Difference between revisions of "42Q-MES0085-C Conduit Command Appendix"

From 42Q
Jump to navigation Jump to search
Line 29: Line 29:
 
Add Attribute does not have an equivalent in SFDC. It is effectively the equivalent of ADCMP2 but for an attribute. It allows adding an attribute for which a definition did not already exist.  
 
Add Attribute does not have an equivalent in SFDC. It is effectively the equivalent of ADCMP2 but for an attribute. It allows adding an attribute for which a definition did not already exist.  
  
=== AddAttributeTo ===
+
=== AddAttributeTo ===
  
Adds an attribute to the specified unit serial number. This command will produce an error if the attribute already exists, no replacement will occur. Similar to ADCMP2 for non-tracked components in SFDC this command does not require an existing attribute definition
+
Adds an attribute to the specified unit serial number. This command will produce an error if the attribute already exists, no replacement will occur. Similar to ADCMP2 for non-tracked components in SFDC this command does not require an existing attribute definition  
  
 
=== AddComment  ===
 
=== AddComment  ===
Line 37: Line 37:
 
Adds a comment checked against an optional mask to the scanned unit.  Add Comment is equivalent to ADCOMMENT in SFDC.  
 
Adds a comment checked against an optional mask to the scanned unit.  Add Comment is equivalent to ADCOMMENT in SFDC.  
  
=== AddCommentTo ===
+
=== AddCommentTo ===
  
Adds a comment checked against an optional mask to the specified unit. Equivalent to ADCOMMENT in SFDC.
+
Adds a comment checked against an optional mask to the specified unit. Equivalent to ADCOMMENT in SFDC.  
  
 
=== AddDefinedAttribute  ===
 
=== AddDefinedAttribute  ===
Line 45: Line 45:
 
Add Defined Attribute is equivalent to ATTADD in SFDC. Unlike SFDC it is designed to be used with the Conduit “Scanning Template” construct for units that have active / unreconciled Assembly / Attr_Def entries. AddMeasurementKey Add Measurement Key is equivalent to MEASKEY in SFDC.  
 
Add Defined Attribute is equivalent to ATTADD in SFDC. Unlike SFDC it is designed to be used with the Conduit “Scanning Template” construct for units that have active / unreconciled Assembly / Attr_Def entries. AddMeasurementKey Add Measurement Key is equivalent to MEASKEY in SFDC.  
  
=== AddMeasurementKey ===
+
=== AddMeasurementKey ===
  
Adds a measurement key to the scanned unit. Equivalent to MEASKEY in SFDC.
+
Adds a measurement key to the scanned unit. Equivalent to MEASKEY in SFDC.  
  
=== AddMeasurementKeyTo ===
+
=== AddMeasurementKeyTo ===
  
Adds a measurement key to the specified unit. Equivalent to MEASKEY in SFDC.
+
Adds a measurement key to the specified unit. Equivalent to MEASKEY in SFDC.  
  
 
=== AddNontrackedAssemblyComponent  ===
 
=== AddNontrackedAssemblyComponent  ===
Line 61: Line 61:
 
Add Nontracked Component is effectively identical to ADCMP2 AddTrackedAssemblyComponent Add Tracked Assembly Component is the tracked version of the Scanning Template enabled ADCMP command in SFDC.  
 
Add Nontracked Component is effectively identical to ADCMP2 AddTrackedAssemblyComponent Add Tracked Assembly Component is the tracked version of the Scanning Template enabled ADCMP command in SFDC.  
  
=== AddNontrackedComponentTo ===
+
=== AddNontrackedComponentTo ===
  
Adds a non-tracked component to the specified unit. Unlike Add Non-Tracked Component this does not require a scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.
+
Adds a non-tracked component to the specified unit. Unlike Add Non-Tracked Component this does not require a scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.  
  
 
=== AddTrackedComponent  ===
 
=== AddTrackedComponent  ===
Line 69: Line 69:
 
Add Tracked Component is equivalent to ADCMP3 in SFDC.  
 
Add Tracked Component is equivalent to ADCMP3 in SFDC.  
  
=== AddUniqueComponent ===
+
=== AddUniqueComponent ===
  
Adds a non-tracked component to the specified unit. Unlike Add Non-Tracked Component this does not require a scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.
+
Adds a non-tracked component to the specified unit. Unlike Add Non-Tracked Component this does not require a scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.  
  
 
=== AddUniqueAssemblyComponent  ===
 
=== AddUniqueAssemblyComponent  ===
Line 77: Line 77:
 
Add Unique Assembly Component is the unique component version of the Scanning Template enabled ADCMP command in SFDC. AddUniqueComponent Add Unique Component has no corollary in SFDC today. It is designed to add a unique component without a predefined assembly record just like ADCMP2 (non-tracked) or ADCMP3 (tracked). AddUnitToContainer Add Unit To Container has no equivalent command in SFDC. SFDC Containerization essentially does the same thing via complicated mini-sessions executed after NEWCNTNR / OPENCNTNR.  
 
Add Unique Assembly Component is the unique component version of the Scanning Template enabled ADCMP command in SFDC. AddUniqueComponent Add Unique Component has no corollary in SFDC today. It is designed to add a unique component without a predefined assembly record just like ADCMP2 (non-tracked) or ADCMP3 (tracked). AddUnitToContainer Add Unit To Container has no equivalent command in SFDC. SFDC Containerization essentially does the same thing via complicated mini-sessions executed after NEWCNTNR / OPENCNTNR.  
  
=== AddUnitToContainer ===
+
=== AddUnitToContainer ===
  
Adds provided unit serial number to the scanned container serial.
+
Adds provided unit serial number to the scanned container serial.  
  
 
=== AddUnitToLot  ===
 
=== AddUnitToLot  ===
Line 85: Line 85:
 
Add Unit To Lot has no equivalent command in SFDC. SFDC “Lotization” is handled via cumbersome sessions within NEWLOT / OPENLOT.  
 
Add Unit To Lot has no equivalent command in SFDC. SFDC “Lotization” is handled via cumbersome sessions within NEWLOT / OPENLOT.  
  
=== AdvancedShopOrderUnits ===
+
=== AdvancedShopOrderUnits ===
  
Ends up to <unit limit> units for the supplied shop order number at the provided workstation. Units are chosen in FIFO order for the specified workstation. This command can be executed without a transaction unit.
+
Ends up to <unit limit> units for the supplied shop order number at the provided workstation. Units are chosen in FIFO order for the specified workstation. This command can be executed without a transaction unit.  
  
 
=== ApplyMeo  ===
 
=== ApplyMeo  ===
Line 119: Line 119:
 
=== CloseContainer  ===
 
=== CloseContainer  ===
  
Close Container is equivalent to CLOSECNTNR. CloseLot Close Lot is equivalent to CLOSELOT.  
+
Close Container is equivalent to CLOSECNTNR.  
 +
 
 +
=== CloseLot ===
 +
 
 +
Close Lot is equivalent to CLOSELOT.
 +
 
 +
=== ConsumeNonSerialized Batch ===
 +
 
 +
Consume non serialized batch consumes non serialized batches.
 +
 
 +
=== ConsumeSitBatch ===
 +
 
 +
Consume the specified quantity from the provided Sit Batch serial and add a non-tracked component matching the sit batch serial number to the scanned unit at the specified reference designator.
 +
 
 +
=== CreateBatchSerial ===
 +
 
 +
Creates a Batch Serial number with the provided serial number, batch quantity and shop order number. Can be executed in place of a transaction unit. Roughly equivalent to CRE8BSN in SFDC.
  
 
=== CreateContainer  ===
 
=== CreateContainer  ===
  
 
Create Container creates a container serial number. Unlike NEWCNTNR it does not immediately initiate prompting for container units. It only creates a container.  
 
Create Container creates a container serial number. Unlike NEWCNTNR it does not immediately initiate prompting for container units. It only creates a container.  
 +
 +
=== CreateGeneratedBatchSerial ===
 +
 +
Creates a batch serial using the supplied quantity and shop order number. The actual batch serial number will be generated using provided algorithm. Can be executed in place of a transaction unit.
  
 
=== CreateLot  ===
 
=== CreateLot  ===
Line 142: Line 162:
  
 
== F  ==
 
== F  ==
 +
 +
=== FindClientStations ===
 +
 +
Finds client stations.
 +
 +
=== FindUnitActivity ===
 +
 +
Attempts to find the unit activity for the provided serial number and optional part number.
  
 
== G  ==
 
== G  ==
Line 160: Line 188:
  
 
== M  ==
 
== M  ==
 +
 +
=== MergeBatchSerial ===
 +
 +
Merge the provided batch serial number into the scanned batch unit.
  
 
=== MOVE  ===
 
=== MOVE  ===
Line 178: Line 210:
  
 
== P  ==
 
== P  ==
 +
 +
=== PrintDemoLabel ===
 +
 +
Print a demo label name for the currently scanned unit serial number to the specified print queue.
  
 
=== Print Label  ===
 
=== Print Label  ===
Line 194: Line 230:
  
 
Traverses the entire component tree and checks to see if a component serial is on hold. RecordDefect Records a defect against a unit. Equivalent to RCDFC in SFDC.  
 
Traverses the entire component tree and checks to see if a component serial is on hold. RecordDefect Records a defect against a unit. Equivalent to RCDFC in SFDC.  
 +
 +
=== RecordDefect ===
 +
 +
Records a defect against the scanned unit. Equivalent to RCDFC in SFDC.
  
 
=== RejectIfMissingAttribute  ===
 
=== RejectIfMissingAttribute  ===
Line 202: Line 242:
  
 
Fails a unit that is missing any configured attributes. Equivalent to VERATT.ALL.  
 
Fails a unit that is missing any configured attributes. Equivalent to VERATT.ALL.  
 +
 +
=== RejectIfMissingComponents ===
 +
 +
Fails a unit that is missing any assembly components. Unlike VERCMP this command has to be provided with a failure location just like Reject if Missing Attribute[s] (VERATT).
  
 
=== RejectIfMissingProcessAttributes  ===
 
=== RejectIfMissingProcessAttributes  ===
  
 
Fails a unit that is missing any attributes matching the current scanning location’s process. Effectively equivalent to VERATT.PROC.  
 
Fails a unit that is missing any attributes matching the current scanning location’s process. Effectively equivalent to VERATT.PROC.  
 
=== RejectIfMissingComponents  ===
 
 
Fails a unit that is missing any assembly components. Unlike VERCMP this command has to be provided with a failure location just like Reject if Missing Attribute[s] (VERATT).
 
  
 
=== RemoveAllComponents  ===
 
=== RemoveAllComponents  ===
Line 222: Line 262:
  
 
Removes a component. Similar to RMCMP2.  
 
Removes a component. Similar to RMCMP2.  
 +
 +
=== RemoveComponentFrom ===
 +
 +
Removes a component of any type matching the provided <component id> from the specified unit.
 +
 +
=== RemoveProcesAttributes ===
 +
 +
Removes any attributes defined for addition at the provided process from the scanned unit.
 +
 +
=== RemoveProcessComponents ===
 +
 +
Removes any components defined for addition at the provided process from the scanned unit.
  
 
=== RemoveUnitFromContainer  ===
 
=== RemoveUnitFromContainer  ===
Line 238: Line 290:
  
 
Replace an existing attribute with a new attribute.  
 
Replace an existing attribute with a new attribute.  
 +
 +
=== ReplaceAttributeOn ===
 +
 +
Replaces an attribute (if one exists) and adds one to the specified unit serial number. Similar to ADCMP2 for non-tracked components in SFDC this command does not require an existing attribute definition.
 +
 +
=== ReplaceComponent ===
 +
 +
Replaces a component at the provided <component id> on the scanned unit with a new component. Equivalent to RPCMP2 in SFDC.
  
 
=== ReplaceNontrackedAssemblyComponent  ===
 
=== ReplaceNontrackedAssemblyComponent  ===

Revision as of 14:11, 21 April 2017

42Q Home > Conduit > Conduit Command Appendix
Sanmina logo.png


Conduit
Conduit Command Appendix
Version MES15 Portal 1.10
Work Instruction


This Work Instruction is 42Q's corporate standard.
This document is under revision control. The latest revision is located on Intranet.
Once printed it is an uncontrolled copy. All alterations to this work instruction require approval.
Contact the IT Global Education and Training Department to submit suggested alterations and or updates.


This edition applies to MES15 Portal 1.0 and all subsequent releases and modifications until otherwise indicated in new revisions.

Contents


Command Appendix Registry

The commands defined within the Conduit Command Registry represent the core functionality of the Conduit system. Unlike with legacy systems, Conduit commands are full words, generally Pascal case (though technically command names are case insensitive.)

In addition to the more extensive names, Conduit Commands tend to be more focused toward a single concept. Most Conduit commands expect all of their data to be provided up front, leaving the work of gathering that data to the various client implementations in conjunction with the CCRS.

The commands referencing Assembly or Defined components and attribute respectively are designed for use with the Scanning Template mechanism in Conduit. The basic concept is that the actual command to use (tracked, unique, nontracked, etc.) will be provided by Conduit. Individual clients only need to prompt for the appropriate piece of data to satisfy the scan template then construct a Client Command from the Scan Template + user input.

The full list of commands and a short explanation of each are given below:


A

AddAttribute

Add Attribute does not have an equivalent in SFDC. It is effectively the equivalent of ADCMP2 but for an attribute. It allows adding an attribute for which a definition did not already exist.

AddAttributeTo

Adds an attribute to the specified unit serial number. This command will produce an error if the attribute already exists, no replacement will occur. Similar to ADCMP2 for non-tracked components in SFDC this command does not require an existing attribute definition

AddComment

Adds a comment checked against an optional mask to the scanned unit.  Add Comment is equivalent to ADCOMMENT in SFDC.

AddCommentTo

Adds a comment checked against an optional mask to the specified unit. Equivalent to ADCOMMENT in SFDC.

AddDefinedAttribute

Add Defined Attribute is equivalent to ATTADD in SFDC. Unlike SFDC it is designed to be used with the Conduit “Scanning Template” construct for units that have active / unreconciled Assembly / Attr_Def entries. AddMeasurementKey Add Measurement Key is equivalent to MEASKEY in SFDC.

AddMeasurementKey

Adds a measurement key to the scanned unit. Equivalent to MEASKEY in SFDC.

AddMeasurementKeyTo

Adds a measurement key to the specified unit. Equivalent to MEASKEY in SFDC.

AddNontrackedAssemblyComponent

Add Nontracked Assembly Component is a “Scanning Template” specific command for adding a non-tracked component based on an unreconciled assembly record for a unit. It is equivalent to ADCMP

AddNontrackedComponent

Add Nontracked Component is effectively identical to ADCMP2 AddTrackedAssemblyComponent Add Tracked Assembly Component is the tracked version of the Scanning Template enabled ADCMP command in SFDC.

AddNontrackedComponentTo

Adds a non-tracked component to the specified unit. Unlike Add Non-Tracked Component this does not require a scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.

AddTrackedComponent

Add Tracked Component is equivalent to ADCMP3 in SFDC.

AddUniqueComponent

Adds a non-tracked component to the specified unit. Unlike Add Non-Tracked Component this does not require a scanned unit. This command will not replace an existing unremoved component with that component id but it will mark a previously removed component as replaced.

AddUniqueAssemblyComponent

Add Unique Assembly Component is the unique component version of the Scanning Template enabled ADCMP command in SFDC. AddUniqueComponent Add Unique Component has no corollary in SFDC today. It is designed to add a unique component without a predefined assembly record just like ADCMP2 (non-tracked) or ADCMP3 (tracked). AddUnitToContainer Add Unit To Container has no equivalent command in SFDC. SFDC Containerization essentially does the same thing via complicated mini-sessions executed after NEWCNTNR / OPENCNTNR.

AddUnitToContainer

Adds provided unit serial number to the scanned container serial.

AddUnitToLot

Add Unit To Lot has no equivalent command in SFDC. SFDC “Lotization” is handled via cumbersome sessions within NEWLOT / OPENLOT.

AdvancedShopOrderUnits

Ends up to <unit limit> units for the supplied shop order number at the provided workstation. Units are chosen in FIFO order for the specified workstation. This command can be executed without a transaction unit.

ApplyMeo

Apply Meo is equivalent to ADMEO.

B

C

ChangePartNumber

Change Part Number is equivalent to CHGPN.

ChangeRevision

Change Revision is equivalent to CHGREV.

ChangeSerialNumber

Change Serial Number is equivalent to CHGID.

ClearMatchingAttributes

Clear Matching Attributes is designed to remove attributes that match a particular input. It is equivalent to CLRATT.L.

ClearNonmatchingAttributes

Clear Non-Matching Attributes is designed to remove attributes that do NOT match a particular input. It is equivalent to CLARATT.R.

CloseContainer

Close Container is equivalent to CLOSECNTNR.

CloseLot

Close Lot is equivalent to CLOSELOT.

ConsumeNonSerialized Batch

Consume non serialized batch consumes non serialized batches.

ConsumeSitBatch

Consume the specified quantity from the provided Sit Batch serial and add a non-tracked component matching the sit batch serial number to the scanned unit at the specified reference designator.

CreateBatchSerial

Creates a Batch Serial number with the provided serial number, batch quantity and shop order number. Can be executed in place of a transaction unit. Roughly equivalent to CRE8BSN in SFDC.

CreateContainer

Create Container creates a container serial number. Unlike NEWCNTNR it does not immediately initiate prompting for container units. It only creates a container.

CreateGeneratedBatchSerial

Creates a batch serial using the supplied quantity and shop order number. The actual batch serial number will be generated using provided algorithm. Can be executed in place of a transaction unit.

CreateLot

Create Lot creates a lot serial number. Unlike NEWLOT it does not initiate prompting for lot units. It only creates a lot.

CreateUnit

Create Unit is a command used to create a new unit.

D

E

END

End is effectively identical to END in SFDC.

F

FindClientStations

Finds client stations.

FindUnitActivity

Attempts to find the unit activity for the provided serial number and optional part number.

G

I

J

K

L

LegacyCustomCommand

Should never be executed directly, Conduit understands !!1 and !!2 commands natively and uses this command to structure the executable call.

M

MergeBatchSerial

Merge the provided batch serial number into the scanned batch unit.

MOVE

Effectively identical to MOVE in SFDC.

N

O

OpenContainer

Changes the status of a container to Open. Does not initiate container serial scanning like OPENCNTR.

OpenLot

Changes the status of a lot to Open. Does not initiate lot serial scanning like OPENLOT.

P

PrintDemoLabel

Print a demo label name for the currently scanned unit serial number to the specified print queue.

Print Label

Prints labels.  Tied to the label set up in Production --> Label Engine Labels.  

Print Legacy Label

Prints MES labels.

Q

R

ReconcileComponentMFGHolds

Traverses the entire component tree and checks to see if a component serial is on hold. RecordDefect Records a defect against a unit. Equivalent to RCDFC in SFDC.

RecordDefect

Records a defect against the scanned unit. Equivalent to RCDFC in SFDC.

RejectIfMissingAttribute

Fails a unit that is missing the provided attribute. Equivalent to VERATT.LIST.

RejectIfMissingAttributes

Fails a unit that is missing any configured attributes. Equivalent to VERATT.ALL.

RejectIfMissingComponents

Fails a unit that is missing any assembly components. Unlike VERCMP this command has to be provided with a failure location just like Reject if Missing Attribute[s] (VERATT).

RejectIfMissingProcessAttributes

Fails a unit that is missing any attributes matching the current scanning location’s process. Effectively equivalent to VERATT.PROC.

RemoveAllComponents

Removes all components from a unit. Equivalent to RMCMPALL.

RemoveAttribute

Removes an attribute. Similar to ATTREMOVE but the specific attribute must be provided.

RemoveComponent

Removes a component. Similar to RMCMP2.

RemoveComponentFrom

Removes a component of any type matching the provided <component id> from the specified unit.

RemoveProcesAttributes

Removes any attributes defined for addition at the provided process from the scanned unit.

RemoveProcessComponents

Removes any components defined for addition at the provided process from the scanned unit.

RemoveUnitFromContainer

Removes a unit from a container. Equivalent to RMVFRMCNTNR.

RemoveUnitFromLot

Removes a unit from a lot. Equivalent to RMVFRMLOT.

RepairDefect

Repair a defect on a unit. Similar to RCRPR but the defect sequence to be repaired must be provided.

ReplaceAttribute

Replace an existing attribute with a new attribute.

ReplaceAttributeOn

Replaces an attribute (if one exists) and adds one to the specified unit serial number. Similar to ADCMP2 for non-tracked components in SFDC this command does not require an existing attribute definition.

ReplaceComponent

Replaces a component at the provided <component id> on the scanned unit with a new component. Equivalent to RPCMP2 in SFDC.

ReplaceNontrackedAssemblyComponent

Replace a previously existing “Scanning Template” non-tracked component with a new one.

ReplaceNontrackedComponent

Replace a previously existing non-tracked component; equivalent to RPCMP2.

ReplaceTrackedAssemblyComponent

Replace a preexisting “Scanning Template” tracked component with a new one.

ReplaceTrackedComponent

Replace a previously existing tracked component, effectively equivalent to RPCMP2.

ReplaceUniqueComponent

Replace a preexisting unique component. SplitPanel Effectively equivalent to SPLTP. ViewComponents Equivalent to VWCMP. ViewDefects Effectively equivalent to VWDFC. ViewHistory Effectively equivalent to VWHST.

S

U

V

W

X

Y

Z

Conduit Command Listing

Every command currently available can be found at the following URL:

http://p88conduit1:18005/ccr


Definitions for specific commands can be found at the following URL:

http://p88conduit1:18005/ccr/AddComment


Document Revision History

Date Author Title Version Change Reference
01/26/17 Benjamin Cavanaugh Technical Writer v 1.10 This is the first version of the Conduit Command Appendix.