Difference between revisions of "How to manage Calibration in CMMS"

From 42Q
Jump to navigation Jump to search
 
(9 intermediate revisions by 2 users not shown)
Line 1: Line 1:
  
= Configure the Calibration Group =
 
  
#Go to: '''Shop Floor Control > Config > CMMS Admin > Group'''.
+
= Summary =
#Add a new Calibration Group or edit an existing Calibration Group.
 
#Select the Calibration Categories at the '''General''' tab as needed.
 
#Go to the Users tab and add Users one at a time.
 
  
'''Figure 1: Set Group Category'''
+
This doc will tell the users how to manage calibration in CMMS.
  
[[File:1 Group.png|800px|1 Group.png]]
+
= <span class="mw-headline" id="Prerequisites"><span class="mw-headline" id="Prerequisites"><span class="mw-headline" id="Prerequisites"><span class="mw-headline" id="Prerequisites"><span class="mw-headline" id="Prerequisites"><span class="mw-headline" id="Prerequisites">Prerequisites</span></span></span></span></span></span> =
  
'''Figure 2: Add Group’s Users'''
+
*'''Groups''' are defined ('''Shop Floor Control''' > '''Configuration''' > '''CMMS Admin''' > '''Group''')
 +
*'''Calibration Assignment/'''Calibration Notification&nbsp;Categories are selected for the Group ('''Shop Floor Control > Configuration > CMMS Asset > Group > Assign Group > Category'''. Can also be accomplished when Group is defined).
 +
*'''Asset''' is created ('''Shop Floor Control > Configuration > CMMS Asset > Asset''')
 +
        <div class="eJOY__extension_root_class" id="eJOY__extension_root" style="all: unset;">&nbsp;</div>
  
[[File:Add group user.png|800px|Add group user.png]]
+
= <span class="mw-headline" id="Configure_the_Calibration_Groups"><span class="mw-headline" id="Configure_the_Calibration_Groups"><span class="mw-headline" id="Configure_the_Calibration_Groups"><span class="mw-headline" id="Configure_the_Calibration_Groups"><span class="mw-headline" id="Configure_the_Calibration_Groups"><span class="mw-headline"><span class="mw-headline"><span class="mw-headline"><span class="mw-headline"><span class="mw-headline"><span class="mw-headline">Configure the Calibration Groups</span></span></span></span></span></span></span></span></span></span></span> =
  
&nbsp;
+
#Select the '''Asset''' to be calibrated.
 
+
#Go to: '''Group''' ICON
= Assign the Calibration Group to Assets =
+
#At the '''GROUP''' '''LIST''' tab, select '''ASSIGN GROUP'''.  
 
+
#Select'''Calibration Assignment '''from '''Category''' drop-down at the top bar to search the associated groups.
&nbsp;
+
#Select the '''Groups''' to which the Technician belongs.&nbsp;
 
+
#Select the Category'''Calibration Notification'''.  
#Go to: '''Shop Floor Control > Config > CMMS Asset '''and select the Asset to edit.  
+
#Select the Group to which the Approver belongs so the users receive email notification.
#Add Calibration Categories to this Asset's Group:
 
#Go to Group Tab.  
 
#Add Calibration Categories one at a time.  
 
 
 
&nbsp;
 
  
'''Figure 3: Set Calibration Category'''
+
'''Figure 1: Assign Group&nbsp;'''
  
[[File:Calibration category.png|RTENOTITLE]]
+
[[File:Group for asset.png|border|800px|1 Group.png]]
  
'''Figure 4: Set Group for Asset'''
+
'''Figure 2: Default&nbsp;&nbsp;Group'''
  
[[File:Assign group to asset.png|800px|Assign group to asset.png]]
+
[[File:Is Default group.png|border|800px|Add group user.png]]
  
 
&nbsp;
 
&nbsp;
  
= Assign the Calibration. =
+
= <span class="mw-headline" id="Configure_the_Calibration_Fields."><span class="mw-headline" id="Configure_the_Calibration_Fields."><span class="mw-headline" id="Configure_the_Calibration_Fields."><span class="mw-headline" id="Configure_the_Calibration_Fields."><span class="mw-headline" id="Assign_the_Calibration."><span class="mw-headline" id="Assign_the_Calibration."><span class="mw-headline" id="Assign_the_Calibration."><span class="mw-headline" id="Assign_the_Calibration."><span class="mw-headline" id="Assign_the_Calibration."><span class="mw-headline" id="Assign_the_Calibration.">Configure the Calibration Fields.</span></span></span></span></span></span></span></span></span></span> =
  
#At the Edit Asset Page, move to the Asset’s '''Calibration''' Tab.  
+
#Select the asset at the&nbsp;Asset Page, the Calibration icon show.
 +
#At the&nbsp;Asset’s '''Calibration'''&nbsp;pop-up window.  
 
#Complete the following mandatory fields:  
 
#Complete the following mandatory fields:  
 
<ul style="margin-left: 40px;">
 
<ul style="margin-left: 40px;">
Line 46: Line 41:
 
<li>'''Last Calibration Date'''</li>
 
<li>'''Last Calibration Date'''</li>
 
<li>'''Interval (mth)'''</li>
 
<li>'''Interval (mth)'''</li>
<li>The system will populate&nbsp;'''Next Calibration Date''' based on the Last Calibration Date and the number of months selected in the Interval section.</li>
+
<li>The system will populate the&nbsp;'''Next Calibration Date''' based on the Last Calibration Date and the number of months selected in the Interval section.</li>
 
<li>'''Grace Period(Days)'''.</li>
 
<li>'''Grace Period(Days)'''.</li>
 +
<li>'''Needs Approval'''</li>
 +
<li>'''Approval User'''</li>
 
</ul>
 
</ul>
 
<ol start="3">
 
<ol start="3">
Line 54: Line 51:
 
</ol>
 
</ol>
  
'''Figure 5: Edit Asset Calibration Tab'''
+
'''Figure 3: Edit Asset Calibration Fields'''
 
 
[[File:Calibration tab.png|800px|Calibration tab.png]]
 
<ol start="5">
 
<li>Email notification goes to the Assigned group members, including Requester and Approver.</li>
 
</ol>
 
 
 
&nbsp;
 
 
 
'''Figure 6: Assigned Alter Email'''
 
  
[[File:Assigned Alter Email.png|800px|Assigned Alter Email.png]]
+
[[File:Calibration for asset.png|border|800px|Calibration tab.png]]
  
 
&nbsp;
 
&nbsp;
  
= Complete the Calibration on the Asset =
+
= <span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset"><span class="mw-headline" id="Complete_the_Calibration_on_the_Asset">Complete the Calibration on the Asset</span></span></span></span></span></span></span></span></span></span> =
  
#Go to:'''Production > CMMS Calibration > My Assigned'''.  
+
#Go to:'''Production > CMMS > Calibration > My Assigned'''.  
 
#Double click on the '''Asset Name'''.  
 
#Double click on the '''Asset Name'''.  
 
#Fill out the following mandatory fields:  
 
#Fill out the following mandatory fields:  
Line 85: Line 73:
 
</ol>
 
</ol>
  
'''Figure 7: Calibration Assigned'''
+
'''Figure 4: Calibration Assigned'''
  
[[File:Calibartion Assigned.png|800px|Calibartion Assigned.png]]
+
[[File:Calibration my assigned.png|border|800px|Calibartion Assigned.png]]
 
<ol start="6">
 
<ol start="6">
 
<li>Email notification goes to the Approver and the assigned group members (this person was selected when the Calibration needs approver) (Step 2).</li>
 
<li>Email notification goes to the Approver and the assigned group members (this person was selected when the Calibration needs approver) (Step 2).</li>
Line 94: Line 82:
 
&nbsp;
 
&nbsp;
  
'''Figure 8: Status Change alter Email'''
+
= <span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration"><span class="mw-headline" id="Approve_.28or_Reject.29_the_Calibration">Approve (or Reject) the Calibration</span></span></span></span></span></span></span></span></span></span> =
 
 
[[File:Status Change Alter Email.png|800px|Status Change Alter Email.png]]
 
 
 
&nbsp;
 
 
 
= Approve (or Reject) the Calibration =
 
  
#Go to: '''Production > CMMS Calibration > My Approvals'''.  
+
#Go to: '''Production > CMMS > Calibration > My Approvals'''.  
 
#Double click on the Asset Name.  
 
#Double click on the Asset Name.  
 
#Complete the following mandatory fields:  
 
#Complete the following mandatory fields:  
 
<ul style="margin-left: 40px;">
 
<ul style="margin-left: 40px;">
 
<li>'''Input Status''': Select Approved or Rejected.</li>
 
<li>'''Input Status''': Select Approved or Rejected.</li>
<li>'''Actual Cal Date'''.</li>
+
<li>'''Actual Calibration Date'''.</li>
 
</ul>
 
</ul>
 
<ol start="4">
 
<ol start="4">
Line 113: Line 95:
 
</ol>
 
</ol>
  
'''Figure 9: Calibration Approval'''
+
'''Figure 5: Calibration Approval'''
  
[[File:Calibration approval.png|800px|Calibration approval.png]]
+
[[File:Calibration my approvals.png|border|800px|Calibration approval.png]]
  
 
Email notification goes to the approver, requester, and assigned group members.
 
Email notification goes to the approver, requester, and assigned group members.
 
&nbsp;
 
 
'''Figure 10: Approval Alter Email'''
 
 
[[File:Approval alter email.png|800px|Approval alter email.png]]
 
  
 
&nbsp;
 
&nbsp;
Line 129: Line 105:
 
&nbsp;
 
&nbsp;
  
= Reschedule the Calibration =
+
= <span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration"><span class="mw-headline" id="Reschedule_the_Calibration">Reschedule the Calibration</span></span></span></span></span></span></span></span></span></span> =
  
#Go to:'''Production > CMMS Calibration > My Rescheduling'''.  
+
#Go to:'''Production > CMMS > Calibration > My Rescheduling'''.  
 
#Double click on the Asset Name.  
 
#Double click on the Asset Name.  
 
#Complete the following mandatory fields:  
 
#Complete the following mandatory fields:  
Line 141: Line 117:
 
</ol>
 
</ol>
  
'''Figure 11: My Rescheduling'''
+
'''Figure 6: My Rescheduling'''
  
[[File:Calibration rescheduled.png|800px|Calibration rescheduled.png]]
+
[[File:Calibration rescheduling.png|border|800px|Calibration rescheduled.png]]
  
 
&nbsp;
 
&nbsp;
  
&nbsp;
+
----
  
 
&nbsp;
 
&nbsp;
  
 
&nbsp;
 
&nbsp;
 
= Revision Log =
 
 
{| border="1" class="wikitable"
 
|-
 
! style="text-align: center; background-color: rgb(0, 168, 168); width: 60px;" | Revision
 
! style="text-align: center; background-color: rgb(0, 168, 168); width: 86px;" | Revision Date
 
! style="text-align: center; background-color: rgb(0, 168, 168); width: 293px;" | Description
 
! style="text-align: center; background-color: rgb(0, 168, 168);" | Updated by
 
! style="text-align: center; background-color: rgb(0, 168, 168);" | Approved by
 
|-
 
| style="width: 60px;" | 1
 
| style="width: 86px;" | 12/19/18
 
| style="width: 293px;" | Initial Draft
 
| Martha Jordan
 
| &nbsp;
 
|-
 
| style="width: 60px;" | 1A
 
| style="width: 86px;" | 4/11/19
 
| style="width: 293px;" | Update screenshots. Correct some mandatory fields
 
Add Reschedule section </td>
 
 
| Helena Wang
 
| &nbsp;
 
|-
 
| style="width: 60px;" | 2
 
| style="width: 86px;" | 8/12/2020
 
| style="width: 293px;" | Title Update and link update
 
| Elaine Fonaro
 
| &nbsp;
 
|-
 
| style="width: 60px;" | 2A
 
| style="width: 86px;" | 8/12/2020
 
| style="width: 293px;" | Revision Log Update, Renamed screenshots to Figures.
 
| Marisol Vargas
 
| &nbsp;
 
|}
 

Latest revision as of 05:41, 11 September 2024


Summary

This doc will tell the users how to manage calibration in CMMS.

Prerequisites

  • Groups are defined (Shop Floor Control > Configuration > CMMS Admin > Group)
  • Calibration Assignment/Calibration Notification Categories are selected for the Group (Shop Floor Control > Configuration > CMMS Asset > Group > Assign Group > Category. Can also be accomplished when Group is defined).
  • Asset is created (Shop Floor Control > Configuration > CMMS Asset > Asset)
 

Configure the Calibration Groups

  1. Select the Asset to be calibrated.
  2. Go to: Group ICON
  3. At the GROUP LIST tab, select ASSIGN GROUP.
  4. SelectCalibration Assignment from Category drop-down at the top bar to search the associated groups.
  5. Select the Groups to which the Technician belongs. 
  6. Select the CategoryCalibration Notification.
  7. Select the Group to which the Approver belongs so the users receive email notification.

Figure 1: Assign Group 

1 Group.png

Figure 2: Default  Group

Add group user.png

 

Configure the Calibration Fields.

  1. Select the asset at the Asset Page, the Calibration icon show.
  2. At the Asset’s Calibration pop-up window.
  3. Complete the following mandatory fields:
  • Calibration Needed checkbox.
  • Last Calibration Date
  • Interval (mth)
  • The system will populate the Next Calibration Date based on the Last Calibration Date and the number of months selected in the Interval section.
  • Grace Period(Days).
  • Needs Approval
  • Approval User
  1. Complete the other optional fields if needed.
  2. Save.

Figure 3: Edit Asset Calibration Fields

Calibration tab.png

 

Complete the Calibration on the Asset

  1. Go to:Production > CMMS > Calibration > My Assigned.
  2. Double click on the Asset Name.
  3. Fill out the following mandatory fields:
  • Input Status
  • Actual Calibrated Date

Note: Only the Input Statu be set to Complete - Approval, this calibration Asset’s go to the approval process.

  1. Fill out other optional fields if needed.
  2. Save.

Figure 4: Calibration Assigned

Calibartion Assigned.png

  1. Email notification goes to the Approver and the assigned group members (this person was selected when the Calibration needs approver) (Step 2).

 

Approve (or Reject) the Calibration

  1. Go to: Production > CMMS > Calibration > My Approvals.
  2. Double click on the Asset Name.
  3. Complete the following mandatory fields:
  • Input Status: Select Approved or Rejected.
  • Actual Calibration Date.
  1. Save.

Figure 5: Calibration Approval

Calibration approval.png

Email notification goes to the approver, requester, and assigned group members.

 

 

Reschedule the Calibration

  1. Go to:Production > CMMS > Calibration > My Rescheduling.
  2. Double click on the Asset Name.
  3. Complete the following mandatory fields:
  • Rescheduled Date.
  1. Save.

Figure 6: My Rescheduling

Calibration rescheduled.png