbsp;
  
If '''Send MFG hold request after n minutes''' checkbox is enabled and if n1 defect code of the same type were scanned via NetDC within n2 minutes, SPC will send an MFG hold request to SFDC / MDS after n minutes. If the input minutes is 0, SPC will send the MFG hold immediately.
+
=== <span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario"><span class="mw-headline" id="Scenario">Scenario</span></span></span></span></span></span></span></span></span></span></span> ===
  
NOTE:&nbsp;This checkbox is not selected by default.&nbsp;Line stopper only supports&nbsp;part number. So if a user selects a&nbsp;'''Family ID'''&nbsp;in the Monitor&nbsp;section, this option will not be available.
+
One plant needs to measure the thickness of its products multiple times during a process that can take days. They measure the thickness every 1/2 to 1 hour. They need to collect the thickness using Production Workbench as this is the interface the Operators use for the entire manufacturing process. Every thickness measurement collected via Production Workbench should be displayed on the SPC chart in near real time not only when the unit (non-serialized batch) moves from the location via terminator command.
  
&nbsp;
+
SPC shall display all records collected via PWB attributes in “near real time”. This shall occur upon submission without regard to if we are in the middle of the process or at the end of the process moving to the next location.
  
Lastly, remember to click [[File:Save button.png|save button]]&nbsp;to save all the configurations before you leave the page, or click [[File:Cancel.button.png|cancel.button]] button if you want to give up the configuration and return to the Monitor List page.
+
The customer does not desire to use another user interface (SPC, Measurement, custom, etc) to collect the data. The operators will be working in PWB only at the terminal. (Thin terminals are to be used.) &nbsp; The following will take the Production Workbench sending attribute values to SPC via SPC API as an example to explain the work process step by step.
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
 
  
== <span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor"><span class="mw-headline" id="Search_Monitor">Search Monitor</span></span></span></span> ==
 
  
The Search Monitor&nbsp;portlet makes it very convenient to find a specific monitor from the monitors list. You can find this function in the toolbar on the&nbsp;'''Monitor List'''&nbsp;page.
+
=== <span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step"><span class="mw-headline" id="Work_process_Step_by_step">Work process Step by step</span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
&nbsp;
+
To transmit data through the API, the SPC Token, Key, the Generic attribute needs to be set.&nbsp;
  
'''Figure 71:Search Monitor'''
+
*'''Step 1:''' Define the SPC Server information at the Server information.
  
[[File:Search Monitor.png|700px|Search Monitor]]
+
Navigate to: '''Administration > Server Information'''; add one SPC server information.
  
<br/> Users can search monitor '''by keyword''' and '''monitor status'''.
+
<u>'''Note:'''</u> Please select the SPC for the Program field.
  
'''By keyword''': Users can search existing monitors according to a keyword by first clicking the keyword drop-down box (the green framed area in Figure 43 and selecting a category. A corresponding can then enter a keyword in the adjacent textbox.
+
*'''Step 2:''' Define the generic attribute form at the '''Generic Attribute Maintenance(MDS) module''' that allows the production workbench to call the SPC API to send attribute data to SPC.  
  
'''By monitor status''': Users can search monitor by monitor status. Users must select a monitor status from the status categories drop-down list.
+
&nbsp;Navigate to: '''Administration > Generic Attribute Maintenance(MDS)'''; add one Generic Attribute information.&nbsp;&nbsp;&nbsp;
  
&nbsp;
+
<u>'''Note:'''</u> Please select '''spc_service_host''' for the '''Attribute Name''' field and '''Project''' for the '''Table''' field. And the '''Value''' is the SPC Host: '''SPC AppServer Port '''(The SPC Server defined at the server information).
  
Once search criteria have been selected and entered, select &nbsp;[[File:Search-icon.png|search icon]] to execute the search action.
+
*'''Step 3:''' Create a Monitor, select the'''Automatic Collection''' via SPC API at the '''Data Collection Strategy '''tab.  
  
&nbsp;
+
And add the '''attributes''' to the '''Characteristics''' list.
 +
 
 +
<u>'''Note:'''</u> The Characteristics must be the same as the attributes used/scanned at '''Production Workbench.'''
  
== <span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors"><span class="mw-headline" id="Hide_Inactive_Monitors">Hide Inactive Monitors</span></span></span></span> ==
+
<br/> '''Figure 55:&nbsp; Create a Monitor Automatic Collection via SPC API'''
  
It allows you to filter out those monitors that have no new data coming in during the past settable hours. You can define the settable hours in the SPC System Parameter Maintenance&nbsp;module, and view active monitors in the Monitor List page. Besides, you can turn off the filtering inactive monitors function.
+
'''[[File:SPC AutomaticCollectionviaSPCAPI.png|700px|SPC AutomaticCollectionviaSPCAPI.png]]'''&nbsp;&nbsp;
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours"><span class="mw-headline" id="View_Active_Monitors_by_Default_Hours">View Active Monitors by Default Hours</span></span></span></span> ===
+
*'''Step 4:''' Input/Scan the Serial number at the Production Workbench application.
  
In the&nbsp;'''Monitor List'''&nbsp;page, the checkbox '''Hide monitors with no data in chart in the past(hours)'''&nbsp;are selected by default along with a textbox displaying the hours defined in the SPC System Parameter Maintenance&nbsp;module. The SPC system filters out those inactive monitors that meet the condition.
+
To transmit the values of the attributes to SPC via the SPC API, the users select the command. e.g. '''Record Monitored Measurement.'''
  
&nbsp;
+
After inputting the command, some fields will show:
  
'''Figure 72: "Hide monitors with no data in the chart..." Checkbox'''
+
'''SPC Monitor Name?:&nbsp;'''Input the SPC monitor name. The Monitor Name must be the monitor that is created in step 3.
  
[[File:Hide monitors.png|700px|hide monitors.png]]
+
'''Attribute Name?: '''Input the Attribute name. The Attribute Name must be the Characteristics that are defined in the Data Collection Strategy tab.
  
&nbsp;
+
'''Attribute Value?: '''Input the attribute value. The value will be transmitted to SPC via SPC API even if the user doesn’t input the terminator/end command. The user can view the chat on the monitor in real-time. e.g. The input value 99 will show on the monitor chart.
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Edit_Settable_Hours"><span class="mw-headline" id="Edit_Settable_Hours"><span class="mw-headline" id="Edit_Settable_Hours"><span class="mw-headline" id="Edit_Settable_Hours">Edit Settable Hours</span></span></span></span> ===
+
'''Figure 56: Production Workbench'''
  
Edit the hours' textbox value and select '''Input&nbsp;'''to view corresponding monitors. The value allowed in this textbox is a positive integer between 1 to 168. Modification of the value here does not affect the value defined in&nbsp;the SPC<span style="line-height: 1.5em;">&nbsp;System Parameter Maintenance&nbsp;</span><span style="line-height: 1.5em;">module.</span>
+
&nbsp; [[File:SPC2.png|border|900px|Monitor List - New Record]]
  
 
&nbsp;
 
&nbsp;
  
'''Figure 73: Edit Settable Hours'''
+
*'''Step 5: '''The users can view the charts (attribute values) at the monitor charts.
  
[[File:Edit Settable Hours1.png|700px|Edit Settable Hours1]]
+
Select the monitor, then select the '''Chart''' to view the chart.
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Disable_Hide_Inactive_Monitors_Function"><span class="mw-headline" id="Disable_Hide_Inactive_Monitors_Function"><span class="mw-headline" id="Disable_Hide_Inactive_Monitors_Function"><span class="mw-headline" id="Disable_Hide_Inactive_Monitors_Function">Disable Hide Inactive Monitors Function</span></span></span></span> ===
+
'''Figure 57: Monitor Chart menu.'''
  
Unchecking the '''Hide monitors with no data in chart in the past (hours)''' box deactivates the monitor filtering function so that SPC system shows all existing monitors.
+
&nbsp; [[File:SPC3.png|border|900px|Monitor List - New Record]]
  
 
&nbsp;
 
&nbsp;
  
'''Figure 74:&nbsp;"Hide monitors with no data in the chart..." Checkbox Unselected'''
+
'''Figure 58: Attribute value on the Chart'''
  
[[File:Hide monitors with no data in char.png|700px|Hide monitors with no data in char.png]]
+
&nbsp; [[File:SPC4.png|border|900px|Monitor List - New Record]]
  
 
&nbsp;
 
&nbsp;
Line 1,211: Line 1,177:
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29"><span class="mw-headline" id="Edit_Monitor_.28Edit_Monitor_in_Batch.29">Edit Monitor (Edit Monitor in Batch)</span></span></span></span> ==
 
  
SPC allows users to modify the parameters of an existing monitor according to their needs. Users can modify sections including Interval, Rules, Available charts, Other control charts, and Actions. to edit monitors, they must be'''stopped'''.
+
== <span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP">View Control Chart, Data & Write OCAP</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
&nbsp;
+
Control Chart is a very important tool for SPC to monitor the manufacturing line. Through the analysis of control charts, users can learn whether a manufacturing line or process is under control and determine the reasons for an out-of-control exception, so that they can take appropriate measures. To date, our SPC system supports 6 control charts: C chart, U chart, P chart, NP chart,&nbsp;X Bar-R chart, I-MR chart, and also supports 5 other charts: DPMO chart, FPY chart, Yield chart, Pareto chart, and Cpk / Ppk chart.
  
#Select a monitor from the monitor list in the ‘Monitor List’ page, then hit the [[File:Edit-icon.png|edit icon]] icon in the toolbar.  
+
The SPC development team applies Ext JS technology, other than the old Jfreechart technology to all of the 11&nbsp;charts. The Ext JS technology enables SPC to represent more interactions with the user from the UI perspective. For instance, a user can view more information about a chart point by hovering their cursor over the point. Also, users can view both SPC charts and data on the same page without having to open them on different pages.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 75: Monitor List - Edit Monitor Page'''
+
&nbsp;
 
 
[[File:Monitor List - Edit Monitor Page.png|700px|Monitor List - Edit Monitor Page]]
 
  
 
&nbsp;
 
&nbsp;
<ol start="2">
 
<li>From the Edit Monitor page, modify the preferred available information.&nbsp;</li>
 
</ol>
 
  
Note that the Monitor tab and Data Collection Strategy tab are not allowed to be modified. Update the other tabs' information accordingly.
+
=== <span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart">View Control Chart</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
&nbsp;
+
Here take the C chart as an example to demonstrate how to view the control chart with the Ext JS technology enhancement. The operation of other control charts is similar to the C chart below.
  
'''Figure 76: Edit Monitor Page'''
+
#To SPC view the control chart, from the Monitor List page, select a monitor and click the [[File:Chart-button.png|chart button]]&nbsp;icon in the toolbar. This displays the chart page.
  
[[File:Edit Monitor Page1.png|700px|Edit Monitor Page1]]
+
'''Figure 59: Function List - Chart'''
  
&nbsp;
+
[[File:SPC functionlistchart.png|900px|SPC functionlistchart.png]]<br/> <u>'''Note''':</u>&nbsp;On the top of the page users&nbsp;will see a few brief pieces of information on the control chart, such as&nbsp;monitor name, part number, and&nbsp;location. The family ID can also be displayed here if the Display Family ID is checked in the SPC Portal System Parameter&nbsp;module.
  
&nbsp;
+
To view any chart, users have to choose it from the available chart listed on the drop-down list at the top of the page, and then select a revision, click '''Retrieve''' and SPC will generate the chart according to the parameters used.
<ol start="3">
 
<li>Select [[File:Save button.png|save button]] to save all modifications before you leave the page.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Note''': If the Data Collection Strategy selected is Manual Collection via SPC UI, a user can also modify the '''Attribute'''&nbsp;values.
+
'''Figure 60: Chart Retrieve'''
  
&nbsp;
+
[[File:SPC ChartRetrieve.png|900px|SPC ChartRetrieve.png]]
  
== <span class="mw-headline" id="Edit_Monitor_in_Batch"><span class="mw-headline" id="Edit_Monitor_in_Batch"><span class="mw-headline" id="Edit_Monitor_in_Batch"><span class="mw-headline" id="Edit_Monitor_in_Batch">Edit Monitor&nbsp; in Batch</span></span></span></span> ==
+
<br/> '''[[File:Lightbulb icon.png|60px|Lightbulb icon.png]]Tips''':
  
#Search for the Batch ID and select the monitors in the batch to edit and then hit the [[File:Edit icon.png|edit icon]] in the toolbar.  
+
#On the Chart, blue points are normal points, red points are exception points, green points are exception points that have been written OCAP.
 +
#If you move the cursor over a point in the chart, a pop-up window will be prompted showing more information about&nbsp;the selected point, including '''SPC Collection Time''', '''Inspected''', '''Defects''' and '''Cause'''. Note that control charts vary in more information about&nbsp;a selected point.
 +
#If you click a point on the chart, the corresponding data line in the data list will be highlighted; if you select a data line from a data list, the corresponding point on the chart will be highlighted as well.
 +
#The red background of a data line means that this data item has violated the rules you defined in the '''Rules''' section, and the OCAP of this data record has not been processed yet; the green background of a data line indicates that OCAP of this data record has been processed.
 +
#This data list table structure consists of 9 columns: SPC Collection Time, Inspected, Defects, UCL, LCL, OCAP, OCAP History, Cause and Affected S/Ns.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 77: Monitor List - Edit Monitors in Batch'''
+
'''Figure 61: C-Chart Information Points'''
  
[[File:SPC Monitor List - Edit Monitors in Batch.png|700px|Monitor List - Edit Monitors in Batch]]
+
[[File:SPC ChartInformationPoints.png|900px|SPC ChartInformationPoints.png]]
  
 
&nbsp;
 
&nbsp;
  
'''Figure 78: Batch Edit Monitor page'''
+
&nbsp;
  
[[File:SPC Batch Edit Monitor page.png|700px|Batch Edit Monitor page]]
+
==== <span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP">Write OCAP</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
&nbsp;
+
To write OCAP, means to write something about the fix to the exception. To do this:
<ol start="2">
 
<li>From the'''Edit Monitor''' page, modify the preferred available information.&nbsp;</li>
 
</ol>
 
  
Note that the Monitor tab and Data Collection Strategy tab are not allowed to be modified. Update the other tabs information accordingly.
+
#Select the [[File:Ocap-button.png|ocap button]] icon, then input the description of this OCAP in the pop-up OCAP windows.
 +
#Select&nbsp;[[File:Save-button.png|save button]]&nbsp;to save the change to SPC.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 79: Edit Monitor Page'''
+
'''Figure 62: OCAP&nbsp;Window'''
  
[[File:SPC Edit Monitor Page.png|700px|Edit Monitor Page]]
+
[[File:SPC OCAPWindow.png|900px|SPC OCAPWindow.png]]
<ol start="3">
 
<li>Select [[File:Save button.png|save button]] &nbsp;to save all modifications before leaving the page.&nbsp;</li>
 
</ol>
 
  
&nbsp;
+
<br/> If there are more than one unprocessed OCAPs after entering a description of the current OCAP, enable the '''Apply to previous OCAPs''' checkbox to apply the change to all the unprocessed OCAPs.
  
'''Note''': If the Data Collection Strategy selected is Manual Collection via SPC UI, the user can also modify the Attribute&nbsp;values.&nbsp;
+
After the OCAP is processed, the background of the associated data record will turn green.
 +
 
 +
=== <span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History">View OCAP History</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
 +
 
 +
Select [[File:Ocap-history.png|OCAP history button]]&nbsp;to view the OCAP history of a data record in the pop-up OCAP history window.
  
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor"><span class="mw-headline" id="Manually_Input_Data_to_Monitor">Manually Input Data to Monitor</span></span></span></span> ==
+
'''Figure 63: OCAP&nbsp;History'''
  
To date, the SPC monitor supports three data collection strategies: '''Auto Collection From SFDC''', '''Manual Collection Via SPC UI''' and '''Auto Collection from SPC Machine''', which can be configured in the Data Collection Strategy&nbsp;section. If ‘manual collection via SPC UI’ is selected as a data collection strategy, data must be manually entered after the monitor is created. Starting with version 3.2, SPC supports entering data once to both single and multiple monitors.
+
[[File:SPC OCAPHistory.png|900px|SPC OCAPHistory.png]]
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
==== <span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause">View Cause</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
 +
 
 +
Select&nbsp;[[File:Cause-button.png|cause button]]&nbsp;to view the rules that the current point has violated.
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor"><span class="mw-headline" id="Input_Data_for_Only_One_Monitor">Input Data for Only One Monitor</span></span></span></span></span> ===
+
'''Figure 64: Cause'''
  
To enter data for one monitor
+
[[File:SPC Cause.png|900px|SPC Cause.png]]
  
From the Monitor List screen, select the monitor that needs to be manually input data (the ‘Collection Type’ value of this monitor is ‘Manual’), and then click the&nbsp;[[File:Input-data-icon.png|input data icon]] icon.
+
&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 80: Monitor List - Input'''
+
==== <span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs">View Affected S/Ns</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ====
  
[[File:Monitor List-Input1.png|700px|Monitor List-Input1]]
+
Users can view the affected serial numbers and export them to an CSV&nbsp;file.
  
&nbsp;
+
#Select&nbsp;[[File:Affected-sn-button.png|affected S/Ns button]] to activate a pop-up window that displays the affected S/Ns list.  
 
 
On '''Collect New Data page''', input attributes data to correspondent fields.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 81: Input - Collect New Data Page'''
+
'''Figure 65: Affected Serial Numbers'''
  
[[File:Input - Collect New Data Page.png|700px|Input - Collect New Data Page]]
+
[[File:SPC AffectedSN.png|900px|SPC AffectedSN.png]]
  
 
&nbsp;
 
&nbsp;
 +
<ol start="2">
 +
<li>To export the affected S/Ns to an CSV file, click the [[File:Export-sn-icon.png|export affected S/Ns icon]] icon at the bottom of the Affected S/Ns window.</li>
 +
<li>Select the first option to export only one monitor, else, select the second option to export all monitors.</li>
 +
<li>Select the '''Export''' button.</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once"><span class="mw-headline" id="Input_Data_for_Multiple_Monitors_At_Once">Input Data for Multiple Monitors At Once</span></span></span></span></span> ===
+
'''Figure 66: Selecting The Monitors To Export'''
  
Users can select and input data to multiple monitors at once, as long as all of the selected monitors' Collection Type is Manual.
+
[[File:SPC Selecting The Monitors To Export.png|SPC Selecting The Monitors To Export.png]]
  
 
&nbsp;
 
&nbsp;
 +
<ol start="5">
 +
<li>Select '''Yes''' in the pop-up window to confirm the action.</li>
 +
</ol>
  
'''Figure 82: Monitor List - Collection Type Column'''
+
&nbsp;
  
[[File:Monitor List - Collection Type Column.png|700px|Monitor List - Collection Type Column]]
+
'''Figure 67: Confirm Export Alert'''
  
<br/> '''Note''': If a user has selected monitors that contain at least one monitor whose Data Collection Type is not Manual and clicks Input, he or she will be prompted by an alert window saying 'You have selected at least one monitor that is not for manually data collecting. Please check and try again.' Close the alert window by clicking Ok.&nbsp;
+
&nbsp;[[File:SPC Confirm Export Alert.png|SPC Confirm Export Alert.png]]
  
 
&nbsp;
 
&nbsp;
 +
<ol start="6">
 +
<li>Choose whether to open the XLS file or save it to the hard drive.</li>
 +
</ol>
  
'''Figure 83: Collection Data Type Alert Window'''
+
&nbsp;
  
[[File:Collection Data Type Alert Window.png|700px|Collection Data Type Alert Window]]
+
There is a reference link at the '''Defects''', that will show the Defect Code.
  
 
&nbsp;
 
&nbsp;
Line 1,347: Line 1,318:
 
&nbsp;
 
&nbsp;
  
==== <span class="mw-headline" id="Input_Attributes_for_The_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_The_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_The_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_The_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_The_Current_Monitor"><span class="mw-headline" id="Input_Attributes_for_The_Current_Monitor">Input Attributes for The Current Monitor</span></span></span></span></span></span> ====
+
'''Figure 68: Defect Message'''&nbsp;
  
On the Collect New Data page, users can enter attributes for multiple monitors at once. The Monitor drop-down list displays the currently selected monitor to be input data. Users can view Line, Monitor name, and Location of the current monitor on the top left the corner. Note that the allowed input of attributes is number only.
+
[[File:SPC DefectMessage.png|900px|SPC DefectMessage.png]]&nbsp;&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Note''': If a user has input values in at least one of the fields and selects Reset, an alert window displays with the warning message, 'You are about to reset all values. This action will delete all values of the current monitor. Are you sure you want to proceed?' Selecting Yes resets all entries for the current monitor to the default value.
+
&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 84: Collect New Data Page Reset - Alert Window'''
+
&nbsp;
  
[[File:Collect New Data Page Reset - Alert Window.png|700px|Collect New Data Page Reset - Alert Window]]
+
&nbsp;
  
<br/> '''Note''': If a user has input values set to at least one of the fields, and selects another monitor from the Monitor drop-down list, an alert window displays with the warning message, 'The data for the current monitor has not been saved yet. Are you sure you want to go to another monitor?' Selecting Yes will redirect the user to another monitor without the current monitor's data stored in the SPC system.
+
=== <span class="mw-headline" id="View_And_Edit_Data"><span class="mw-headline" id="View_And_Edit_Data"><span class="mw-headline" id="View_And_Edit_Data"><span class="mw-headline" id="View_And_Edit_Data"><span class="mw-headline" id="View_And_Edit_Data"><span class="mw-headline" id="View_And_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data">View And Edit Data</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
&nbsp;
+
Users can view detailed data of a monitor. To do this:
  
'''Figure 85: Collect New Data - Selecting a Different Monitor Alert Window'''
+
#Select a monitor and click the [[File:Data-icon.png|data icon]]&nbsp; icon in the toolbar in the&nbsp;'''Monitor List '''page.&nbsp;
  
[[File:Collect New Data - Selecting a Different Monitor Alert Window.png|700px|Collect New Data - Selecting a Different Monitor Alert Window]]
+
On the '''‘Data List’ '''page, set the time frame for the search by selecting the beginning date and ending date in the toolbar.
  
<br/> '''Note''': If users have input values to at least one of the fields and select the New Record button, an alert window displays with a warning message, 'You are about to cancel the attribute data entering. The current monitor will have no attributes recorded. Are you sure you want to proceed?' Selecting Yes will move a user to the Monitor List page without current monitor's data stored in the SPC system.
+
Select a status from the data status drop-down list and click the [[File:Search-icon.png|search icon]]&nbsp; icon to view the matching data.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 86: Collect New Data - New Record Alert Window'''
+
'''Figure 69: Data List - Automatically Collected Records'''
  
[[File:Collect New Data-New Record Alert Window1.png|700px|Collect New Data-New Record Alert Window1]]
+
[[File:SPC automaticallycollectedrecords.png|900px|SPC automaticallycollectedrecords.png]]
  
&nbsp;
+
<u>'''Note:'''</u> The user can click the Export icon to export the records to an CSV file.
  
 
&nbsp;
 
&nbsp;
  
==== <span class="mw-headline" id="Save_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_current_monitor.27s_attributes_data"><span class="mw-headline" id="Save_current_monitor.27s_attributes_data">Save current monitor's attributes data</span></span></span></span></span></span> ====
+
The data can also be '''Enabled, Disabled, '''and&nbsp;'''Edited.'''
  
On the&nbsp;'''Collect New Data''' page, if a user has finished inputting data to the current monitor, and selects Save, all the current monitor fields turn grey except the Monitor drop-down list and the user cannot edit any data. The current monitor name in the Monitor drop-down box changes to 'monitor_name (Saved)' where monitor_name is the name of the current monitor. Now the user can switch to another monitor to input attributes data to that monitor.
+
'''Enabling Data''' restores a data record from disabled status. To do this:
  
&nbsp;
+
#Select the data record from the disabled data list, then click the [[File:Enable-monitor-icon.png|enable data icon]] &nbsp;in the toolbar.&nbsp;  
  
'''Figure 87: Save Monitor Attributes'''
+
A data record in the data list stands for a single point in a control chart.&nbsp;'''Disabling '''a data record will remove the associated point from the control chart. To disable a data item:
  
[[File:Save Monitor Attributes.png|700px|Save Monitor Attributes]]
+
#Check the box of a data record, then click the&nbsp;[[File:Disable-monitor-icon.png|disable data icon]] in the toolbar.&nbsp;
  
&nbsp;
+
<br/> Users can search disabled data records by setting the time frame for the data record by selecting the beginning date and ending date, and selecting Disabled from the data status drop-down box. Then click the '''Search icon''' to execute the search action.&nbsp;
  
&nbsp;
+
'''Edit Data '''function is limited to the monitor whose data is manually collected by SPC UI. To edit data record:
  
==== <span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor"><span class="mw-headline" id="Switch_to_Another_Monitor">Switch to Another Monitor</span></span></span></span></span></span> ====
+
#From the Monitor List page, select a monitor whose Collection Type value is Manual,&nbsp;and click the [[File:Data-icon.png|data icon]] icon.
 
+
#In the Data List page which lists the enabled data, go to the last page of the list, select the last line and click [[File:Edit-icon.png|edit icon]]&nbsp;in the toolbar (only the last data record is allowed to be modified). The user will be&nbsp;redirected to the Edit Data page where any data fields may be edited.
To switch to another monitor to input attributes, click the Monitor drop-down box and select another monitor from the list
+
#Select '''Save '''to complete the changes.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 88: Selecting Another Monitor'''
+
'''Figure 70: Data List - Edit'''
  
[[File:Selecting Another Monitor.png|700px|Selecting Another Monitor]]
+
[[File:Edit Data Page.png|border|900px|Edit Data Page]]
  
 
&nbsp;
 
&nbsp;
Line 1,409: Line 1,380:
 
&nbsp;
 
&nbsp;
  
==== <span class="mw-headline" id="Back_to_the_.27Monitor_List.27_page"><span class="mw-headline" id="Back_to_the_.27Monitor_List.27_page"><span class="mw-headline" id="Back_to_the_.27Monitor_List.27_page"><span class="mw-headline" id="Back_to_the_.27Monitor_List.27_page"><span class="mw-headline" id="Back_to_.27Monitor_List.27_page">Back to the 'Monitor List' page</span></span></span></span></span> ====
+
&nbsp;
  
To go back to the Monitor List page, select the [[File:New record button.png|new record button]] button.
 
  
&nbsp;
+
== <span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock">Maintain Lock</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
'''Figure 89: Monitor List - New Record'''
+
SPC offers&nbsp;a full set of functions to manage MFG hold. When creating a new monitor, users can [[#Actions|define the minutes of delay before MFG hold was sent]]. Users may view lock records and unlock existing locks as well.
 
 
[[File:Monitor List - New Record.png|700px|Monitor List - New Record]]
 
  
 
&nbsp;
 
&nbsp;
Line 1,423: Line 1,391:
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="Start.2C_Stop.2C_Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Start.2C_Stop.2C_Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Start.2C_Stop.2C_Disable.2C_Enable.2C_Delete_Monitor"><span class="mw-headline" id="Start.2C_Stop.2C_Disable.2C_Enable.2C_Delete_Monitor">Start, Stop, Disable, Enable, Delete Monitor</span></span></span></span> ==
+
=== <span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock">View Lock</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
=== <span class="mw-headline" id="Start_monitor"><span class="mw-headline" id="Start_monitor"><span class="mw-headline" id="Start_monitor"><span class="mw-headline" id="Start_monitor"><span class="mw-headline" id="Start_monitor">Start monitor</span></span></span></span></span> ===
+
#To view lock, from the Monitor List, select a monitor and click the [[File:Lock-button.png|lock button]] icon in the toolbar. The Lock List page displays.
  
After a new monitor is created, its status is Enabled by default. If the monitor's data is automatically collected from SFDC, it must be started manually<span style="line-height: 1.5em;">&nbsp;</span><span style="line-height: 1.5em;">to make it collect data from SFDC.</span>
+
&nbsp;
 
 
<span style="line-height: 1.5em;">1. To start a monitor, check the box of a monitor in the Monitor List page and select the </span>[[File:Start-monitor-button.png|start monitor button]]<span style="line-height: 1.5em;">icon in the toolbar.</span>
 
  
&nbsp;
+
'''Figure 71: Monitor List - Lock'''
  
'''Figure 90: Monitor List - Start'''
+
[[File:SPC lock.png|900px|SPC lock.png]]<br/> The Pareto Chart, C chart, U chart, NP chart, P chart, FPY chart, Xbar-R chart, and I-MR chart&nbsp;can send an MFG hold request&nbsp;to MDS. Users can view locks in different statuses as long as different values are selected in the lock status drop-down list. For example, if a user wants to find locked locks, select LOCKED from the lock status drop-down list, and click the [[File:Search-icon.png|search icon]] icon in the toolbar.
  
[[File:Monitor List - Start1.png|700px|Monitor List - Start1]]
+
'''Figure 72: Lock Search Drop-down'''
  
<br/> '''Note''': Users search started monitors in the monitor list, by selecting Started from the monitor status drop-down list and clicking the [[File:Search-button.png|search button]] icon.
+
[[File:SPC LockSearch.png|900px|SPC LockSearch.png]]
  
 
&nbsp;
 
&nbsp;
 
'''Figure 91: Monitor Name with Started Status Selected'''
 
 
[[File:Search-started-monitor.jpg|300px|Search-started-monitor.jpg]]
 
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
Users can search lock data by control chart type and lock status.<br/> There are four statuses for locks: '''WAITING, LOCKED, UNLOCKED, '''and'''CANCELED. The CANCELED'''
  
=== <span class="mw-headline" id="Stop_monitor"><span class="mw-headline" id="Stop_monitor"><span class="mw-headline" id="Stop_monitor"><span class="mw-headline" id="Stop_monitor">Stop monitor</span></span></span></span> ===
+
*'''WAITING''': the lock that is waiting to be sent to MDS. When an out-of-control case is detected, SPC will wait some minutes before sending the MFG hold to MDS&nbsp;until it reaches the number of minutes defined by '''Send MFG hold request after * minutes''' field in the&nbsp;[[#Actions|Actions]] section. During this period, the lock is in WAITING status.
 +
*'''LOCKED''': MFG hold has been sent, associated location or process has been locked and OCAP has not been processed.
 +
*'''UNLOCKED''': User input OCAPs to unhold the associated location or process, then the locked lock becomes UNLOCKED.
 +
*'''CANCELED''': This lock status is a new status as of SPC 3.2. For a better understanding of this status, consider the following scenario: A SPC monitor was created for Pareto Chart that 3 defect codes of the same type within 10 minutes will trigger the exception, and MFG hold will be sent to MDS 5 minutes later. A few minutes later, a first MFG hold will be&nbsp;triggered, if a second MFG hold is&nbsp;triggered during the first hold’s delayed sending time in the new lock mechanism, the second hold will not be sent to MDS, and the status of the second MFG hold is CANCELED.
  
If a user does not want a monitor to collect data from SFDC, the monitor can be stopped. To stop a monitor,
+
To unlock a lock:
  
#Check the box of a monitor and click the [[File:Stop-monitor-button.png|stop monitor button]] icon in the toolbar.  
+
#Select the lock and click the [[File:Unlock-icon.png|unlock icon]] icon in the toolbar.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 92: Monitor List - Stop'''
+
'''Figure 73: Unlock Icon'''
  
[[File:Monitor List - Stop1.png|700px|Monitor List - Stop1]]
+
[[File:OCAP - Unlock.png|700px|OCAP - Unlock]]
 
 
<br/> NOTE: Users can search stopped monitors in the monitor list, by selecting Stopped from the monitor status drop-down box &nbsp;and clicking the [[File:Search-button.png|search button]] icon.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 93: Monitor Name with Stopped Status Selected'''
+
Users can export the lock list to an CSV&nbsp;file:
  
[[File:Search-stopped-monitor.jpg|300px|Search-stopped-monitor.jpg]]
+
#On the Lock List page, click the [[File:Export-sn-icon.png|export icon]] icon at the bottom of the list.
 +
#Select '''Yes '''in the pop-up window to confirm the action.  
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
<br/> &nbsp;
  
=== <span class="mw-headline" id="Disable_monitor"><span class="mw-headline" id="Disable_monitor"><span class="mw-headline" id="Disable_monitor"><span class="mw-headline" id="Disable_monitor"><span class="mw-headline" id="Disable_monitor">Disable monitor</span></span></span></span></span> ===
 
  
If a user does not need a monitor to operate, the user can disable the monitor.
+
== <span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details">View Monitor Details</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
#To disable a monitor, check the box of the monitor.
+
To learn detailed information about a monitor:
#Select Stop.
+
 
#Select the [[File:Disable-monitor-button.png|disable monitor button]] icon to disable the monitor.  
+
#Go to the Monitor List page, select a monitor, and click the [[File:More.png|more icon]] text link at the right side of the line.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 94: Function List - Disable'''
+
'''Figure 74: Function List - More'''
  
[[File:Function List - Disable1.png|700px|Function List - Disable1]]
+
[[File:SPC More.png|900px|SPC More.png]]
  
<br/> Users can search disabled monitors using the search function by selecting Disabled from the monitor status drop-down box and clicking the [[File:Search-button.png|search button]] icon.
+
&nbsp;
 +
<ol start="2">
 +
<li>In the pop-up Monitor, the details window provides multiple items of information including monitor name, data collection strategy, interval, rules, selected charts, and actions.</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
 
'''Figure 95: Monitor Name with Disabled Status Selected'''
 
 
[[File:Search-disabled-monitor.jpg|300px|Search-disabled-monitor.jpg]]
 
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor"><span class="mw-headline" id="Enable_disabled_monitor">Enable disabled monitor</span></span></span></span> ===
 
  
To enable a disabled monitor
+
= <span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance">Email Maintenance&nbsp;[[File:SPC EmailMaintenanceIcon.png]]</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
  
#Find the disabled monitor in the list and check the box for that monitor.
+
Email notification is an important way for SPC to monitor the manufacturing line in real-time. When exceptions are found, SPC will send an email alert to the associated employee or supervisor so that they can analyze the exception according to the alert email and other SPC tools, and take appropriate measures, such as checking the production line, writing OCAPs, and stopping the line.
#Click the [[File:Enable-monitor-button.png|enable monitor button]] icon in the toolbar.  
 
  
&nbsp;
+
To access the Email Maintenance Page:
  
'''Figure 96: Function List - Enable'''
+
#Go to the Function List page and click the [[File:Email-maintenance-icon.png|email maintenance icon]] icon to enter the email maintenance module.
  
[[File:Function List - Enable1.png|700px|Function List - Enable1]]
+
From the&nbsp;'''Email Maintenance''' page, the users are able to access the following functionalities:
  
<br/> Users can search enabled monitors using the search function by selecting Enabled from the monitor status drop-down list and clicking the [[File:Search-button.png|search button]] icon.
+
*'''Email Group'''
  
&nbsp;
+
*'''Add Monitor Receive Email Rules'''
  
'''Figure 97: Monitor Name with Enabled Status Selected'''
+
*'''Edit Monitor Receive Email Rules'''  
  
[[File:Search-enabled-monitor.jpg|300px|Search-enabled-monitor.jpg]]
+
*'''Enable'''
  
&nbsp;
+
*'''Disable'''
  
=== <span class="mw-headline" id="Delete_Monitor.2FDelete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor.2FDelete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor.2FDelete_Monitor_in_Batch"><span class="mw-headline" id="Delete_Monitor.2FDelete_Monitor_in_Batch">Delete Monitor/Delete Monitor in Batch</span></span></span></span> ===
+
*'''Search'''  
 
 
If a user no longer needs a monitor or monitor in batch and wants to remove it, the monitor can be deleted. Note that once a monitor is deleted from SPC, it cannot be restored, and this is permanent.&nbsp;
 
 
 
To delete a monitor&nbsp;
 
 
 
#Check the box of the monitor to be deleted, and select&nbsp;'''Disable''' to disable the monitor first.
 
#Once the monitor is disabled, locate the monitor in the disabled monitor list, and check the box of the monitor to select it
 
#Click the [[File:Delete-monitor-button.png|delete monitor button]] icon in the toolbar.
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 98: Function List - Delete'''
+
'''Figure 75: Email Maintenance'''
  
[[File:Function List - Delete1.png|700px|Function List - Delete1]]
+
'''[[File:SPC EmailMaintenanceMain.png|900px|SPC EmailMaintenanceMain.png]]'''
  
 
&nbsp;
 
&nbsp;
<ol start="4">
 
<li>Then choose Yes in the pop-up window</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 99: Delete Pop-up'''
+
== <span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance">Email Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
[[File:Delete Pop-up.png|Delete Pop-up.png]]
+
The&nbsp;'''Email Group Maintenance '''submodule allows users to add, edit, delete, and search email groups and also,&nbsp; associate emails to groups.
  
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP"><span class="mw-headline" id="View_Control_Chart.2C_Data_.26_Write_OCAP">View Control Chart, Data & Write OCAP</span></span></span></span> ==
+
'''Figure 76: Email Group Maintenance'''
  
Control Chart is a very important tool for SPC to monitor the manufacturing line. Through the analysis of control charts, users can learn whether a manufacturing line or process is under control and determine the reasons for an out-of-control exception, so that they can take appropriate measures. To date, our SPC system supports 11 control charts: C chart, U chart, P chart, NP chart, DPMO chart, FPY chart, Yield chart, Pareto chart, X Bar-R chart, I-MR chart, and Cpk / Ppk chart.
+
[[File:SPC EmailGroupMaintenance.png|900px|SPC EmailGroupMaintenance.png]]<br/> &nbsp;
  
Beginning with SPC 3.2, the SPC development team applies Ext JS technology other than the old Jfreechart technology to all of the 11 control charts. The Ext JS technology enables SPC to represent more interactions with the user from the UI perspective. For instance, a user can view more information about a chart point by hovering their cursor over the point. Also, users can view both SPC charts and data on the same page without having to open them on different pages.
+
&nbsp;
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
=== <span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group">Add Email Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
 +
 
 +
The first thing that the user needs to do is create a User Group with a name and description to create the Receive Emails Rules.
  
=== <span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart"><span class="mw-headline" id="View_Control_Chart">View Control Chart</span></span></span></span></span> ===
+
#Select&nbsp;on the New button to create an email group.
  
Here take the C chart as an example to demonstrate how to view the control chart with the Ext JS technology enhancement. The operation of other control charts is similar to the C chart below.
+
'''Figure 77: Email Group Maintenance - New'''
  
#To SPC view the control chart, from the Monitor List page, select a monitor, and click the [[File:Chart-button.png|chart button]] icon in the toolbar. This displays the chart page.
+
[[File:SPC emailgroupmaintenance .png|900px|SPC emailgroupmaintenance .png]]
  
 
&nbsp;
 
&nbsp;
 +
<ol start="2">
 +
<li>Enter the '''Name''' and '''Description''' (mandatory fields) for the new email group; Select the [[File:Save button.png|save button.png]] to keep the configuration to SPC.&nbsp;</li>
 +
</ol>
  
'''Figure 100: Function List - Chart'''
+
=== <span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group">Edit Email Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:Function List - Chart.png|700px|Function List - Chart]]
+
To update the email group information:
 
 
<br/> '''Note''':&nbsp;On the top of the page you will see a few brief information on the control chart, such as to monitor name, part number, location. The family ID can also be displayed here if the Display Family ID is checked in the SPC Portal System Parameter&nbsp;module.
 
  
To view the C chart, you need to choose ''''C'''' chart from the chart drop-down list, select a revision from the revisions drop-down list, and click '''Retrieve''', then SPC generates a C Chart according to the parameters you submitted and displays the C Chart and its data in the current page.
+
#Select the Edit button to update the email group information.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 101: C-Chart Retrieve'''
+
'''Figure 78: Email Group Maintenance - Edit'''
  
[[File:C-chart-extjs.png|700px|C-chart-extjs.png]]
+
[[File:SPC EmailGroupMaintenanceEdit.png|900px|SPC EmailGroupMaintenanceEdit.png]]&nbsp;&nbsp;
  
<br/> '''Tips''':
+
Update Name or Description fields as needed.&nbsp;&nbsp;Select the [[File:Save button.png|save button.png]] to keep the updates.
 
 
#On the Chart, blue points are normal points, red points are exception points, green points are exception points that have been written OCAP
 
#If you move the cursor over a point in the chart, a pop-up window will be prompted showing more information on the selected point, including '''SPC Collection Time''', '''Inspected''', '''Defects''' and '''Cause'''. Note that control charts vary in more information on a selected point.
 
#If you click a point on the chart, the corresponding data line in the data list will be highlighted; if you select a data line from a data list, the corresponding point on the chart will be highlighted as well
 
#The red background of a data line means that this data item has violated the rules you defined in the [[#Rules|Rules]] section, and the OCAP of this data record has not been processed yet; the green background of a data line indicates that OCAP of this data record has been processed.
 
#This data list table structure consists of 9 columns: SPC Collection Time, Inspected, Defects, UCL, LCL, OCAP, OCAP History, Cause and Affected S/Ns.  
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 102: C-Chart Information Points'''
+
=== <span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email">Associate Email</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:Over point.png|700px|Over point.png]]
+
After creating an email group, the user is able to associate as many as emails is needed.
 +
 
 +
#To associate emails to the group, select a group in the list and click on Associate Email.  
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
'''Figure 79: Email Group Maintenance - Associate Email'''
  
=== <span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP"><span class="mw-headline" id="Write_OCAP">Write OCAP</span></span></span></span></span> ===
+
[[File:SPC AssociateEmail.png|900px|SPC AssociateEmail.png]]
  
To write OCAP means to write something about the fix to the exception. To do this
+
&nbsp;
  
#Click the [[File:Ocap-button.png|ocap button]] icon, then input the description of this OCAP in the pop-up OCAP windows.
+
The email list page will&nbsp;display,&nbsp;and the user can add, edit, or delete emails.
#Click [[File:Save-button.png|save button]]&nbsp;to save the change to SPC.  
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 103: OCAP&nbsp;Window'''
+
==== <span class="mw-headline" id="Add.2C_Edit.2C_and_Delete_Emails_to_Group"><span class="mw-headline" id="Add.2C_Edit.2C_and_Delete_Emails_to_Group"><span class="mw-headline" id="Add.2C_Edit.2C_and_Delete_Emails_to_Group"><span class="mw-headline" id="Add.2C_Edit.2C_and_Delete_Emails_to_Group"><span class="mw-headline" id="Add.2C_Edit.2C_and_Delete_Emails_to_Group"><span class="mw-headline" id="Add.2C_Edit.2C_and_Delete_Emails_to_Group">Add, Edit, and Delete Emails to Group</span></span></span></span></span></span> ====
  
[[File:OCAP window.png|700px|OCAP window.png]]
+
To add an email to the group:
  
<br/> If there are more than one unprocessed OCAPs after entering a description of the current OCAP, enable the '''Apply to previous OCAPs''' checkbox to apply the change to all the unprocessed OCAPs.
+
#From the Email List page, click on the '''New '''button''':'''  
  
After the OCAP is processed, the background of the associated data record will turn green.
+
&nbsp;
  
&nbsp;
+
'''Figure 80: Add New Email to Group'''
  
=== <span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History"><span class="mw-headline" id="View_OCAP_History">View OCAP History</span></span></span></span> ===
+
[[File:SPC AddNewEmailtoGroup.png|900px|SPC AddNewEmailtoGroup.png]]
  
Select [[File:Ocap-history.png|OCAP history button]]&nbsp;to view the OCAP history of a data record in the pop-up OCAP history window.
+
&nbsp;
 +
<ol start="2">
 +
<li>Insert the email in the Email field (mandatory) and select '''Save'''&nbsp;to keep the email in the group.&nbsp;In the same way, users can '''Edit''' and '''Delete''' by clicking the icons in the toolbar.&nbsp;</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
  
'''Figure 104: OCAP&nbsp;History'''
+
=== <span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group">Search Email Group</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:Ocap history.png|700px|Ocap history.png]]
+
Users can search existing email groups by keyword:&nbsp;
 +
 
 +
#Select the kind of keyword in the keyword category drop-down list (Name or Description).&nbsp;
 +
#Enter the keyword in the keyword textbox, and click the&nbsp;'''Search'''&nbsp;icon to search.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause"><span class="mw-headline" id="View_Cause">View Cause</span></span></span></span> ===
+
'''Figure 81: Email Group Maintenance - Search Email'''
  
Select&nbsp;[[File:Cause-button.png|cause button]]&nbsp;to view the rules that the current point has violated.
+
[[File:SPC SearchEmail.png|900px|SPC SearchEmail.png]]
  
 
&nbsp;
 
&nbsp;
  
'''Figure 105: Cause'''
+
Users can also Edit and delete email groups. The&nbsp;'''Reference by Email Rule''' will show a '''Tip'''.
 
 
[[File:Cause.png|700px|Cause.png]]
 
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs"><span class="mw-headline" id="View_Affected_S.2FNs">View Affected S/Ns</span></span></span></span> ===
+
'''Figure 82: Email Group Maintenance - Tip'''
  
Users can view the affected serial numbers and export them to an Excel file.
+
'''[[File:SPC Tip.png|900px|SPC Tip.png]]'''
  
#Select&nbsp;[[File:Affected-sn-button.png|affected S/Ns button]] to activate a pop-up window that displays the affected S/Ns list.
+
<br/> &nbsp;
 +
 
 +
== <span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule">New Email Rule</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
 
&nbsp;
 
&nbsp;
  
'''Figure 106: Affected Serial Numbers'''
+
This functionality allows users to create email rules as needed.
  
[[File:Affected serial numbers.png|700px|Affected serial numbers.png]]
+
To create a new email Rule, in the Email Maintenance Page, select the '''New''' button.
  
 
&nbsp;
 
&nbsp;
<ol start="2">
 
<li>To export the affected S/Ns to an Excel file, click the [[File:Export-sn-icon.png|export affected S/Ns icon]] icon at the bottom of the Affected S/Ns window.</li>
 
<li>Select '''Yes '''to confirm the action.</li>
 
</ol>
 
  
&nbsp;
+
'''Figure 83: Email Maintenance - New Email Rule'''
 +
 
 +
[[File:SPC NewEmailRule.png|700px|SPC NewEmailRule.png]]
  
'''Figure 107: Confirm Export Alert'''
+
From this page, the user needs to enter the '''Name''', '''Description''', and associate an '''Email Group''' (mandatory fields), created in the Email Group functionality.
  
[[File:Confirm export alert.png|700px|Confirm export alert.png]]&nbsp;
+
After this, the rules can be created as needed by: '''Shop Floor ID''', '''Part Number''', '''Family ID''', '''Process''', '''Location''', '''Family ID,''' and '''Monitor Group'''.&nbsp;
  
&nbsp;
+
To '''Edit''' and or '''Delete''' the Email Rule, the user must use the corresponding icons on the toolbar.
<ol start="4">
+
 
<li>Choose whether to open the XLS file or save it to the hard drive.</li>
+
This functionality allows users to edit the email rules as needed, when '''Delete''' is selected Select '''Yes''' in the pop-up window to confirm the action.
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 108: Open or Save XLS'''
+
&nbsp;
 
 
[[File:Open-save-sn.jpg|400px|Open-save-sn.jpg]]
 
  
 
&nbsp;
 
&nbsp;
  
For P Chart, some enhancements were implemented as displayed below:&nbsp;
+
== <span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Enable_.2F_Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule">Enable / Delete Email Rule</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
Label 1 shows the number of Defective / Inspected. It means the number of defective units / total number of samples, this value should be between 0 and 1.
+
To '''Enable or&nbsp;Disable'''&nbsp;an '''Email Rule'''&nbsp;record from their status:
  
This value should also be displayed in label 2 and label 3. but the current system uses defects / inspected. The number of defects / inspected may be greater than 0, this will make users confused.
+
#'''Select the email rule record from the enabled/disabled data list, '''then click the enable icon in the toolbar.  
  
 
&nbsp;
 
&nbsp;
  
'''Figure 109: SPC_P Chart Sample'''
+
'''Figure 84: Enable / Disable Email Rule'''
 +
 
 +
[[File:SPC enableanddiableemailrule.png|900px|SPC enableanddiableemailrule.png]]
  
[[File:SPC P Chart Sample.png|700px|SPC_P Chart Sample]]
+
When '''Delete''' is selected, click&nbsp;'''Yes''' in the pop-up confirms window.&nbsp;
  
&nbsp;
+
== <span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email">Alert Email</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
== <span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data"><span class="mw-headline" id="View_and_Edit_Data">View and Edit Data</span></span></span></span> ==
+
Alert emails from SPC will contain titles like '''Alert message from SPC application''' that will contain seven information fields: '''Line, Monitor, Part Number, Location, Chart, Date, and Description'''.&nbsp;<br/> When the users click the link in the mail, the system will access the charts which were generated by the alert email.
  
=== <span class="mw-headline" id="View_Data_List"><span class="mw-headline" id="View_Data_List"><span class="mw-headline" id="View_Data_List"><span class="mw-headline" id="View_Data_List">View Data List</span></span></span></span> ===
+
&nbsp;
  
Users can view detailed data of a monitor. To do this,
+
'''Figure 85: View the Chart from the Email Link'''
  
#Select a monitor and click the [[File:Data-icon.png|data icon]] icon in the toolbar in the Monitor List page.&nbsp;
+
[[File:Figure- Go to Chart from the email.png|900px|Alert email example]]
  
 
&nbsp;
 
&nbsp;
  
'''Figure 110: Data List'''
 
  
[[File:Data List.png|700px|Data List]]
+
= <span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance">Lock Maintenance&nbsp;[[File:SPC LockMaintensanceIcon.png]]</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
 +
 
 +
This functionality allows the user to unlock hold, search lock records by time range, and export hold records on one page.
  
 
&nbsp;
 
&nbsp;
  
In the ‘Data List’ page, set the time frame for the search by selecting the beginning date and ending date in the toolbar (the green frame area in Figure 5.65).
+
== <br/> <span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance">Maintain SPC Lock Maintenance&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
Select a status from the data status drop-down list (the red frame area in Figure 5.65) and click the [[File:Search-icon.png|search icon]] icon to view the matching data.
+
Users may access SPC Lock Maintenance by selecting the&nbsp;[[File:Lock button.png|lock button]] icon on the Function List page.&nbsp;Users may view lock records and unlock existing locks as well.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 111: Data List Page - Search Fields'''
+
=== <span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2">View Lock&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
[[File:Data List Page-Search Fields.png|700px|Search-data-list]]
+
1. To view the lock, from the Monitor List, select a monitor and click the [[File:Lock icon.png|lock icon]] in the toolbar.
  
.
+
Users will be able to perform searches by&nbsp;'''Monitor, Chart, Status, '''and also&nbsp;'''Export.'''
  
Figure 85 shows data records of a monitor whose data is automatically collected by SFDC.&nbsp;
+
'''Figure 86: Lock Maintenance - Lock List'''
  
&nbsp;
+
[[File:SPC locklist.png|900px|SPC locklist.png]]
  
'''Figure 112: Data List - Automatically Collected Records'''
+
The lock mechanism has been modified so only the Pareto chart can send an MFG hold request&nbsp;to&nbsp;MDS. Users can view locks in different statuses if different values are selected in the lock status drop-down list. For example, if a user wants to find locked locks, select '''LOCKED''' from the lock status drop-down list, and click the '''Search''' '''icon''' in the toolbar.&nbsp;
  
[[File:Data List - Automatically Collected Records.png|700px|Data List - Automatically Collected Records]]
+
&nbsp;
  
<br/> Figure 86 shows data records of a monitor whose data is manually collected via SPC U.
+
*'''WAITING''': the lock waiting to be sent to MDS / SFDC. When the out-of-control case is detected, SPC will wait some minutes before sending the MFG hold to MDS until it reaches the number of minutes defined by '''Send MFG to hold requests after * minutes''' field in the&nbsp;'''Actions''' section. During this period, the lock is in WAITING status.&nbsp;
 +
*'''LOCKED''': MFG hold has been sent, the associated location or process has been locked and OCAP has not been processed.&nbsp;
 +
*'''WAITING UNLOCKED: '''When users operate unlock in the lock page, first the "waiting for unlock" status, is followed by the "unlocked" status.
 +
*'''UNLOCKED''': The user input OCAPs to the on-hold&nbsp;associated location or process, then the locked lock becomes UNLOCKED.&nbsp;
 +
*'''CANCELED''': This lock status is a new status as of SPC 3.2. For a better understanding of this status, consider the following scenario: A SPC monitor was created for the Pareto Chart that 3 defect codes of the same type within 10 minutes will trigger the exception, and an MFG hold will be sent to&nbsp;MDS 5 minutes later. A few minutes later, a first MFG hold will be&nbsp;triggered, if a second MFG hold is&nbsp;triggered during the first hold’s delayed sending time in the new lock mechanism, the second hold will not be sent to MDS, and the status of the second MFG hold is CANCELED.
  
&nbsp;
 
  
'''Figure 113: Data List - Manually Collected Records'''
+
= <span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance">Location Family Maintenance&nbsp;[[File:SPC LocationFamilyMaintenanceIcon.png]]</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
  
[[File:Data List - Manually Collected Records.png|700px|Data List - Manually Collected Records]]
+
The location family is a collection of locations. One location family consists of one or more locations, which can be derived from different processes and departments. The authorized user can create, search, edit, disable, delete, and enable location family.
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Disable_Data"><span class="mw-headline" id="Disable_Data"><span class="mw-headline" id="Disable_Data"><span class="mw-headline" id="Disable_Data">Disable Data</span></span></span></span> ===
+
== <span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family">Create Location Family</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
A data record in the data list stands for a single point in a control chart. Disabling a data record will remove the associated point from the control chart. To disable a data item,
+
To create a new location family:
  
Check the box of a data record, then click the [[File:Disable-monitor-icon.png|disable data icon]] icon in the toolbar.
+
#Select the [[File:Function List - Location Family Maintenance.png|location family icon]] icon on the Function List page.
 +
#&nbsp;On-Location Family List page, click [[File:New-server.png|new server icon]] button in the toolbar.  
 +
#Select '''Process,&nbsp;'''or '''Department.'''
  
 
&nbsp;
 
&nbsp;
  
'''Figure 114:&nbsp;Data List - Disable'''
+
'''Figure 88: Location Family List Page - New Icon'''
  
[[File:Data List Disable.png|700px|Data List Disable]]
+
[[File:SPC Locationfamilylistpage.png|900px|SPC Locationfamilylistpage.png]]
  
<br/> Users can search disabled data records by setting the time frame for the data record by selecting the beginning date and ending date and selecting Disabled from the data status drop-down box (the red frame area in Figure 5.69). Then click the [[File:Search-icon.png|search icon]] icon to execute the search action.
+
&nbsp;
  
 
&nbsp;
 
&nbsp;
 
+
<ol start="4">
'''Figure 115: Data List - Search Fields'''
+
<li>Enter values in the '''Location''' textbox to filter locations. If a user changes the values of the Location textbox, its instant search function activates, and the SPC system automatically searches matching locations from the locations that belong to the selected department, displaying matching locations in the Location selection box.</li>
 
+
<li>Select a location and click the [[File:Right-arrow.png|right arrow icon]] button to add locations from the left panel to the right panel. More than one location can be selected at a time.</li>
[[File:Data List Page-Search Fields.png|700px|Search-data-list]]
+
</ol>
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Enable_Data"><span class="mw-headline" id="Enable_Data"><span class="mw-headline" id="Enable_Data"><span class="mw-headline" id="Enable_Data">Enable Data</span></span></span></span> ===
+
'''Figure 89: Add Location'''
  
Enabling data restores a data record from disabled status. To do this,
+
'''[[File:SPC AddLocation.png|900px|SPC AddLocation.png]]'''
  
1. Select the data record from the disabled data list, then click the [[File:Enable-monitor-icon.png|enable data icon]] icon in the toolbar.
+
&nbsp;
 +
<ol start="6">
 +
<li>Lastly, click the Save button to '''Save''' your data to SPC.&nbsp;</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
  
'''Figure 116: Data List - Enable'''
+
&nbsp;
 
 
[[File:Data List - Enable.png|700px|Data List - Enable]]
 
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Edit_Data"><span class="mw-headline" id="Edit_Data"><span class="mw-headline" id="Edit_Data"><span class="mw-headline" id="Edit_Data">Edit Data</span></span></span></span> ===
+
=== <span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family"><span class="mw-headline" id="Edit_and_Delete_Location_Family">Edit and Delete Location Family&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
This function is limited to the monitor whose data is manually collected by SPC UI. To edit data record
+
&nbsp; To edit a location family:
  
#From the Monitor List page, select a monitor whose Collection Type value is Manual. and click the [[File:Data-icon.png|data icon]] icon.
+
#Select a location family from the list, then click the '''Edit''' '''icon''' in the toolbar. The Edit Location Family page will display.&nbsp;
#In the Data List page which lists the enabled data, go to the last page of the list, select the last line and click [[File:Edit-icon.png|edit icon]]&nbsp;in the toolbar (Only the last data record is allowed to be modified). The user is redirected to the Edit Data page where any data fields may be edited.
 
#Select '''Save '''to complete the changes.  
 
  
&nbsp;
+
'''&nbsp;&nbsp;'''
  
'''Figure 117: Data List - Edit'''
+
'''Figure 90: Location Family Edit&nbsp;'''
  
[[File:Data List - Edit.png|700px|Data List - Edit]]
+
[[File:SPC Locationfamilyedit.png|900px|SPC Locationfamilyedit.png]]
 +
<ol start="2">
 +
<li>In the Edit Location Family page, edit any field you want, and save the changes.&nbsp;</li>
 +
</ol>
 +
 
 +
&nbsp; To delete a location family, '''the user has to Disable the location first'''. &nbsp;
 +
 
 +
&nbsp;
 +
 
 +
#Select the location family and click '''Disable'''.
 +
#Search the disabled location family list for the disabled location family, select the location family, and click '''Delete'''.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 118: Edit Data Page'''
+
'''Figure 91: Location Family List - Delete'''
  
[[File:Edit Data Page.png|700px|Edit Data Page]]
+
[[File:SPC Locationfamilydelete.png|900px|SPC Locationfamilydelete.png]]
 +
<ol start="3">
 +
<li>Select&nbsp;'''Yes''' to confirm the action.&nbsp;</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock"><span class="mw-headline" id="Maintain_Lock">Maintain Lock</span></span></span></span> ==
+
=== <span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family"><span class="mw-headline" id="Enable_.2F_Disable_Location_family">Enable / Disable Location family&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
 +
 
 +
&nbsp; To enable a location family:
  
SPC offers you a full set of functions to manage MFG hold. When [[#Create_SPC_Server|creating a new SPC server]], users can decide whether to send MFG hold requests to MDS / SFDC. When creating a new monitor, users can [[#Actions|define the minutes of delay before MFG hold was sent]]. Users may view lock records and unlock existing locks as well.
+
#Select a location family and click the&nbsp;'''Enable icon''' in the toolbar.&nbsp;
  
&nbsp;
+
&nbsp; &nbsp;
  
=== <span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock"><span class="mw-headline" id="View_Lock">View Lock</span></span></span></span> ===
+
'''Figure 92: Location Family List - Enable'''
  
#To view lock, from the Monitor List, select a monitor and click the [[File:Lock-button.png|lock button]] icon in the toolbar. The Lock List page displays.  
+
[[File:SPC Locationfamilylistenable.png|900px|SPC Locationfamilylistenable.png]]
 +
<ol start="2">
 +
<li>Choose&nbsp;'''Yes '''in the pop-up window.&nbsp;</li>
 +
</ol>
  
 
&nbsp;
 
&nbsp;
  
'''Figure 119: Monitor List - Lock'''
+
DeleteTo disable a location family:
  
[[File:Monitor List Lock.png|700px|Monitor List Lock]]
+
Select a location family and click the '''Disable icon''' in the toolbar.&nbsp;
  
 
&nbsp;
 
&nbsp;
  
'''Figure 120: Lock List Page'''
+
'''Figure 93: Location Family List - Disable'''
  
[[File:SOP-5-I-MES0069-C Lock List Page.jpg|RTENOTITLE]]
+
[[File:SPC Locationfamilylistendisable.png|900px|SPC Locationfamilylistendisable.png]]
  
<br/> Beginning with SPC 3.2, the lock mechanism has been modified so that only the Pareto chart can send MFG hold requests to SFDC / MDS. Users can view locks in different status as long as different values are selected in the lock status drop-down list. For example, if a user wants to find locked locks, select LOCKED from the lock status drop-down list, and click the [[File:Search-icon.png|search icon]] icon in the toolbar.
+
Choose '''Yes''' in the pop-up confirms window.&nbsp; &nbsp;<br/> &nbsp;
  
&nbsp;
+
=== <span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family">Search Location Family&nbsp;</span></span></span></span></span></span></span></span></span></span></span></span></span></span> ===
  
'''Figure 121: Lock Search Drop-down'''
+
&nbsp; SPC enables users to search for location families by keyword and status. To search for a location family:
  
[[File:Lock Search Dropdown.png|300px|Lock Search Dropdown]]
+
#Go to the '''Location Family '''List page
 +
#Select a '''keyword category,''' and input a keyword in the text input box
 +
#'''Select a status'''
 +
#Select the '''Search icon'''
  
User can search lock data by control chart type and lock status.<br/> There are four statuses for locks: WAITING, LOCKED, UNLOCKED, and CANCELED. The CANCELED status was added in SPC 3.2.
+
&nbsp;
  
*'''WAITING''': the lock that is waiting to be sent to MDS / SFDC. When an out-of-control case is detected, SPC will wait some minutes before sending the MFG hold to MDS / SFDC until it reaches the number of minutes that defined by '''Send MFG hold request after * minutes''' field in the&nbsp;[[#Actions|Actions]] section. During this period, the lock is in WAITING status.
+
'''Figure 94: Search Location Family'''
*'''LOCKED''': MFG hold has been sent, associated location or process has been locked and OCAP has not been processed.
 
*'''UNLOCKED''': User input OCAPs to unhold associated location or process, then the locked lock becomes UNLOCKED.
 
*'''CANCELED''': This lock status is a new status as of SPC 3.2. For a better understanding of this status, consider the following scenario: A SPC monitor was created for Pareto Chart that 3 defect codes of the same type within 10 minutes will trigger the exception, and MFG hold will be sent to SFDC / MDS 5 minutes later. A few minutes later, a first MFG hold was triggered, if a second MFG hold was triggered during the first hold’s delay sending time in the new lock mechanism, the second hold will not be sent to SFDC / MDS, and the status of the second MFG hold is CANCELED.
 
  
&nbsp;
+
[[File:SPC SearchLocationFamily.png|900px|SPC SearchLocationFamily.png]]
  
=== <span class="mw-headline" id="Unlock_Lock"><span class="mw-headline" id="Unlock_Lock"><span class="mw-headline" id="Unlock_Lock"><span class="mw-headline" id="Unlock_Lock">Unlock Lock</span></span></span></span> ===
 
  
To unlock a lock
+
= <span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance">System Log Maintenance&nbsp;[[File:SPC SystemLogMaintenanceIcon.png]]</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
  
#Select the lock and click the [[File:Unlock-icon.png|unlock icon]] icon in the toolbar.  
+
Some important system events, such as data modification and stopping a monitor, will be automatically added to SPC system log. System log plays an important role in system security. Users can analyze the system log and decide to take appropriate measures, like data recovery and file backup, to defend the system. In the SPC system, authorized users can search, view, and delete system logs.
  
 
&nbsp;
 
&nbsp;
  
'''Figure 122: Unlock Icon'''
+
== <span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log">Search and View System Log</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> ==
  
[[File:Unlock Icon.png|700px|Data List - Unlock Icon]] &nbsp;
+
On the Function List page, users can click the [[File:System-log-icon.png|system log icon]] icon to navigate to the System Log page. On the '''System Log page''', users can search the system log by time frame or by event owner:
<ol start="2">
 
<li>In the pop-up window, input OCAP to unlock the associated location or process.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 123: OCAP - Unlock'''
+
'''Figure 95: System Log Page'''
  
[[File:OCAP - Unlock.png|700px|OCAP - Unlock]]
+
[[File:SPC systemlogpage.png|900px|SPC systemlogpage.png]]
  
 
&nbsp;
 
&nbsp;
  
=== <span class="mw-headline" id="Export_Lock_List_to_Excel"><span class="mw-headline" id="Export_Lock_List_to_Excel"><span class="mw-headline" id="Export_Lock_List_to_Excel"><span class="mw-headline" id="Export_Lock_List_to_Excel">Export Lock List to Excel</span></span></span></span> ===
+
#Input event owner in the '''Performed by''' textbox or choose a time frame and click the [[File:Search-icon.png|search icon]] icon in the toolbar.
 +
#System log list table structure contains three columns - '''Date''', '''Performed By''', and '''Operation'''.
 +
#Delete System Log'''
  
User can export the lock list to Excel file:
+
Every 24 hours, SPC automatically deletes system logs created 3 months before. Authorized users can delete logs manually via SPC UI. Users can delete logs individually or in batches.&nbsp;
  
#On the Lock List page, click the [[File:Export-sn-icon.png|export icon]] icon at the bottom of the list.
 
  
&nbsp;
 
  
'''Figure 124: Lock List -Export Icon'''
+
= <span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance">SPC System Parameter Maintenance[[File:SPC SPCSystemParameterMaintenaceIcon.png|SPC SPCSystemParameterMaintenaceIcon.png]]</span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> =
  
[[File:Lock List - Import Icon.png|700px|Lock List - Import Icon]]
+
Authorized users are allowed to set general system parameters according to their local plants, manufacturing lines, or other special needs. This part of system parameters configuration affects the performance of the current SPC server, caution is necessary when defining the parameter values.
 
 
&nbsp;
 
<ol start="2">
 
<li>Select '''Yes '''in the pop-up window to confirm the action.</li>
 
</ol>
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 125: Export Confirmation Pop-up'''
+
Users may access SPC System Parameters Maintenance by selecting the&nbsp;&nbsp;icon on the Function List page.
 +
 
 +
<br/> On the '''SPC System Parameter page''', eleven fields are displayed and the user can move their mouse over the [[File:Info-icon.png|more info icon]] icon to learn more information about the labels.
  
[[File:Export Confirmation Pop-up.png|700px|Export Confirmation Pop-up]]
+
See below the fields description:
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
'''Figure 96: SPC System Parameter Page'''
  
== <span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details"><span class="mw-headline" id="View_Monitor_Details">View Monitor Details</span></span></span></span> ==
+
[[File:SPC SPCSystemParameterPagew.png|900px]]
  
To learn detailed information about a monitor
+
An explanation of the fields from&nbsp;the above screenshot follows:&nbsp;
 
 
#Go to the Monitor List page, select a monitor, and click the [[File:More.png|more icon]] text link at the right side of the line.
 
  
&nbsp;
+
*'''Interval of collecting data (second)''': During real-time monitoring, each monitor will periodically collect data from SFDC archive database or other data source, the setting determines how often each monitor collects data.
 +
*'''Interval of deleting log (hour)''': There is one background job (thread) responsible to periodically delete the system log, this setting determines how often the background job deletes some system logs.
 +
*'''Time of log saved (month)''': System log will not be saved forever, a too old log will be deleted by background job, this setting determines how long the system log is saved in the database.
 +
*'''Interval between lock reviews (second)''': How often the background job review lock (or called MFG hold request to determine if one waiting lock should be sent to the MES.
 +
*'''Display family ID in chart''': By selecting this checkbox, the Family ID will&nbsp;display&nbsp;on the SPC chart.
 +
*'''Start time of data collection (month)''': After one monitor is created, this monitor related data can be retrieved from a past time, this setting determines how old data can be when retrieved by monitor. The default value is 3 months.&nbsp;
 +
*'''Hide monitors with no data in chart in the past (hours)''': It allows users to filter out those monitors that have no new data coming in during the past settable hours. Users can input a positive number between 1 to 168 in the textbox. The default value for this textbox is 24. To view the effect, you can check the Hide Inactive Monitors feature on the Monitor List page.&nbsp;
 +
*'''Hide on TV and dashboard if monitors with no data in chart in the past (hours)''': The SPC will automatically disable those monitors that have no new data during the past settable hours.&nbsp;The hours quantity textbox next to it has a default value of 8 (hours). This textbox allows positive integers from 1 to 24.&nbsp;  
  
'''Figure 126: Function List - More'''
+
&nbsp;<u>'''Note'''</u>: All the newly created monitors are enabled by default.&nbsp;Users can define this value, then the system will hide the monitors with no data to avoid there being too many monitors in the list.&nbsp;
  
[[File:Function List - More1.png|700px|Function List - More1]]
+
*'''Enable Previous SPC Hold function''': Previous Hold function will be invoked in the following scenario: after a part number was put on SPC Hold by SPC for the settable number of consecutive defect codes within a set time limit, will display&nbsp;‘PREVIOUS SPC HOLD’ in NetDC rather than issuing an immediate SPC holds.&nbsp;
  
&nbsp;
+
<u>'''Note:&nbsp;'''</u>If a monitor is stopped, disabled, or deleted, the Previous Hold function of this monitor will be automatically turned off as well.&nbsp; Users must enable the Send MFG to hold to &nbsp;MDS checkbox in Add Server Information page first, before enabling the Enable Previous SPC Hold function checkbox.
<ol start="2">
 
<li>In the pop-up Monitor, the details window provides multiple items of information including monitor name, data collection strategy, interval, rules, selected charts, and actions.</li>
 
</ol>
 
  
&nbsp;
+
*'''Enable PCB function''':&nbsp; Enable PCB function as global parameters affect one site. Its default value is unselected. PCB plants need to click the checkbox to make PCB function take effect. The PCB checkbox affects monitor creation and data collection.
  
'''Figure 127: Monitor Details Pop-up'''
+
Enabling the PCB function will enable the following requests from PCB plants when creating an SPC monitor: the ability to see the PN without a route assigned, the ability to display attributes with not defined PN as well as count defect code B.
  
[[File:Monitor Details Pop-up.png|700px|Monitor Details Pop-up]]
+
*'''Email Title''': To set the title of the alarm email.
 +
*'''Enable monitor name in email title: '''This checkbox will send an Alert message from SPC application with the monitor name to the user’s email address.
 +
*'''MESR URL Template''': This field is to set a URL link to the MES Web. The URL template is plantcode-mesweb-med.42-q.com or plantcode-mesweb-med-uat.42-q.com. Hence, the original HTTP URL template is not suitable as a fixed URL link.
  
 
&nbsp;
 
&nbsp;
  
== <span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History"><span class="mw-headline" id="View_Monitor_History">View Monitor History</span></span></span></span> ==
+
After all&nbsp;configurations are done, remember to click the &nbsp;[[File:Save button.png|save button]] icon. If the save was&nbsp;successful, the user will&nbsp;see the message 'Configurations are successfully saved and will be immediately effective'. If there is a malfunction, users will see the error message 'Configurations are not saved, please try again or contact administrator.'&nbsp;
 
 
To view the modification history of a monitor,
 
 
 
#Go to the Monitor List page, select a monitor, and click the [[File:Monitor-history-button.png|monitor history button]] icon.  
 
  
 
&nbsp;
 
&nbsp;
  
'''Figure 128: Monitor List - Rev Icon'''
 
 
[[File:Monitor List - Rev Icon.png|700px|Monitor List - Rev Icon]]
 
  
 
&nbsp;
 
&nbsp;
 
= <span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance"><span class="mw-headline" id="Email_Maintenance">Email Maintenance</span></span></span></span> =
 
 
== <span class="mw-headline" id="Brief_Introduction_2"><span class="mw-headline" id="Brief_Introduction_2"><span class="mw-headline" id="Brief_Introduction_2"><span class="mw-headline" id="Brief_Introduction_2">Brief Introduction</span></span></span></span> ==
 
 
Email notification is an important way for SPC to monitor the manufacturing line in real-time. When exceptions are found, SPC will send an email alert to associated employee or supervisor so that they can analyze the exception according to the alert email and other SPC tools and take appropriate measures, such as checking the production line, writing OCAPs, and stopping the line.
 
 
To access the Email Maintenance Page:
 
 
#Go to the Function List page and click the [[File:Email-maintenance-icon.png|email maintenance icon]] icon to enter the email maintenance module.
 
 
&nbsp;
 
 
'''Figure 129:&nbsp;Function List - E-mail Maintenance Icon'''
 
 
[[File:Function List - E-mail Maintenance Icon.png|700px|Function List - E-mail Maintenance Icon]]
 
 
&nbsp;
 
 
The Email Maintenance page is displayed:
 
 
&nbsp;
 
 
'''Figure 130: Email Maintenance'''
 
 
[[File:Email Maintenance.png|700px|Email Maintenance]]
 
 
From the Email Maintenance page the users are able to access the following functionalities:
 
 
*'''Email History'''
 
 
*'''Email Group'''
 
 
*'''Add Monitor Receive Email Rules'''
 
 
*'''Edit Monitor Receive Email Rules'''
 
 
*'''Enable'''
 
 
*'''Disable'''
 
 
*'''Search'''
 
 
For further information, see the next topics.
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Email_History"><span class="mw-headline" id="Email_History"><span class="mw-headline" id="Email_History"><span class="mw-headline" id="Email_History">Email History</span></span></span></span> ==
 
 
Email History allows users to add, edit, delete, and search for alert emails.
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Email_History_-_New_Alert_Email"><span class="mw-headline" id="Email_History_-_New_Alert_Email"><span class="mw-headline" id="Email_History_-_New_Alert_Email"><span class="mw-headline" id="Email_History_-_New_Alert_Email">Email History - New Alert Email</span></span></span></span> ===
 
 
To create a new email alert, in the Monitor Maintenance Page, select the New button.
 
 
&nbsp;
 
 
'''Figure 131: Email Maintenance - New Alert Email in the List'''
 
 
[[File:Email Maintenance - New Alert Email in the List.png|700px|Email Maintenance - New Alert Email in the List]]
 
 
The Add Email page is displayed:
 
 
Fill the Add Email page fields;
 
 
&nbsp;
 
 
'''Figure 132: Add Email in the list'''
 
 
[[File:Add Email in the list.png|700px|Add Email in the list]]
 
 
&nbsp;
 
 
'''Monitor Name''': Select a monitor from the available monitors'drop-down list. All listed available monitors here are created in the current SPC server. The recipients will receive alert emails from the monitor defined here.
 
 
'''To''': Input recipients of the alert email here. This field is mandatory.
 
 
'''Cc''': Input additional recipients here. This field is optional.
 
 
'''Description''': Write more information about the email if necessary. This field is optional.
 
 
'''Tip''': Users can input more than one email address with a semi-colon(;) between two email addresses. Select Save to save the configuration to SPC.
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Search_Email"><span class="mw-headline" id="Search_Email"><span class="mw-headline" id="Search_Email"><span class="mw-headline" id="Search_Email">Search Email</span></span></span></span> ===
 
 
In SPC, users can search existing alert email by keyword:
 
 
#Select the kind of keyword in the keyword category drop-down list.
 
#Enter the keyword in the keyword textbox, and click the [[File:Search-icon.png|search icon]] icon to search.
 
 
&nbsp;
 
 
'''Figure 133: E-mail List - Search'''
 
 
[[File:E-mail List - Search.png|700px|E-mail List - Search]]
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Email_Maintenance_-_Edit_Email_in_the_List"><span class="mw-headline" id="Email_Maintenance_-_Edit_Email_in_the_List"><span class="mw-headline" id="Email_Maintenance_-_Edit_Email_in_the_List"><span class="mw-headline" id="Email_Maintenance_-_Edit_Email_in_the_List">Email Maintenance - Edit Email in the List</span></span></span></span> ===
 
 
To edit an email
 
 
#Select the email record and click the [[File:Edit-icon.png|edit icon]] icon in the toolbar to open the Edit E-mail page.
 
 
&nbsp;
 
 
'''Figure 134: E-mail List - Edit'''
 
 
[[File:E-mail List - Edit.png|700px|E-mail List - Edit]]
 
 
&nbsp;
 
 
In the UpdateE-mail page, correct values in any of the four fields and save the changes.
 
 
&nbsp;
 
 
'''Figure 135: Update E-mail'''
 
 
[[File:Update E-mail.png|700px|Update E-mail]]
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Email_Maintenance_-_Delete_Email_in_the_List"><span class="mw-headline" id="Email_Maintenance_-_Delete_Email_in_the_List"><span class="mw-headline" id="Email_Maintenance_-_Delete_Email_in_the_List"><span class="mw-headline" id="Email_Maintenance_-_Delete_Email_in_the_List">Email Maintenance - Delete Email in the List</span></span></span></span> ===
 
 
To delete an email from the email list
 
 
#Select the email record and click the [[File:Delete-monitor-icon.png|delete monitor icon]] icon in the toolbar.
 
 
&nbsp;
 
 
'''Figure 136: E-mail List - Delete'''
 
 
[[File:E-mail List - Delete.png|700px|E-mail List - Delete]]
 
 
&nbsp;
 
<ol start="2">
 
<li>Choose '''Yes '''to delete the email.</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 137:&nbsp;Delete E-mail Confirmation Window'''
 
 
[[File:Delete E-mail Confirmation Window.png|Delete E-mail Confirmation Window]]
 
 
&nbsp;
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Example_of_an_Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email"><span class="mw-headline" id="Example_of_an_Alert_Email">Example of an Alert Email</span></span></span></span> ===
 
 
Alert emails from SPC will contain titles like “Alert message from SPC application’. Here is an example of an SPC alert email, which contains seven information fields (the red background area): Line, Monitor, Part Number, Location, Chart, Date, and Description.
 
 
&nbsp;
 
 
'''Figure 138: Alert E-mail Example'''
 
 
[[File:Alert email example.png|700px|Alert email example]]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance"><span class="mw-headline" id="Email_Group_Maintenance">Email Group Maintenance</span></span></span></span> ==
 
 
The Email Group Maintenance submodule allows users to add, edit, delete, and search email groups and also,&nbsp; associate emails to groups.<br/> See the next topics for further information.
 
 
'''Figure 139: Email Group Maintenance'''
 
 
[[File:Email Group Maintenance.png|700px|Email Group Maintenance.png]]<br/> &nbsp;
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group"><span class="mw-headline" id="Add_Email_Group">Add Email Group</span></span></span></span> ===
 
 
The first thing that the user needs to do is create a User Group with a name and description to create the Receive Emails Rules.
 
 
#Click on New button to create an email group;
 
 
&nbsp;
 
 
'''Figure 140: Email Group Maintenance - New'''
 
 
[[File:Email Group Maintenance New.png|700px|Email Group Maintenance New.png]]
 
 
&nbsp;
 
 
The Add Email Group page is displayed;
 
 
&nbsp;
 
 
'''Figure 141: Add Email Group'''
 
 
[[File:Add Email Group.png|700px|Add Email Group.png]]
 
 
Enter the Name and Description (mandatory fields) for the new email group; Select the [[File:Save button.png|save button.png]] to save the configuration to SPC.&nbsp;
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group"><span class="mw-headline" id="Edit_Email_Group">Edit Email Group</span></span></span></span> ===
 
 
To update the email group information:
 
 
#Click the Edit button to update the email group information;
 
 
&nbsp;
 
 
'''Figure 142: Email Group Maintenance - Edit'''
 
 
[[File:Email Group Maintenance - Edit.png|700px|Email Group Maintenance - Edit.png]] &nbsp;
 
 
Update Name or Description fields as needed.
 
 
&nbsp;
 
 
'''Figure 143: Update Email Group'''
 
 
[[File:Email Group Maintenance update email group.png|Email Group Maintenance update email group.png]] &nbsp;
 
 
Select the [[File:Save button.png|save button.png]] save the updates.
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email"><span class="mw-headline" id="Associate_Email">Associate Email</span></span></span></span> ===
 
 
After creating an email grouper, the user is able to associate as many as emails is needed.
 
 
#To associate emails to the group, select a group in the list and click on Associate Email;
 
 
&nbsp;
 
 
'''Figure 144: Email Group Maintenance - Associate Email'''
 
 
[[File:Email Group Maintenance-Associate Email.png|Email Group Maintenance-Associate Email.png]]
 
 
&nbsp;
 
 
The email list page is displayed and the user can add, edit, or delete emails.
 
 
&nbsp;
 
 
==== <span class="mw-headline" id="Add_Email_to_Group"><span class="mw-headline" id="Add_Email_to_Group"><span class="mw-headline" id="Add_Email_to_Group"><span class="mw-headline" id="Add_Email_to_Group">Add Email to Group</span></span></span></span> ====
 
 
To add an email to the group:
 
 
#From Email List page, click on New button:
 
 
&nbsp;
 
 
'''Figure 145: Add New Email to Group'''
 
 
[[File:Add New Email to Group.png|Add New Email to Group]] &nbsp;
 
 
The Add Email page is displayed:
 
 
&nbsp;
 
 
'''Figure 146: Add Email to Group'''
 
 
[[File:Add Email to Group.png|700px|Add Email to Group]]
 
 
Insert the email in the Email field (mandatory) and select the [[File:Save button.png|save button]] &nbsp;to save the email to the group.
 
 
==== <span class="mw-headline" id="Edit_Email"><span class="mw-headline" id="Edit_Email"><span class="mw-headline" id="Edit_Email"><span class="mw-headline" id="Edit_Email">Edit Email&nbsp;</span></span></span></span> ====
 
 
To edit an email,
 
 
#From Email List page, select the email and click the Edit button:
 
 
&nbsp;
 
 
'''Figure 147: Edit Email'''
 
 
[[File:Edit Email.png|Edit Email.png]] &nbsp;
 
 
The Update Email page is displayed;
 
 
&nbsp;
 
 
'''Figure 148: Update Email Page'''
 
 
[[File:Update Email Page.png|Update Email Page.png]]
 
 
&nbsp;
 
 
Update de email as needed and select and select the [[File:Save button.png|save button.png]] to save the updated information.<br/> &nbsp;
 
 
==== <span class="mw-headline" id="Delete_Email"><span class="mw-headline" id="Delete_Email"><span class="mw-headline" id="Delete_Email"><span class="mw-headline" id="Delete_Email">Delete Email</span></span></span></span> ====
 
 
To delete an email from the email list&nbsp;
 
 
1. Select the email record and click the [[File:Delete button.png|delete button.png]] in the toolbar.&nbsp;
 
 
&nbsp;
 
 
'''Figure 149:Delete Email'''
 
 
[[File:Delete Email.png|Delete Email.png]]
 
 
&nbsp;
 
 
Select Yes in the pop-up window to confirm the action.&nbsp;
 
 
&nbsp;
 
 
'''Figure 150:Delete Email Message'''
 
 
[[File:Delete Email Message.png|Delete Email Message.png]]
 
 
<br/> &nbsp;
 
 
=== <span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group"><span class="mw-headline" id="Search_Email_Group">Search Email Group</span></span></span></span> ===
 
 
Users can search existing email groups by keyword:&nbsp;
 
 
#Select the kind of keyword in the keyword category drop-down list (Name or Description).&nbsp;
 
#Enter the keyword in the keyword textbox, and click the [[File:Search button.png|search button.png]] to search.&nbsp;
 
 
&nbsp;
 
 
'''Figure 151: Email Group Maintenance - Search Email'''
 
 
[[File:Email Group Maintenance-Search Email.png|700px|Email Group Maintenance - Search Email.png]]
 
 
&nbsp;
 
 
=== <span class="mw-headline" id="Delete_Email_Group"><span class="mw-headline" id="Delete_Email_Group"><span class="mw-headline" id="Delete_Email_Group"><span class="mw-headline" id="Delete_Email_Group">Delete Email Group</span></span></span></span> ===
 
 
To delete an email group from the email group list&nbsp;
 
 
#Select the email group record and click the [[File:Xxx button.png|xxx button.png]] in the toolbar.&nbsp;
 
 
&nbsp;
 
 
'''Figure 152: Email Group Maintenance - Delete Email'''
 
 
[[File:Email Group Maintenance-Delete Email.png|700px|Email Group Maintenance - Delete Email.png]]
 
 
&nbsp;
 
<ol start="2">
 
<li>Choose Yes to delete the email.&nbsp;</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 153: Delete Email Group Message'''
 
 
[[File:Delete Email Group Message.png|Delete Email Group Message.png]]
 
 
&nbsp;
 
 
'''Figure 154: Email Group Maintenance - Tip'''
 
 
[[File:Email Group Maintenance-Tip.png|700px|Email Group Maintenance-Tip.png]]<br/> &nbsp;
 
 
'''Figure 155: Tip Message'''
 
 
[[File:Tip Message.png|Tip Message.png]]
 
 
<br/> &nbsp;
 
 
== <span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule"><span class="mw-headline" id="New_Email_Rule">New Email Rule</span></span></span></span> ==
 
 
&nbsp;
 
 
This functionality allows users to create email rules as needed.
 
 
To create a new email Rule, in the Email Maintenance Page, select the New button.
 
 
&nbsp;
 
 
'''Figure 156: Email Maintenance - New Email Rule'''
 
 
[[File:Email Group Maintenance - New Email Rule.png|700px|Email Group Maintenance - New Email Rule.png]]
 
 
&nbsp;
 
 
The Add Monitor Receive Email Rule page is displayed:
 
 
&nbsp;
 
 
'''Figure 157: Email Maintenance - Add Monitor Receive Email Rule'''
 
 
[[File:Email Group Maintenance-Add Monitor Receive Email Rule.png|Email Group Maintenance - Add Monitor Receive Email Rule.png]] &nbsp;
 
 
From this page, the user needs to enter the Name, Description, and associate an Email Group (mandatory fields), created in the Email Group functionality.
 
 
After this, the rules can be created as needed by: '''Shop Floor ID''', '''Part Number''', '''Family ID''', '''Process''', '''Location''', '''Family ID,''' and '''Monitor Group'''.&nbsp;
 
 
Click on the '''Submit '''button to save the information.
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Edit_Email_Rule"><span class="mw-headline" id="Edit_Email_Rule"><span class="mw-headline" id="Edit_Email_Rule"><span class="mw-headline" id="Edit_Email_Rule">Edit Email Rule</span></span></span></span> ==
 
 
&nbsp;
 
 
This functionality allows users to edit email rules as needed.
 
 
To edit a new email Rule, in the Email Maintenance Page, select the Edit button.
 
 
&nbsp;
 
 
'''Figure 158: Email Maintenance - Edit Email Rule'''
 
 
[[File:Email Group Maintenance-Edit Email Rule.png|700px|Email Group Maintenance - Edit Email Rule.png]] &nbsp;
 
 
The Edit Monitor Receive Email Rule page is displayed:
 
 
&nbsp;
 
 
'''Figure 159: Email Maintenance - Edit Monitor Receive Email Rule'''
 
 
[[File:Email Group Maintenance-Edit Monitor Receive Email Rule.png|Email Group Maintenance - Edit Monitor Receive Email Rule.png]]
 
 
Edit the fields as needed and click on Submit to save the information.
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule"><span class="mw-headline" id="Delete_Email_Rule">Delete Email Rule</span></span></span></span> ==
 
 
To delete an email Rule from the list&nbsp;
 
 
#Select the email rule record and click the [[File:Delete button.png|delete button.png]] in the toolbar.&nbsp;
 
 
&nbsp;
 
 
'''Figure 160: Email Maintenance - Delete Email Rule'''
 
 
[[File:Email Group Maintenance-Delete Email Rule.png|700px|Email Group Maintenance - Delete Email Rule.png]]
 
 
&nbsp;
 
 
Select Yes in the pop-up window to confirm the action.&nbsp;
 
 
&nbsp;
 
 
'''Figure 161: Email Maintenance - Delete Email Rule Message'''
 
 
[[File:Email Group Maintenance-Delete Email Rule Message.png|Email Group Maintenance - Delete Email Rule Message.png]]
 
 
&nbsp;
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Enable_Email_Rule"><span class="mw-headline" id="Enable_Email_Rule"><span class="mw-headline" id="Enable_Email_Rule"><span class="mw-headline" id="Enable_Email_Rule">Enable Email Rule</span></span></span></span> ==
 
 
Enabling Email Rule restores an email rule record from disabled status. To do this,&nbsp;
 
 
#Select the email rule record from the disabled data list, then click the [[File:Enable button.png|enable button.png]] in the toolbar.&nbsp;
 
 
&nbsp;
 
 
'''Figure 162: Enable Email Rule'''
 
 
[[File:Enable Email Rule.png|700px|Enable Email Rule.png]] &nbsp;
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Disable_Email_Rule"><span class="mw-headline" id="Disable_Email_Rule"><span class="mw-headline" id="Disable_Email_Rule"><span class="mw-headline" id="Disable_Email_Rule">Disable Email Rule</span></span></span></span> ==
 
 
&nbsp;
 
 
To disable an email rule
 
 
Select an email rule and click the [[File:Xxxxx.png|xxxxxx.png]] in the toolbar.&nbsp;
 
 
&nbsp;
 
 
'''Figure 163: Disable Email Rule'''
 
 
[[File:Disable Email Rule.png|700px|Disable Email Rule.png]] &nbsp;
 
 
Choose Yes in the pop-up confirm window.&nbsp;
 
 
&nbsp;
 
 
'''Figure 164: Disable Confirmation Message'''
 
 
[[File:Disable Confirmation Message.png|Disable Confirmation Message.png]]
 
 
&nbsp;
 
 
= <span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance"><span class="mw-headline" id="Location_Family_Maintenance">Location Family Maintenance</span></span></span></span> =
 
 
== <span class="mw-headline" id="Brief_Introduction_3"><span class="mw-headline" id="Brief_Introduction_3"><span class="mw-headline" id="Brief_Introduction_3"><span class="mw-headline" id="Brief_Introduction_3">Brief Introduction</span></span></span></span> ==
 
 
The location family is a collection of locations. One location family consists of one or more locations, which can be derived from different processes and departments. The authorized user can create, search, edit, disable, delete, and enable location family.
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family"><span class="mw-headline" id="Create_Location_Family">Create Location Family</span></span></span></span> ==
 
 
To create a new location family
 
 
#Click the [[File:Function List - Location Family Maintenance.png|location family icon]] icon on the Function List page.
 
 
&nbsp;
 
 
'''Figure 165: Function List - Location Family Maintenance'''
 
 
[[File:Function List-Location Family Maintenance.png|700px|Location Family Maintenance.png]]
 
 
&nbsp;
 
<ol start="2">
 
<li>&nbsp;On-Location Family List page, click [[File:New-server.png|new server icon]] button in the toolbar.</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 166: Location Family List Page - New Icon'''
 
 
[[File:Location Family List Page - New Icon.png|700px|Location Family List Page - New Icon]]
 
 
&nbsp;
 
<ol start="3">
 
<li>Select '''Process,&nbsp;'''or '''Department.'''</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 167: Location Family'''
 
 
[[File:Location Family.png|700px|Location Family]]
 
 
&nbsp;
 
<ol start="4">
 
<li>Enter values in the Location textbox to filter locations. If a user changes values of the Location textbox, its instant search function activates, and the SPC system automatically searches matching locations from the locations that belong to the selected department, displaying matching locations in the Location selection box.</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 168: Location Textbox'''
 
 
[[File:Location Textbox.png|700px|Location Textbox]]
 
 
&nbsp;
 
<ol start="5">
 
<li>Select a location and click the [[File:Right-arrow.png|right arrow icon]] button to add locations from the left panel to the right panel. More than one location can be selected at a time.</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 169: Add Location'''
 
 
[[File:Add Location.png|700px|Add Location]]
 
 
&nbsp;
 
<ol start="6">
 
<li>Lastly, click the Save button to save your data to SPC.</li>
 
</ol>
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family"><span class="mw-headline" id="Search_Location_Family">Search Location Family</span></span></span></span> ==
 
 
SPC enables users to search for location family by keyword and status. To search for a location family
 
 
#Go to the Location Family List page, select a keyword category (the green frame area in Figure 111), and input a keyword in the text input box (the red frame area in Figure 111).
 
#Select a location family status (the blue frame area in Figure 111) and click the [[File:Search-icon.png|search icon]] icon.
 
 
&nbsp;
 
 
'''Figure 170: Search Location Family'''
 
 
[[File:Search Location Family.jpg|Search Location Family]]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Edit_Location_Family"><span class="mw-headline" id="Edit_Location_Family"><span class="mw-headline" id="Edit_Location_Family"><span class="mw-headline" id="Edit_Location_Family">Edit Location Family</span></span></span></span> ==
 
 
To edit a location family
 
 
#Select a location family from the list, then click the [[File:Edit-icon.png|edit icon]] icon in the toolbar. The Edit Location Family page is displayed.
 
 
&nbsp;
 
 
'''Figure 171: Location Family List - Edit'''
 
 
[[File:Location Family List - Edit.png|700px|Location Family List - Edity]]
 
 
&nbsp;
 
<ol start="2">
 
<li>On Edit Location Family page, edit any field you want, and save the changes.</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 172: Edit Location Family Page'''
 
 
[[File:Edit Location Family Page.png|700px|Edit Location Family Page]]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Disable_Location_Family"><span class="mw-headline" id="Disable_Location_Family"><span class="mw-headline" id="Disable_Location_Family"><span class="mw-headline" id="Disable_Location_Family">Disable Location Family</span></span></span></span> ==
 
 
To disable a location family
 
 
Select a location family and click the [[File:Disable-monitor-icon.png|disable monitor icon]] icon in the toolbar.
 
 
&nbsp;
 
 
'''Figure 173: Location Family List - Delete'''
 
 
[[File:Location Family List - Delete.png|700px|Location Family List - Delete]]
 
 
&nbsp;
 
 
Choose '''Yes '''in the pop-up confirm window.
 
 
&nbsp;
 
 
'''Figure 174: Disable Confirmation Window'''
 
 
[[File:Disable Confirmation Window.png|Disable Confirmation Window]]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Delete_Location_Family"><span class="mw-headline" id="Delete_Location_Family"><span class="mw-headline" id="Delete_Location_Family"><span class="mw-headline" id="Delete_Location_Family">Delete Location Family</span></span></span></span> ==
 
 
To delete a location family
 
 
#Select the location family and click '''Disable'''.
 
#&nbsp;Search the disabled location family list for the disabled location family, select the location family, and click '''Delete'''.
 
 
&nbsp;
 
 
'''Figure 175: Location Family List - Delete'''
 
 
[[File:Location Family List - Delete.png|700px|Location Family List - Delete]]
 
 
&nbsp;
 
<ol start="3">
 
<li>Click '''Yes '''to confirm the action.</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 176: Delete Confirmation Message'''
 
 
[[File:Delete Confirmation Message.png|Delete Confirmation Message]]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Enable_Location_Family"><span class="mw-headline" id="Enable_Location_Family"><span class="mw-headline" id="Enable_Location_Family"><span class="mw-headline" id="Enable_Location_Family">Enable Location Family</span></span></span></span> ==
 
 
To enable a location family
 
 
#Select a location family and click the [[File:Enable-monitor-icon.png|enable data icon]] icon in the toolbar.
 
 
&nbsp;
 
 
'''Figure 177: Location Family List - Enable'''
 
 
[[File:Location Family List - Enable.png|700px|Location Family List - Enable]]
 
<ol start="2">
 
<li>Choose '''Yes''' in the pop-up window.</li>
 
</ol>
 
 
&nbsp;
 
 
'''Figure 178: Enable Confirmation Message'''
 
 
[[File:Enable Confirmation Message.png|Enable Confirmation Message]]
 
 
&nbsp;
 
 
= <span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance"><span class="mw-headline" id="System_Log_Maintenance">System Log Maintenance</span></span></span></span> =
 
 
== <span class="mw-headline" id="Brief_Introduction_4"><span class="mw-headline" id="Brief_Introduction_4"><span class="mw-headline" id="Brief_Introduction_4"><span class="mw-headline" id="Brief_Introduction_4">Brief Introduction</span></span></span></span> ==
 
 
Some important system events, such as data modification and stopping a monitor, will be automatically added to SPC system log. System log plays an important role in system security. Users can analyze the system log and decide to take appropriate measures, like data recovery and file backup, to defend the system. In the SPC system, authorized users can search, view, and delete system logs.
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log"><span class="mw-headline" id="Search_and_View_System_Log">Search and View System Log</span></span></span></span> ==
 
 
On the Function List page, users can click the [[File:System-log-icon.png|system log icon]] icon to navigate to the System Log page.
 
 
&nbsp;
 
 
'''Figure 179: Function List - System Log Maintenance'''
 
 
[[File:Function List - System Log Maintenance.png|700px|Function List - System Log Maintenance]]
 
 
In the System Log page, users can search the system log by time frame or by event owner:
 
 
&nbsp;
 
 
'''Figure 180: System Log Page'''
 
 
[[File:System Log Page.png|700px|System Log Page]]
 
 
&nbsp;
 
 
1. Input event owner in the '''Performed by''' textbox or choose a time frame and click the [[File:Search-icon.png|search icon]] icon in the toolbar.
 
 
&nbsp;
 
 
'''Figure 181: System Log - Search'''
 
 
[[File:SYstem Log - Search.png|system Log - Search]]
 
 
&nbsp;
 
 
2. System log list table structure contains three columns - Date, Performed By and Operation:
 
 
*'''Date''': when did the operation take place
 
*'''Performed By''': who did the operation, user or system
 
 
*'''Operation''': what is the operation
 
 
&nbsp;
 
 
'''Figure 182: System Log Search Results'''
 
 
[[File:System Log Search Results.png|700px|System Log Search Results]]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Delete_System_Log"><span class="mw-headline" id="Delete_System_Log"><span class="mw-headline" id="Delete_System_Log"><span class="mw-headline" id="Delete_System_Log">Delete System Log</span></span></span></span> ==
 
 
Every 24 hours, SPC automatically deletes system logs created 3 months before. Authorized users can delete logs manually via SPC UI. Users can delete logs individually or in batches.
 
 
&nbsp;
 
 
'''Figure 183: System Log - Delete'''
 
 
[[File:System Log - Delete.png|700px|System Log - Delete]]
 
 
&nbsp;
 
 
'''Figure 184: Delete Confirmation Message'''
 
 
[[File:System Log Delete Confirmation Message.png|700px|Delete Confirmation Message.png]]
 
 
= <span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance"><span class="mw-headline" id="SPC_System_Parameter_Maintenance">SPC System Parameter Maintenance</span></span></span></span> =
 
 
== <span class="mw-headline" id="Brief_Introduction_5"><span class="mw-headline" id="Brief_Introduction_5"><span class="mw-headline" id="Brief_Introduction_5"><span class="mw-headline" id="Brief_Introduction_5">Brief Introduction</span></span></span></span> ==
 
 
Authorized users are allowed to set general system parameters according to their local plants, manufacturing lines, or other special needs. This part of system parameters configuration affects the performance of the current SPC server, caution is necessary when defining the parameter values.
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Maintain_SPC_System_Parameters"><span class="mw-headline" id="Maintain_SPC_System_Parameters"><span class="mw-headline" id="Maintain_SPC_System_Parameters"><span class="mw-headline" id="Maintain_SPC_System_Parameters">Maintain SPC System Parameters</span></span></span></span> ==
 
 
Users may access SPC System Parameters Maintenance by selecting the&nbsp;[[File:Sys-para-icon.png|system parameters maintenance icon]] icon on the Function List page.
 
 
&nbsp;
 
 
'''Figure 185: Function List - SPC System Parameter Maintenance'''
 
 
[[File:Function List - SPC System Parameter Maintenance.png|700px|Function List - SPC System Parameter Maintenance]]
 
 
<br/> On SPC System Parameter page, eleven fields are displayed and the user can move their mouse over the [[File:Info-icon.png|more info icon]] icon to learn more information about the labels. See below the fields description:
 
 
&nbsp;
 
 
'''Figure 186: SPC System Parameter Page'''
 
 
[[File:SPC System Parameter1.png|700px|SPC System Parameter]]
 
 
An explanation of the fields in the above screenshot follows:&nbsp;
 
 
'''Interval of collecting data (second)''': During real-time monitoring, each monitor will periodically collect data from SFDC archive database or other data source, the setting determines how often each monitor collects data.
 
 
'''Interval of deleting log (hour)''': There is one background job (thread) responsible to periodically delete the system log, this setting determines how often the background job deletes some system logs.
 
 
'''Time of log saved (month)''': System log will not be saved forever, a too old log will be deleted by background job, this setting determines how long the system log is saved in the database.
 
 
'''The interval between lock reviews (second)''': How often the background job review lock (or called MFG hold request to determine if one waiting lock should be sent to to the SFDC (MES)
 
 
'''Display family ID in chart''': selecting this checkbox the Family ID is displayed on SPC chart.
 
 
'''Start time of data collection (month)''': After one monitor is created, this monitor related data can be retrieved from past time, this setting determines how old data can be when retrieved by monitor. The default value is 3 months.&nbsp;
 
 
'''Hide monitors with no data in chart in the past (hours)''': It allows users to filter out those monitors that have no new data coming in during the past settable hours. Users can input a positive number between 1 to 168 in the textbox. The default value for this textbox is 24. To view the effect, you can check the [http://hsvmeswiki.sanmina-sci.com/mes_wiki/extensions/FCKeditor/fckeditor/editor/fckeditor.html?InstanceName=wpTextbox1&Toolbar=Wiki#Hide_Inactive_Monitors Hide Inactive Monitors] feature on the Monitor List page.&nbsp;
 
 
'''Disable monitors with no data in chart in the past (hours)''': If a user enables this checkbox, the SPC will automatically disable those monitors that have no new data during the past settable hours. By default, this checkbox is enabled. The hours' quantity textbox next to it has a default value of 24 (hours). This textbox allows positive integers from 1 to 168.&nbsp;
 
 
'''Enable Previous SPC Hold function''': Previous Hold function will be invoked in the following scenario: after a part number was put on SPC Hold by SPC for the settable number of consecutive defect codes within a set time limit, displays ‘PREVIOUS SPC HOLD’ in NetDC rather than issuing an immediate SPC holds.&nbsp;
 
 
'''Note:'''
 
 
*If a monitor is stopped, disabled, or deleted, the Previous Hold function of this monitor will be automatically turned off as well.&nbsp;
 
*Users must enable the Send MFG hold to SFDC / MDS checkbox in [http://hsvmeswiki.sanmina-sci.com/mes_wiki/extensions/FCKeditor/fckeditor/editor/fckeditor.html?InstanceName=wpTextbox1&Toolbar=Wiki#Create_SPC_Server Add Server Information] page first, before enabling the Enable Previous SPC Hold function checkbox.
 
 
Currently, this function only supports the monitors in which group was defined by SFDC ( see in image 160). If the group defined by MDS, it will not support this function.
 
 
'''Note:'''
 
 
#'''# of running monitor''' field was deactivated. It was used to limit the number of monitors running, to avoid too many threads causing the program to freeze. Some plants have requested to create thousands of monitors, and the current system does not support them. However, after the Data Engine enhancement, the retrieval method in SPC was redesigned, solving this issue.
 
#'''# of active thread''': the #of the active thread is no longer used in SPC System Parameter. After Data engine enhancement.&nbsp;The retrieval method of SPC was redesigned. Each site retains the main thread to calculate all monitors with a delay of fewer than 30 mins, another 5 threads are allocated for calculating monitors with historical data or a delay of more than 30 minutes.
 
 
&nbsp;
 
 
'''Figure 187: Send MFG Hold Request by SFDC'''
 
 
[[File:Send MFG Hold Request by SFDC.png|700px|send MFG Hold Request by SFDC]]
 
 
&nbsp;
 
 
Users can also restore the system parameters from previous prior configurations. To do this, select the '''Select one from the last 3 changes'''&nbsp;drop-down list and select one from the list. The values in the text input boxes will be automatically restored.
 
 
'''Email Title''': to set the title of the alarm email.
 
 
'''MESR URL Template''': This field is to set a URL link to the MES Web. The URL template is plantcode-mesweb-med.42-q.com or plantcode-mesweb-med-uat.42-q.com. Hence the original HTTP URL template is not suitable as a fixed URL link.
 
 
&nbsp;
 
 
After all, configurations are done, remember to click the &nbsp;[[File:Save button.png|save button]] icon. If saving is okay, the user can see the message 'Configurations are successfully saved and will be immediately effective'. If there is a malfunction, users will see the error message 'Configurations are not saved, please try again or contact administrator.'&nbsp;
 
 
&nbsp;
 
 
= <span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance"><span class="mw-headline" id="Lock_Maintenance">Lock Maintenance&nbsp;</span></span></span></span> =
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Brief_Introduction_6"><span class="mw-headline" id="Brief_Introduction_6"><span class="mw-headline" id="Brief_Introduction_6"><span class="mw-headline" id="Brief_Introduction_6">Brief Introduction&nbsp;</span></span></span></span> ==
 
 
This functionality allows the user to unlock hold, search lock record by time range and export hold records in one page.
 
 
&nbsp;
 
 
== <br/> <span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance"><span class="mw-headline" id="Maintain_SPC_Lock_Maintenance">Maintain SPC Lock Maintenance&nbsp;</span></span></span></span> ==
 
 
Users may access SPC Lock Maintenance by selecting the&nbsp;[[File:Lock button.png|lock button]] icon on the Function List page.&nbsp;
 
 
&nbsp;
 
 
'''Figure 188: Function List - SPC Lock Maintenance'''
 
 
[[File:Function List - SPC Lock Maintenance.png|700px|Function List - SPC Lock Maintenance]]
 
 
Users may view lock records and unlock existing locks as well.&nbsp;
 
 
&nbsp;
 
 
&nbsp;
 
 
== <span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2"><span class="mw-headline" id="View_Lock_2">View Lock&nbsp;</span></span></span></span> ==
 
 
1. To view lock, from the Monitor List, select a monitor and click the [[File:Lock icon.png|lock icon]] in the toolbar. The Lock List page displays.&nbsp;
 
 
&nbsp;
 
 
'''Figure 189: Lock Maintenance - Lock List'''
 
 
[[File:Lock Maintenance - Lock List.png|700px|Lock Maintenance - Lock List]]
 
 
Function List - SPC System Parameter Maintenance &nbsp;
 
 
Beginning with SPC 3.2, the lock mechanism has been modified so that only the Pareto chart can send MFG hold requests to SFDC / MDS. Users can view locks in different status as long as different values are selected in the lock status drop-down list. For example, if a user wants to find locked locks, select LOCKED from the lock status drop-down list, and click the [[File:Search button.png|search button]] in the toolbar.&nbsp;
 
 
'''Figure 190'''''': Lock Search Drop-down'''
 
 
[[File:Lock Search Drop-down.png|Lock Search Drop-down]]
 
 
There are four statuses for locks: WAITING, LOCKED, UNLOCKED, and CANCELED. The CANCELED status was added to SPC 3.2.&nbsp;
 
 
*'''WAITING''': the lock that is waiting to be sent to MDS / SFDC. When the out-of-control case is detected, SPC will wait some minutes before sending the MFG hold to MDS / SFDC until it reaches the number of minutes defined by '''Send MFG to hold requests after * minutes''' field in the&nbsp;[http://hsvmeswiki.sanmina-sci.com/mes_wiki/extensions/FCKeditor/fckeditor/editor/fckeditor.html?InstanceName=wpTextbox1&Toolbar=Wiki#Actions Actions] section. During this period, the lock is in WAITING status.&nbsp;
 
*'''LOCKED''': MFG hold has been sent, associated location or process has been locked and OCAP has not been processed.&nbsp;
 
*'''UNLOCKED''': User input OCAPs to on-hold&nbsp;associated location or process, then the locked lock becomes UNLOCKED.&nbsp;
 
 
CANCELED: This lock status is a new status as of SPC 3.2. For a better understanding of this status, consider the following scenario: A SPC monitor was created for Pareto Chart that 3 defect codes of the same type within 10 minutes will trigger the exception, and MFG hold will be sent to SFDC / MDS 5 minutes later. A few minutes later, a first MFG hold was triggered, if a second MFG hold was triggered during the first hold’s delay sending time in the new lock mechanism, the second hold will not be sent to SFDC / MDS, and the status of the second MFG hold is CANCELED.
 
 
&nbsp;
 
 
= <span class="mw-headline" id="SPC_TV_Portlet"><span class="mw-headline" id="SPC_TV_Portlet"><span class="mw-headline" id="SPC_TV_Portlet"><span class="mw-headline" id="SPC_TV_Portlet">SPC TV Portlet</span></span></span></span> =
 
 
Like SPC portlet, SPC TV portlet is another component of the SPC system. SPC TV enables users can view SPC control charts in any combination in one page through some simple configuration so that users can learn the latest status of any line or location in real-time.
 
 
== <span class="mw-headline" id="Add_SPC_TV_Portlet"><span class="mw-headline" id="Add_SPC_TV_Portlet"><span class="mw-headline" id="Add_SPC_TV_Portlet"><span class="mw-headline" id="Add_SPC_TV_Portlet">Add SPC TV Portlet</span></span></span></span> ==
 
 
After the SPC portlet is installed, click the SPC TV sub-menu on the left side, move the cursor over the '''Add '''selection menu on the top left corner, and choose More from the drop-down menu.
 
 
&nbsp;
 
 
'''Figure 191: SPC&nbsp;TV&nbsp;Add'''
 
 
[[File:SOP-5-I-MES0069-C SPC TV Add.jpg|RTENOTITLE]]
 
 
&nbsp;
 
 
From the MES menu tree, select SPC, then select TV from the SPC menu tree. Select '''Add.'''&nbsp;An SPC TV portlet has been added to the page.
 
 
&nbsp;
 
 
'''Figure 192: SPC&nbsp;Menu Tree'''
 
 
[[File:Add tv 3.1.3.png|RTENOTITLE]]
 
 
&nbsp;
 
 
NOTE: By default, there is only one SPC TV page on the left navigation menu, and only one SPC TV portlet added in the page. Users do not have the permissions to add an SPC TV page or SPC TV portlet. If &nbsp;a user wants to make such an addition they must submit a Work Request and have MES Support team to make the addition.
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Set_Page_Layout"><span class="mw-headline" id="Set_Page_Layout"><span class="mw-headline" id="Set_Page_Layout"><span class="mw-headline" id="Set_Page_Layout">Set Page Layout</span></span></span></span> ==
 
 
Move the cursor over the Manage selection menu and select the Page Layout sub-menu from the drop-down list.
 
 
&nbsp;
 
 
'''Figure 193: Manage Menu'''
 
 
[[File:Manage layout.png|RTENOTITLE]]
 
 
&nbsp;
 
 
In the floating panel, 11 layout templates are available, you can select one and click the Save button to apply the layout to your page. By default, the 2 Columns (30/70) layout template is selected.
 
 
&nbsp;
 
 
'''Figure 194: Page Layout Menu'''
 
 
[[File:Layout templates 3.1.3.png|RTENOTITLE]]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Configure_Preferences"><span class="mw-headline" id="Configure_Preferences"><span class="mw-headline" id="Configure_Preferences"><span class="mw-headline" id="Configure_Preferences">Configure Preferences</span></span></span></span> ==
 
 
Users must perform some simple configuration before SPC TV portlet shows SPC control charts properly. Click the [[File:Spanner icon 3.1.3.png|RTENOTITLE]] icon from the SPC TV portlet controls bar, and select Preferences from the drop-down menu.
 
 
&nbsp;
 
 
'''Figure 195: SPC&nbsp;TV&nbsp;- Preferences'''
 
 
[[File:Tv preferences menu 3.1.3.png|RTENOTITLE]]
 
 
&nbsp;
 
 
Select available a server, monitor, and chart from each drop-down selection box. Complete the remaining parameters and click '''Save'''.
 
 
&nbsp;
 
 
'''Figure 196: Preferences Page'''
 
 
[[File:Tv preferences 1.0.png|700px|Tv preferences 1.0.png]]
 
 
Some of the fields are explained as follow:
 
 
'''Select SPC Server''': the SPC server that has been defined in the Server Information portlet
 
 
'''Monitor Group''': Currently SPC monitors are grouped into two categories according to the data source: MDS and SPI. You can select a monitor group name here.
 
 
'''Monitor''': the monitor that you've created under the selected monitor group in SPC portlet
 
 
'''Chart''': the control charts that you've configured in the selected monitor. Please note that the Pareto chart and Yield chart will not be displayed in this field even if you've configured them in SPC monitor
 
 
'''Number of point''': the maximum points that will show on the selected chart
 
 
'''Refresh(min)''': every xx minutes SPC TV will refresh for new data
 
 
'''Display counter''': whether or not shows the countdown timer on SPC TV portlet (on top right corner)
 
 
'''Size''': the size of SPC TV portlet, you can either select a fixed size or define your own size
 
 
<br/> '''Tip''': For details about how to get the best display effect under different screen resolutions, you can refer to [https://docs.google.com/a/sanmina.com/document/d/1RzgRMJIB418OqGWaM0ncLAfPQDsbAQAOqIIFkkip41w/edit# SPC TV Configuration Guide]
 
 
&nbsp;
 
 
== <span class="mw-headline" id="Exceptional_Icons"><span class="mw-headline" id="Exceptional_Icons"><span class="mw-headline" id="Exceptional_Icons"><span class="mw-headline" id="Exceptional_Icons">Exceptional Icons</span></span></span></span> ==
 
 
*If there is no setting for the SPC TV portlet, it displays a gear icon
 
 
[[File:Gear icon 3.1.3.png|RTENOTITLE]]
 
 
&nbsp;
 
 
*If there is no data, SPC TV portlet displays a question mark icon
 
 
[[File:Question icon 3.1.3.png|RTENOTITLE]]
 
 
&nbsp;
 
 
*If the connection times out, SPC TV portlet displays an exclamation mark icon
 
 
[[File:Exclamation icon 3.1.3.png|RTENOTITLE]]
 
 
&nbsp;
 
 
 
= <span class="mw-headline" id="Roles_.EF.BC.86_Permissions"><span class="mw-headline" id="Roles_.EF.BC.86_Permissions"><span class="mw-headline" id="Roles_.EF.BC.86_Permissions"><span class="mw-headline" id="Roles_.EF.BC.86_Permissions"><span class="mw-headline" id="Roles_.EF.BC.86_Permissions">Roles & Permissions</span></span></span></span></span> =
 
 
{| border="1" cellpadding="1" cellspacing="1" width="100%"
 
|-
 
! bgcolor="#cccccc" scope="col" | Roles→<br/> Permissions↓
 
! bgcolor="#99ccff" scope="col" | SPC_Corp_Support
 
! bgcolor="#99ccff" scope="col" | SPC_Plant_Admin
 
! bgcolor="#99ccff" scope="col" | SPC_Plant_Manager
 
! bgcolor="#99ccff" scope="col" | SPC_Plant_User
 
! bgcolor="#ccccff" scope="col" | *SPC_Plant_Operator
 
|-
 
| bgcolor="#9BAA95" | '''SPC'''
 
| &nbsp;
 
| &nbsp;
 
| &nbsp;
 
| &nbsp;
 
| &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Add/Edit/Delete Monitor
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Start/Stop Monitor
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Disable/Enable Monitor
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Add/Edit/Delete Monitor Group
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Input/Edit Data
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
|-
 
| bgcolor="#D3DADD" | Add/Edit/Delete Email
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Delete Log
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Edit OCAP
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Disable/Enable Data
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Add/Edit/Delete Location Family
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Disable/Enable Location Family
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Edit System Configuration/Global System Configuration
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Unlock
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | View
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
|-
 
| bgcolor="#D3DADD" | Add to Page
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Configuration
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#9BAA95" | '''SPC Server Information'''
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Add/Edit/Delete Server
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | View
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
|-
 
| bgcolor="#D3DADD" | Add to Page
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|-
 
| bgcolor="#D3DADD" | Configuration
 
| align="center" valign="middle" | [[File:Tick-icon.png|center|Tick-icon.png]]
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
| align="center" valign="middle" | &nbsp;
 
|}
 
 
&nbsp;
 
 
'''Notification''':
 
 
*‘SPC_Plant_Operator’ is for plant E68 only.
 
 
= <span class="mw-headline" id="Glossary"><span class="mw-headline" id="Glossary"><span class="mw-headline" id="Glossary"><span class="mw-headline" id="Glossary">Glossary</span></span></span></span> =
 
 
'''1. MFG hold''': MFG hold is short for manufacturing hold. SPC sends MFG hold to MDS or SFDC to stop the manufacturing line. It is another action SPC can take when a point is out of control limit.
 
 
'''2. MDS''': Short for Manufacturing Data System.
 
 
'''3. SFDC''': The SFDC (Shop Floor Data Collection) System is the main software/hardware system used by 42Q for production control and the collection of manufacturing data.
 
 
'''4. Exception''': SPC considers some out-of-control caA valid group here means the group oses as an exception based on the rules you selected when configuring monitor parameters.
 
 
'''5. Valid group''': It means the data that is in the normal scope. On SPC control charts, a valid group of data points is plotted between the UCL and LCL.
 
 
'''6. DPMO''': Short for Defects Per Million of Opportunities.
 
 
'''7. OCAP''': Short for Out of Control Action Plan.
 
 
'''8. Ext JS''': Ext JS JavaScript Framework. Ext JS is a pure JavaScript application framework for building interactive web applications using techniques such as Ajax, DHTML and DOM scripting.
 
 
&nbsp;
 
 
&nbsp;
 
 
= <span class="mw-headline" id="Document_Revision_History"><span class="mw-headline" id="Document_Revision_History"><span class="mw-headline" id="Document_Revision_History"><span class="mw-headline" id="Document_Revision_History"><span class="mw-headline" id="Document_Revision_History">Document Revision History</span></span></span></span></span> =
 
 
{| border="1" class="wikitable"
 
|-
 
! style="text-align: center; background-color: rgb(0, 168, 168); width: 50px;" | Date
 
! style="text-align: center; background-color: rgb(0, 168, 168); width: 82px;" | Author
 
! style="text-align: center; background-color: rgb(0, 168, 168);" | Title
 
! style="text-align: center; background-color: rgb(0, 168, 168); width: 85px;" | Version
 
! style="text-align: center; background-color: rgb(0, 168, 168); width: 523px;" | Change Reference
 
! style="text-align: center; background-color: rgb(0, 168, 168);" | Approved by
 
|-
 
| style="width: 50px;" | 02/01/2014
 
| style="width: 82px;" | Elton Wang
 
| Technical Writer
 
| style="width: 85px;" | v 1.0
 
| style="width: 523px;" | Initial Release.
 
| &nbsp;
 
|-
 
| style="width: 50px;" | 04/28/2016
 
| style="width: 82px;" | Dane Parker
 
| Technical Writer
 
| style="width: 85px;" | v 1.0
 
| style="width: 523px;" | Formatted to 42Q.
 
| &nbsp;
 
|-
 
| style="width: 50px;" | 04/02/2018
 
| style="width: 82px;" | Elaine Fonaro
 
| Technical Writer
 
| style="width: 85px;" | v 1.0
 
| style="width: 523px;" | Applied new Template for the format.
 
| &nbsp;
 
|-
 
| style="width: 50px;" | 09/13/2019
 
| style="width: 82px;" | Elaine Fonaro
 
| Technical Writer
 
| style="width: 85px;" | v 2.0
 
| style="width: 523px;" |
 
- Added an Email title configuration to set the title of the alarm email;
 
 
- Added a MESR URL Template to set URL link to MESWEB;
 
 
| &nbsp;
 
|-
 
| style="width: 50px;" | 11/11/2019
 
| style="width: 82px;" | Elaine Fonaro
 
| Technical Writer
 
| style="width: 85px;" | v 2.0
 
| style="width: 523px;" |
 
- Updated Functionalities and the majority of images;
 
 
-Added Lock Functionality;
 
 
- Added Email Maintenance Functionality;
 
 
- Removed SPC System Parameter Maintenance Icon. This&nbsp;
 
 
the feature has been merged;
 
 
| Sunny Xiong
 
|-
 
| style="width: 50px;" | 12/27/2019
 
| style="width: 82px;" | Elaine Fonaro
 
| Technical Writer
 
| style="width: 85px;" | v 1.2.22
 
| style="width: 523px;" |
 
- Number of running monitor field was deactivated and removed from the SPC System Parameter page.
 
 
- Updated images 83, 84, 85, 86, 88 and 94;
 
 
- Added new description for Function List - SPC System Parameter Maintenance;
 
 
| Sunny Xiong
 
|-
 
| style="width: 50px;" | 03/27/2020
 
| style="width: 82px;" | Elaine Fonaro
 
| Technical Writer
 
| style="width: 85px;" | v. 1.2.23
 
| style="width: 523px;" |
 
1. Add Dot Line Chart in SPC
 
 
2. Support create and edit&nbsp; monitors in batch
 
 
3. Continuous charts support sampling(Current SPC only supports full inspection)
 
 
4. Monitor list enhancement
 
 
5. Grouping function enhancement in SPC
 
 
6. P chart enhancement
 
 
| Sunny Xiong
 
|-
 
| style="width: 50px;" | 07/01/2020
 
| style="width: 82px;" | Elaine Fonaro
 
| Technical Writer
 
| style="width: 85px;" | v1.2.28
 
| style="width: 523px;" |
 
1. Improved attribute group rules for creating monitors with attributes
 
 
2.SPC multi instances redesign
 
 
3.SPC System Parameter enhancement 4. Remove'''# of active thread '''from SPC System Parameter Page
 
 
| Sunny Xiong
 
|-
 
| style="width: 50px;" | 30/10/2020
 
| style="width: 82px;" | Marisol Vargas
 
| Technical Writer
 
| style="width: 85px;" | v1.2.28
 
| style="width: 523px;" | Peer review, structure revision, replaced Figures 5, 8 and 69
 
| Sunny Xiong
 
|}
 

Latest revision as of 18:13, 15 October 2024

42Q Home > Quality > Statistical Process Control

 

 

 

Quality
Statistical Process Control
Version MES 15.82
Revision O1
 

 

 
 

 

 

Contents

Introduction

 

Statistical Process Control (SPC) is an industry-standard methodology for measuring and controlling quality during the manufacturing process. It is a method used for monitoring, controlling, and, ideally, improving a process through statistical analysis.

Based on statistical theories, SPC (Statistical Process Control) is applied to manufacturing and production lines for the purpose of quality control. SPC enables users to continuously monitor, analyze, and control the production process in real-time to reduce possible waste and improve process capability. Key tools used in SPC include control charts, monitor maintenance, email notifications, system configuration, line stoppage, etc. On the client side, the SPC system includes three components: SPC Portlet, SPC TV Portlet, and SPC Dashboard Portlet. 

Using the SPC, the Company can Dramatically reduce variability and scrap, statistically improve productivity, reduce costs, uncover hidden process characteristics, instantly react to process changes, and make real-time decisions on the shop floor.

See below the main features of SPC:

  • Support BATCH units calculation for Yield and Pareto charts.
  • Display Affected Serials for all charts displayed.
  • Change chart background color for Out-of-Control conditions.
  • Email Notifications are sent to specific recipients for Out-of-Control conditions.
  • Ability to export DPMO reports.
  • Control on production process route (MFG hold) based on Pareto chart, P chart, NP chart, C chart, U chart, FPY chart, Xbar-R Chart, and I-MR Chart.
  • SPC Dashboard displays multiple monitors on TV in real time.
  • Support multiple data collection strategies: Automatic Collection data from MDS or MESWeb, Manual Collection data via SPC UI, and Automatic Collection data via SPC API.

 

  SPC also provides some charts that help to see graphically some statistics: 

  1. Attribute Control Charts – Process CONTROL (defects and defective units):
  • Monitors Grouping data by Piece: P and NP charts.
  • Monitors Grouping data by Defect Points: C and U charts.
  • Monitors by BATCH: Yield (pie) and Pareto charts.
  • Others: FPY and DPMO (DPMO, DPMO-P, DPMO-A, DPMO-T, DPMO-C) charts.

 

  1. Variables Control Charts – Process CAPABILITY control (attribute values)

If the combination of Monitor setup (Part Number + Process/Workstation) has attribute setup on Shop Floor Configuration (Attribute Maintenance) the attribute charts will be displayed on the Monitor Maintenance screen with X-Bar/R chart; I/MR chart; Cpk/Ppk.

To get more information, see the next topics of this document.  

 

Pre Configuration

Server Information

After SPC is deployed to the users' web server, users need to set up a server and configure the server information from the Server Information page.

To access the Server Information page in the MES Portal, navigate to: Administration > Server Information.

 

Create SPC Server 

To create an SPC server:

  1. Select Add from the Server Information page.
  2. Select SPC from the Program drop-down box. 
  3. Complete all the fields and select Add to save the configuration to the database. 

 

Figure 1: Add SPC Server

SPC AddSPCServer.png

 

Fields, as seen in the above screenshot, are explained in the following:

Name: The name of the SPC server.

Host: The SPC server IP address.

AppServer Port: The port that the SPC server deploys within the Tomcat server.

Context Path: The patch that the SPC server deployed on the Tomcat server. After the system is refactored, the system should have only one program that supports all sites/plants so the context path of server information for each site/plant should be /SPC-server.

Token: Safe Palindrome authentication to call the API. This is used to connect to the services for collecting data via SPC API.

Key: Safe Palindrome authentication to call the API. This is used to connect to the services for collecting data via SPC API.

Status: After you have completed all the fields above, select a status from this drop-down box, and click the check button to verify that the SPC server connection is working.

Note: This configuration can be Edited and or Deleted at any time.

 

 

 

SPC 

Monitor Group Maintenance

MES 15 Quality SPC uses the Monitor Group to maintain the SPC monitors that collect data from different sources. However, MES 15 Quality SPC does not actually collect data from SPI, it collects data from the SFDC archive as an associated database schema and support is not fully ready yet. The Dot Line Source was added in Monitor Group Maintenance to support the Dot Line chart, and the difference between the Dot Line chart and other charts is that the user transmits the data to the SPC through an API, and this data has been calculated, and the SPC directly uses the data for display.

 

 


View Monitor Group

To view existing monitor groups:

Navigate to: Quality > SPC

Once an SPC engine has been selected, the existing monitor groups that were created under the selected SPC engine will be displayed on the Monitor Group List page. 

 

Figure 2: Monitor Group List

SPC MonitorGroupListp.png


Create Monitor Group

Every monitor is created under a monitor group. So before creating a monitor, a monitor group must be created first. To create a monitor group:

From the SPC Monitor Group List page, select the RTENOTITLE button in the toolbar. SPC opens the Add Monitor Group page.

  1. Enter the monitor group name in the Name field.
  2. Select MDS, SPI, or DotLine Source from the Data Source Type drop-down box.
  3. If you need to send an MFG Hold to stop the production line, you can enable the Send MFG Hold request to the checkbox.
  4. Enter a Shop Floor ID,  and Description

 

Figure 3: New Monitor Group Page-MDS

SPC NewMonitorGroupPage-MDS.png

 

Note: The SPC program is deployed on the Amazon cloud server (in the USA). Users scan Serial Numbers on their local PC. So there will be a time zone difference between the SPC server and MDS if they are not in the same time zone.

SPC uses the value of this field to calculate the timezone of local MDS, compares it with the Amazon cloud server time zone, calculates the time offset, and determines the right time for the SPC monitor to retrieve data (create time + time offset) so that the scanned SNs data can display on monitor charts. 

The time zone is defined in the Plant Maintenance module by the administrator.

 

Figure 4: New Monitor Group Page - SPI

SPC NewMonitorGroupPAge-SPI.png

 

 

Figure 5: New Monitor Group Page - DotLine Source

SPC NewMonitorGroupPage-DotLineSource.png

Note: Since some data is manually collected by users, and this kind of data could not be extracted from 42Q, this data has been calculated, and an API was provided to collect the data and present it to users in the Dot Line Chart.

See below some rules to get the DotLine Chart:  

  1. First users need to create a new monitor with the below info specified:

 Specify which process parts will be used for this monitor to collect data.

 

  1.  Select Chart Type: Dot Line.

 

When the Dot Line Chart is selected,  the Application & Data Column is enabled to let users select which Application & Data Column will be used to display this chart.

  • Group By: Disabled.
  • Interval: Disabled.
  • Rules & Actions: Enable.

 

  1. Select GO on the new monitor from the Monitor Group List.

 

Figure 6: Go to New Monitor Group List

SPC GotoNEwMonitorGroupList.png

  1. Select NEW
  2. External Program will periodically pick data from Source Record by a certain frequency, and put it into SPC by publishing it;

 

  API interface

  1. SPC TV will select Monitor to display. 
  2. Draw Chart: just like the current u/p chart done in SPC.

X-axis: Time collected (Import Datetime), Format: MMDDmm

Y-axis: Data, UCL (Upper Control Limit), LCL( Lower Control Limit), Target

 

Figure 7: New Monitor DotLine Chart Available Charts Tab

SPC AvailableChartsTab.png

 

Select Data in the Drop Down List, and select both: Data1 and Data2 at the same time.

Note: Data1 or Data2 can be understood as a group of data. Users can choose to display the two groups of data together in the dot line chart, or just display one group of data.

And finally, users can select the following actions:

  • Send an alert email: This action sends an alert email to a specific person. Users can specify who would receive these alert emails in the Email Maintenance module. 
  • Change the background color to red: If the exception was triggered, the background of an associated data record in this monitor will turn red.

 

Figure 8: New Monitor DotLine Chart Actions Tab

SPC ActionsTab.png

Edit Monitor Group

To edit a monitor group:

  1. From the Monitor Group List page, check the box of a monitor group that users need to edit, and select Edit. The Edit Monitor Group page will display.
  2. Edit any field as needed, and select Save to keep the change, or Cancel to abort.

Figure 9: Edit Monitor Group Fields

SPC EditMonitorGroupFields .png

Filter Monitor Group

Users can easily find the desired monitor group in the Monitor Group List by adding a filter to the SPC Monitor Group List page. A monitor group can be filtered under three conditions. They are,

  1. Group Name
  2. Data Source Type
  3. Shop Floor ID

Figure 10: Filter Monitor Group

SPC FilterMonitorGroup.png


Delete Monitor Group

To delete a monitor group:

  1. From the Monitor Group List page, check the box of the monitor group to be deleted, and click  Del.

 

Figure 11: Delete Monitor Group

SPC deletemonitorgrouplist.png

Note: It is not allowed to delete the monitor group which contains one or more SPC Monitor.

Monitor Maintenance

SPC portlet provides users with plenty of parameters to maintain SPC monitors. An SPC monitor is a platform for the setup of such processes as object monitoring, data collection strategy, rules, control charts, and actions. With the monitor maintenance function, you can create a new monitor, edit the existing monitor, disable or enable the monitor, show monitor data or control charts, lock the monitor, and so on. So monitoring maintenance is a key function of SPC.

 

Preparation Work: Associate Part Number With a Route

MES SPC retrieves data from MDS via database view. To make the part number data configured in MDS to be displayed on the SPC monitor creation page, the part number must be manually assigned to a route.

 

Create Part Number

To create a part number:

  1. Navigate to: Shop Floor Control > Configuration > Shop Floor Configuration, and select the Part Number module.
  2. From the Part Number List page, select Add Part Number to proceed.
  3. In the Part Number Form float window, input some parameters to create the part number, and click the Save button.

 

Figure 11: Part Number Form

SPC PartNumberForm.png

 


Associate part number with a route

 

  1. From the Shop Floor Configuration portlet, select Product Route to proceed.
  2. In the List Route window, select the RTENOTITLE icon on the right of the menu bar.
  3. In the Part x Route Assignment List undefined window, select Add.
  4. In the Part x Route Assignment Form undefined float window, select a shop floor ID, input the part number, and select a route.
  5. Select Save to define the Part and Route assignment.

 For more information, please visit Part Number Maintenance SOP.

 

 

 



Create a New Monitor

SPC monitors should be created under an existing monitor group. 

Users are able to set up monitors one by one part number for different production lines for one location/process, so there are too many monitors to be maintained, causing a workload for them to maintain these monitors in 42Q SPC. From one plant estimate, there are about 30,000 monitors to be created to support 42Q SPCs rolling out to the whole plant. 

To solve this workload, users are able to do the following operations:

  • Create  Monitors in Batch
    • Support creates multi-part numbers/Family ID with one location/process/location family or multi-location/process/location family with one part numbers/Family id.
    • Allow users to export all the related attributes when creating a monitor.
    • If selected part numbers have attributes, the attribute selection box in the new monitor>Data Collection Strategy page will only allow the common attributes.
    • To create monitors in batch, users should fill in a batch ID. This batch ID will help users to do the operation of search or edit monitors.
  • Edit  Monitors in Batch
  • Delete  Monitors in Batch

 

  1.  From the Monitor Group List page, select the new server icon icon for a monitor group.

 

Figure 13: Monitor Group List Page: Go

SPC MonitorGroupListGop.png

 

  1. From the Function List page, select the Monitor Maintenance Icon

 

Figure 14: Monitor Group List

SPC MonitorGroupFunctionList.png

 

Monitor Maintenance SPC MonitorMaintenanceIcon.png

The user now enters the New Monitor form. This page provides all parameters to set up a customized single monitor or monitors in batch in SPC.

  1. On the Monitor List page, select the new monitor icon icon.

The user needs to fill in the necessary information in the available tabs to create monitors. See step by step in the next topic.


Monitor

The first section is the Monitor.

 

Figure 15: Monitor Section

SPC MonitorSection.png

 

  • Collect Data From: Enable SPC to collect data from Now or from a past date. 

Note: Historical data that contains exceptions could stop the present production line. If a previous date is selected here and the option Send MFG Hold request to was checked when creating the server, then a user attempting to save the monitor at this point will be prompted by a warning that asks the user to confirm the decision to save.

  • Batch ID: The name of the monitor or batch of monitors. This field cannot be edited as it is automatically set after the Part Number, Family ID, and Location,  Process, and Location Family. If monitor data is automatically collected from MDS, the monitor name consists of two parts separated by a hyphen: The first part is Part Number / Family ID, and the second part is Location / Process / Location Family. If monitor data is collected manually via SPC UI, the monitor name will also contain the third part: the attribute name. 
  • Part Number: The part number to be monitored by SPC. The part number is created and configured in MDS before being created in the SPC monitor. The Part Number option is selected by default. Users must enter a specific part number or select one from the associated drop-down box. 

 

Lightbulb icon.pngTIP: When users enter four characters into the field, the portlet will automatically begin searching and listing any part numbers that match the input. To date, the Part Number, Family ID, Location, Process, and Location Family fields support this search-as-you-type feature. 

 

  • Family ID: The Family ID is to be monitored by SPC. Family ID is created and configured in MDS before being created in the SPC monitor. Users must select the Family ID option manually and either enter the family ID or select one from the drop-down box.
  • Location: The location is to be monitored by SPC. Location is created and configured in MDS before being created in the SPC monitor. The Location option is selected by default. Users must enter or choose a location from the associated drop-down box. 

Note: Attribute is associated with part number + location or part number + process.  If a  monitor is created with part number A + location B and part number A + process B, some attributes will be associated, then the user can create Continuous control charts. The associated attributes can be viewed in the Data Collection Strategy tab.

  • Process: The process to be monitored by SPC. The process is created and configured in MDS before being created in the SPC monitor. Users must select the Process option manually and then enter or choose a process from the drop-down box.

Note: If the "Route by Process" option is enabled in SFDC when a new monitor is being created, the user may select either Part Number and Location or Part Number and Process.  However, if the Mfg Hold submodule is to be used to perform a hold on a serial number for a certain part number, the respective monitor should be created by selecting Part Number and Process, not Part Number and Location.

  • Location Family: The location family is to be monitored by SPC. Location Family is created and configured in MDS before being created in the SPC monitor. Users must select the Location Family option manually, and then enter by choosing a location family from the drop-down box.

Note: Some plans have more part number records but don’t have a relation with the route. The system will create a monitor with Part Numbers that should be relative to shop orders. Part Number/Family ID needs to set up a relation with the shop order whose status is Release.

 

Data Collection Strategy

The second section is the Data collection strategy. According to the data chosen (Part Number and Location) at the Monitor tab, the user can create continuous control charts.

 

Figure 16: Data Collection Strategy

SPC DataCollectionStrategy .png

 

  • Automatic Collection from Unit: Allows SPC monitor to automatically collect data from MDS service. This option is selected by default.
  • Manual collection via SPC UI:  Allow end users to manualy collection continuous data vis SPC ui(Input feature in SPC).
  • Automatic Collection via SPC API: With this option the users can create a monitor with Automatic Collection Via SPC API type and clients (such as PWB), which can push the data to SPC via its monitor API as long as the characteristics in the parameters of the API endpoint exist and match this monitor, the continuous data control charts (such as X bar-R chart, I-MR chart, and CPK/PPK report) will plot.
  • Subgrouping Method: This field defines the rules of how data should be organized to form a series of points plotted on control charts. It consists of the following components: Unit Quantity, Time, Subgroup Size textbox (if Unit Quantity is selected), and Time Range drop-down box (if Time is selected).
  • Unit Quantity:  The data will be grouped by quantity. The quantity is defined in the Sample Size textbox. For example, if a data source contains 100 data items and the sample size value is 2, then this data source will be divided into 50 groups (100 / 2 = 50). This radio button is chosen by default. 
  • Time: The data will be grouped by time range. For example, if a sampling period is 60 minutes and the time range is 10 minutes, then this sample period will contain 6 groups of data (60 / 10 = 6). Users must manually select the By Time option.

 

The sampling rules are customized by the user. The sampling method is divided into by time period sampling and by quantity sampling. The time and quantity can be set in SPC (The default sampling is the first serial number). 

Note: If there is no data in this sampling range, no new points will be created in X bar - R chart).

Note 2: It is not allowed to update the Data Collection Strategy if the DotLine source type is selected because the Dot Line chart is not a control chart, so these rules cannot be applied to the Dot line chart. To achieve the feature of sending an alert email or changing the background color to red, a rule must be set.

 A new rule according to the characteristics of the Dot line chart was added: Consecutive points above or lower than UCL or LCL.

SPC supports Continuous data and Discrete data control charts in one monitor. Users can choose one of them or the two control charts.

 

Figure 17: Data Collection Strategy - Continuous Data

SPC DataCollectionStrategy ContinuousData.png

 

Figure 18: Data Collection Strategy for Discrete Control Charts - Discrete Data

SPC Data Collection Strategy Discrete Data.png

 

 

Sampling Method

The sampling method belongs only to continuous charts. This field defines the rules on how data should be organized to form a series of points plotted on control charts. It consists of the following components:

  • Full (Full Inspection). 
  • Every X Units: Users can input the numbers of units. For example, 5, means the system will select one unit from every 5 units.
  • Every X Time: Users can select the time from the drop-down list. Options: 10 minutes, 15 minutes, 20 minutes, 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours,8 hours, 12 hours, 24 hours.

The original system defaulted to a FULL inspection, without configuration. For every Unit and Every time sampling, the system defaults to extract the first serial number of this time period/quantity for statistics.

Now with Attribute Maintenance Configuration, it is possible to check whether the attribute is in the same group. 

The current SPC  has an attribute grouping control logic. Only the same type of attribute can be monitored in a monitor, otherwise, it will prompt a warning message. To turn the SPC attribute grouping logic consistent with the actual SFDC attribute grouping rules, new rules were created for the attributes. According to the Attribute Maintenance Configuration, it is possible to check whether the attribute is in the same group.

Note: Only the attributes in the same attribute group can be monitored together in one monitor.

 

 

Standard Control Chart

The following section is the Standard Control Chart, which contains two sub-sections: Interval and Rules.

 

Figure 19: Standard Control Chart

SPC StandardControlChart.png

 

Interval

This subsection defines the frequency at that SPC recalculates the center line value of a control chart. Here valid groups are used as the frequency unit. It is allowed to use a new monitor with different grouping methods:

 

Figure 20: Interval Section

SPC IntervalSection.png

  1. No grouping and without recalculating bar values
  2. Allow the user to set the number of groups, and calculate the new BAR value used for the next data analysis
  3. Allow user to set the number of groups, use the same BAR value used for the next data analysis

See below a sample of the chart:

 

Figure 21: Chart Sample for Valid Group

Chart Sample for Valid Group

 

 

Rules

This sub-section lists all seven rules which are considered to be out-of-control exceptions. Users can select one or more rules in this checkbox group.

 

Figure 22: Rules Section

SPC RulesSection.png

Consecutive Points above or lower than UCL or LCL option will be available if the selected data source is DotLine Source.

 

Figure 23: New Monitor DotLine Chart Standard Control Chart Tab

SPC StandardControlChartUCL LCL.png

 

 

Available charts

This tab displays all available control charts, DPMO, and Other Charts in the current context. The SPC Control Chart is generated based on the data source that is configured in the Monitor section so that different configurations in the Monitor section may have different available charts. Users can choose one or more control charts in this checkbox group.

 

Figure 24: Available Charts (non Continuous control charts)

SPC AvailableCharts.png


The textbox on the right of the chart name is used for defining the centerline value of the control chart. For example, if a user chooses the C Chart checkbox, the C-Bar textbox becomes available. Users can then manually enter a number in the textbox, which becomes the centerline value of the chart.

Figure 25: C-Chart Field

SPC C-Chart Field.png


Note: Be careful with the values entered in the textbox for control charts if the line stoppage function is enabled. If the Send MFG Hold Request to MDS checkbox was selected when creating an SPC server, SPC may stop the production line if a user defines unreasonable values for the control chart based on the rules selected.

For FPY Chart, selecting the Display checkbox enables SPC to display the FPY chart on the monitor. The Trigger checkbox enables an out-of-control warning.


Note: The Current SPC allows users to choose a specific version to display FPY charts.

 

C-Chart

C-chart is an attribute control chart used with data collected in subgroups that are the same size. 

It shows how the process, measured by the number of nonconformities per item or group of items, changes over time. Nonconformities are defects or occurrences found in the sampled subgroup.

 

Figure 26: C Chart

C Chart  

 

U-Chart

U-chart is an attribute control chart used with data collected in subgroups of varying sizes. U-charts show how the process, measured by the number of nonconformities per item or group of items, changes over time.


 

Figure 27: U Chart

U Chart

 

NP-Chart

NP-chart is an attribute control chart used with data collected in subgroups that are the same size. NP-charts show how the process, measured by the number of nonconforming items it produces, changes over time.

Figure 28: NP Chart

NP Chart

 

 

P-Chart

P-chart is an attribute control chart used with data collected in subgroups of varying sizes. Because the subgroup size can vary, it shows a proportion on nonconforming items rather than the actual count. P-charts show how the process changes over time.

 

Figure 29: P Chart

SPC PChart.png

 

FPY-Chart

FPY is a First Pass Yield: 

  • Capable of plotting the First Pass Yield of a product at a particular process step over a period of time or number of boards.
  • Capable of manual configuration the upper control limit and lower control limit.
  • Can displays the target (Goal) line.
  • Capable to use the 7 Rule alarms for triggering.
  • Capable to trigger the alarm when FPY falls below the Target Line.

 

Figure 30: FPY Chart

FPY Chart

 

 

DPMO

Figure 31: DPMO Chart Types

SPC DPMOChartTypes.png

 

  • DPMO Chart: This enables SPC to monitor a manufacturing line with a DPMO chart. Defect opportunity and UCL represent the two parameters used for defining DPMO charts.

Note: The other 4 charts are custom made by the company according to the specific defect code. For example:
 

  • DPMO-Placement Chart: Placement is a defect code name. The chart is only for this defect code. The other 3 charts are the same
  • DPMO-Termination Chart: Termination is a defect code type. The chart is only for this defect code
  • DPMO-Assembly Chart: Assembly is a defect code type. The chart is only for this defect code
  • DPMO-Component Chart: Component is a defect code type. The chart is only for this defect code

 

Other Charts

The Other Control Chart section, has the following components:

 

Figure 32: Other Chart

SPC OtherChart.png

 

Yield -Chart

Enables SPC to monitor the manufacturing line with the Yield chart. The limit is a parameter used for defining the Yield chart.This chart shows the Yield value for a selected or retrieved process, one at a time, and a list of the N last products passed on this process.

 

Figure 33: Yield Chart

Yield Chart

 

 

 

 

Pareto Chart

Enables SPC to monitor the manufacturing line with a Pareto chart. Users can define a Pareto chart exception rule by selecting the Create exception when checkbox and entering, for example, 3 Defect codes of the same type within 10 Minutes.

The Pareto chart indicates which problem to tackle first by showing the proportion of the total problem that each of the

smaller problems comprises. It is a type of chart that contains both bars and a line graph, where individual values

are represented in descending order by bars, and the cumulative total is represented by the line.

 

Figure 34: Pareto Chart

Pareto Chart

 

For continuous control charts, users have to select Manual Collection and Multiple Units, Single Characteristics at the (Data collection strategy ) tab, then go to Available Charts, will get to see these options.

 

Figure 35: Available Control Charts for Continuous Control Charts 

Figure 48- Available Control Charts for Continuous control charts1.png

XBar-Chart

X-bar and R (range) chart is a pair of control charts used with processes that have a subgroup size of two or more. 

The standard chart for variables data, X-bar, and R charts help determine if a process is stable and predictable. The X-bar chart shows how the mean or average changes over time and the R chart shows how the range of the subgroups changes over time.

 

Figure 36: XBar Chart

XBar Chart

 


R-Chart

The X-bar chart shows how the mean or average changes over time and the R chart shows how the range of the subgroups changes over time.

Note: LCL can’t be negative. Both S (Standard Deviation) and R (Range) can't be negative, due to their nature. All the points that the user scans are displayed on the chart and when expanding chart details, all the information in the chart page is collected such as SPC Collection time, Average, LCL, UCL, OCAP, attributes, etc. There are no negative numbers on the Y-axis.

 

Figure 37: R Chart

R Chart

 

  • I-MR Chart I-MR chart is a combination of two charts (Individual and Moving Range) is to track the process variability based on the samples taken from a process over the period of time. An Individual moving range (I-MR ) chart is used when data is continuous and not collected in subgroups.

 


CPK/PPK-Chart

Cpk is the potential of a process to meet a specification (short term) while Ppk is how the process actually did (long term).

The Method of Std Dev(within) in the cpk/ppk chart has three available options:

  • Pool standard deviation
  • R Bar
  • Average moving range.

The method used to Std Dev(within) depends on the subgroup size.

When subgroup size > 1, SPC estimates Std Dev(within) using one of the following two methods: Pooled standard deviation and an average of subgroup ranges (Rbar), SPC selects Pooled standard deviation method by default.

Whensubgroup size = 1, SPC estimates Std Dev(within) using the Average moving range method.

See below the description and samples of the main available charts at SPC:

CPK/PPK shows if the real process capability meets the specification

Definitions

  •  Cp= Process Capability. A simple and straightforward indicator of process capability.
  •  Cpk= Process Capability Index. Adjustment of Cp for the effect of non-centered distribution.
  •  Pp= Process Performance. A simple and straightforward indicator of process performance.
  •  Ppk= Process Performance Index. Adjustment of Pp for the effect of non-centered distribution.
  • Cpk is for the short term, and Ppk is for the long term.

 

Cp and Cpk

It is common to express process capability in terms of:

  • How well can we meet the customer’s specifications?
  • Voice of Customer / Voice of the process
  • It is a potential capability index - Cp is defined as:

             Cp = USL – LSL/6σst

The minimum acceptable value for Cp is normally considered to be 1

Cpk = Min (USL- x, x – LSL)/3σst

When there is no shift or drift, Cpk and Cp are equal. As the process drifts, Cpk gets smaller. 

 

Pp and Ppk Chart

Over time, the drift in the process will have the effect of ‘flattening out’ the distribution, and the standard deviation of the process will increase.  To reflect this effect properly, we define two long term capability indices, Pp and Ppk.

These indices have the same formulas as their short term counterparts, but use the long term standard deviation in their denominators, σlt

Pp = USL – LSL/ 6σlt               Ppk = Min (USL- x, x – LSL)/3σlt

 

Figure 38: CPK/PPK Chart

SPC CPKPPKchart.png


Actions  

The fifth section is the Actions. This section defines what actions should be taken after the out-of-control exception is triggered.

 

Figure 39: Actions

SPC Actions.png

 

  • Send alert e-mail: This action sends an alert email to a specific person. Users can specify who would receive these alert emails in the Email Maintenance module.
  • Change the background color to red: If the exception was triggered, the background of the associated data record in this monitor will turn red.
  • Send MFG hold request after n minutes: This action is an SPC line stopper function. To enable this action, the following options must first be enabled:
  1. Send MFG Hold request to MDS checkbox in Add/Edit Monitor group page.
  2. Pareto Chart checkBox in Other Control Charts section.
  3. Create an Exception when n1 defect code of the same type within n2 minutes checkbox in the Other Control Charts section.

 

If Send MFG hold request after n minutes checkbox is enabled and if n1 defect code of the same type is scanned via NetDC within n2 minutes, SPC will send an MFG hold request to SFDC / MDS after n minutes. If the input minutes is 0, SPC will send the MFG hold immediately.

Note: This checkbox is not selected by default. Line stopper in SPC supports hold by part number + Location/process based on monitor selection. 

 

Lastly, remember to click save button to save all the configurations before you leave the page, or click cancel.button button if you want to give up the configuration and return to the Monitor List page.

 

 


Search Monitor

The Search Monitor portlet makes it very convenient to find a specific monitor from the monitor's list. You can find this function in the toolbar on the Monitor List page.

Figure 40: Search Monitor

SPC searchmonitor.png


Users can search monitor by' Monitor Name, Location, Process, Location By Family, Part Number Family ID, Batch ID, and Monitor' Status. 

Once search criteria have been selected and entered, select Search to execute the search action. 

 

Hide Inactive Monitors

It allows the user to filter out those monitors that have no new data coming in during the past settable hours. The user can define the settable hours in the SPC System Parameter Maintenance module, and view active monitors on the Monitor List page.

It can turn off the filtering inactive monitors function. This option is at the bottom of the screen.

 

 

View Active Monitors by Default Hours

In the Monitor List page, the checkbox Hide monitors with no data in chart in the past(hours) are selected by default along with a textbox displaying the hours defined in the SPC System Parameter Maintenance module. The SPC system filters out those inactive monitors that meet the condition.

Figure 41: Hide monitors with no data 

SPC hidemnitorswithnodata.png

Note: Users can Edit Settable Hours and also Disable Hide Inactive Monitors Function. 

  • Edit the hour’s textbox value and select Input to view corresponding monitors. The value allowed in this textbox is a positive integer between 1 to 168. Modification of the value here does not affect the value defined in the SPC System Parameter Maintenance module. 
  • Unchecking theHide monitors with no data in the chart in the past(hours) box deactivates the monitor filtering function so that the SPC system shows all existing monitors. 

Edit Monitor  (Edit Monitor in Batch)

SPC allows users to modify the parameters of an existing monitor according to their needs. Users can modify sections including Interval, Rules, Available charts, Other control charts, and Actions. To edit monitors, they must be stopped.

  1. Select a monitor in the same batch from the monitor list on the ‘Monitor List’ page, then hit the Edit icon in the toolbar.

Figure 42: Monitor List - Edit a Single Monitor

SPC editasinglemonitor.png

  1. Modify the preferred available information. 

Note that the Monitor tab is not allowed to be modified. Update the other tabs information accordingly.

Figure 43: Edit Monitor Page

SPC EditMonitorPage.png

Data Collection Strategy can also be edited.

Figure 44: Edit Monitor Page - Data Collection Strategy

SPC aDataCollectionStrategy.png

  1. Select Save to save all modifications before leaving the page. 

Note: If the Data Collection Strategy selected is Manual Collection via SPC UI, the user can also modify the Attributes values.

 

 

Edit Monitor (Edit Monitor in Batch)

In the main menu, the user must choose Batch ID from the search engine and select the monitors in the batch to edit, and then click the Edit icon in the toolbar.

Figure 42: Monitor List - Edit Monitors in Batch

SPC editmonitorsinbatch.png

Figure 43: Edit Monitor Page

SPC editmonitorpage.png

  1.  Modify the preferred available information. Note that the Monitor tab is not allowed to be modified. Update the other tabs information accordingly. 

Note: If the Data Collection Strategy selected is Manual Collection via SPC UI, the user can also modify the Attributes values. 

 


Delete Monitor / Delete Monitor in Batch

If users no longer need a monitor or monitor in batch and want to remove it, the monitor can be deleted. 

Note that once a monitor is deleted from SPC, it cannot be restored, and this is permanent. 

To delete a monitor:

  1. Check the box of the monitor to be deleted, and select Disable to disable the monitor first.
  2. Once the monitor is disabled, locate the monitor in the disabled monitor list and check the box of the monitor to select it.
  3.  Click the DEL icon in the toolbar.

Figure 47: Function List - Delete

SPC functionlistdelete.png

4. Choose Yes in the pop-up window.

To delete a monitor in batch:

  1. Search for the Batch ID and select the monitors in the batch to be deleted.
  2. Check the box of the monitors to be deleted and select Disable to disable the monitors first.
  3. Once the monitors are disabled, check the box of the monitors to select them.
  4. Click the DEL icon in the toolbar.
  5. Then choose Yes in the pop-up window

 


Disable, Enable, Delete Monitor

SPC supports automatic start monitors to simplify the application use process, this will greatly reduce maintenance costs

Engineers only need to create monitors when they have a new product or disable/delete monitors after the product has been EOL. Even keeping a large number of Enabled monitors will not affect SPC performance.

 

Figure 48: Scenarios

Monitor m

 

 

Enable monitor 

  To enable a disabled monitor 

  1. Find the disabled monitor in the list and check the box for that monitor. 
  2. Click the Enable icon in the toolbar. 

Figure 49: Function List - Enable

SPC funtionlistenable.png

Users can search enabled monitors using the search function by selecting Enabled from the monitor status drop-down list and clicking the Search icon.

 

 

Disable Monitor  

After a new monitor is created, its status is Started by default. The monitor's data is automatically collected from MDS. 

If a user does not need a monitor to operate, the user can disable the monitor. 

  1. To disable a monitor, check the box of the monitor. 
  2. Select the Disable icon to disable the monitor.

Figure 50: Function List - Disable

SPC disablemonitor.png

Users can search for disabled monitors using the search function by selecting Disabled from the monitor status drop-down box and clicking theSearch icon.   

 


View Monitor History 

 To view the modification history of a monitor:

  1. Go to the Monitor List page, select a monitor, and click the REV icon.

Figure 51: Monitor List - Rev Icon

SPC monitorlistrevicon.png

Manually Input Data to Monitor 

To date, the SPC monitor supports three data collection strategies: Automic Collection From Unit Attributes, Manual Collection via SPC UI, and Automic Collection via SPC API, which can be configured in the Data Collection Strategy section. If ‘manual collection via SPC UI’ is selected as a data collection strategy, data must be manually entered after the monitor is created.   

 

 


Input Data for Only One Monitor 

To enter data for one monitor: From the Monitor List screen, select the monitor that needs to manually input data (the ‘Collection Type’ value of this monitor is ‘Manual’), and then click the Input icon.

Figure 52: Monitor List - Input

SPC monitorlistInput.png

In the Collect New Data page, input attributes data to correspondent fields. 

Figure 53: Input - Collect New Data 

SPC CollectNewData.png

 

 

 


Input Data for Multiple Monitors At Once

  Users can select and input data to multiple monitors at once, as long as all of the selected monitors' Collection Type is Manual.

Figure 54: Monitor List - Collection Type Column

SPC collectiontype.png

Note: If users have selected monitors that contain at least one monitor whose Data Collection Type is not Manual, and click Input, users will be prompted by an alert window saying 'You have selected at least one monitor that is not for manual data collecting. Please check and try again.' Close the alert window by clicking Ok

 

Input Attributes for the Current Monitor 

On the Collect New Data page, users can enter attributes for multiple monitors at once. The Monitor drop-down list will display the currently selected monitor to input data. Users can view the Line, Monitor Name, and Location of the current monitor in the top left corner. Note that the allowed input of attributes is number only.

Note 1: If users have input values in at least one of the fields and select Reset, an alert window will display with the warning message, 'You are about to reset all values. This action will delete all values of the current monitor. Are you sure you want to proceed?' Selecting Yes resets all entries for the current monitor to the default value. 


Note 2: If users have input values set to at least one of the fields, and select another monitor from the Monitor drop-down list, an alert window will display with the warning message, 'The data for the current monitor has not been saved yet. Are you sure you want to go to another monitor?' Selecting Yes will redirect the user to another monitor without the current monitor's data stored in the SPC system. 


Note 3: If users have input values to at least one of the fields and select the New Record button, an alert window displays with a warning message, 'You are about to cancel the attribute data entering. The current monitor will have no attributes recorded. Are you sure you want to proceed?' Selecting Yes will move a user to the Monitor List page without the current monitor's data stored in the SPC system. 

 

Save the current monitor's attributes data 

In the Collect New Data page, if a user has finished inputting data to the current monitor, and selects Save, all the current monitor fields turn grey except the Monitor drop-down list and the user cannot edit any data. The current monitor name in the Monitor drop-down box changes to 'monitor_name (Saved)' where monitor_name is the name of the current monitor. Now the user can switch to another monitor to input attribute data to that monitor. 

 

Switch to Another Monitor 

To switch to another monitor to input attributes, click the Monitor drop-down box and select another monitor from the list. 

Automatic Collection via SPC API 

TheAutomatic Collection via SPC API method allows the users to create a monitor with Automatic Collection Via SPC API type, the clients (such as PWB) or other third-party applications to push the data to SPC via its monitor API as long as the characteristics in the parameters of the API endpoint exist and match this monitor, the continuous data control charts (such as X bar-R chart, I-MR chart, and CPK/PPK report) will plot with SPC.  

Scenario

One plant needs to measure the thickness of its products multiple times during a process that can take days. They measure the thickness every 1/2 to 1 hour. They need to collect the thickness using Production Workbench as this is the interface the Operators use for the entire manufacturing process. Every thickness measurement collected via Production Workbench should be displayed on the SPC chart in near real time not only when the unit (non-serialized batch) moves from the location via terminator command.

SPC shall display all records collected via PWB attributes in “near real time”. This shall occur upon submission without regard to if we are in the middle of the process or at the end of the process moving to the next location.

The customer does not desire to use another user interface (SPC, Measurement, custom, etc) to collect the data. The operators will be working in PWB only at the terminal. (Thin terminals are to be used.)   The following will take the Production Workbench sending attribute values to SPC via SPC API as an example to explain the work process step by step.

 


Work process Step by step

To transmit data through the API, the SPC Token, Key, the Generic attribute needs to be set. 

  • Step 1: Define the SPC Server information at the Server information.

Navigate to: Administration > Server Information; add one SPC server information.

Note: Please select the SPC for the Program field.

  • Step 2: Define the generic attribute form at the Generic Attribute Maintenance(MDS) module that allows the production workbench to call the SPC API to send attribute data to SPC.

 Navigate to: Administration > Generic Attribute Maintenance(MDS); add one Generic Attribute information.   

Note: Please select spc_service_host for the Attribute Name field and Project for the Table field. And the Value is the SPC Host: SPC AppServer Port (The SPC Server defined at the server information).

  • Step 3: Create a Monitor, select theAutomatic Collection via SPC API at the Data Collection Strategy tab.

And add the attributes to the Characteristics list.

Note: The Characteristics must be the same as the attributes used/scanned at Production Workbench.


Figure 55:  Create a Monitor Automatic Collection via SPC API

SPC AutomaticCollectionviaSPCAPI.png  

 

  • Step 4: Input/Scan the Serial number at the Production Workbench application.

To transmit the values of the attributes to SPC via the SPC API, the users select the command. e.g. Record Monitored Measurement.

After inputting the command, some fields will show:

SPC Monitor Name?: Input the SPC monitor name. The Monitor Name must be the monitor that is created in step 3.

Attribute Name?: Input the Attribute name. The Attribute Name must be the Characteristics that are defined in the Data Collection Strategy tab.

Attribute Value?: Input the attribute value. The value will be transmitted to SPC via SPC API even if the user doesn’t input the terminator/end command. The user can view the chat on the monitor in real-time. e.g. The input value 99 will show on the monitor chart.

 

Figure 56: Production Workbench

  Monitor List - New Record

 

  • Step 5: The users can view the charts (attribute values) at the monitor charts.

Select the monitor, then select the Chart to view the chart.

 

Figure 57: Monitor Chart menu.

  Monitor List - New Record

 

Figure 58: Attribute value on the Chart

  Monitor List - New Record

 

 


View Control Chart, Data & Write OCAP

Control Chart is a very important tool for SPC to monitor the manufacturing line. Through the analysis of control charts, users can learn whether a manufacturing line or process is under control and determine the reasons for an out-of-control exception, so that they can take appropriate measures. To date, our SPC system supports 6 control charts: C chart, U chart, P chart, NP chart, X Bar-R chart, I-MR chart, and also supports 5 other charts: DPMO chart, FPY chart, Yield chart, Pareto chart, and Cpk / Ppk chart.

The SPC development team applies Ext JS technology, other than the old Jfreechart technology to all of the 11 charts. The Ext JS technology enables SPC to represent more interactions with the user from the UI perspective. For instance, a user can view more information about a chart point by hovering their cursor over the point. Also, users can view both SPC charts and data on the same page without having to open them on different pages.

 

 

 

View Control Chart

Here take the C chart as an example to demonstrate how to view the control chart with the Ext JS technology enhancement. The operation of other control charts is similar to the C chart below.

  1. To SPC view the control chart, from the Monitor List page, select a monitor and click the chart button icon in the toolbar. This displays the chart page.

Figure 59: Function List - Chart

SPC functionlistchart.png
Note: On the top of the page users will see a few brief pieces of information on the control chart, such as monitor name, part number, and location. The family ID can also be displayed here if the Display Family ID is checked in the SPC Portal System Parameter module.

To view any chart, users have to choose it from the available chart listed on the drop-down list at the top of the page, and then select a revision, click Retrieve and SPC will generate the chart according to the parameters used.

 

Figure 60: Chart Retrieve

SPC ChartRetrieve.png


Lightbulb icon.pngTips:

  1. On the Chart, blue points are normal points, red points are exception points, green points are exception points that have been written OCAP.
  2. If you move the cursor over a point in the chart, a pop-up window will be prompted showing more information about the selected point, including SPC Collection Time, Inspected, Defects and Cause. Note that control charts vary in more information about a selected point.
  3. If you click a point on the chart, the corresponding data line in the data list will be highlighted; if you select a data line from a data list, the corresponding point on the chart will be highlighted as well.
  4. The red background of a data line means that this data item has violated the rules you defined in the Rules section, and the OCAP of this data record has not been processed yet; the green background of a data line indicates that OCAP of this data record has been processed.
  5. This data list table structure consists of 9 columns: SPC Collection Time, Inspected, Defects, UCL, LCL, OCAP, OCAP History, Cause and Affected S/Ns.

 

Figure 61: C-Chart Information Points

SPC ChartInformationPoints.png

 

 

Write OCAP

To write OCAP, means to write something about the fix to the exception. To do this:

  1. Select the ocap button icon, then input the description of this OCAP in the pop-up OCAP windows.
  2. Select save button to save the change to SPC.

 

Figure 62: OCAP Window

SPC OCAPWindow.png


If there are more than one unprocessed OCAPs after entering a description of the current OCAP, enable the Apply to previous OCAPs checkbox to apply the change to all the unprocessed OCAPs.

After the OCAP is processed, the background of the associated data record will turn green.

View OCAP History

Select OCAP history button to view the OCAP history of a data record in the pop-up OCAP history window.

 

Figure 63: OCAP History

SPC OCAPHistory.png

 

View Cause

Select cause button to view the rules that the current point has violated.

 

Figure 64: Cause

SPC Cause.png

 

 

View Affected S/Ns

Users can view the affected serial numbers and export them to an CSV file.

  1. Select affected S/Ns button to activate a pop-up window that displays the affected S/Ns list.

 

Figure 65: Affected Serial Numbers

SPC AffectedSN.png

 

  1. To export the affected S/Ns to an CSV file, click the export affected S/Ns icon icon at the bottom of the Affected S/Ns window.
  2. Select the first option to export only one monitor, else, select the second option to export all monitors.
  3. Select the Export button.

 

Figure 66: Selecting The Monitors To Export

SPC Selecting The Monitors To Export.png

 

  1. Select Yes in the pop-up window to confirm the action.

 

Figure 67: Confirm Export Alert

 SPC Confirm Export Alert.png

 

  1. Choose whether to open the XLS file or save it to the hard drive.

 

There is a reference link at the Defects, that will show the Defect Code.

 

 

Figure 68: Defect Message 

SPC DefectMessage.png  

 

 

 

 

 

View And Edit Data

Users can view detailed data of a monitor. To do this:

  1. Select a monitor and click the data icon  icon in the toolbar in the Monitor List page. 

On the ‘Data List’ page, set the time frame for the search by selecting the beginning date and ending date in the toolbar.

Select a status from the data status drop-down list and click the search icon  icon to view the matching data.

 

Figure 69: Data List - Automatically Collected Records

SPC automaticallycollectedrecords.png

Note: The user can click the Export icon to export the records to an CSV file.

 

The data can also be Enabled, Disabled, and Edited.

Enabling Data restores a data record from disabled status. To do this:

  1. Select the data record from the disabled data list, then click the enable data icon  in the toolbar. 

A data record in the data list stands for a single point in a control chart. Disabling a data record will remove the associated point from the control chart. To disable a data item:

  1. Check the box of a data record, then click the disable data icon in the toolbar. 


Users can search disabled data records by setting the time frame for the data record by selecting the beginning date and ending date, and selecting Disabled from the data status drop-down box. Then click the Search icon to execute the search action. 

Edit Data function is limited to the monitor whose data is manually collected by SPC UI. To edit data record:

  1. From the Monitor List page, select a monitor whose Collection Type value is Manual, and click the data icon icon.
  2. In the Data List page which lists the enabled data, go to the last page of the list, select the last line and click edit icon in the toolbar (only the last data record is allowed to be modified). The user will be redirected to the Edit Data page where any data fields may be edited.
  3. Select Save to complete the changes.

 

Figure 70: Data List - Edit

Edit Data Page

 

 

 


Maintain Lock

SPC offers a full set of functions to manage MFG hold. When creating a new monitor, users can define the minutes of delay before MFG hold was sent. Users may view lock records and unlock existing locks as well.

 

 

View Lock

  1. To view lock, from the Monitor List, select a monitor and click the lock button icon in the toolbar. The Lock List page displays.

 

Figure 71: Monitor List - Lock

SPC lock.png
The Pareto Chart, C chart, U chart, NP chart, P chart, FPY chart, Xbar-R chart, and I-MR chart can send an MFG hold request to MDS. Users can view locks in different statuses as long as different values are selected in the lock status drop-down list. For example, if a user wants to find locked locks, select LOCKED from the lock status drop-down list, and click the search icon icon in the toolbar.

Figure 72: Lock Search Drop-down

SPC LockSearch.png

 

 

Users can search lock data by control chart type and lock status.
There are four statuses for locks: WAITING, LOCKED, UNLOCKED, andCANCELED. The CANCELED

  • WAITING: the lock that is waiting to be sent to MDS. When an out-of-control case is detected, SPC will wait some minutes before sending the MFG hold to MDS until it reaches the number of minutes defined by Send MFG hold request after * minutes field in the Actions section. During this period, the lock is in WAITING status.
  • LOCKED: MFG hold has been sent, associated location or process has been locked and OCAP has not been processed.
  • UNLOCKED: User input OCAPs to unhold the associated location or process, then the locked lock becomes UNLOCKED.
  • CANCELED: This lock status is a new status as of SPC 3.2. For a better understanding of this status, consider the following scenario: A SPC monitor was created for Pareto Chart that 3 defect codes of the same type within 10 minutes will trigger the exception, and MFG hold will be sent to MDS 5 minutes later. A few minutes later, a first MFG hold will be triggered, if a second MFG hold is triggered during the first hold’s delayed sending time in the new lock mechanism, the second hold will not be sent to MDS, and the status of the second MFG hold is CANCELED.

To unlock a lock:

  1. Select the lock and click the unlock icon icon in the toolbar.

 

Figure 73: Unlock Icon

OCAP - Unlock

 

Users can export the lock list to an CSV file:

  1. On the Lock List page, click the export icon icon at the bottom of the list.
  2. Select Yes in the pop-up window to confirm the action.

 


 


View Monitor Details

To learn detailed information about a monitor:

  1. Go to the Monitor List page, select a monitor, and click the more icon text link at the right side of the line.

 

Figure 74: Function List - More

SPC More.png

 

  1. In the pop-up Monitor, the details window provides multiple items of information including monitor name, data collection strategy, interval, rules, selected charts, and actions.

 

 


Email Maintenance SPC EmailMaintenanceIcon.png

Email notification is an important way for SPC to monitor the manufacturing line in real-time. When exceptions are found, SPC will send an email alert to the associated employee or supervisor so that they can analyze the exception according to the alert email and other SPC tools, and take appropriate measures, such as checking the production line, writing OCAPs, and stopping the line.

To access the Email Maintenance Page:

  1. Go to the Function List page and click the email maintenance icon icon to enter the email maintenance module.

From the Email Maintenance page, the users are able to access the following functionalities:

  • Email Group
  • Add Monitor Receive Email Rules
  • Edit Monitor Receive Email Rules
  • Enable
  • Disable
  • Search

 

Figure 75: Email Maintenance

SPC EmailMaintenanceMain.png

 

 

Email Group

The Email Group Maintenance submodule allows users to add, edit, delete, and search email groups and also,  associate emails to groups.

 

Figure 76: Email Group Maintenance

SPC EmailGroupMaintenance.png
 

 

 

Add Email Group

The first thing that the user needs to do is create a User Group with a name and description to create the Receive Emails Rules.

  1. Select on the New button to create an email group.

Figure 77: Email Group Maintenance - New

SPC emailgroupmaintenance .png

 

  1. Enter the Name and Description (mandatory fields) for the new email group; Select the save button.png to keep the configuration to SPC. 

Edit Email Group

To update the email group information:

  1. Select the Edit button to update the email group information.

 

Figure 78: Email Group Maintenance - Edit

SPC EmailGroupMaintenanceEdit.png  

Update Name or Description fields as needed.  Select the save button.png to keep the updates.

 

Associate Email

After creating an email group, the user is able to associate as many as emails is needed.

  1. To associate emails to the group, select a group in the list and click on Associate Email.

 

Figure 79: Email Group Maintenance - Associate Email

SPC AssociateEmail.png

 

The email list page will display, and the user can add, edit, or delete emails.

 

Add, Edit, and Delete Emails to Group

To add an email to the group:

  1. From the Email List page, click on the New button:

 

Figure 80: Add New Email to Group

SPC AddNewEmailtoGroup.png

 

  1. Insert the email in the Email field (mandatory) and select Save to keep the email in the group. In the same way, users can Edit and Delete by clicking the icons in the toolbar. 

 

Search Email Group

Users can search existing email groups by keyword: 

  1. Select the kind of keyword in the keyword category drop-down list (Name or Description). 
  2. Enter the keyword in the keyword textbox, and click the Search icon to search. 

 

Figure 81: Email Group Maintenance - Search Email

SPC SearchEmail.png

 

Users can also Edit and delete email groups. The Reference by Email Rule will show a Tip.

 

Figure 82: Email Group Maintenance - Tip

SPC Tip.png


 

New Email Rule

 

This functionality allows users to create email rules as needed.

To create a new email Rule, in the Email Maintenance Page, select the New button.

 

Figure 83: Email Maintenance - New Email Rule

SPC NewEmailRule.png

From this page, the user needs to enter the Name, Description, and associate an Email Group (mandatory fields), created in the Email Group functionality.

After this, the rules can be created as needed by: Shop Floor ID, Part Number, Family ID, Process, Location, Family ID, and Monitor Group

To Edit and or Delete the Email Rule, the user must use the corresponding icons on the toolbar.

This functionality allows users to edit the email rules as needed, when Delete is selected Select Yes in the pop-up window to confirm the action.

 

 

 

Enable / Delete Email Rule

To Enable or Disable an Email Rule record from their status:

  1. Select the email rule record from the enabled/disabled data list, then click the enable icon in the toolbar.

 

Figure 84: Enable / Disable Email Rule

SPC enableanddiableemailrule.png

When Delete is selected, click Yes in the pop-up confirms window. 

Alert Email

Alert emails from SPC will contain titles like Alert message from SPC application that will contain seven information fields: Line, Monitor, Part Number, Location, Chart, Date, and Description
When the users click the link in the mail, the system will access the charts which were generated by the alert email.

 

Figure 85: View the Chart from the Email Link

Alert email example

 


Lock Maintenance SPC LockMaintensanceIcon.png

This functionality allows the user to unlock hold, search lock records by time range, and export hold records on one page.

 


Maintain SPC Lock Maintenance 

Users may access SPC Lock Maintenance by selecting the lock button icon on the Function List page. Users may view lock records and unlock existing locks as well. 

 

View Lock 

1. To view the lock, from the Monitor List, select a monitor and click the lock icon in the toolbar.

Users will be able to perform searches by Monitor, Chart, Status, and also Export.

Figure 86: Lock Maintenance - Lock List

SPC locklist.png

The lock mechanism has been modified so only the Pareto chart can send an MFG hold request to MDS. Users can view locks in different statuses if different values are selected in the lock status drop-down list. For example, if a user wants to find locked locks, select LOCKED from the lock status drop-down list, and click the Search icon in the toolbar. 

 

  • WAITING: the lock waiting to be sent to MDS / SFDC. When the out-of-control case is detected, SPC will wait some minutes before sending the MFG hold to MDS until it reaches the number of minutes defined by Send MFG to hold requests after * minutes field in the Actions section. During this period, the lock is in WAITING status. 
  • LOCKED: MFG hold has been sent, the associated location or process has been locked and OCAP has not been processed. 
  • WAITING UNLOCKED: When users operate unlock in the lock page, first the "waiting for unlock" status, is followed by the "unlocked" status.
  • UNLOCKED: The user input OCAPs to the on-hold associated location or process, then the locked lock becomes UNLOCKED. 
  • CANCELED: This lock status is a new status as of SPC 3.2. For a better understanding of this status, consider the following scenario: A SPC monitor was created for the Pareto Chart that 3 defect codes of the same type within 10 minutes will trigger the exception, and an MFG hold will be sent to MDS 5 minutes later. A few minutes later, a first MFG hold will be triggered, if a second MFG hold is triggered during the first hold’s delayed sending time in the new lock mechanism, the second hold will not be sent to MDS, and the status of the second MFG hold is CANCELED.


Location Family Maintenance SPC LocationFamilyMaintenanceIcon.png

The location family is a collection of locations. One location family consists of one or more locations, which can be derived from different processes and departments. The authorized user can create, search, edit, disable, delete, and enable location family.

 

Create Location Family

To create a new location family:

  1. Select the location family icon icon on the Function List page.
  2.  On-Location Family List page, click new server icon button in the toolbar.
  3. Select Process, or Department.

 

Figure 88: Location Family List Page - New Icon

SPC Locationfamilylistpage.png

 

 

  1. Enter values in the Location textbox to filter locations. If a user changes the values of the Location textbox, its instant search function activates, and the SPC system automatically searches matching locations from the locations that belong to the selected department, displaying matching locations in the Location selection box.
  2. Select a location and click the right arrow icon button to add locations from the left panel to the right panel. More than one location can be selected at a time.

 

Figure 89: Add Location

SPC AddLocation.png

 

  1. Lastly, click the Save button to Save your data to SPC. 

 

 

 

Edit and Delete Location Family 

  To edit a location family:

  1. Select a location family from the list, then click the Edit icon in the toolbar. The Edit Location Family page will display. 

  

Figure 90: Location Family Edit 

SPC Locationfamilyedit.png

  1. In the Edit Location Family page, edit any field you want, and save the changes. 

  To delete a location family, the user has to Disable the location first.  

 

  1. Select the location family and click Disable.
  2. Search the disabled location family list for the disabled location family, select the location family, and click Delete.

 

Figure 91: Location Family List - Delete

SPC Locationfamilydelete.png

  1. Select Yes to confirm the action. 

 

Enable / Disable Location family 

  To enable a location family:

  1. Select a location family and click the Enable icon in the toolbar. 

   

Figure 92: Location Family List - Enable

SPC Locationfamilylistenable.png

  1. Choose Yes in the pop-up window. 

 

DeleteTo disable a location family:

Select a location family and click the Disable icon in the toolbar. 

 

Figure 93: Location Family List - Disable

SPC Locationfamilylistendisable.png

Choose Yes in the pop-up confirms window.   
 

Search Location Family 

  SPC enables users to search for location families by keyword and status. To search for a location family:

  1. Go to the Location Family List page
  2. Select a keyword category, and input a keyword in the text input box
  3. Select a status
  4. Select the Search icon

 

Figure 94: Search Location Family

SPC SearchLocationFamily.png


System Log Maintenance SPC SystemLogMaintenanceIcon.png

Some important system events, such as data modification and stopping a monitor, will be automatically added to SPC system log. System log plays an important role in system security. Users can analyze the system log and decide to take appropriate measures, like data recovery and file backup, to defend the system. In the SPC system, authorized users can search, view, and delete system logs.

 

Search and View System Log

On the Function List page, users can click the system log icon icon to navigate to the System Log page. On the System Log page, users can search the system log by time frame or by event owner:

 

Figure 95: System Log Page

SPC systemlogpage.png

 

  1. Input event owner in the Performed by textbox or choose a time frame and click the search icon icon in the toolbar.
  2. System log list table structure contains three columns - Date, Performed By, and Operation.
  3. Delete System Log

Every 24 hours, SPC automatically deletes system logs created 3 months before. Authorized users can delete logs manually via SPC UI. Users can delete logs individually or in batches. 


SPC System Parameter MaintenanceSPC SPCSystemParameterMaintenaceIcon.png

Authorized users are allowed to set general system parameters according to their local plants, manufacturing lines, or other special needs. This part of system parameters configuration affects the performance of the current SPC server, caution is necessary when defining the parameter values.

 

Users may access SPC System Parameters Maintenance by selecting the  icon on the Function List page.


On the SPC System Parameter page, eleven fields are displayed and the user can move their mouse over the more info icon icon to learn more information about the labels.

See below the fields description:

 

Figure 96: SPC System Parameter Page

SPC SPCSystemParameterPagew.png

An explanation of the fields from the above screenshot follows: 

  • Interval of collecting data (second): During real-time monitoring, each monitor will periodically collect data from SFDC archive database or other data source, the setting determines how often each monitor collects data.
  • Interval of deleting log (hour): There is one background job (thread) responsible to periodically delete the system log, this setting determines how often the background job deletes some system logs.
  • Time of log saved (month): System log will not be saved forever, a too old log will be deleted by background job, this setting determines how long the system log is saved in the database.
  • Interval between lock reviews (second): How often the background job review lock (or called MFG hold request to determine if one waiting lock should be sent to the MES.
  • Display family ID in chart: By selecting this checkbox, the Family ID will display on the SPC chart.
  • Start time of data collection (month): After one monitor is created, this monitor related data can be retrieved from a past time, this setting determines how old data can be when retrieved by monitor. The default value is 3 months. 
  • Hide monitors with no data in chart in the past (hours): It allows users to filter out those monitors that have no new data coming in during the past settable hours. Users can input a positive number between 1 to 168 in the textbox. The default value for this textbox is 24. To view the effect, you can check the Hide Inactive Monitors feature on the Monitor List page. 
  • Hide on TV and dashboard if monitors with no data in chart in the past (hours): The SPC will automatically disable those monitors that have no new data during the past settable hours. The hours quantity textbox next to it has a default value of 8 (hours). This textbox allows positive integers from 1 to 24. 

 Note: All the newly created monitors are enabled by default. Users can define this value, then the system will hide the monitors with no data to avoid there being too many monitors in the list. 

  • Enable Previous SPC Hold function: Previous Hold function will be invoked in the following scenario: after a part number was put on SPC Hold by SPC for the settable number of consecutive defect codes within a set time limit, will display ‘PREVIOUS SPC HOLD’ in NetDC rather than issuing an immediate SPC holds. 

Note: If a monitor is stopped, disabled, or deleted, the Previous Hold function of this monitor will be automatically turned off as well.  Users must enable the Send MFG to hold to  MDS checkbox in Add Server Information page first, before enabling the Enable Previous SPC Hold function checkbox.

  • Enable PCB function:  Enable PCB function as global parameters affect one site. Its default value is unselected. PCB plants need to click the checkbox to make PCB function take effect. The PCB checkbox affects monitor creation and data collection.

Enabling the PCB function will enable the following requests from PCB plants when creating an SPC monitor: the ability to see the PN without a route assigned, the ability to display attributes with not defined PN as well as count defect code B.

  • Email Title: To set the title of the alarm email.
  • Enable monitor name in email title: This checkbox will send an Alert message from SPC application with the monitor name to the user’s email address.
  • MESR URL Template: This field is to set a URL link to the MES Web. The URL template is plantcode-mesweb-med.42-q.com or plantcode-mesweb-med-uat.42-q.com. Hence, the original HTTP URL template is not suitable as a fixed URL link.

 

After all configurations are done, remember to click the  save button icon. If the save was successful, the user will see the message 'Configurations are successfully saved and will be immediately effective'. If there is a malfunction, users will see the error message 'Configurations are not saved, please try again or contact administrator.'